Loading...
HomeMy WebLinkAboutMiscellaneous Printed by Joey Dunn 3/28/95 1: 54pm." ~____.______~~~_~~__~~~__~,__~~~_-~~_~~~_f_ From: Jane Kee To: Joey Dunn Subject: Pebcrk Maintenance Bldg. - - - - - -- - --...- ~....... ~ -.... -.... ......._....~--- -----~ -~ -... ...-'-- ---NOTE' -_......-. '-.' --., '--. --'. -......--3../.2.8./.9....5... .-......-... .1.....5. ..2'..p'. ....m.... ..-........... --- ......" ----~----------~----.". ..... ....-... ......- -.':' ...... '._~ 1'11 place '~l.blue file on your desk (92-425). Sometime over then.ext couple of weeks please gcoutto this site and take photos an.dcomparewhat you see to what the site planshows.and the PRC'report says. I went by here yesterday and it isa mess. I want to document the situation before I call anyone. I thought this might be... a chnage of pace from ZBA'and oil wells and Northgate.lfyou want to.talk -about it before you.gojustholler. Thanks. ----------~~---,._--~~~~-~~,~~-~~---~~.~-~- Page: .1 ;J . ,.~..- PROJECf ,REVIEW COMMITTEE REPORT. December 1, 1992 TO: Dan Sears and A.P.Boyd, Pebble Creek Development 4500 Pebble Creek Parkway, College Station, TX 77845 David Mayo, Joe ,Orr, Inc. 2167 Post Oak Circle, College Station, TX 77840 FROM: Project Review C,?mmittee: /'~- <~p Jane Kee, SenIor Plannel='_~'"/''''''' V. e, ronl".C,R Morg..anl As...... sista t ..0 the City Engineer Mary Elizabeth Herring,t 'ZCommissioner Others Attending: Natalie. Thomas, Planning Technician Samantha Smith, Engineering Assistant Deborah ~eating, Project Engineer Shirley Yolk, Develqpment Coordinator Bland Ellen, Fire Marshal SUBJECf: PARKING LOT PLAN - Pebble Creek Maintenan.ce Building (92-425) The Project Review Committee met on<Wednesday, November 25, 1992 to discuss the above mentioned parking Jot plan. The following comments were made by the various reviewing agents: PLANNING: There was. consensus among the Project Review Committee that..because. this site is part of the golf course, . the 'landscape ordinance does not apply. Staff suggested thatplantiIlgs be installed along Greens Prairie Road to screen the building. There w.asconse.nsus. that because ..' this parking. lot is. " not meant for public parking, it need not have curb or pavement except where the designated spaces are. The remainder may be gravel where storage and maintenance occurs. There was consensus that the sidewalk ordinance does not apply as well because it is not necessary to this site. Locate the existing trees with caliper size on the site plan. The proposed dumpster must . be screened from the Greens Prairie Road. Submit a letter. referencing the status i of the final plat of this area prior to issuance of a building permit. . --:.... PRC Report PC MaintBldg Case #92-425 Page 2 ENGINEERING: Show floodplain line and any floodway .on this site plan. A dr~inage development permit is. required prior to any site work. Coordinate requirements with Project Engineer Deborah Keating at (409) 764-3570. Submit. erosion control plan to include a note stating that the contractor is responsible to seed or sod all disturbed areas. Dimension the radius of the drive, the depth of the drive to the gate and inside radius. Delineate the curb and gutter lines. Distinguish between pavement materials such as asphalt, gravel, curb and gutter, etc. FIRE: The fire hydrant should be located within 5' of the curb. Fire lanes are required for this site. Coordinate ordinance requirements with Fire Marshal Bland Ellen at (409) 764-3705. Coordinate the fire department accessibility through the proposed gates with Fire Marshal Bland Ellen. WATER/WASTE WATER: Label the fire hydrant "shown as existing. Submit construction documents .and ,.all necessary easements for the proposed extension