HomeMy WebLinkAboutApplication
APPLICATION FOR CONDITIONAL USE PE~IT Da~~R~~:~V:~' .-1-J;4?rt-;~--
st. Francis Episcopal Church for the Protestant ' --- __":"/-21 --
Applicant: ~.PJ-.P2.9.F~l-_.9E..!-!F_cE_.9.9~3_c2-1_.9!__~E~~Rl-~2~~~_~f____Phori~ : ('l9.2.L_9.2J.-:J.1Z2,___
'. Texas I
Address: P. O.Box9020; College Station, Texas 77840 .< . . . .
~~--~~~--~~~~~~---~-~-~~~-~-~~~~-~~~~~~,~----~~--~~--~--~-~----~---~-~--~
Location of Project':
Rock Prairie Road
--~-:...;..;..;-.~--~~.........__...~.~-~_....._-~-----~~___:~~...,~_~__~~~:____.~-''''~~_____''''_1____
Owner of land: Protestant Episcopal Church Council Of the Diocese of Texas.
----------------------~-..;,.--~-------:-------~--I--------------,---
I
Address of Owner: 520 San Jacinto; . Houston, Texas 77002: '. J.. .':.
---------.....---....---......------~-----------------.r~.--.-------:-------.---
Propoee4 Use: Cburch Facilities. .. .... .....1
-----------......'"':"'....----------.-----------------------r.------....----------
. I
I
Present. Use of property: -1!E:~~Y~!812~~__.....~-----------~--~__.....--L--------------.....-.---.
The applicant certifies that the above information is true andcorreqt:
~.~. ~........1
.. . .... ............. -~ ~_... -.. ~-T ..~ Ownpx-.__
Signature of . pplicant ~ndA:P:Plicant
!
IF APPLICATION IS FILED BYANAGDT J A POWEROFArroRNEY STATDmNTMUST BB INCJ~UDED.
A public hearing is required for a proposed conditional use peirmit. The appli<:ant
.is responSible for. placing an advertisement inth(:!paperat.le~tI5 days prior to
the public be~ring.Tlj.ePlanningDepartment will prepare the.iad. All propert~,
owners within 200 feet must be notified of the publichearing~ITheCity PJrepares
::i~:~lsS::eb;d~~~~~c=:~o:ot~e~::o:ei~lio~nc:::l~~:tr:::i:t:n~~.the City's Tax
I
Minimum Requirements: I
1. Ap~licationc~mpleted in fu~l.plus list of property. ~er~w.ithin 200 feet"
(C~ty Tax Off~ce prepares hstupon request from apphcan~.)
2. R.ece..1.......Pt....f. or.:r.. il.i.D. g. fee.....<.$. 25......00). Pl. us $..2...........00 .f........o....r.. e.ac. h...... p.r... op. e.~..t.y.... owne..r With. in.
200 feet as listed on the City Tax rolls. .ALI.OW48J1>ORSIFORPREPARATION OF
LIST I
3. Five (5) copies of site plan whichlncluderequirements fqr .siteplan
proposals as listed on attached sheet. This site planwi~l go to P.R.C.
'forreview,afterwhich ten (10) .revisedcopies of site pl~willbe
required.... .... .... .. . . I
4. Detailed explanationof.proposeduse including hours of operation, nwnber.()f
employees, number of students, children. church members. ettC.,BS
applicable.
5. If . 8i~ . ~s. planned. for 'project. site pIa should. iDclude . sign elevation ad
details. If sign details.. etc. ,are not included onthe p1aIls submi tted
with this application. any future sign must be considered as a separate
conditional" use permit 'and all of. theaboverequfrements must be. repeated~
1
SITE PLAN REVIEW APPLIC TION
. , ' . . DResidential
l{~~FPaQJECT ........-Sf,rr~~~\~ .....~C
ADDRESS H<9l. ~ Fll"a~ ~lel<._
LEGAL DESCRIPTION
RESIDENTIAL
Total Acreage
COMMERCIAL
otal Acreage--g-QGcte.;
uilding Square Feet .tBG.eo-s,~f'.
