Loading...
HomeMy WebLinkAboutMiscellaneous. TAOIO OLLEOE S N C P. O. Box 9960 1101 Texas Avenue College Station, TX 77842 Tel: 409 764 3500 August 5, 1997 George Mcllhaney 1512 Holleman College Station, Texas 77840 Dear Mr. Mcllhaney, This letter is in response to your letter dated July 14,1997 regarding an extension on the preliminary plat ofthe O.C.,Cooper Place Subdivision. A six month extension is hereby granted as stated in .the City of College Station Zoning Ordinance. If you have any further questions :please do not hesitate to contact the Planning Office. Sincerely, / ~ . Ja R. Kee Planner Home of Texas A&M University July 14, 1997 College Statiion Jane Key City Planner City of College Station Ms. Key: I am writing: per my conversation with Shirley Volk today regarding an extension on the preliminary :plat of the O.C. Cooper Place subdivision. If there is any problem with this, please let me know. Thank you. Sincerely, ---,-~Y~ George McIlhaney 1512 Holleman College Station 693-3313 764-3097 fax Staff Project Review Committee Meeting May 22, 1996 PRELIMINARY PLAT (96-306) O. C. Copper Place Requirements Underground service required. :Electric Service. Request Form (see attached). fill out and return. Developer is responsible for 20% of the cost of electrical service. Developer installs all conduit per city design andrequirements on property. The: city will do an electrical layout showing proposed service to property and provide developer a copyfor installation of conduits. Additional easements may be necessary to serve property. Developer is responsible for the installation of streetlights per city design. Additional 5 ft easements may be necessary between lots to serve lights. Residential standard streetlight is 30 ft mounting height with a 8 ft arm and a 100 watt cobra head fixture... Thoroughfare: standard streetlight is 42.5 ft mounting .height with a 15 ft arm and a 200 watt cobra head light. Others Show any existing power -poles and lines on property. Y ~~ ~' MINIMUM RIJQUIREMENTS FOR PRELIMINARY PLATS (ALL CITY ORD[NANCES MUST BE MET) INCLUDING :BUT NOT LIMITED TO THE FOLLOWING: ~ 1. Name & address of subdivider, recorded owner, planner; engineer and surveyor. !~~ 2. Name & address of all lenders on the property. ~`A 3. Name & address of all easement holders. 4. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). ~5. Total area intended to be developed. ~~ a. .key map (vicinity. map) not necessarily to scale. ^ 6. Number of lots q--°"~`~ a. number of lots by Zoning District. II ~ ~ b. average acreage of each residential lot by Zoning District. o'" im area of street right-ot=wa . 7 A rox ate PP ~ y 'i'I _..~;,p ^ 8. Proposed parkland dedication. '~ 9. Requested oversize participation items, if any. ' ^ 10: Proposed MASTER DEVELOPMENT PLAN which includes: ' a. proposed land uses, including but not limited to street rights-of-way; proposed zoning changes; c. proposed drainage. development; II~, ~' d. proposed. public improvements, including but not limited to parks, schools, and ~ other public facilities; ' e. proposed utility services (water and sanitary sewer). /~ I L IMPACT STUDIES (traffic, electric, water, sewer and drainage) quantifying the increased `/ demands that will be laced on -the s stem. as a result of the ro osed develo ment, including P Y P P P areas not designated for immediate development ^~~ 12. Application fee. 13. Preliminary plat drawn on 24" x36" sheets at a scale of not less than n l00 feet per inch and including the words _"PRELIMINARY PLAT.- NOT FOR RECORD" in letters 1/2" high. (When more than one sheet is`necessary to accommodate the entire area, an index sheet at appropriate scale showing the entire area shall be attached, (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES OF ANY REVISIONS ON THE PLAT). ! 14. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an indication whether or not contiguous properties are platted: 15. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey: standards. i~ F~ ^ / 16. Primary control points or descriptions and ties to such control point, to which, all dimensions, `./ angles bearings, block numbers, and sihtilar data shallbe referred (later). The plat shall be located with respect to a corner of the survey or tract, or an original corner of the original E survey of which it is a part. 17. Subdivision boundary lines indicated by heavy lines. r„_..`~;,~ j~ 18. Location of the One Hundred Year Floodplain according to the most recent available information: 19. Date of preparation, scale in feet and north arrow. l ^ 20. ~ ' Topographical information, including contours at 2 foot intervals, flow line elevation of e ';i d areas. streams, and wood 21. Location, approximate: dimensions, descriptions and name of all .proposed streets, alleys, drainage structures, parks or other public areas, reservations, easements or other rights-of- way, blocks, lots and other sites within the subdivision, ^~~ 22. Proposed drainage channel cross sections, if any. 23. Existing and/or proposed well site locations. 24. A number or letter to identify which lot or site and each block. ~- ~ 2S. Location of current city limits line and current zoning district boundary. 26. Ultimate primary system destination of storm water for a distance of at least one quarter vi i d on, an s mile down stream and possible storm sewer, water, gas, telephone, cable tele electric and sanitary sewer-`connections. ~~27. All streets must be continuous or end in a cul-de-sac. ^ 28. Indicate any variances requested and. reasons for same. (om~s\plan\pl implat\8-95 y.:.: µ~. y - P&Z Case No. Date Received APPLICATION FOR REVIEW AND APPROVAL PRELIMINARY PLAT '"~~Master Preliminary Plat & aster Plan Name of Subdivision ~ ~ Q Preliminary Plat ***SUBMISSION OF THIS APPLICATION IS NOT COMPLETE UNTIL PLATTING FEES ARE PAID AND ALL REQUIREMENTS OF ORDINANCE #690 HAVE BEEN MET. *** MINIMUM REQUIREMENTS: l . Filing Fee of $200.00 2. Application completed in full. 3. Sixteen (16) folded copies of plat plus film positive ofsame drawn to a scale of not less than 100 feet per inch. The words "PRELIlvIlNARY PLAT -NOT FOR RECORD" shall appear on the plat in letters i/2" high. Date of plat and dates of any revisions shall legibly appear on plat. 4. Master Development Plan DEADLINE: Received in the Planning Division by noon 22 days prior to a Planning & Zoning Commission meeting held the first and third Thursday of each month. Contact:Development Coordinator, Shirley Volk at (409) 764-3741 for details. * * * fee subject to change without notice f ~ J~. ~.oa3snn~~~rag ~' angara~et°s ®~~ra~ s~nnm~eg ors 4103 Texas Avenue, Suite 212 Post Office Box 4234 Bryan, Texas 77802 Bryan, Texas 77805 `Telephone 409/84Cr6212 Fax 409/846-8252. _B J. Kling, P.E., R.1?.L.S. S.M. Kling, R.P.L.S. July 30, 1997 TO: City of College Station Planning & Zoning Commission ~!°°°°` FROM: S. M. Kling- acting on behalf of Dr. George Mcl h~~ry~r~-°- ~ RE: Preliminary plat of the 0. C: Cooper Tract. This is a request to extend the time for which the above referenced preliminary plat is applicable. A final plat on the Mcllhaney - 1.38 acre tract. should be submitted in the next ~ 4 - 6 weeks. i , ', i f 9 y j p~ 1 i i i E i i