Loading...
HomeMy WebLinkAboutMinutes PROJECf ..REVlEWCOMMITlEEREPORT May 7, 1993 TO: ScottA. McFarland, Adams Consulting Engineers, Inc. 6320. Copeland Road, Tyler ,TX75 703 FROM: Project Review. Committe : Jane l(ee,CityPlanne' David Pullen, CityEng.e r MikeLane,P&ZRere entative Others Attending: Natalie Thomas, PlanniI1g.Technician Samantha Smith, Engineering Assistant Tony. Michalsky, ..Electrical.Operations . Coordinator ShirleyVolk,Development Coordinator Veronica Morgan~Assistantto the City Engineer PeteVanacek, . Parks Senior Planner Sabine Kuenzel, Staff Planner Gali Dolev,Planninglntern Laverne Akin, . GTE Representative Mike Lavender,TCA Cable Representative SUBJECf: PARKING LOTPLAN- Wal Mart Expansion; proposed expansion of the existing WalMartStore #1150 located at lS15 Brothers Boulevard.. (93- 410) The Project Review Committee met on Wednesday, May 5, 1993 to discuss the above mentioned parking lot plan. The following comments were made by the various reviewing .agents: PLANNING: Submit . a landscaping plan in compliance with the current Zoning Ordinance. Coordinate point requirements with Mapping Specialist Nanette Manhart at (409) 764-3570. Submit screening details, size. and type of trash compactor. to be relocated near Brothers . Boulevard. . The compactor must be screened .from all rights-of-way. Add a screening wall on the two sides of the compactor to match the building. Coordinate. size and type of trash compactor with Sanitation Superintendent Jim Smith at (409)764-3690. The parl(ing lot should be setbackS' from the property line. Show the setback line on. the site plan. PRCReport Wal Mart Exp Case #93-410 Page 2 ENGINEERING: Assurethatthe.proposed water line to be located off of this property is .covered with public utility easements .. and show the proposed line on. the. site plan. Coordinate requirements with City Engineer David Pullen at (409) 764-357()' There appears to be a storm sewer in the 40' drainagean<l utility easement which simply stops. . Where does. the. storm sewer actually .end? .Supply infor:ma tion regarding distances between utilities before a determination can be made regarding..the proposal to replace a 40' easement. with a 28' easement. A drainage. development permit is required prior to any site work. Coordinate details with Assistant'to the City Engineer Veronica Morgan at (409) 764-3570. ELECfRlCAL: Show existing and proposed utilities including. any proposed relocations. The developer is responsible for providing public utility easements to cover all lltilities and for paying. thecostsassociated...withtherelocation. . Coordinate electrical service and relocation with'Electrical Operations Coordinator Tony Michalsky at (409) 764-3660. Provide two 4" condui tsfor .. electrical service ~ G.T.E.: Show.. existing .<and .proposedutilities including any proposed reloeations. Telephone service lines will follow electrical lines and may need to be extended to Brothers ..Boulevard. The developer . is responsible for paying the costs associated with the relocation. Coordinate service details with G.T.E. Representative Laverne Akin at (409) 821-4723. Show proposed demarche point. Provide two 3" conduits for telephone service lines. BUILDING: Coordinate second .electrical service to the existing building with Building ()fficial Coy Perry at (409) 764.3741. FIRE: Relocate.theexisting fire hydrant on the south side of the building ]located between the two proposed access drives off of Brothers Boulevard to tIle east side of the most easterly . drive off. ofBrothersB.oulevard. .. . Add afire hydrant on the west side of the most westerly drive off of Brothers Boulevard approximately 145' off of Brothers Boulevard. (See the attached drawing showing the proposed fire hydrant location. ) Coordinate details with Fire Inspector George SIJain at ( 409 )764-3781. Submit fire sprinkler plans and calculations with the building plans. PRC Report Wal Mart Exp Case #93-41.0 Page 3 WATER/WASTE · WATER: Shbwthesamesanitaty. sewerlirteCbnfigutation\onthe "ExistingUtility Plan" sheet as shown on the "ProposedUtilityPlan"~ Show how water service will be continued during . the relo.cation of the existing water. Jine. Submit. construction documents for relocation of the existing water line alld any sanitary sewer lines. Show the existing water and sanitary sewer mains on the . landscaping plan. Water and sanitary sewer lines should be approximately 10' away from trees and 5' away from shrubs. SUBMIT.....4 COMPLETE..SETS OF. CONSTRUCTION.. DOCUMENTS WITH: THE REVISED SITE> PLAN> ATTACHEDAND.3ADDITIONALSITEPLAN"S TO CONTINUE < WITH ..PHASE. II. OF THE BUILDING PERMIT PROCESS.SlJBMIT 1QCOPIESOFGRADING PLANS FOR REVIEW AND APPROVAL PRIOR TO ISSUANCE OF A DEVELOPMENT. PERMIT TO ALLOW < ANY SITE. WORK.