Floodplain Acreage ~c>...<
Housing Units
OWNER
~,~
PHONE
HONE ~ "'t~
HONE 4tS\~~111
PRESENT USE OF PROPERTY
PROPOSED USE OF PROPERTY
CURRENT ZONING OF PROPERTY
e-
"7~
V ARIANCE(S) REQUESTED AND REASON(S)
NillvffiEROF PARKING SPACES REQUIRED '00
PR~VIDED
SignatureofOwner,Ag torApplic:ant ... ...i
,1~
A11/1~
~ate
fonnslplanlsitcrccV8-9S
,)~
j;P1SGof<I\L ~H-oR..4+
SUBMIT APPLICATI()N AND THIS
LIST,CHECKEO..OFFWITH 16
FOLDED COPIES OF SITE PLAN ,FOR REVIEW
.p
MIN, I, MU,l\1, R,EO'U,I,RE,ME, NTS,. FORS,ITEPLAN,...P, R", 0, P, OS,ALS
(ALLClTYORDINANCES MUST BE MET)
INCLUDING-BUJ' NOJ'LIMIl'f,UTO .J'HE .FQLtQWIl'lG:
o 1. Sheet size- 24" x 36"
o 2. Title block to include:
a.)N8.[Il~' address, locatian,aIld!egc1ldescriptian
b.) . Name,address, andtelep~ane number afapplicant
c.) Name,address"andte\~Pl1ane llumber afdevelaper/awner ·
d.) Name, address,andtelepl1ane number af architect/engineer
e.) Date of submittal
f) Total site 'area
o 3. Ownership.~dcurrentzoning afparceland all abutting parcels.
~
o 4. A key map (nat necessarily to scale).
o 5. Scale shauldbe largest standard engineeringsca1e passible an sheet.
a 60 Provide a north arrow.
o 7. T apagraphy ,final grading plan, and ather pertinent drainage infa~tian.(If planhastaamuch
information,.' s4aw drainage an separate sheet.)
o 8. All existing streets, drives,buildings, and \Vater courses anaradjacenftatheprapasedipraject site.
o 9. Locate 100 ynfloodplainOl1oriadjacenttoth~ propasedproject site,.~()teifthereisn(>n~:an the site.
o 10. Locatianand.size ofexistil1gutilities withiniocadjacen.t to. theprQP~~;ijfQJ~site.
o 11. Prap()sedlocation,ityp~,an<isizeof the fallaWing:
a.) Bui1diIJg~and. strupt\1res
b.) Off-Street parking areas with parking spacesdrawn,tabulat~anddimensioned
c. ) Sidewalks
d.).. CaIIUllon..9penspa~.sites
e.) ; Sites for' solid waste containers
o 12. Propasedstreets~drive~,iandcurb cuts.Eor..eachpropos~curtbi~t.ifm~luding,dI"iyeways,. streets,
alleys,etc.)loca.teeps!iIlg;c\1rbcutsan the Same and apposit~side()~~estr~tadeter~eseparation
distances. betWeen existing and.prapased curb cuts. . Indicate driv~}YaYtlu'oat leIlgth..as . Illeasured in the
Driveway Ordinance. (See Ordinance 1961 for drive\Vay lacatian and design. requiremeIlts.)
o . 11.The tatalnumber af residet1tialbuildingsandunit~ to be .. construct~()nth~ propased project site.
o 14 .ymdscapeplanasirequire<liIlSectian.l1.oftl1ez;oping.()rdiJ;1an~.~~~()rdinan~.. # 163.8.. ) The
landscaBingplansaIlbe.shQ~. anaseparat~sh~t,it:;tOO1l11.lfh.infq~;l~anis oni.the oJjginal..site plan.
Attempt. to.. i r~1.l~QrelirI1in;).t~.plantings in easements; IncI1.lde.inf~rpta.tion. on theplan.SllCh. as:
a). existingJand.s~ping to.. remain ..
b). requiredpoil1tca1culatians .
c) proposed newplantings with paints~ed
o 15..Indicate unittype (numberofbedraams).
o 16. The density of dwelling units per acre aftheprapased.project.
o 17..The gross square faatageafbuildings andth~propaseduse of each building.