of the, sanitary sewer line to serve this building. Provide a more specific location map. ELECfRlCAL: Coordinate service details with Electrical Operations Coordinator Tony Michalsky at (409) 764-3660. LONE STAR GAS: Coordinate service details with Lone Star Gas Representative Don Fazzino at (409) 776-0627. SUBMIT 4 COPIES. OF COMPLETE CONSTRUCTION DOCUMENTS WITH THE REVISED SITE PLAN ATTACHED AND 3 ADDITIONAL COPIES OF THE REVISED SITE · PLAN ONLY TO CONTINUE WITH PHASE II OF THE BUILDING PERMIT PROCESS. ,,~ Y"" DRENNON ASSOCIATES CONSULTING.' ENGINEERS JOHN R. ROGERS, JR., P.E. President GLENN L. DRENNON, P.E. Consultant December 14,1992 Project Name and Location: PebbleCreekC.C. Maintenance Building Greens Prairie Rd@ Lick Creek 4500 Pebble Creek'Blvde College Station., Texas owner/Contractor Name and Address: Pebble CreekOevelopment corporation 4500 Pebble Creek Blvde college station, Texas Project Engineer: Drennon Associates John R. Rogers, Jr., P.E. 4800 Lakewood, Suite 7 Waco, Texas 76710 STORM WATER POLLUTION PREVENTION PLAN a. Nature of construction activity: 1. site description: The project is the construction of a maintenance building for Pebble Cre'ek c.c. to house and maintain golf course maintenance equipment, including but not 1 imi ted to greens mowers,. tractors 1 fairway mowers f 'ete. The 97 ,635 sq. ft site will be regraded to provide a building pad for the building, paved access around building for fire protection and access by equipment and some gravel areas for temporary parki.ng of equipment. Most of the 81 te, (65%) will be disturbed during construction and all non-paved or graveled areas will be replanted with lawn at completion of construction. 817-772-4201 page 1 P.o. BOX 20037 WACO, TEXAS 76702-0037 A/'- '/ _I. ,I. , F~X 817-772-4203 /~ I ~ :Z-~/~'-~ , b. Seauence of, MaiorActivities: Theproj ect will take approxi.mately 3 months for construction of all site improvements. The site is slightly domed and very little change to eXisting drainage will be required. The building consist of precast concrete wall and roof panel construction on a drilled pier foundation. Parking lot, entry drive and pad around bUilding will be asphalt paving. A concrete padforthedumpsteI~ and an, above ground fuel storage tank will be provided. A containment wall around the fuel tank equal to the volume of the tank plUS 25% will be provided along w1thvalving to remove storm water. c. Estimated Total site Area, total disturbed area: Total area approx.97,635sq.ft. (2.24 acres) Total disturbed area, 64,000 sq.ft. (1.46 acres) All major trees will be.protectedandwill remain. d. Runoff,. Coefficient: At completion of construction c = .34 paved gravel lawn 25/98 * .9= .23 5/98 * .7 =.036 68/98 * ~ = .069 c = .335 e. Site And vicinitv mans: Site and vicinity maps are enclosed. f. Receivinawater: All surface water drains into Lick Creek: 2. Controls: a. Existing trees will be protected during construction. b. straw bales or filter 'fabric. fences will be placed to prevent silt from .draininginto the creek on either side' of the ..si te. page 2 " 3. General: a . The present site is has i.t's h1ghpoint at the locat1onofthe.proposedbuild1ng and the finish drainagew111 not measurably change the current site drainage. b. The building is outside. the floodwaybut in the floodplain and will inotcreate a significant change in the drainage patterns. Sincerely, JRR:bb ....--~'b)"}~~ ;.,. ~f..\.,.. .~~. ..........~...... ..ft.......... ..... ...v.. fA I.... .' .... .'.*" it *. '. '. .'. , * ~ .:if' '. . . .' ... .... , ~ 2.' ..... .. ....un. n. , '. , ,~ ~"6~R~'.'tB.,!'~1 '~~".... 31549... ':~I ..,~,<. '. . '.' · ,'4Y1iJJ '.. ~;....~tGIaTE"\\.~.x.~ ",'5'/0. .. · .. ~~~ \\,.-<<,\"-,,,,-- page 3