Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Miscellaneous
SUBMIT APPLICATION AND THIS LIST CHECKED-OFF WITH l6 FOLDED COPIES OF SITE PLAN FOR REVIEW MINIMUM REQUIIZEMENTS FOR SITE PLAN PROPOSALS ALL CITY ORDINANCES MUST BE MET) INCLU~ING BUT NOT LIMITED TO THE FOLLOWING: ^ 1. Sheet size - 24" x 36" ^ 2. Title block to include: . a.) Name, address, location, and legal description b.) Name, address, and telephone number of applicant c.) Name, address, and telephone number of developer/owner d.) Name, address, and telephone number of architect/engineer e.) Date of submittal £) Total site area ^ 3. Ownership.. and current zoning of parcel and all abutting parcels. ^ 4. A key map (not necessarily to scale)., ^ 5. Scale should be largest standard engineering scale possible on sheet. ^ 6. Provide a north arrow. ^ 7. Topography, final grading plan, and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) ^ 8. All existing streets, drives, buildings, and water courses on or adjacent to the proposed project site. ^ 9. Locate 100 yr. floodplain on or adjacent to the proposed project site, note if there is none on the site. ^ 10. Location and size of existing utilities within or adjacent to the proposed project site. ^ 11. Proposed location, type, and size of the'fol(owing: a.) Buildings and structures b.) Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned c:) Sidewalks d,) Common open space sites e.) Sites for solid waste containers ^ 12. Proposed streets, drives,. and curb cuts. For each proposed. curb cut (including driveways, streets, alleys, etc.) locate existing. curb cuts on the same and opposite side of the street to determine separation distances between existing and. proposed curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See-0rdinance 1961 for driveway location and design requirements.) ^ 13, The total number of residential buildings and units to be constructed on the proposed project site. ^ 14. Landscape plan as required in Section 11 of the Zoning Ordinance{See Ordinance # 1638.) The landscaping .plan can be shown on a separate sheet if too much information is on the original site plan. Attempt to reduce or eliminate plantings in easements.. Include information on the plan such as: a) existing landscaping to remain b) required point calculations c) proposed new plantings with points earned ^ 15. Indicate unit type (number of bedrooms). ^ 16. The density ,of dwelling units per acre'of the proposed project. ^ 17. The gross square footage of buildings and the proposed use of each building. ^ 18. Designate number of parking spaces required by ordinance and provided by proposal. ^ 19. Show dimensions to size and locate all structures, parking spaces, drives, curb. cuts, parking islands, and setbacks. ^ 20. Are there impact fees associated with this development? ^ 21. Provide a water and sanitary sewer. legend to include. water demands (minimum, maximum and average demands in gallons per minute) and sewer loadings (maximum demands in gallons per day). ^ 22. Show all meter locations and note their sizes. The following are typical standards for Plan Development established by Ordinance or Policy: ^ 1. Building separation is a minimum of 15 feet. ^ 2. Building setbacks are outlined in Ordinance 1638, Zoning Ordinance, Table A (Sec. 7, P. 30). ^ 3. Minimum parking space is 9' X 20', or' on a perimeter row, 9' x 18' with a 2' .overhang. ^ 4. Minimum drive width is 23' with head-in parking or 20` without parking. ^ S. Raised landscaped islands, (6° raised curb) of a minimum of 180 sq. ft. are located at both ends of every parking row. Additionally, 180 sq. ft. of landscaping for. every 15 interior parking spaces must be provided. ^ 6. Streetscape compliance is required which involves special plantings along streets specified in the City's Streetscape Plan. ^ 7. A 6" raised curb is required .around all edges of all parts of all paved areas without exception. (To include islands, planting areas, access ways, dumpster locations, utility pads, etc.) Curb detail to be approved by City En ig~neer. No exceptions will be made for areas designated as "reserved for future parking" ^ 8. Wheelstops maybe required on interior rows longer than 10 