From: Jane Kee
To: Joey Dunn
Subject: Pebcrk Maintenance Bldg.
- - - - - -- - --...- ~....... ~ -.... -.... ......._....~--- -----~ -~ -... ...-'--
---NOTE' -_......-. '-.' --., '--. --'. -......--3../.2.8./.9....5... .-......-... .1.....5. ..2'..p'. ....m.... ..-...........
--- ......" ----~----------~----.". ..... ....-... ......- -.':' ...... '._~
1'11 place '~l.blue file on your desk
(92-425). Sometime over then.ext
couple of weeks please gcoutto this
site and take photos an.dcomparewhat
you see to what the site planshows.and
the PRC'report says. I went by here
yesterday and it isa mess. I want to
document the situation before I call
anyone. I thought this might be... a
chnage of pace from ZBA'and oil wells
and Northgate.lfyou want to.talk
-about it before you.gojustholler.
Thanks.
----------~~---,._--~~~~-~~,~~-~~---~~.~-~-
Page: .1
;J . ,.~..-
PROJECf ,REVIEW COMMITTEE REPORT.
December 1, 1992
TO:
Dan Sears and A.P.Boyd, Pebble Creek Development
4500 Pebble Creek Parkway, College Station, TX 77845
David Mayo, Joe ,Orr, Inc.
2167 Post Oak Circle, College Station, TX 77840
FROM: Project Review C,?mmittee: /'~- <~p
Jane Kee, SenIor Plannel='_~'"/'''''''
V. e, ronl".C,R Morg..anl As...... sista t ..0 the City Engineer
Mary Elizabeth Herring,t 'ZCommissioner
Others Attending:
Natalie. Thomas, Planning Technician
Samantha Smith, Engineering Assistant
Deborah ~eating, Project Engineer
Shirley Yolk, Develqpment Coordinator
Bland Ellen, Fire Marshal
SUBJECf: PARKING LOT PLAN - Pebble Creek Maintenan.ce Building (92-425)
The Project Review Committee met on<Wednesday, November 25, 1992 to discuss the
above mentioned parking Jot plan. The following comments were made by the various
reviewing agents:
PLANNING:
There was. consensus among the Project Review Committee that..because. this site
is part of the golf course, . the 'landscape ordinance does not apply. Staff
suggested thatplantiIlgs be installed along Greens Prairie Road to screen the
building.
There w.asconse.nsus. that because ..' this parking. lot is. " not meant for public
parking, it need not have curb or pavement except where the designated spaces
are. The remainder may be gravel where storage and maintenance occurs.
There was consensus that the sidewalk ordinance does not apply as well because
it is not necessary to this site.
Locate the existing trees with caliper size on the site plan.
The proposed dumpster must . be screened from the Greens Prairie Road.
Submit a letter. referencing the status i of the final plat of this area prior to
issuance of a building permit.
. --:....
PRC Report
PC MaintBldg
Case #92-425
Page 2
ENGINEERING:
Show floodplain line and any floodway .on this site plan.
A dr~inage development permit is. required prior to any site work. Coordinate
requirements with Project Engineer Deborah Keating at (409) 764-3570.
Submit. erosion control plan to include a note stating that the contractor is
responsible to seed or sod all disturbed areas.
Dimension the radius of the drive, the depth of the drive to the gate and inside
radius.
Delineate the curb and gutter lines.
Distinguish between pavement materials such as asphalt, gravel, curb and gutter,
etc.
FIRE:
The fire hydrant should be located within 5' of the curb.
Fire lanes are required for this site. Coordinate ordinance requirements with Fire
Marshal Bland Ellen at (409) 764-3705.
Coordinate the fire department accessibility through the proposed gates with Fire
Marshal Bland Ellen.
WATER/WASTE WATER:
Label the fire hydrant "shown as existing.
Submit construction documents .and ,.all necessary easements for the proposed
extension of the, sanitary sewer line to serve this building.
Provide a more specific location map.
ELECfRlCAL:
Coordinate service details with Electrical Operations Coordinator Tony Michalsky
at (409) 764-3660.
LONE STAR GAS:
Coordinate service details with Lone Star Gas Representative Don Fazzino at
(409) 776-0627.
