Loading...
HomeMy WebLinkAboutMiscellaneousFILE NOTE Freeman Subdivision Case #96-229 I spoke with Dwayne .Vann at Garrett Engineering and he said that Robert Todd wanted to pull the final plat for the Freeman Subdivision. Dwayne did not know why it was being pulled but he was instructed to do so, Staff reviewed the final plat on Friday, August. l6, 1996 and the comments are written on the plat drawing itself.. The plat was removed from PRC on Wednesday, August 21, 1996 and will be rescheduled at a future date. if ~ Natalie omas Plannin Technician g August 20, 1996 ,I ~I ~, k: E:>. ~• ;:b '~~'- ~ : ~; ~~ <' ~ 0 ~ ^ ., ,. ~ ._ c o d v' r ~+ ~, n n C t~D G° .~ ~ ~ "~~' ;\ ~ A ~ A ~ tD ~' '" t~,~ M~ y ~' K MINIMUM REQUIREMENTS FOR. FINAL PLATS (ALL CITY RDINANCES MUST BE MET INCLUDING BUT NOT LIMITED TO THE FOLL WING: (Requirements based on field survey and marked by monuments and markers) 1. Drawn on 24" x 36" sheet to scale of 100' per inch. a. vicinity map which includes enough. of surrounding area to show general location of subject property in relationship to .College Station and its City Limits. No scale requred but include north arrow. 2. Name & address of subdivider, recorded owner, planner, engineer and surveyor. 3. Name & address of all lenders on the property. 4. Name & address of all easement holders. C~" 5. Proposed name. of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). 6. Date of preparation, scale in feet and north arrow. l3 7. Application fee. 8. Construction documents on 24" x 36'° sheets. 9. Paid tax certificates from City of College Station, Brazos County and the C.S.LS.D. l,d' 10. Total area intended to be developed. 11. Subdivision boundary lines indicated by heavy lines. 12. certificate of Ownership & Dedication; ~'ertificate of Surveyorship and/or Engineer; certificate of-City Engineer; Approval of Commission; i y ounci ; certificate of the County Clerk. (Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration). f~ 13. Number of lots. ~/ a. number of lots by Zoning District. ~.d' b. average acreage of each residential lot by Zoning District. 14. Approximate area of street right-of--way. 15. Proposed parkland dedication information. 16. Requested oversize participation items, if any. C~ 17. Location of the. One Hundred Yr. Floodplain according to the most recent available date. .~ 18. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet .per inch. 19. Exact location, dimensions, name and legal description of all existing or recorded streets, alleys, reservations, easements or other R.O.W. within the subdivision, intersecting or contiguous with boundary or forming boundary with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves. 20. Same information for proposed streets, alleys, etc. as preliminary plats. 21. Lot corner markers and survey monuments (by symbol) and tied to basic survey data. 22. Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost estimates. 23. Sanitary sewer plat with 2.foot contours,. plan and profile lines, showing depth and grades, with cost estimates. 24. Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost estimate. 25. Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer. and _drainage channels, with profiles and sections, and showing drainage and runoff areas, and runoffbased on 5, 10, and 25 year rain intensity. Detail drainage structure design and channel lining design if used, with specification and detail cost estimate. 26. Street lighting plan showing location of lights, design, and with specifications and detail cost estimate: 27. Submit a statement addressing any differences between the final plat and approved Master ~~ Preliminary Plat & Plan. 4~'''~ 28. Indicate aany variances requested and reasons for same. ~~ l!~ 30. Are there impact fees associated with this development? [~ 31. Add a general note that no private sewage facility maybe installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the. private facility regulations adopted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code: fwms~plnWlpi~08-95