HomeMy WebLinkAboutMiscellaneous. TAOIO
OLLEOE S N
C
P. O. Box 9960 1101 Texas Avenue College Station, TX 77842
Tel: 409 764 3500
August 5, 1997
George Mcllhaney
1512 Holleman
College Station, Texas 77840
Dear Mr. Mcllhaney,
This letter is in response to your letter dated July 14,1997 regarding an extension on the
preliminary plat ofthe O.C.,Cooper Place Subdivision. A six month extension is hereby
granted as stated in .the City of College Station Zoning Ordinance. If you have any
further questions :please do not hesitate to contact the Planning Office.
Sincerely,
/ ~ .
Ja R. Kee
Planner
Home of Texas A&M University
July 14, 1997
College Statiion
Jane Key
City Planner
City of College Station
Ms. Key:
I am writing: per my conversation with Shirley Volk today regarding an extension on the
preliminary :plat of the O.C. Cooper Place subdivision. If there is any problem with this,
please let me know.
Thank you.
Sincerely,
---,-~Y~
George McIlhaney
1512 Holleman
College Station
693-3313
764-3097 fax
Staff Project Review Committee Meeting
May 22, 1996
PRELIMINARY PLAT (96-306)
O. C. Copper Place
Requirements
Underground service required.
:Electric Service. Request Form (see attached). fill out and return.
Developer is responsible for 20% of the cost of electrical service.
Developer installs all conduit per city design andrequirements on property.
The: city will do an electrical layout showing proposed service to property
and provide developer a copyfor installation of conduits.
Additional easements may be necessary to serve property.
Developer is responsible for the installation of streetlights per city design.
Additional 5 ft easements may be necessary between lots to serve
lights.
Residential standard streetlight is 30 ft mounting height with a 8 ft arm
and a 100 watt cobra head fixture...
Thoroughfare: standard streetlight is 42.5 ft mounting .height with a 15 ft
arm and a 200 watt cobra head light.
Others
Show any existing power -poles and lines on property.
Y ~~
~'
MINIMUM RIJQUIREMENTS FOR PRELIMINARY PLATS
(ALL CITY ORD[NANCES MUST BE MET)
INCLUDING :BUT NOT LIMITED TO THE FOLLOWING:
~ 1. Name & address of subdivider, recorded owner, planner; engineer and surveyor.
!~~ 2. Name & address of all lenders on the property.
~`A 3. Name & address of all easement holders.
4. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision
in Brazos County, Texas).
~5. Total area intended to be developed.
~~ a. .key map (vicinity. map) not necessarily to scale.
^ 6. Number of lots
q--°"~`~ a. number of lots by Zoning District.
II ~ ~ b. average acreage of each residential lot by Zoning District.
o'"
im area of street right-ot=wa .
7 A rox ate
PP ~ y
'i'I _..~;,p ^ 8. Proposed parkland dedication.
'~
9. Requested oversize participation items, if any. '
^ 10: Proposed MASTER DEVELOPMENT PLAN which includes: '
a. proposed land uses, including but not limited to street rights-of-way;
proposed zoning changes;
c. proposed drainage. development;
II~, ~' d. proposed. public improvements, including but not limited to parks, schools, and
~ other public facilities; '
e. proposed utility services (water and sanitary sewer).
/~ I L IMPACT STUDIES (traffic, electric, water, sewer and drainage) quantifying the increased
`/ demands that will be laced on -the s stem. as a result of the ro osed develo ment, including
P Y P P P
areas not designated for immediate development
^~~ 12. Application fee.
13. Preliminary plat drawn on 24" x36" sheets at a scale of not less than n l00 feet per inch and
including the words _"PRELIMINARY PLAT.- NOT FOR RECORD" in letters 1/2" high.
(When more than one sheet is`necessary to accommodate the entire area, an index sheet at
appropriate scale showing the entire area shall be attached, (INCLUDE DATE THE PLAT
WAS SUBMITTED AND THE DATES OF ANY REVISIONS ON THE PLAT).
! 14. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted:
15. Descriptions by metes and bounds of the subdivision which shall close within accepted land
survey: standards.
i~
F~ ^ / 16. Primary control points or descriptions and ties to such control point, to which, all dimensions,
`./ angles bearings, block numbers, and sihtilar data shallbe referred (later). The plat shall be
located with respect to a corner of the survey or tract, or an original corner of the original
E survey of which it is a part.
17. Subdivision boundary lines indicated by heavy lines.
r„_..`~;,~ j~ 18. Location of the One Hundred Year Floodplain according to the most recent available
information:
19. Date of preparation, scale in feet and north arrow.
l ^ 20.
~
' Topographical information, including contours at 2 foot intervals, flow line elevation of
e
';i d areas.
streams, and wood
21. Location, approximate: dimensions, descriptions and name of all .proposed streets, alleys,
drainage structures, parks or other public areas, reservations, easements or other rights-of-
way, blocks, lots and other sites within the subdivision,
^~~ 22. Proposed drainage channel cross sections, if any.
23. Existing and/or proposed well site locations.
24. A number or letter to identify which lot or site and each block.
~- ~ 2S. Location of current city limits line and current zoning district boundary.
26. Ultimate primary system destination of storm water for a distance of at least one quarter
vi
i
d
on, an
s
mile down stream and possible storm sewer, water, gas, telephone, cable tele
electric and sanitary sewer-`connections.
~~27. All streets must be continuous or end in a cul-de-sac.
^ 28. Indicate any variances requested and. reasons for same.
(om~s\plan\pl implat\8-95
y.:.:
µ~. y -
P&Z Case No.
Date Received
APPLICATION FOR REVIEW AND APPROVAL
PRELIMINARY PLAT
'"~~Master Preliminary Plat & aster Plan
Name of Subdivision ~ ~ Q
Preliminary Plat
***SUBMISSION OF THIS APPLICATION IS NOT COMPLETE UNTIL PLATTING FEES
ARE PAID AND ALL REQUIREMENTS OF ORDINANCE #690 HAVE BEEN MET. ***
MINIMUM REQUIREMENTS:
l . Filing Fee of $200.00
2. Application completed in full.
3. Sixteen (16) folded copies of plat plus film positive ofsame drawn to a scale of not less
than 100 feet per inch. The words "PRELIlvIlNARY PLAT -NOT FOR RECORD"
shall appear on the plat in letters i/2" high. Date of plat and dates of any revisions shall
legibly appear on plat.
4. Master Development Plan
DEADLINE: Received in the Planning Division by noon 22 days prior to a Planning & Zoning
Commission meeting held the first and third Thursday of each month. Contact:Development
Coordinator, Shirley Volk at (409) 764-3741 for details.
* * * fee subject to change without notice
f ~ J~.
~.oa3snn~~~rag ~' angara~et°s ®~~ra~ s~nnm~eg ors
4103 Texas Avenue, Suite 212 Post Office Box 4234
Bryan, Texas 77802 Bryan, Texas 77805
`Telephone 409/84Cr6212
Fax 409/846-8252.
_B J. Kling, P.E., R.1?.L.S.
S.M. Kling, R.P.L.S.
July 30, 1997
TO: City of College Station Planning & Zoning Commission
~!°°°°`
FROM: S. M. Kling- acting on behalf of Dr. George Mcl h~~ry~r~-°-
~ RE: Preliminary plat of the 0. C: Cooper Tract.
This is a request to extend the time for which the above referenced preliminary
plat is applicable.
A final plat on the Mcllhaney - 1.38 acre tract. should be submitted in the next
~ 4 - 6 weeks.
i ,
',
i
f
9
y
j
p~
1
i
i
i
E
i
i