Loading...
HomeMy WebLinkAboutMisc. "ii Z; BUITap Construction Company, Inc. 764-9053 - December 19, 1988 Mrs. Jane Key Engineering & Planning City of College Station College St a't i on ,Texas RE: CC Creation.s College Station, '.'Texas Dear Mrs. Key: This letter is to confirm our conversat.ion concerning installation of required landscaping for CC Creations, 112 Holleman Drive, College Station, Tex.as. Enclosed YOlI will find. a copy of thee'xecuted con- tract for landscaping to beins.talledat the above location. This will be c.ompletedwi th thirty (30) days. Thank you for your help in tIlis matter. Sincer'ely, BJU~i Bill Taparauskas BT/lt 1501 F .M. 2818, Suite 112 P.O. Box 9559 CollegeStation,Tx. 77840 .Ill> . Landscape ,Estimate' prepared by' . }O BARRETT. & ASSOCIATES 2';'02 Allen Forest Br3,au, Texas 77803 (409) 776-2621 ....-? ~ ~>,~fl. '.' [" ''''..V..VI..! . ~ 1\. '/...l . r}Y/f.' \ ,j! /L (// /I L' '0 'T - . /;~ ' t ~ I QTY. }rrEM 7 5 10 18 17 13 120 LS LS Live Oak Trees Bradford Pear '.rrrees Crepe Myrtle Trees Sea"9reenJuniper Texas Sage Yucca Flacida . Metal', Edging PlarltingAdmendraents Topsoil 'c: .\ '~1 tJuA. .. .. ....B '. ({Y\ <j J ~.1 SIZE. UN.PRICE 24"Box 15 Gal 15 '.Gal 5 Gal 5 Gal 5 Gal $200.00 $>75.00 $ "75.00 $ 12.00 $ 14.00 $ 12.00 $'. 2..00 PRICE $1400.00 $ 375.00 $ 750.00 $ 216.00 $ 238.00 $ 156.00 . $ 240.00 $ 300.00 $ 100.00 3 Days @ $250..00/Day $ 750.0'0 . 1150.'00 $4675.00 1351.00 $5026.00 CIC.Creations % BIIITapConstructior College Station, Texas Proposal accepted and ~pproved by: 13~.~~~ 17~.fS'vg8 BIll.. Tap-.ontractor' Date TOII1Barreft at Barrett & Associates - Owner 'i.~"-CITYOI:: COLLEGE STATION ".i. . ... d. ... PLANNING DIVISION ...... ...... ........ Post Office Box 9960 1101 Texas A venue College Station, Texas 77842-0960 (409)764-3570 1 September 12, TO: FROM: Taylor,C.,C..~.Creations,..'205N.. .Main, Bryan Garrett, <larrettEngineering , Bry.an Project Review. com. mi.ttee:. ............... .... .~~.....l\.... Jim ~allawayu Director of Plannin~ David Pullen'l City E.ngineer Doug Moore & Randy Michel, P&ZRepresentatives Others attending: Harry....Davis, 'Fire Marshal LaVern Akin, GTE Coy Perry , Btli.lding Official Bill Riley, Water & Sewer Division KeanRegister, Lone Star Gas Co. Jim Smith,PllblicServices Department 'Kim~ohnson ,Ass i st antPlann er SUBJECT: Parking Lot Plfln-ttC. C. Creations" - to be located()nLot lRRegency Square subdivision (Hc)lleman& Wellborn Rd. ) -(88~412) The P.R.C.meton.Septem'ber 7, 1988 to review the subject project,and approvedthE~projectwith the following condi.t'ions*: 1. Maintain an 8 foot Dlinimum required setback along Holleman Drive. Sh<>w thisdimens ion on site plan. End islands must be. a minimum of 180 square feet. 2. Show tabulations on the site plan of the breakdown of square footages of s~pace to be for office use and that to be used for warellouse so that parking requirements can be documented. 3. The drive entrance i.s adequately separated from the proposed Zip'Nand the proposed Judd's. 4. Approval ofdrainag€~reportispending review by Mark Smith. 5. City Engibeer David Pullen expressed concern regarding how delivery trucks will maneuver on the limited driveway areas on the site. 2 6. The FireMarshaLstafedfhe parking and/or loading areasiinfrontof<.f.ireconnections .mus t.be . removed, and a15footclearancemustbe<maintainedon each side of the fire connections.. Coordinate locations of fire lanes>with the Fire Marshal's office. 7. Coordinate turn--around'requirements.for the south end oft~edrlvewaY/parkingl.ot with the Fire Marshal's office. 8. Indicate what will be used to satisfyordinan.ce requirements regarding plant maintenance - .hose bibs or an irrigation system. If hose bibs areused,locate them on the site plan no farther than 150 feet from any landscaped area. All shrubs must be 5 gallon: size in order to received 10 points. (Exception would be dwarf specieswhichDlsy be I gallon in size.) 9. Coordinate telephone requirements with LaVern Akin of GTE. 10. Coordill.ate nat.ural' g:as'requirements with Kean Register of Lone Star Gas. SUBMIT 10 COPIES OF<REVISED SITE PLAN TO PLANNING DIVISION FOR APPROVAL PRIOR TO CONTINUIN.G WITH STEP I I OF THE BU I LD ING ...... .'.PERMITPROC ESS....