Loading...
HomeMy WebLinkAboutMiscellaneousSUBMIT APPLICATION AND THIS LIST CHECKED-0FF WITH 16 FOLDED COPIES OF SITE PLAN FOR REVIEW REQUIREMENTS FOR SITE PLAN PROPOSALS _'~`~ C~ 1. Sheet size - 24" x 36" ~ ~ 2. Title block to include: a.) Name, address, location, and legal description b.) Name, address, and telephone number of applicant c.) Name, address, and telephone number of developer/owner d.) Name, address, and telephone number of architect/engineer e.) Date of submittal l~ ~ 3. Ownership and current zoning of parcel and all abutting parcels. % ^ 4. A key map (not necessarily to scale). C~ 5. Scale should be largest standard engineering scale possible on sheet. C7~6. Provide a north arrow. ''~'~ C~ 7. Topography, final grading plan, and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) All existing streets, drives, buildings, and water courses on or adjacent to the proposed project site. CC~9. Locate 100 yr floodplain on or adjacent to the proposed project site, note if there is none on the site. l~,/10. Location and size of existing utilities within or adjacent to the proposed project site. C~' 11. Proposed location, type, and size of the following: ~~ a.) Buildings and structures b.) Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned c.) Sidewalks d.) Common open space sites e.) Sites for solid waste containers C~ 12. Proposed streets, drives, and curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts on the same and opposite side of the street to determine separation distances between existing and proposed curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance 1961 for driveway location and design requirements.) ~C~ ^ 13. The total number of residential buildings and units to be constructed on the proposed project site. ~4. Landscape plan as required in Section 11 of the Zoning Ordinance (See Ordinance # 1638.) The landscaping plan can be shown on a separate sheet if too much information is on the original site plan. Attempt to reduce or eliminate plantings in easements. Include information on the plan such as: a) existing landscaping to remain b) required point calculations c) proposed new plantings with points earned /(s. ^ 15. Indicate unit type (number of bedrooms). ^ eY6. The density of dwelling units per acre of the proposed project. Q' 17. The gross square footage of buildings and the proposed use of each building. " [118. The total site area and percent of building coverage of site. ;' [~' 19. Designate number of parking spaces required by ordinance and provided by proposal. t~20. Show dimensions to size and locate all structures, parking spaces, drives, curb cuts, parking islands, and setbacks. lCop. ^ 21. Are there impact fees associated with this development? The following are typical standards for Plan Development established by Ordinance or Policy: 1. Building separation is a minimum of 15 feet. ' ~2. Building setbacks are outlined in Ordinance 1638, Zoning Ordinance, Table A (Sec. 7, P. 30) C~ 3. Minimum parking space is 9' X 20', or on a perimeter row, 9' x 18' with a 2' overhang. All multi-family parking lots must be screened from rights-of way. ~'/ C~4. Minimum drive width is 23' with head-in parking or 20' without parking. ~~'~ C~ 5. Landscaped islands of 6" raised curb are located at both ends of each parking row. 1' C~6. Landscaped islands are also located every 15 spaces or interior rows and every 20 spaces on perimeter rows. Str~etscape compliance is required which involves special plantings along certain specified in the City's Streetscape Plan. C~ 7. A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include islands, planting areas, access ways, dumpster locations, utility pads, etc.) Curb detail to be approved by Cit~Engineer. No exceptions will be made for areas designated as "reserved for future parking". ~8. Wheelstops maybe required on interior rows longer than 10 spaces or in special situations. O' 9. Sidewalks are required at time of development if property has frontage on a street shown on the sidewalk Master Plan or if the Project Review Committee determines the necessity. (Refer to Section 10.2 of the Zoning Ordinance). Cd°10. Director of Public Services determines number, and size of dumpsters. Locations shall be such that dumpsters are. not visible from streets. Gates are discouraged and visual screening may be required. Gd' 11. Parking islands are 9' X 20 ; or 180 square feet. C~' 12. Healthy, native trees over 6" in caliper should be retained whenever possible. hrl p. ^ 13. Fire lanes of a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any structure of any type is more than 150 feet from a public street or highway. ;" ~jp ^ 14. Any structure in any zoning district other than R-1, R-1A, or R-2 must be within 300 feet of a fire hydrant as measured along a public street or highway. '-~`~ ~~ (~ 15. