Loading...
HomeMy WebLinkAboutMiscellaneousq~~~~; COLLEGE STATION P. O. Box 9960 1101 Texas Avenue Tel: 409 764 3500 September 30, 1997 Hester Engineering Attn: Mike Hester 7606 Eastmark Suite 253-B College Station, Texas 77840 Dear Mr. Hester: College Station, TX 77842 This letter should give guidance regarding the water and sewer service for the proposed development of 4 residential lots fronting on Banks street. A 6" water line should be extended across Banks street to the proposed development.. This 6" line should be extended to the end of the property at the intersection of Banks and Churchill. Leave a 6" valve with a short length of plugged pipe at the above mentioned intersection so that the City can extend the water line to Tarnow Street in the future. The City of College Station requests that the construction plans for this water line extension show a Fire hydrant to be installed by the City of College Station'at the intersection of Banks and Churchill. Please note on the plans for the contractor to contact Tony Hawley at 764-3435 at least 24 hours prior to the need for fire hydrant installation. The City of College Station as part of a capital improvements project is planning to extend the 6 inch water line from the proposed development to Tarnow Street. As a part of this project the City will be abandoning the existing 2 inch line on the North side of Banks Street. To facilitate this project, the City is requesting that service taps be placed on the construction documents for the new 6 inch line. Lawrence Carter will be sending you a map showing where these additional service taps will be located. If you have any questions, please call me at 409-764-3570. Sincerely, W. Paul Kaspar Graduate Civil Engineer xc: ~eronica Morgan, Assistant City. Engineer Lawrence Carter, Superintendent of Water/Wastewater Distribution Shirley Volk, Development Coordinator Tony Hawley, Water/Wastewater Distribution Home of Texas A&M University :.~i~4~~~~C~2.~_ STAFF NOTES Churchill Estates, Lots.1-4, Block 1 Case #97-236 Ordinance Requirements: Replace the "Approval of the City Engineer and City Planner" signature block with the "Approval of the City Engineer" signature block. Add a signature block for the Planning and Zoning Commission. Parkland dedication in the amount of $675 ($225 x 3 units) will be required prior to the plat being filed for record. Remove the second sentence in general note #1 pertaining to the 10' side street setback requirement. Remove general note #3. Submit paid tax certificates. Comments/Concerns: Coordinate telephone s~erv~ice details with G.T.E. Representative Laverne Akin. at (409) 821-4723.~~~~ ~-~ti ~~~~'~~u -G~ ~~~ Coordinate electrical service details with Electrical Operations Coordinator Tony Michalsky at (409) 764-3660. SUBMIT THE REVISED MYLAR ORIGINAL AND 10 COPIES BY WEDNESDAY, OCTOBER 29, 1997 TO BE INCLUDED IN THE PLANNING AND ZONING COMMISSION PACKETS FOR THE MEETING QF THURSDAY, NOVEMBER 6,; 1997 AT 7:00 P.M. IN THE CITY HALL COUNCIL ROOM AT 110.1 TEXAS AVENUE SOUTH, .„... ;Shirley. Volk:-,Re Plattmglbuilding.questions..:... ...,..... :.::::,..:::.:...::..»..:.,.::.::.:: .....:::.::::::.,,.:.:........:::.:_.,..:......:..::..::::::......:: Page.: ~.' From: Sabine McCully To: Jane Kes, Lee Battle, SVOLK@City of College Stat... Date: 5/21 /98 10:33AM Subject: Re: Platting/building questions just talked with him to get him started in the right direction. basically, what you told him was. correct, shirley, since wer are dealing with three intact lots with no illegal subdivisions in and of themselves. cautioned him about any possible utility coordination problems if he .gets permits before replatting. he's going