REQUIREMENTS FOR SITE PLAN PROPOSALS
SUBMIT APPLICATION AND THIS
LIST CHECKED-OFF WITH
10 COPIES OF SITE PLAN FOR REVIEW
-OR 5 COPIES &FILM POSITIVE
1) Sheet size - 24"x 36"
2) Tltl.e....b lock toi nc lude:
--~~~a) Project name, locat.i.on and l.egal..description
''''''"~,~b) Name, address and telephone number of applicant
"''"'''"~~c) Name, address and telephone number of deve loper/owner
) Name, add ress and telephone number of a rchi tect/ en9i neer
) Date of submittal
,-,'3) Ownership and current zoning of all abutting parcels.
4) A key map (not necessarily to seal e)_
~ Scale should be largest standard engineering scale possible on sheet.
"6'} Orient plan withnorthdlrection to upper left hand corner of sheet.
..:)k Topography and final grading plan, and other pertinent drainage information.
8) All existing streets, drives, buildings, and water courses on or adjacent
to the. proposedproj ect site.
~) LocallY~~ year floodplain on or adjacent to the proposed project site.
10) Location and size of existing utilities within or adjacent to the proposed project site.
11) ,Proposed location, type and size of the following:
a) Buildings and structures
\b)Streets, drives and curb cuts
, c) Off-street parklngareas with parking spaces drawn, tabulated and dimensioned.
'd) S idewal ks
{:) Landscape information as required in Section 11 of the Zoning Ordinance (Ord.No.1638).
r) Common open space sites
g\) Sites for solid waste containers
~~~e.~~~~f~~~m~;~n~~eresidential buildings and units to be consttucted on the proposed
.~ proJ ect sf te.
~) The tota I number of bedrooms i ncl udedin the proposed project.
,'-.~11t) The density of dwell Lng units per acre. of the' proposed project.
t5~) The gross square footage of all buildings and the proposed use of eachbui lding.
.~
~
~
The total site area and percent of building coverage.of si'te.
Designate number of parklngspaces required by ordinance and provided by proposal.
Showdimenslons to size and locate all structures, parking spaces, drives, curb cuts,
pa rk i n9 . isl ands . and setbacks_
THE FOllOWING ARE TYPICAL STANDARDS FOR PLAN DEVELOPMENT ESTABLISHED BY ORDINANCE OR POLICY:
1') Building separatlonlsamtnimumof 15 feet._
2i Building setbacks are outlined inOrdinance.1638, Zoning OrdInance, Table A (Sec.7,pg 30)
'3) MinimumparkingspaceLs 9' x 20',orona perimeter row, 9')<181 with a 21 overhang.
4) Minimum drive width is 23'with head-in parking or 20' without parking.
5) landscaped islands of.6'" raised curb are located at both ends of each parking row.
6) Landscaped islands are also located every 15 spaces. on interior rows and every 20 spaces
on per lmeter rows.
y) A 6" raised curb is required around all edges of all parts of all paved areas without
..,@xception (To include islands, planting areas, access ways, dumpster locations, utility
pads, etc,,) Curb detail to be approved by City Engineer. No exceptions will be made for
a reasdes i gnated as"reservedfor future pa rki ng'l.
Standards for Plan Development (Conrtinued)
page 2
8)
9)
10)
11)
12)
13)
Wheelstopsmay be required on !interior rows longer than 10 spaces or in
s pee i a 1 . s i.tua t ions. I
Sidewalks are a.minimum 4 ft. ,lrJide on site; 6 ft. wide adjacent to parking
I
spaces. I
DirectoroVPubl ic Services de!terminesnumber, size and approves location of
dumpsters... ... . . .... I
Parking ls.lands are.9lx 201; or. 180 square feet.
Healthy, native trees over 6"bal ipershouldbe retained whenever'possible.
Curb cuts are determined by Cih Engineer. Standards are one curb cut for a
sit~~ith125 feet streetfronFa?e and two cuts for 25?~eet frontage. An
addltlonal 500 feet.offrontage IS needed for each additional cut. In general,
keep cuts at least 200 feet frcbm major intersections
See Ord Lnance 1638 Section 11kor landscaping requirements.