SUBMIT 4 COPIES. OF COMPLETE CONSTRUCTION DOCUMENTS WITH THE
REVISED SITE PLAN ATTACHED AND 3 ADDITIONAL COPIES OF THE
REVISED SITE · PLAN ONLY TO CONTINUE WITH PHASE II OF THE
BUILDING PERMIT PROCESS.
,,~
Y""
DRENNON ASSOCIATES
CONSULTING.' ENGINEERS
JOHN R. ROGERS, JR., P.E.
President
GLENN L. DRENNON, P.E.
Consultant
December 14,1992
Project Name and Location:
PebbleCreekC.C. Maintenance Building
Greens Prairie Rd@ Lick Creek
4500 Pebble Creek'Blvde
College Station., Texas
owner/Contractor Name and Address:
Pebble CreekOevelopment corporation
4500 Pebble Creek Blvde
college station, Texas
Project Engineer:
Drennon Associates
John R. Rogers, Jr., P.E.
4800 Lakewood, Suite 7
Waco, Texas 76710
STORM WATER POLLUTION PREVENTION PLAN
a. Nature of construction activity:
1. site description:
The project is the construction of a maintenance
building for Pebble Cre'ek c.c. to house and maintain
golf course maintenance equipment, including but not
1 imi ted to greens mowers,. tractors 1 fairway mowers f
'ete. The 97 ,635 sq. ft site will be regraded to
provide a building pad for the building, paved access
around building for fire protection and access by
equipment and some gravel areas for temporary parki.ng
of equipment. Most of the 81 te, (65%) will be
disturbed during construction and all non-paved or
graveled areas will be replanted with lawn at
completion of construction.
817-772-4201
page 1
P.o. BOX 20037 WACO, TEXAS 76702-0037
A/'- '/ _I. ,I. , F~X 817-772-4203
/~ I ~ :Z-~/~'-~
,
b. Seauence of, MaiorActivities:
Theproj ect will take approxi.mately 3 months for
construction of all site improvements.
The site is slightly domed and very little change to
eXisting drainage will be required.
The building consist of precast concrete wall and
roof panel construction on a drilled pier foundation.
Parking lot, entry drive and pad around bUilding will
be asphalt paving. A concrete padforthedumpsteI~
and an, above ground fuel storage tank will be
provided. A containment wall around the fuel tank
equal to the volume of the tank plUS 25% will be
provided along w1thvalving to remove storm water.
c. Estimated Total site Area, total disturbed area:
Total area approx.97,635sq.ft. (2.24 acres)
Total disturbed area, 64,000 sq.ft. (1.46 acres)
All major trees will be.protectedandwill remain.
d. Runoff,. Coefficient:
At completion of construction c = .34
paved
gravel
lawn
25/98 * .9= .23
5/98 * .7 =.036
68/98 * ~ = .069
c = .335
e. Site And vicinitv mans:
Site and vicinity maps are enclosed.
f. Receivinawater:
All surface water drains into Lick Creek:
2. Controls:
a. Existing trees will be protected during construction.
b. straw bales or filter 'fabric. fences will be placed to
prevent silt from .draininginto the creek on either
side' of the ..si te.
page 2
"
3. General:
a . The present site is has i.t's h1ghpoint at the
locat1onofthe.proposedbuild1ng and the finish
drainagew111 not measurably change the current site
drainage.
b. The building is outside. the floodwaybut in the
floodplain and will inotcreate a significant change
in the drainage patterns.
Sincerely,
JRR:bb
....--~'b)"}~~
;.,. ~f..\.,.. .~~.
..........~...... ..ft.......... ..... ...v.. fA
I.... .' .... .'.*"
it *. '. '. .'. , * ~
.:if' '. . . .' ... .... , ~
2.' ..... .. ....un. n. , '. , ,~
~"6~R~'.'tB.,!'~1
'~~".... 31549... ':~I
..,~,<. '. . '.' · ,'4Y1iJJ
'.. ~;....~tGIaTE"\\.~.x.~
",'5'/0. .. · .. ~~~
\\,.-<<,\"-,,,,--
page 3