HomeMy WebLinkAboutMiscellaneous~ ~ 1~ ` STAFF. REVIEW NOTES Richards. Addition, Lot 10, Block 2 Case #97-245 '' ~(l Ordinance Re ~uirements: _ Are there any existing structures on the subject property? If so, submit a site plan showing the location of the structures to verify that no encroachments will be created with this lat. _ i n fee of $225.. ~ ~Q Subr~ut the parkland dedicat o (k-t.~ The final plat is a minor plat and can be approved at staff level. Remove he "Approval of 1R~I ~ Planning and Zoning..Commission" and "Approval of City Council" signature blocks. Revise the Cit En nneer si nature block as follows: Y g $ APPROVAL OF THE'CITY ENGINEER AND CITY PLANNER °~~a~" ~~~~ay~ - We, the undersigned, City Engineer and City Planner. of the City of College Station, hereby certify that this subdivision plat is in compliance with the appropriate codes and ordinances of the City of College Station. City Engineer, College Station, Texas Remove the setback fines. Revise the title block to refer to a "Final Plat" and not a "Replat". The subject property has never been formally platted. What does the "*" represent that is shown in the: call along the westernmost property line? (Explain the discrepancy between the two calls. What: happened to the 4.52'?) City Planner, College Station, Texas SUBMIT. THE REVISED MYLAR ORIGINAL AND 2 COPIES TO BE FILED AT THE BRAZOS COUNTY CLERK'S OFFICE. Natali uz November 5, 1997 Po -It~M br d fax transmittal memo 767 # of pages - To r Co /~C. (,.,~../ Dept. Pho Fax #: Fax ~~' / GTE COMMENTS NOVEMBER. 5, 1997 FINAL PLAT - RICHARDS ADDITION; PROPOSED RESUBDIVISION OF LOT 10, BLOCK 2 OF THE RICHARDS ADDITION LOCATED AT 201 STERLING STREET TOTALING .24 ACRES INTO TWO SINGLE FAMILY LOTS. GTE COMMENTS: NO PROBLEM WITH THE FINAL PLAT IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT LAVERNE AHIN WITH G'TE AT 409/821-4723. .10/23/97, 12:14 $409 764 3496 DEVELOPMENT SVCS ~~~ GARRETT 07]004/005 *.~ MINIMUM RE UIREMENTS FOR FINAL ~,rATS ((ALL CITY ~}RDYNANCES MUST BEM ll INCLITI~ING BUT NOT LIMITED TU THE FOLLOWING: (Requ' ementsbased an field survey and marked by monuments and markers} ~1. Drawn on 24" x 36"' sheet to scale of 100' per inch. C~" a. vicinity map which includes enough of surrounding area to show general.. location of subject property in relationship to College Station and its City Limits. Na scale requred 1 ~ but include north arrow. C~]' 2. Name & address of subdivider, recorded owner, planner,. engineer and surveyor. Ca'~ 3. Name & address of all lenders an the property.. C~f 4. Name & address of all easement holders. p~ S. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). CzY~ 6. Date of preparation, scale in feet and north arrow. ~7. Application fee. 8. Construction documents on 24" x 36" sheets. p~ g. Faid tax certificates. from City of College Station, Brazos County and the GS.T.S.D. 1.9~ 10. .Total area intended to be developed. 11. Subdivision boundary lines indicated by heavy lines. l~ 12. Certificate of Ownership & Dedication; Certificate of Surveyorship and/or Engineer; Certificate of City Engineer; Approval of Commission; Approval of City Council; Certificate of the County Clerk. / (Owner(s)' signatures} must be in place before taking plat to P&L for consideration}, C~ 13. Number of lots. C~ a, number of lots by Zoning District. CN' b. average acreage of each residential lot by Zoning District. I~ 14. Approximate area of street right-of--way. l~ 1.5. Proposed parkland dedication information. ~ 16. Requested oversize participation items, if any. ^ ~A 17. Location of the One Hundred Yr. Fioodplain according to the most recent available date. p~~ 18. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch. 10/23/97 12:15 V°i~.. ...,~A r $409 764 3496 DEVELOPMENT SVCS ~-~~ GARRETT ~ 0.05/005 Ii~ 19. Exact location, dimensions, name and legal description of all existing or recorded streets, alleys, reservations, easements or other R.O.W. within the subdivision, intersecting or contiguous with boundary or forming boundary with accurate dimensions, bearings or deflection angles Nand radii, area, center angle,. degree of curvature, tangent distance and length of ail curves. 20. Same information for proposed streets, alleys, etc. as preliminary plats. td' 21. Lot corner markers and survey monuments (by symbol} and tied to basic survey data. O 1'~ 22. Street, alley, and sidewalk plans, profiles and sections, with specifications and detail. cost estimates. O ft~ 23. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth ar~d grades, with cost estimates. ^ ~~ 24. Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost estimate. ^ ~!~ 25. Storm drainage system: plat with 2 foot contours, street Gnes, inlets, storm sewer and drainage channels, with profiles and sections, and showing drainage and runoff areas, and runoffbased an 5, 10, and 25 year rain intensity: Detail drainage structure design and' channel lining. design. if used, with specification and detail cost estimate. O-~~" 26. Street lighting .plan showing location. of lights, design, and with specifications and detail cost estimate. ^ ~& 27. Submit a statement addressing any differences between the final plat and approved Master Preliminary Plat & Pian. Q 28. Indicate any variances requested and reasons for same. ^-~+~ 30. .Are there impact fees associated with this development? ~k 31. Add a general note that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private. facility regulations adapted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. F,,,n,bi.,~fiJpl~ne.s5 ~ ~ ~ ~ ~ ~ ~> ~ ~. ~ ~' ~~ ~ ~. ~ ~. ~ `~ ~" ~ ~ r'* ~---- .'-~+ . .~. ,~