HomeMy WebLinkAboutApplicationP&Z Case No
.. .~ ~ ~ Date Received -
a
APPLICATION FOR PLAT REVIEW AND APPROVAL
(cti.;ck one)
Amending Plat ~ Final Plat Master Prelim. Plat Prelim. Piat Replat Resubdivision
E OF SUBDIVISION EDEI'WEISS ESTATES, PHASE 19-A
NAM
Patricia Rogers and
AGENT
OWNER i]onna Winsl o~~~
1615 Emerald Lake Court ADDRESS
ADDRESS
Houston, TX 77062
PHONE 690-096;3 PHONE
Michael R. McClure P.E. R~p ~S
LICENSED SURVEYOR /ENGINEER McCLURE ENGINEERING, IN~~Hd~E ~
776 ' 6700
ADDRESS 1722 Broadmoor, Suite 210, Bryan, Texas.. 77802
PROJECT MANAGER I"~s • Donna Winslow PHONE 690-0963
ADDRESS Box 16004, IGN.Road/C~metery Road, Wellborn, TX 77881
SPECIFIED LOCATION OF PROPOSED SUBDIVISION At the northeast quadrant of the intersection
of Wellborn Road`and Mor er Drive
3.500 Ac. TOTAL ACRES OF SUBDIVISION none R-O_W ACREAGE 1 TOTAL # OF LOTS
FOR FINAL PLATS ONLY:
TOTAL LINEAR. FOOTAGE OF: n/a STREETS
n/a SIDEWALKS
', n/a SANITARY SEWER LINES
n/a WATER LINES
NUMBER OF LOTS BY ZONING DISTRICT C-3 : 1 Lot
AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT:
FLOODPLAIN ACREAGE none.. PARKLAND DEDICATION ACREAGE ~ FEE
REQUESTED VARIANCE TO SUBDMSION REGULATIONS
I$ FILE AVAILABLE IN AUTOCAD? des
THE UNDERSIGNED HEREBY REQUESTS APPROVAL BY THE -CITY OF COLLEGE STATION OF THE
ABOVE IDENTIFIED PLAT:
Sig ture an itle ~ Date
n/a
~.wti~~.,.s-v.
MINIMUM REpUIREMENTS FOR FINAL PLATS
(ALL CITY ORDINANCES MUST BE METIl
INCLI,TDING BUT NOT LIMITED TO THE FOLLdWING:
(Requirements based on field survey and marked by monuments and markers)
_ . _ _. ,_
l~`' 1. Drawn on 24" x 36° sheet to scale of 100' :per inch.
a. vicinity map which includes enough of surrounding .area to show general location of
subject property in relationship to College Station and its City Limits. No scale requred
but include north arrow.
2. ~ Name & address of subdivider, recorded owner, .planner, engineer and surveyor.
3. Name & address of aU lenders on the property.
4. Name & address of all easement holders.
5. Proposed name of subdivision (not spelled or pronounced sunilarly to any other subdivision
in Brazos County, Texas).
~. 6. Date of preparation, scale in feet' and north arrow.
~-` 7. .:Application fee. .
8. Construction documents on 24° x 36" sheets.
~"" 9. Paid tax certificates from.City of College Station, Brazos County and the C.S.LS.D.
tom" 10~ Total. area intended to be developed.
[tom"' L Subdivision boundary lines indicated by heavy lines::
L9'``~ 12. certificate of Ownership &.Dedication;
,,Q' ificate of Surveyorship and/or Engineer;
certificate of City-Engineer;
certificate of the County Clerk.
(Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration).
13. Number of lots.
tom- a. number of ots by Zoning District.
~-'" b.: average acreage of each residential lot by honing District.
14. Approximate area ofstreet:right-of--way.
' t~
~ 15. P>oposed parkland dedication information..
~ 16. Requested. oversize.. participation items, if any.
C'~` 17. Location ofthe One Hundred Yr. Floodplain according tc the most recent available date.
~ 18. If more than 1 sheet, an index sheet showing entire subdivision at a scale of S00 feet per inch.
~.
19. Exact location,-:dimensions, name and legal .description-of all existing or recorded streets,
alleys, reservations, easements or other R.O.W. within the subdivision, intersecting or
.contiguous with boundary or forming boundary with accurate dimensions, bearings or
deflection angles and radii, area, center angle, degree of curvature, tangent distance and
length of all curves.
20. Same information for proposed streets, alleys, etc. as preliminary plats.
21. Lot corner .markers and surve monuments (by symbol) and tied to basic survey data.
Y
22.. Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost
estimates.
~~` 23. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades,
with cost estimates.
24. Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost
estimate.
h 25. Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer and
,drainage channels, with profiles and sections, and showing drainage and runoff areas, and
runoffbased on 5, 10, and 25 year rain intensity. Detail drainage structure design and
L channel lining design if used, with specification and detail cost estimate.
,D ~ 26. Street lighting plan showing ocation of lights, design, .and. with specifications and detail cost
estimate.
~' 27. Submit a statement addressing any differences between the final plat and approved Master
Preliminary Plat & Plan.
r~~l~~'~28. Indicate any variances requested and reasons for same.
n~-,/ 30. Are there. impact fees associated with this development?
n 31. Add a general note that no private sewage facility maybe installed on any lot in this
subdivision without the issuance of a licenseby the Brazos County Health Unit under the
:provisions ofthe,private facility regulations adopted by-the Commissioners Court of Brazos
County, pursuant to the provisions of Section 21.004 of the Texas Water Code.
~«n.~.,~.~..9s .