Loading...
HomeMy WebLinkAboutStaff Report STAFF REPORT Case No.: 96-307 Request: Preliminary. plat of approximately 70 acres .consisting of .two reserve tracts zoned A-O and R-1 and 23- lots proposed for R&D zoning,. 17 of which are not to be buildable lots. The property is located in the southeast quadrant of the Sebesta Road and Highway 6 intersection. Applicant: Bill Scarmardo for Texas Digital Systems ITEM SUMMARY AND RECOMMENDATIONS The layout of this plat is in accordance with the preliminary plans that have been agreed to by the area homeowners and City Staff. The applicant is requesting a variance to the subdivision regulations that require all lots to have access and utilities. The lots that. do not .meet these standards for subdivided lots are those noted as "unbuildable". These 17 lots will provide the buffer area. between this development and Woodcreek Staff recommends approval of variances. for the 171ots. The property has been recommended for R&D zoning by the P&Z and will. be considered by the City Council June 27th. Staff anticipates no problem with the rezoning of the property, and the plat shows compliance with the pending. zoning. Staff recommends approval with presubmission conference corrections relating to the clarification of lot numbers,. with a change in the title block to reflect the correct acreage and phases, and with the condition that the property be rezoned before the plat is considered approved.. ZONING AND LAND USE Subject Tract: R-1 and A-O (rezoning to R&D scheduled for approval 6-27); vacant North: C=1 General Commercial; vacant East: A-O; vacant South: R-1; developed as Emerald Forest Subdivision West:. R-1; vacant Proposed Use: Research and development COMPREHENSIVE PLAN Land Use Plan:. Currently, the Land Use Plan is in transition for the area. The planning consultants have studied the area and have met with the homeowners groups. The latest draft of the proposed plan indicates mixed use for the ~~ intersection. to the west of the subject tract. and light industrial for the subject property. Thoroughfare .Plan: Sebesta Road is reflected as a collector and there are no street connections shown through the subject tract. Development Policies:. The request meets.. development policies of planned industrial being .compatible with residential uses if appropriate performance criteria such as buffering, height control, and noise and light controls are in place. The new R&D ordinance contains these standards. Parkland Dedication: None required ENGINEERING Water - Water is currently not provided to these areas. It will have to be extended in accordance with the utility master plan. The applicant .will need to extend a 12" waterline through the property from Sebesta Road to the most southerly property line.. Impact studies have shown that the development could be served by a 10" waterline and they have requested oversize participation in the difference between the 10" and 12" lines. The City of College Station does not accept 10" lines within its water distribution system, as this pipe size is not considered standard and the pipe itself and fittings are difficult to obtain.. Given that we do not accept the TO" size, and that the. cost differential between a 10" and a 12" is nominal, staff does not :recommend oversize participation. Sewer -Sewer is not provided to these areas. It will have to be extended in accordance with the utility master .plan. Sewer will be extended from the Foxfire area and will be .sized and located to provide sewer to the parcels outside this development. Streets -The only frontage for this property is on Sebesta Road. However, it has been agreed that access will be taken through an access road extending from the Bypass.Frontage Road to the subject tracts.. Drainage -Drainage is currently overland and will be addressed with the platting and development of the property. Flood Plain - A floodplain analysis does not have to be performed on this property per FEMA. This property is not located in the 100-year floodplain. NOTIFICATION: N®ne required