~. *Any changes to an approved site plan must be cleared throughthePlaIlning '.Division. /c REQUIREMENTS FOR SITE PLAN PROPOSALS ,l./r)/ Sheet 5 J ze -24"x 3611 2) TItle block to include: ~at~ Project name, location and legal description ,.r'" t>'''o),: Name, address and telephone number of applicant ~~c}//Name,add ressandtelephone number.of developer/owne r J:~'l ,/Name ,address and telephone number of architect!engi neer. //"'~Date of .submit~al (6)~/Ownership and current zoning of all abutting parcels. LWr/Akey .map (not hecessarily to scale). ~r Scale should be 'largest standard engineering scale possible on sheet. 6) ..Ori ent <p lanw i thnorthdi rect iontoupperlefthandcornerofshee t. t/lf ",Topog raphy an~fi nalgradi ngp 1 an, and other pert I nentdra inage in format ion. ~.Allex!sting!streets,drlves, blJildings,and watercourses on Or adjacent ,.' tO,t hep ro pos,ed p roj ect site. ~r'. Lo;catel00year floodplain on or adJacent.to the :proposedproJect site. tJ{)"}"- Location and isizeof existing utilities within .oradjacent to the propos'ed project site. vr"l) Proposed location, type and size of the following: t.-S't,.. Bui ldi rigsandst ructu res b--/f)J~ Streets, drlvesand curb cuts L.~) Off-street parking areas with parking spaces drawn, tabulated and dimensioned. vd'l S Idewa 1 ks ve"r Landscape information as required in Section 11 of the Zoning Ordinance (Ord.No.1638). t,,,..f) Common open space sites vg') Sites for sol idwaste containers ,,/ vh) Proposed s i gnage ~)The total number of resIdential buildings and units to be constructed on the proposed //'" project site. ~jJ The total number of bedrooms included in the proposed project. 8,A"~} The densi tyof dwe 11 inguni ts. per acre of the proposed proJect. r;,,,,l'S) The gross square footage of all buildings and the proposed use of each -building. ~,..l6) The total site area and percent of buildlngcoverageofsite. ~,J-1') Des' gnate nurnberofpa rkfngspaces requiredbyord inanceandprovi ded byproposa 1. fff>"r'8) Show dimensions to size and locate all structures, parking spaces, drives, curb cuts, parking islands and setbacks. THE FOLLOWI NG ARETYP I CALSTANDARDS FOR PLAN DEVELOPMENT ESTABl I SHED BYORD I.NANCEOR POL ICY: 1 ) 2) 3) 4) 5) 6) 7) Building separatlonis a mInimum of 15 feet. Building setbacks are outlined In Ordinance 1638, Zoning Ordinance, Table A (Sec.],pg 30) MinImum parking space is91 x201, orona perImeter row, 91x 181 with a 21 overhang. Minimum drive width Is 23Iwlthhead.-inparkingor20Iwithout parking. Landscaped Islands of :6f1:raised curb are located at both ends of each parking row. Landscaped islands are also located every 15 spaces on inter lor rows and every 20 spaces on perImeter rows. A 611 raIsed curb isrequlredaround all edges of all parts of all paved areas without exception. (To include tslands, planting areas', access ways, dumpster locations, uti lity 'pads, etc.) Curb 'detailtobeapprovedby City Engineer. No except'ionswi 11 be made for areas designated as'lreserved forfutureparkingll. Standards for Plan Development (Continued) page 2 "8) 9) 10) 11 ) 12) 13) Wheel stopsrnaybe requ lredoni nterlorrows longer than 10. spacesori n special-situations. Sidewalks area mlnTmum4 ft . wideonsi te;6ft.wi de adjacent.topark ing spaces. DirectorofPublicServicesdeterminesnumber,sTze and approves location of dumpsters.~ Parking islandsare9'x20';or<180square feet. Heal thy~nati vet rees over 6".caliper should bereta ined whenever poss i b 1 e. CurbcutsaredetermlnedbyCityEngineer. Standards are one curb cut fora si tewlth125feet street fro-Ifltageandtwocutsfor250feet frontage>_ An additional 500feetoffrontagelsneededforeachadditional cut. In general, keep cuts at least 200 feet from major intersections. SeeOrd f nance1638Section .ll;.for landscapingrequ irements. Firelanes of a minimum of 20i<feet in width with a minimum hei~~tTlearance of 14 feet must be established if any structure of any typeist1lor~than 150 feet fromapubli.cstreet,orhighway. Any structure lnanyzoning ,district other than R-l,R-1A:orR-Zmustbe within 300 feet of .a firehydrantas'measured~longa public street or Jhiighway. Fire hydrants must be located ,on the same side ofamajor streetasa iproject, and shall beina locationap[.)rovedby the Fire Marshal'sioffice and the Super- intendent of Water and Sewer. Office or business facilities .inexcessof 5,000 sq. ft. must fl.lrnishparking spaces (m ini mum size 12' x 20' ) des i gnated for use byhandi capp~d ipersons onl y , with ramps .with no greatergradient>than 1 :12 and a minimumwiclth iof 4 feet. SEE SECTION 508 OF THE STANDARD BUILDING CODE FOR ADDITIONAL INFORMATION. 14) 15) 16) 17) 18 )