HomeMy WebLinkAboutApplicationP&Z Case No. " "a/'7
Date Received
APPLICATION FOR PLAT REVIEW AND APPROVAL
(check one)
Amending Plat XX Final Plat
Master Prelim. Plat Prelim. Plat Replat Resubdivision
NAME OF SUBDIVISION IDELWEISS ESTATES, PHASE 4-B
BEGONIA CORPORATION Mr. Steve Arden
OWNER AGENT BRAZOSLAND REALTY
ADDRESS 1901 .San Jacinto.
ADDRESS 4103 S. Texas Ave., Suite 100
Houston, TX 77002 Bryan, TX 77802
PHONE (713) 654-0060 PHONE 846-5735
Michael McClure P.'E.,R.P.L.S. 776-6700
LICENSED SURVEYOR /ENGINEER McCLURE ENGINEE~tING, INC. PHONE
ADDRESS 1722 Broadmoor, Suite 210, Bryan, TX 77802 __
PROJECT MANAGER
ADDRESS
SPECIFIED LOCATION OF PROPOSED SUBDIVISION
ESTATES, PHASE 4-A
PHONE
located directly southwest of EDELWEISS
11 .96 Ac. TOTAL ACRES OF SUBDIVISION 2.77 Ac. R-0-W ACREAGE 50
FOR FINAL PLATS ONLY:
TOTAL LINEAR FOOTAGE OF:
2217 L.F. STREETS
2857 L.F. SIDEWALKS
985 L.F. SANITARY SEWER LINES
2016 L.F. WATER LINES
NUMBER OF LOTS BY ZONING DISTRICT R-1 : 50 Lots
AVERAGE ACREAGE OF EACH RESIDENTIAL tOT BY ZONING DISTRICT:
TOTAL # OF LOTS
R-1: 0.1'84 Ac.
FLOODPLAIN ACREAGE 0 PARKLAND DEDICATION ACREAGE 1 FEE
REQUESTED VARIANCE TO SUBDIVISION REGULATIONS
IS FILE AVAILABLE IN AUTOCAD'? yes
THE UNDERSIGNED HEREBY REQUESTS APPROVAL. BY THE CITY OF COLLEGE STATION OF THE
ABOVE IDENTIFIED PLAT:
c `'C~ ~~8~97
Sig ture and itle P,eol~cT E.v4.u/ea~ .Date
~..,.w.~~...~-,.
. MINIMUM RE UIRENIENTS FOR T BE MET TS
ES
~
RDINANC
ALL CITY
TO TI-IE IF'OLL~WING:
INCLU~ING BUT NOT LIMITED
equirements based on field survey and marked by monuments and markers)
~j' 1 Drawn on 24" x 36" sheet to scale of 100` per inch.
. a, vicinit .map which includes enough of surrounding area o Ihuonts eNo scale tequred
y in relationshi to College Station-and its C ty
p
subject property.
~-
2. but include north arrow. Tanner, en ineer and urveyor.
Name & address of subdivider, recorded owner, p g
~- 3, Name & address of all lenders on the property.
0'`f 4 Name. & address of all easement holders.
.
p~ 5. -Proposed name of subdivision (not' spelled or pronounced similarly to any other subdivision
in Brazos County, Texas):
p/' 6. Date of preparation, scale in feet and north arrow:
7.
` Application fee.
g
. Construction documents on 24" x 36" sheets.
9. Paid tax certificatesfrom City of College Station, Brazos County and the C.S.I:S.D.
~~ 10. Tgta1 area intended to be developed.
(~ 11. Subdivision boundary lines indicated by heavy lines..
G~ 12. Certificate of Ownership &.Dedication;
.Certificate of Surveyorshtp and/or Engineer;
Certificate of City Engineer;
Approval of Commission;
Approval of City Council;
Certificate of the County Clerk.
(Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration).
t~Y 13. Number of lots.
p, a. number of lots by Zoning District.
~ b.-.average acreage of each residential lot by Zoning District.
~~ 14. Approximate area of street right-of-way_
15. Proposed parkland. dedication information. _
~- 16. Requested oversize participation items, if any.
17. Location of the One Hundred Yr. Floodplain according to the most recent available date.
- 18. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch.
i
19. Exact location, dimensions, name and legal description of all existing or recorded streets,
alleys, reservations, easements or other R.O.W. within the subdivision, intersecting or
contiguous~with boundary or forming boundary with accurate dimensions, bearings or
deflection angles and radii, area, center angle, degree of curvature, tangent distance and
length of all curves.
20. Same information for proposed streets, alleys, etc. as preliminary plats.
l~~ 21. Lot corner markers and survey monuments (by symbol) and tied to basic survey data.
~~ 22. Street, alley, and sidewalk plans, profiles and. sections, with specifications and detail cost
estimates.
fit" 23. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades,
with cost estimates.
24. Water line plat showing fire hydrants, valves, etc.. with specifications and a detailed cost
estimate.
~~ 25. Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer and
drainage channels, with profiles and sections, and showing drainage and runoff areas, and
runoffbased on 5, 10, and 25 year rain intensity. Detail drainage structure design and
~f 5 channel lining desigm if used, with specification and detail cost estimate:
(~j~~~0 26. Street lighting plan showing location of lights, design, and with specifications anti detail cost
estimate.
h\t~' 27. .Submit a statement addressing any differences between.the final plat and approved Master
Preliminary Plat & Plan.
28. Indicate any variances requested and reasons for same.
y~~- 30. Are there impact fees associated with this development?
~~"' 31. Add a general note that no private sewage facility may be installed on any lot in this
subdivision without the issuance. of a license by the Brazos County Health Unit under the
:provisions of the private facility regulations adopted by the Commissioners Court of Brazos
County, pursuant to the provisions of Section 21.004 of the Texas Water Code.
r~~wpta~s-ss -