HomeMy WebLinkAboutMiscellaneous
November 12, 1997
Mrs. Shirley Volk
Development Coordinator
CITY 4F COLLEGE STATION
P.O. Box 99b0
College Station, Texas 77842
RE: Final Plat Submittal
College Station Utility Customer Service Center
Dear Shirley:
Attached please find the following items for the above referenced final plat submittal:
1. .Ten (10) folded blueline prints of final plat
2. Completed Application
Please notify me of the date and time. of PRC. I will submit a mylar reproducible after any
staff required- revisions have been completed.
Should you have any questions or need additional information, please advise.
Very truly yours,
~~~
Mi hael R. cClu e, P.E;, R.P.L. S.
MRM/rnlm
attachments
1722 Broadmoor, Suite 210 Bryan, Texas 77802 (409) 776-6700 FAX (409) 776-6699
ent _ofprescrptive: easement~~-- ~ ~ -- ~---__ ~ ~ __
---- ---- ----- - o~..e 1
From: Cameron Reynolds
To: PKaspar
Date: 11/18/97 3:05PM
Subject: abandonment of prescriptive easement
There really are two ways to abandon a prescriptive easement:
1) File an abandoment of easement at the courthouse relinquishing the rights to the easement
2) Conduct which indicates the relinquishment ofithe rights in the easement such as nonuse for an
extensive period of time (ovbiously, this is much harder to prove either way)
Advice: Abandon the easement via instrument and file at the courthouse. Prescriptive easements, while
not recorded, are indeed property rights which do exist and should be abandoned.. Hope this helps!
:::..::.::::_::.:.:::.k :.::.,::::::::.:::.:,:::....::::.::..:.:.:::.:::.:::.:::.:::....._.:.,.:::::
Paul Kaspar PRC
From: Lawrence Carter
To: Natalie Ruiz
Date: 11/14/97 4;OOPM
Subject: PRC
Avenue A
I think that the sewer for Avenue A should be rurr along the west side of the street and then the water
t
' e of the street rather than in the rearas shown on the plat. The pla
line could be run on the east sid
~ does not show the 12 inch water line on the southside of Lincoln which could supply a 6 inch line on
Avenue A. This would allow us time to extend the line on Nimitz at our convenience and then kill the 1"
line in the rear of the-lots on AvenueA.
i
I
I
j
i
i
From: Natalie. Ruiz
To: prcagenda
Date: 11 /13197 8:48AM
Subject: 11/19 PRC Meeting
We are in the process of scheduling an NRB subcommittee meeting to discuss the following case:
SIGN - 105 College Main in the Northgate zoning district, Leyenda's Fruit Juice Bar.
It looks like this. meeting will be at 1.0:00 on Wednedsay, 11/19 in the City Hall Training Room. If this
changes, I:will let you know..
The following are two final plats that were also submitted for review. They may not require a formal
PRC meeting. Please return comments to Shirley Volk by Monday, 11/17 so that we may forward them
to the applicant.
FINAL. PLAT -Proposed resubdivision of a portion of lot 6 of the D.A. Smith Subdivision located at 309
Lincoln Avenue. The applicant is proposing to subdivide one..296 acre lot into 3 single family lots.
FINAL PLAT -College Station lJtility Customer Service Center - An 11.563 acre subdivision consisting of
1 lot on the corner of Krenek Tap Road and King Cole Drive.
If you have .any questions, please, let me know. Thanks.
\ \
zc N E x-
,; \\~,\~
,. ~~ ,~
>,
i,
~ ~ ~.
~~~ ~
ZOPdE ,4E ~~','
,~~ /
~/
~ ~ ~r'
~~/
~~
~c
~~'2
9
n ~
%~i~
~ ~ ~ f
~~
`,;,
/ ~~ ~~.--- Zo N E x
~ ~ j
i /~ ~ / ~-
.~/
~'j ~;~f/, ~/
ZONE X
MINIMUM RE UIREMENTS FOR FINAL PLATS
ALL CITY~RDINANCES MUST BE MET))
INCLUDING BUT NOT LIMITED TO THE FOLL(~WINGo
(Requirements based on field survey and marked by monuments and markers)
~~
' ^ 1. Drawn on 24" x 36" sheet to scale of 100' per inch.
~
i
^
a. vicinity map which includes enough of surrounding area to show general location of
i
~" subject property in relationship to College .Station and its City Limits. No scale requred
.~ but include north arrow.
~~~: ^ 2. Name & address of subdivider, recorded owner, planner, engineer and surveyor.
^ 3. Name & address of all lenders on the property.
^ 4. Name & address of all easement holders.
^ 5. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision
''il
in Brazos County, Texas).
!,' ^ 6. Date of preparation,. scale in feet and north arrow.
~' ^ 7. Application fee.
^ 8. Construction documents on 24" x 36" sheets.
^ 9. Paid tax certificates from City of College Station, Brazos County and the C.S.LS.D.
^ 10. Total area intended to be developed.
^ 11. Subdivision boundary lines indicated by heavy lines.
^ 12. Certificate of Ownership & Dedication;
Certificate of Surveyorship and/or Engineer;
Certificate of City Engineer;
Approval of Commission;..
Approval of City Council;
', Certificate of the County Clerk.
(Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration).
'' ~ ^ 13. Number of lots.
^ a. number of lots by Zoning District.
^ b. average acreage of each residential lot by Zoning District.
^ 14. Approximate area of street right-of--way.
^ 15. Proposed parkland dedication information.
^ 16. Requested oversize participation items, if any.
^ 17. Location of the One Hundred Yr. Floodplain according to the most recent available date.
^ 18. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch.
;~ .. ,
^ 19. Exact location, dimensions, name and legal description of all existing or recorded streets,
alleys, reservations, easements or other R.O.W. within the subdivision, intersecting or
contiguous with boundary or forming boundary with accurate dimensions, bearings or
deflection angles and radii, area, center angle, degree of curvature, tangent distance and.
length of all curves.
^ 20. Same information for proposed streets, alleys, etc. as preliminary plats.
^ 21. Lot corner markers and survey monuments (by symbol) and tied to basic survey data.
^ 22. Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost
estimates.
^ 23. Sanitary sewer plat .with 2 foot contours, plan and profile lines, showing depth and grades,
with cost estimates.
^ 24. Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost
estimate.
^ 25. Storm drainage system plat with 2 foot contours, .street lines, inlets, storm sewer and
drainage channels, with profiles and sections, and showing drainage and runoff areas, and
runoff based on 5, 10, and 25 year rain intensity. Detail drainage structure design and
channel lining design if used, with specification and detail cost estimate.
^ 26. Street- lighting plan showing 1location of lights, design, and with specifications and detail cost
estimate.
^ 27. Submit a statement addressing any differences between the final plat and approved Master
Preliminary Plat & Plan.
^ 28. Indicate any variances requested and reasons for same.
^ 30. Are there impact fees associated with this development?
^ 31. Add a general note that no private sewage facility may be installed on any lot in this
subdivision without the. issuance of a license by the Brazos County Health Unit under the
provisions of the private facility regulations adopted by the Commissioners Court of Brazos
County, pursuant to the provisions of Section 21.004 of the Texas Water Code.
fonne~planViJplet.~8.95