,"
o 18. Designate number of parking spaceS required by ordinance and provided by proposal.
o 19. Show dimensions to size andloc~teallstl1.lctures,parkirtg spaces, drives, curb cuts, Parkingislanc:is,and
setbacks. . .' .., .'. I .
o 20. Are there impact fees associated with this development?
o 21. Provide a water and sanitarysew~rlegend.tRincludewaterdemands(minimum,maJCimum and average
demands in gallons per minute) and sewer loadings ( maximum demands i*gallons per day). .
o 22. Show all metedocations;Meters IIl.ustbelocated in easements or Rq.W. (Citywillsizemeters.)
I
The following are typical standards'forPlan.Development established by' Ordinance or Policy:
o 1. Building separation isa minimum of 15 feet.
o 2. Building setbacks are outlined in Ordinance 1638, Zoning Ordinance, able A (Sec. 7, P. 30).
o 3. Minimum parking space is 9' X20', or on a perimeter row, 9' x 18' wi h a 2' overhang.
o 4. Minimum drive width is 23' withhead':'inparking or 20' without parJ' eg.
o 5. Raised landscaped islands,(61'..raisedcurb)ofamini~um of 180 sq. ..are located at both ends of every
parking row. 'Additionally, 180 sq. ft. oflandscapingfor every 15 int rior parking spaces must be
provided. . I
o 6. Streetscape. compliance is required which involves special. Plantingsl~ong streets specified in the City's
Streetscape .Plan. I
A 6"raised,curbis require<iaround.alledgesofallparts of all p~rvedareas without eKception. (To
include isl~ds,planting ar~s,<~ccess ways,dulI1Ps~er locations,u.ilitypads, etcJ, (;urb detail to be
Wheelstopsmay be required ()ninterior ro\Vs 10 nger than 10 spaces or in special situations.
~i1::~rt%sie~'r~~~l~l~r6f~;l~::~=~:rt&td~n~;en~:it~~~::~~ ;~~:
10.2 of the Zoning Ordinance).
o 10. Locationsofdumpsters,shallbe.suchthatdUIIlPsters are not visible om streets. Gates ure discouraged
and visual screening from R.O.W., is required.
o 7.
o 8.
(J 9.
a 11. Healthy, native trees over 6" in caliper should be retained whenever possible.
o 12. Fire 13,nesofaminimllmof20feetin wdthwitha minimum ltei&ht clearance of 14 feet must be
establishedif any structure of any type islUorethan 150Jeet from 1 public street or highway.
a 13. Any structure in any z()ning<<iistrictotherthaIllt-l,R-IA, or Rt2IIlust be within 300 feet of a fire
hydrant as measured along a public street Or.alongan approved fir~ lane as the hose is laid off the truck.
o 14. Fire hydrants musfbe locate<ion the same.sid~ofa major street ~aproject, and shall be in a location
approved by the City Engineer. I
o 15,. ,Fire hydrants must be operable and accepted by the City and driyesl11l1sthave an all weathersutface
before combustibles can,be brought on any site. · .
o 16. Atwentyfour foot setbackfromR.O.W. to curb of parking lot is,i required. Parking may be allowedin
this area up to . a maximum of 7 contiguous spaces. .' I
o 17. All plans must include irrigation systems for landscaping. Irrigation n1:CWCS are separate from the regular water
systems for buildings and must be sized accordingly and include backflo~ prevention protection.
site.
proposed project site.
BY ORDINANCE OR POLICY:
1)
2)
3)
4)
5)
6)
7)
Building separatIon lsamlnimum of 15 feet__
Bu lId I n9 setbacks are outlined In Ordinance 1638, ZonIng Qrd I nance, Table A (Sec. 7 ,pg 30)
MinImum parkIng space Is9'x 20', or ona perJmet.er row,j9' x18Jwitha21 'overhang.
Minimum drive width Is 231 .wlth h~ad;...ln parking or 20' wl~hout parking.
Landscaped 's-1 andsof<6"' ra ised curb are located at both ~~nds of each parking row.
Landscaped Islands are also located every 15 spaces on Interior rows and every 20 spaces
on perImeter rows. .
A 6" ra I sed curb i srequ I red around all edges of all part~ of a 11 paved areas wi thout
'exception. (To Include fslands,plantlng areas, access ways, dumpsterloc.ations, utility
pads, etc.) Curb detail to be approved by City Engineer. I No exceptions will be made for
areas designated as "reserved for future'parklng". 'I
I
I