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the Fire Marshal's office and the Superintendent of Water and Sewer. C~ 16. Fire hydrants must be operable and accepted by the City and drives must have an all weather surface -/ before a building permit can be issued. !~ 17. A raised island not less than 6" in height and not less than 8' in width shall separate parking areas from public rights-of--way. Eight foot setback from R.O.W. to curb of parking lot. Interoffice Memo To: Veronica Morgan From: Tim Dedear Date: January 26, 1995 Subject: PRC for Feb 1, 1995 Care Plus Optometrist Office -- Fire lanes shall be installed if any part of the structure is more than one hundred fifty feet from a public street ,alleyway, or highway provided, however, that such structure maybe erected at a greater distance if the owner or developer designates, constructs and maintains a fire lane having a minimum width of 20' and minimum height clearance of fourteen feet (14'), terminating within 150' of the furthermost point of such structures. Southwood Valley Turf -- Install a 2A-lOBC minimum 5 lb. fire extinguisher in the proposed building. 603.1.3 B -- Public fire hydrants shall be installed in districts other than single- family and duplex districts at such locations that no part of any structure shall be more than 300' from a fire hydrant as measured along the right of way of a public street or along an approved fire lane as the fire hose is laid off the fire truck. Edelweiss Estates Phase Five -- No comments La Cour Subdivision -- No Comments 01i27i95 13:56 GTE ENGINEERING ERYAN 002 :~-~umum.~~IIIRIDII~~--'. I',~ld.l;!"~i.: L:'l' f=1-,:~~ ~ c,:,tttt I?l.,lf:; c~N'I'i~aiE;'I'K1.:;~ :t!•!•''h; i'y°:--1l1:;; N;/'.::1~ '1'r.J Lsf:;c'l;ti: Hite 'j'1i7:5 L'1L''VI::Lt1E'~1~.^:';' !:'I.LL ;iE~ ~E:1:'%t';.1 is j~i~j..i 't't•;L7::1'fitlhiE vLtt~' i(,1:. wtLL i'l' 131; SFJtt'Lll 'I`HftUU{:H Tl11; i:I'1..ltl:;;~';' i_.1}tF: I'L~~.; :;t: ~'1''i:ll t)}t. tdILL I'1' S'1'.~t~!) C~1ti' :i'L';: ri!r•^:. :.'j' _~:`~C:.^~:t: j° }:~; ~h:tt~'E;1) `1~HhcCit~~f1-I ~!'HF: {ifl:~li ~5 tT ZS C:tIKHI~:~f'1'L~" f:l:l.,"+'Ci SEi-~VI-:I}. ! I'' 1'I` I5 '7.'U L.r~ ~,i•:f2.\~I:U 'i'HK(?Ut;H 'I'FJ1J f:_ti7:. }'t,~:, t'~~ILk: ''t~''.• - €`}1 .'. 1,f;':;~~~LOE'{~1t1!_::~~~~F:It L~ Jth:tif-'U>ti~lESs,r' r'Ux c:it~:i1U1,1, AN11 c:,aC~t~ta 1'Lr;t.;h:`17;I~T ':~:,•~ C: ,yI4'.:, 1•'>Jt!•`_: 7'(1 Z`}i~ P: F:tC' !?1';`•'7•;i.~tY^; !'. 'l'. 1,'' 1';~ ;.. '!''. a'1'/l l~~ fi Ca*: ! `1':~ c.rt; ^: ,'r~f F; ll1-:V h:I.UY~:K t+- j LL Hr1 ~ I, '1''c? 1.-'t.A(; t-: 1': tf }~!-~t.' ." ! f, i i'U~~ I,t, 7.'1'' ;•'+)!t is f't. 7':i YL.•1t_-!~: t: Al;..r:. YL1;~1::t•; t_ .; ~i'I' ~s.: l` ~ ~}:. :'~ I' 'f t7~air~;:l-=s`ru;i ;';~ i,[:~C:t:S:a t;t~Nl~l,.l'1' YL.~f,f;Ml~:~'1' :tti1~ J~IHI•.ti. (~~' I' k; Printed by Shirley Volk 2/08/95 2:09pm From: Jane Kee To: Veronica Morgan Subject: fwd: Care Plus project ---------------------------------------------------------------------------- ===NOTE====------=====2/08/95==9:07am=====__°_______________________________ CC: Shirley Volk Robert w/WSA called. Owner wants to service new bldg. separately (elec. water and sewer). Robert has already talked to GTE and elec. Our utility folks told him there is an 8" waterline along the back. They said to call us re: whether he can tie into this. - it will have to cross a drainage ditch apparently. There is a sewer line along Texas that they want to tie into. Also asked about the handicap ramps - adjacent property line to east runs right along the curb of the care plus drive. Robert wants to talk about how to do a ramp here and whether this owner really should be the one doing it or the adjacent owner. Can you give him a call and talk about this things please. His # is 779-2398. Thanks. If you can do it today that would be great. Fwd=by:=Veronica=Morg=2/08/95==1:57pm===____________________________________ Fwd to: Jane Kee, Shirley Volk ............................................................................ passed on to paul with wsa.... he called me about some ddp questions so i passed info on to him.. 1. no problem tying onto waterline in rear 2. no problem tying onto sewer in front 3. we will require only 1 ramp on the west side. we'll get the other with boedeker site plan. Paae: 1