Fire lanes of a minimum of 20 feet in width with a minimum height clearance
of 14 feetmust.be e~tabl iShedl if~ny structure of any type is more than
150 feet from a public street (Dr highway.
Any structure in any zoning di~3trict other than R-1 ,R-1A orR-2 must be within
300 feet of a fi rehydrant as reasuredalong a publ Ie street or highway.
Fire hydrants must be locatedIDn the same side ofamajorstreet as a project,
and shall be in a location appJ--ovedby the Fire Marshal's offlce and the Super-
intendent of Water and Sewer.
Office orbusinessfaci.1ities ;in excess of 5,000 sq. ft. must furnish parking
spaces (minimum size 121. x 201). designated for use by handicapped persons only,
with ramps with no greater gra(!jient than 1 :12 and a minimum width of 4 feet.
SEE SECTION 508 OFTHESTANDARlb BUILDING CODE FOR ADDITIONAL INFORMATION.
I
I
14 )
15 )
16)
17)
18 )
I
! .
'i.~;"'CITY OIF COLLEGE STATION
~~.. . PLANNING DIVISION
.. . Post Office Box 9960 1101 Texas Avenue
College Station, Texas 77842-0960
(409) 764-3570
Augus t5, 1988
MEMORANDUM
TO:
Kenneth K. Broach, 8124 Butler Ridge, College Station
Jack Cumpton, 4103 Texas Avenue, Bryan, TX
pr~... i:C~.a~.~:~:W.}T,.C~~~;~~.i. ~;. Of...Plannin~.... .. .. .j.
David Pullen, City Engineer g~
Steve Stewart & Donna Davis, P&Z Representatives
FROM:
Others attending:
Coy Perry, Building Official
Harry Davis, Fire Marshal -
Bill Riley, Water & Sewer Operations Manager
Ray Havens, Electrical Superintendent
LaVern Akin, GTE
Kim Johnson, Assis~tant Planner
SUBJECT: Site/Parking Lot Plan -ZIP'N FOOD STORE -603
Un Ivers i t}T Drive (88-409)
The P.R.C. met on August 3, 1988 to review the subject proposal,
and approv,ed the plans with, the following conditions*:
BUILDING DIVISION
A one hour firet\fallis req,uired along the rear of the proposed
expansion~ Coordinate w/Building Division to determine
handicap parking and restroom access requirements.
_;.:o';~'"_.~,,,_:_,~, ..._-.:...:..;;;:.;;:;.:.::..~.~~_ .
.. .'..~ . 'P _. - ... . .. - "'... -
':,~'~:~ h'E e""~RI=-e~=17-f~.-\kf'S:'-ION~""~::":~"-'~",:c~",,:=-'7"'''~.-=::'7-:~:-':----'" ,', '-':"'" ::,:-:.;-",-',-:"
Provide electrical load data. Locating the dumpster under
exi~ ti ng.... over.he<:id .eJ~.9tI',i9al.f~Gilit:ie~., .is..di$ cQurage,d.
Coordinate location tvith Jim Smith (Public Services) and Ray
Havens. Maintain minimum five (5) feet clearance between
expansion and overhead electrical conductors. Cbntractor should
exercise caution during construction due toproximit}r to
conductors .'
FIRE DEPARTMENT
Make sure contractor is familiar t-'lith local fire department
testing requirements.
#
P.R.C. 88-409
8-3...;.88
page 2
ENGINEERING DIVISION
Concerned wi th. existing\"loodenplatforlll (ramp) in Nagle ROW.
Coordinate with Engineering division to,determine any required
changes.
~~-~.~;:. :...:.'-\..;.'~--;=':...._~.;...;_._..._'.':':':":;:::;,::,,_..':""- .
. ..... . ... ". .. '. .' .. ""'~ .'... .... _.. , ... ',,,-