to get a surveyor involved to help them_ in their work. »> Shirley Uolk 05/20/98 04:09PM »> Randy (CD) just called and asked ME (of all people).the. following question: If one owner owns 3 lots but wants to build only 2 houses on those 3 lots must he replat? My answer was that 1 think that owner can build over lot lines, but before he sells either house, he must replat. Would one of you please either verify or correct my answer. Thanks. CC: Natalie Ruiz, Randy Brumley ACCOUNT NO. .CITY OFbCUOLLEGE STATION ~ Q 9 2 ~ ~ $ ~~~ . - ( ~ , 19~_ RECEIVED OF_ c./lt! VP.f ~l ~ /7~ ----_ Paid by_ ~nrii~n iVU ~/ 1 6013.. ~~-..° e° -KERR SURVEYING CO: A7 P: O. BOX 269 PH. 409-268-3195- ///[[ ....,COLLEGE STATION, TEXAS 77841 _ /fD ~~ _ ~-'] 88-232/ 1131 PAY f ~, ~ /~ DATE L ` / ORDER OF ~~ ~~( B ~ ~~0;~ '~C~l~` % f~ + I ~ (JD '" ~=^ " / a ,/ ~ ~~ ~ CY>~v -DOLLARS Ba m~ FIRST /vim ~~nerican ~BAIYK"Pa ~x,~ BPYAN, TFXP$ ]lam ~-(409) 280J300 f~rsCGL- ~S sa k, SS6 c{-' (/Qf'~ ~U~S~ ' FOR. ~~ f s M, - -- - - --- u'0060 L 3ii'~ a-,~ 13 L0 2 3 2qi u^ 240 3 ,$B0 `8 u' '-:: GTE COMIIEN'I'S C:11 Y Off' (:OLL1T':(iE ~ T A 1 lOPI, TEI4AS Ti9 !\ iT /`IT TTi l 1 !'~Pf~ .il. ~TTTTT rxv.~~c.t ~vir.w cJviviiviit ter. OCTOBER 08,1997 FINAL PLAT -CHURCHILL ESTATES;, PROPOSED SUBDIVISION TOTALING 0.48 ACRES DIVIDED INTO FOUR SINGLE FAMILY LOTS LOCATED ALOI~TG THE SOUTH SIDE OF BANKS STREET. AND BETWEEN CHAPPEL AND CHURCHILL (97- 235} GTE COMMENTS: NO PROBLEM VVITII THE FII\TAL PLAT IF YOU HAVE ANY. QUESTIONS, PLEASE CALL ME AT 409/821-4723. THANKS, LAVERNE AKIN N 1 '~.. _J ~~„~ V s ,~, .a.., ^~ '". ;~ PRESUBMISSION CONFERENCE REPORT October 13, L997 TO: :Oakwood Custom Homes 1911 Texas Avenue, College Station, TX 77840 Brad Kerr, Kerr Surveying 505 Church Street, College .Station, TX 77840 FROM: Presubmission Conference Jane Kee, City Planner Veronica Morgan, Assistant City Engineer , Ron Silvia, P&Z-Representative. Others Attending Natalie Ruiz, Planning Technica Tony Michalsky, Electrical Operations C rdinator .SUBJECT: Final Plat -Churchill Estates; proposed .subdivision totaling 0.48 acres divided into four single .family lots located along the south side of Banks Street between Chappel and Churchill. X97-236) A Presubmission Conference meeting was held Wednesday, .October 8, 1997 to discuss the above mentioned final plat..: The, following is a list. of ordinance requirements identified. by the Presubmission Conference. This list does'not relieve the applicant of total compliance with all current ordinance requirements.. Ordinance. Requirements: _ Replace. he "Approval of the City Engineer and City Planner" signature block with the "Approval of the City Engineer" signature block. _ Add a signature block for the Planning and Zoning Commission. _ Parkland dedication in the amount of .$675 ($225 x 3 units) will be required prior to the plat being filed for record. _ Remove. the econd sentence in general note #l pertaining to the 10' side street setback requirement.. Remove general note #3. _ .Submit paid tax certificates. ~. PRC Report Churchill Ests. Case #97-236. Page 2 of 2 '' Comments/Concerns: _ Coordinate telephone service details with G.T.E. Representative Laverne Akin at (409) 821-4723. The developer is responsible for conduit installation and 20% of the total cost of electrical service: Coordinate electrical. service details with: Electrical Operations Coordinator Tony Michalsky at (409): 764-3b60. SUBMIT THE REVISED MYLAR ORIGINAL AND 10 COPIES BY WEDNESDAY, '' OCTOBER 29, 1997 TO BE INCLUDED IN THE PLANNING AND ZONING COMMISSION PACKETS .FOR THE MEETING OF THURSDAY, NOVEMBER 6, 1997 AT 7:00 P.M. IN i THE CITY HALL COUNCIL. ROOM AT < 1101 TEXAS. AVENUE SOUTH.