HomeMy WebLinkAboutApplication
NAME OF PROJECT
SITE PLAN REVIEW APPLICATION
DATE t~la~Er~~R ~S ~°~~
P&Z CASE NO. ~ + 1 t
~/.29
~~Residential
Commercial
ADDRESS -~ ~ I__U~.~ I ~~----~ ~~ 't-~.~ ~~'`~~---~~ 1`0~ Imo. ~'f~"~ '~
LEGAL DESCRIPTION ~.~ll~~~~1 PAI~~ C~l~#~ '~1 I°~T~ I ~- a
REST DENTI A L
Total Acreage , 9~
Housing Units ~__
#I Bedrooms > I32 sq. ft.
~ Bedrooms < 132 sq. ft.~f
ADDRESS
PHONE
PROJECT MANAGER. ~5~1'~~ PHONE
ADDRESS _._-!- ---
ARCHITECT OR ENGINEER ~p~M~ _ __ PHONE
ADDRESS
PRESENT USE OF PROPERTY ,E~P,~A~f~`~ _.
PROPOSED .USE OF PROPERTY ~~~I ~El ',~
CURRENT ZONING OF PROPERTY
VARIANCES} REQUESTED AND REASON(S)
NUMBER OF PARKING SPACES REQUIRED
NUMBER OF PARKING SPACES PROVIDED
Signature of caner, Agent or Applicant
COI~~t I~~IERC [ A L
Total Acreage -
Building Square Feet _
Floodplain Acreage _
~.C~~
Date .
(.ainal~iLa N.ilcrty/({-45
q
': ~
'~ SUBMIT APPLICATION AND THIS
LIST CHECKED-OFF WITH 16
FOLDED COPIES OF SITE PLAN FOR REVIEW
MINIMUM REQUIREMENTS FOR SITE PLAN PROPOSALS
(ALL CITY ORDINANCES MUST. BE MET)
INCLUDDING BL1T NOT LLMITED TO THE FOLLOWING:
^ 1. Sheet size - 24" x 36"
^ 2. Title block to include:
a.) Name, address, location, and legal description
b.) Name,. address, and telephone .number of applicant
c.) Name, address, and telephone number of developer/owner
d.) Name, address, .and telephone number of architect/engineer
e.) Date of submittal
f) Total site area
^ 3. Ownership and current zoning of parcel and all abutting parcels.
^ 4. A key map (not necessarily to scale).
^ 5. Scale should be largest standard engineering scale possible on sheet.
^ 6. Provide a north arrow.
^ 7. TopoDraphy, final grading plan, and other pertinent drainage information. (If plan has too much
information, show drainage on separate sheet.)
^ 8. All existing streets, drives, .buildings, and water .courses on or adjacent to the proposed project site.
~9. Locate 100 yr. floodplain on or adjacent to the proposed. project site, note if there is none on the site.
^ 10. Location and size of existing utilities within or adjacent to the proposed project site.
^ 11. Proposed location, type, and size of the following:
a.) Buildings and structures
b:) Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned
c.) Sidewalks
d:) Common open space sites
e:) Sites for solid waste containers
^ I2. Proposed streets, .drives, and curb cuts. For each proposed curb cut .(including driveways, streets,
.alleys, etc.) locate existing curb cuts on the same and opposite side of the street to determine separation
distances between existing and proposed curb cuts. Indicate driveway throat length as measured in the
Driveway Ordinance. (See Ordinance 1961 for driveway location and design requirements.)
^ 13. The total number of residential buildings and units to be constructed on the proposed project site.
^ 14. Landscape plan as required in Section 11 of the Zoning Ordinance (See Ordinance # 1638.) The
landscaping plan. can be shown on a separate sheet if too much information is on the original site plan.
Attempt to reduce or eliminate plantings in easements. Include information on the plan such as:
a) existing landscaping to remain
b) required point calculations
c) proposed new plantings with points earned
^ 15: Indicate unit type (number of bedrooms).
^ 16. The density of dwelling units per acre of the proposed project.
^ 17. The gross square footage of buildings and the proposed use of each building.
^ 18. Designate number of parking spaces required by ordinance and provided by proposal.
^ 19. Show dimensions to size and locate all structures, parking spaces, drives, curb cuts, parking islands, and
setbacks.
^ 20. Are there impact fees associated with this development?
^ 21. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average
demands in gallons per minute) and sewer loadings (maximum demands in gallons per day).
^ 22. Show all meter locations and note their sizes.
The following are typical standards for Plan Development established by Ordinance or Polucy:
^ L Building separation is`a minimum of I5 feet.
^ 2. Building setbacks are outlined in Ordinance 163.8, Zoning Ordinance, Table A (Sec. 7, P. 30).
^ 3. Minimumparking space is 9' ~ 20', or on a perimeter row, 9' x 18' with a 2' overhang.
^ 4: Minimum drive width is 23' with head-in parking or 20' without parking.
^ 5. Raised landscaped islands, (6" raised curb) of a minimum of 180 sq. ft. are located at both ends of every
parking row. Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be
provided.
^ 6. Streetscape compliance is required which involves special plantings along streets specified in the City's
Streetscape Plan.
^ 7. A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To
include islands, planting .areas, access ways, dumpster locations, utility pads, etc.) Curb detail to be
approved b~Cit~Enaineer: No exceptions will be made for areas designated as "reserved for future
parking".
^ 8. Wheelstops may be required on interior rows longer than 10 spaces or in special situations.
^ 9. Sidewalks are required at time of development if property has frontage on a street shown on the
sidewalk Master Plan or if the Project Review Committee determines the necessity. (Refer to Section
10.2 of the Zoning Ordinance):
^ 10. Locations of dumpsters shall be such that dumpsters are not visible from streets. Gates are discouraged
and visual screening is required.
^ 11. Healthy, native trees over 6" in caliper should be retained whenever possible.
^ 12. Fire lanes of a minimum of 20 feet in width with a minimum height clearance of 14 feet must be
established if any structure of any type is more than 150 feet from a public street or highway.
^ 13. Any structure in .any zoning district other than R-1, R-lA, or R-2 must be within 300 feet of a fire
hydrant as measured along a public street or highway.
^ 14. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location
approved by the City Engineer.
^ 15. Fire hydrants trust be operable and accepted by the City and drives must have an all weather surface
before a building permit can be issued:
^ 16. A twenty four foot setback from R.O.W. to curb of parking lot is required. Parking may be allowed in
this area up to a maximum of 7 contiguous spaces.
^ 17. All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water
systems for buildings and must be sized accordingly and include backflow prevention protection.