Loading...
HomeMy WebLinkAboutMinutesSTAFF PRC REPORT Cellulax One Tower Case #95-706 Discretionary Items: Provide elevation details of the proposed tower and building for the Planning and :honing Commission meeting. The Commission has the discretion to require screening. Recommendation on proposed gravel drive? Ordinance Requirements: Provide the minimum 500 points in landscaping. Fire protection must be provided to the site. A hydrant must be located within 300'' of the proposed propane tank. _ Provide the. dimensions of the. full property with the drive location and lease area dimensions. _ A drainage development .permit is required. prior to issuance of a permit. Address the culvert and provide a separate sheet to include drainage and topography information. (Provide drainage calculations and size the proposed culvert,) _ Provide existing and proposed contours- for the proposed roadway. _ Is the 15' utility :easement for electrical service and will it be dedicated by separate instrument? Correct the call discrepancy along Arrington Road. _ Are all existing utilities shown? Locks on the. entrance gate. (Veronica to talk to Fire about this requirement.) Comments/Concerns: Coordinate electrical service details with Electrical Line Designer Don Lusk at (405>) 764- 3660. Existing telephone .facilities are located along Arrington Road.. The developer is responsible for placing one 4" diameter PVC pipe with pull string from the end of the 15' utility easement to the outside termination on the building. The PVC pipe should ell up 4' at the termination point and the conduit should be :capped. The service entrance must be located within 20' of power ground and no closer than 36". If termination is not within 20' of power, an 8' x 5/8" copper: ground rod must be placed at the base of the termination point. Coordinate service details,with G.T.E. Representative Laverne Akin at (405)) 821- 4723. PROJECT REVIEW COMMITTEE REPORT. June 22, 1995 TO: David Louden, Cellular One 1120 Loop 3.60 South, Suite 100, Austin, TX 78746 Kenneth Donoughue 45 N. E. Loop 410, Suite 760, San Antonio, TX 78216 7. L. Gaut 13238 Rain Lilly Lane, Houston, TX 77083 FROM.: Project Review Committee Jane Kee, Crty Planr ri Veronica Morgan, .Ass ante. City Engineer Larry Lightfoot, P&Z Representative Others Attending Natalie Thomas, Planning: Technics: Shirley Volk, Development Coordinator Don Lusk, Electrical Line Designer Laverne Akin, G.T.E. Representative SUBJECT: Conditional Use Permit - Cellular One Tower; proposed cellular telecommunications. tower to be located on an 80' x 80' .lease site .out of ,a 24.97 acre tract in the Augustus Babille Survey on the southwest. corner of the Arrington Road and Greens Prairie Road intersection. (95-706) A Project Review Committee meeting: was held Wednesday, .June 21, 1995 to discuss thti above mentioned conditional use permit .request. City Planner Kee moved to recommend approval of the proposed use and site: plan with the following conditions: CONDITIONS OF APPROVAL: Discretionary Items: r/ ~Z. _ Provide elevation details of the proposed .tower and building for the Planning and Zoning Commission meeting. The Commission has the discretion to require screening. D~'' The proposed 20' wide, 4" base gravel drive is acceptable. The location of the gate at the facility entrance is acceptable. PRC Report Cellular One Tower Case #95-706 Page 2 of 2 The following. is a .list of ordinance requirements identified by the Project Review Committee. This list does not relieve the applicant of total compliance with all current ordinance requirements. Ordinance Requirements: ~~ _ Provide the minimum,500 points in landscaping and show plant types and location on plan. }( Fire protection must be provided to the site.. A hydrant must be located within 300' of the proposed propane. tank. ~ _ Provide the: dimensions of the full property with the drive location and lea:>e area ~~^^ dimensions. V A drainage development. permit is required .prior to .issuance of a permit. Address the culvert and. provide a separate sheet to include drainage and topography information. (Provide drainage calculations and size the proposed culvert.) mensr_o_n from the roadwa~to Greens_Prarrie Road. ~ ~ ~ ~^ Provide existing and proposed contours for the proposed roadway. ~~~. _ If the proposed 15' utility easement for electrical service is not needed, remove from the site plan. Correct the metes and bounds discrepancy along Arrington Road. Co`mments/Concerns: / The fire department has requested a knox box to be located at the entrance gates to the facility to assist in emergency access to the site. The box is not a requirement. ~`~ . _ The customer will be asked to move the service pole within 10` of the city owned power pole. The customer must also provide two 2" PVC conduits from the service .pole 36" deep to the .power pole .and three 10' stalks. of rigid conduit for the riser to go up the power pole. The customer is responsible for the service wire from the .service pole to the tower and approximately 20% of the .total cost of the project. Coordinate. electrical service details with Electrical Line Designer Don Lusk at (409} 764-3660. ~~, _ Coordinate telephone service details with. G.T.E. Representative .Laverne Akin at (409). 821-4723 . P&Z Representative Lightfoot seconded the motion to recommend approval of the use and site plan with the above mentioned conditions which passed unopposed (3 - 0). SUBMIT 10 COPIES OF THE REVISED SITE PLAN BY FRIDAY,: JUNE 30, 1995 TO BE INCLUDED. IN THE PLANNING AND ZONING COMMISSION PACKETS FOR TF~ 7:00 P.M. MEETING ON THURSDAY, JULY b, 1995. THE MEETING WII,L BE HELD IN THE COUNCIL .ROOM OF THE COLLEGE STATION CITY HALL LOCATED AT 1101 TEXAS AVENUE. SOUTH.