Loading...
HomeMy WebLinkAboutMiscellaneous~~~~~ I~¶¶~~~T[~~~>~~~~7{ ~¶¶~~~dy~~~~~ ~QDIIIlSIlIlll~IlR1~ ~IlIl~IlIIIl~~II°S ® ll.e~.IlIlQll ~IlIlII°d~g'®Il°S 4103 Texas Avenue, Suite 212 Bryan, Texas 77802 Telephone 409/840-6212 Fix 409/846.8252 B J. Kling, P.E., R.P.L.S. S.Nf. Kling, R.P.L.S. December 15, 1994 Memo Post Office Box 4234 Bryan, Texas 77805 To: Shirley Volk, City of College Station ~ ~ `°~~ From :Danny Miller, Kling Engineering & Surveying 4~,~ f~~ ~,.,- ... ~ ~o.. . ~'~ RE: Waterline oversize participation for Greensworld, Phase Two ~^ ~ ~r ~~ ' f ~~~ j ,~~ ~~ ,,~''~ , The owner/developer of this project would like. to request that the city participate in the oversizing of a water line extension across his project. The proposed development is to be a new car dealership and only requires an 8" water line for fire protection and domestic use. The city currently has an 18" water line ending south of the subject site that will be extended .across the project. Obviously, this 18" Fine is not needed for the proposed project and therefore the owner request participation from the city for the difference between an 8" water line to an 18" water line. BIKES 94-026\grnwld.memo Printed by Nanette Manhart 1/11/95 12:53pm ---------------------------------------- From: Jane Kee To: Nanette Manhart Subject: Greensworld PP TWO ---------------------------------------- ====NOTE______________= 1/11/95 11:43am= Please get a cagy of ORD. # 1831fI hope you have it in your book} I don't know if it°s a rezoning ord. or annexation ar what BUT give it to Fred ASAP to compare it with the Greensworld TWO PP. Mike Davis thinks TWO is zoned G-2 and I think it might be zoned R-1. What do you think? I need to have the staff report ready tomorrow AM ~~.~ - , ~ ~ n„p, ~`~ Engineer's Estimate ~`® 18" Water Line Greensworld, Phase Two College Station, Brazos County, Texas January 11, 1995 v i 18" MJ DIP Water Line 18" - 22 %s " Bend Fire Hydrant w/Appurt. incl. 18" x 6'° tee 2" -Air & Vacuum Valvle 18" x 8" tee 4" Blow off if existing connot be salvaged Trench safety ~ Unit Price Total 684 LF 540 $27,360 1 ea. 51250 5 1,250 1 ea. 53000 5 3,000 1 ea. 52000 5 2,000 1 ea. 51500 5 1, 500 1 ea. 52500 5 2,500 690 LF 52 S 1,380 TOTAL: 538,990 10% CONTINGENCY : S 3,~QQ 542,890 8" MJ DIP Water Line 684 LF 515 510,260 8" - 22 %Z ° Bend 1 ea. 5200 5 200 Fire Hydrant w/Appurt. 1 ea. 51750. 5 1,750 2" -Air & Vacuum Valve 1 ea. 51750 5 1,750 8" x 8" Tee 1 ea. 5250 5 250 4" Blow off valve 1 ea. 52500 5 2,500 Trench safety 690 LF 52 S 1,380 TOTAL: 518,090 10% CONTINGENCY: S 1,800 519,890 DIFFERENCE: 523,000 .~ :. ~r 4 ~,LV ~Y ~! yy.A~ ~~ ~ 50Cy4 krr {~5 ~ 1*~ /7 OC~b ,yW~ 9M~ L..n L] ~ t s~~~~ `~ S~ Kling Engineering & Surveying