spaces or in special situations. ^ 9. Sidewalks are required at time of development if property has frontage on a street shown on the sidewalk Master Plan or if the Project Review Committee determines the necessity. (Refer to Section 10..2 of the Zoning Ordinance).: ^ 10. Locations of dumpsters shall be such that dumpsters are not visible from streets. Gates are discouraged and visual screening is required.. ^ 11. Healthy, native trees over 6" in caliper should be retained whenever possible. ^ 12. Fire lanes of a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any structure of any type is more than 150 feet from a public street or highway. ^ 13. Any structure: in any zoning district other than R-1, R-lA, or R-2 must be within 300 feet of a fire hydrant as measured along a public street or highway. ^ 14. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer.. ^ 15. Fire hydrants must be operable and accepted by the City and drives must have an all weather surface before a building permit can. be issued. ^ 16. A twenty four. foot setback from R.O.W. to curb of parking lot is required. Parking may be allowed in this area up to a maximum of 7 contiguous spaces. ^ 17. All .plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and must be sized accordingly and include backflow prevention protection. i CHECKLIST FOR P.R.C. REVIEW OF SMALL AND/OR PORTABLE STRUCTURES [Setbacks OK? Zoning OK? ~ ~ ~ (Easements OK? ~' i,' ,~ ~~','~',~t :, ~~~~,~,.;u. ~, t~~a ~;.-.w,~,.~, . ~:. Parking lot conforms? Parking space useage less than excess parking available? °~'~County Health Department approval? 'Agreement with host "site for. restroom facilities? `Agreement for trash pick-up? ~'.::i ^ All parts of building within 300' of fire hydrant? ~ - ~' ~ , J/g Ar.. ^ Anchored properly? ~` ~~-~~'~'r'p' ~.~`" { ^ Landscaping OK according to Northgate standards? ~""- ~~("J Bond posted in the amount of $500.00? Chandler J SI 115 g 3201 Manor Way Dallas, Texas 75235-5909 s~~' 214/902-2000 TRANSMITTAL DATE April 23. 1996 WORK ORDER # P R O J E C T Nat ionsBank ATM ADDRES S 2501 Texas Ave.- College Station, TX TO Development Services - City of C.S. 1101 Texas Ave. College Station, TX 77842 Attn: Sabine Kuenzel We are sending the following material(s) enclosed x Under separate cover ine # ~ No. of Copies Description of Item Action Requested O1 4 961510 R1 "Footprint" drawing 02 4 960947 R1 awning drawings including shop elec rical details _ 03 4 952487 R4 ATM surround bldg. drawings 04 4 revised site plans showing new island location 05 06 ACTION REQUESTED: For your use ~'----Fe-r--yv-o' . record s 3. For your approval 4. As requested 5. Review and comment 6. Other REMARKS SENT BY: Our Messenger Your Messenger Mail Other Federal Express CS-108 B Y = ~~~ APR 24 '96 17 01 FR LINCOLN PROPERTY CO. 713 222 1418 TO 14097643496 P.01 LINCOLN PROPERTY Co ~ . TO: COMPANY: FAX NO.: FROM: ~co Az, cow s~e~r DATE: ?~~ ~~ 5~'81~~. 1~CU X11,5 .~L Number of Pages, incIading this coFer sheet: Z RE: ~ ~ZfC ~f~ PLA~~ S~. - /~~7~s'BArUX ~'1 co~rrrs: ~~ ~s ~- sm~ pct s~~nl~ . ,s~R~Cf/r,,~, Ply ~inF~zr' ~F 7~}€. t~~LbC, file ~R ~, 7~:E. 1sL,A/11D 'e In case of a problem with this tr~~~~oa, please call (?13) 22Z-1300 i.Q~1CO1~N P1tO~TY COMPANY 700 tpUL'4tANA BURS 610 HOUJI~K,'[X 77002 (713) 27~-i300 1113) ~-1i1=FACSO4L8 APP. 2~1 '96 1701 FP. LIhICOLhI PP.OPEP.TY CO. 713 222 S~lE TO 1109?6~13~196 P.02 Z0 "3Jt1d ~0 : LT 96: 6T ~Idt1 200 ' d ~H.LOl q~ ~ ~ r , ~. ~~ e! 1 i ~~ ~~ ~~ ~~ 0 EOUf~MIESf iARCW~T Ny Ire • we „re..we I ~ ~ ~ ~Ori~~e ~ w+xe~••Ot~~> ~y ~ ~ ff ~~ ~ . I3~e~~3~ t ~~~~~&~~~~~~~ ~ ' ~ a +Kaan~t d aaa~adnn~ann+~ l f ~ ~ Park Place Plaza ' !~ ~ 7501 Teza~ ire - GG~epS 9ta~a1 Tosa7 ~~~ -r . - ~ ~ ~ GQDi GHQ ~d SUGjS z{31Qr~ri~+~ .... TPTN aar~ no ~. RQ:~',Z ~3C~Gi GT `1~I w~: TOTf1L Pf1GE. ©~ :vw From: To: Date: Subject. y, p , c~'~ ss~o Parking Lot. Plan - Nations Bank ATM Facility (96-409): No prob~~m Final Plat - Southwood Valley Section 5-A (96-200): No problem. Final Plat - Culpepper Plaza Addition (96-213): No problem Thanks!! `• CITY OF COLLEGE STATIOI~I mth ® Ha1l.sxuENZEL PLANNING DIVISION X96 4: 02~ST OFFICE 80pX 9960 1101 TEXAS AVENUE Wednesda A rlLLEGE ST T TEXAS 77842-9960