Loading...
HomeMy WebLinkAboutApplication p&Z CASE NO.g~4t70 C fTY .OF COLLEGE .....STATfON ~ APPLICATION FORM SfTE.PLAN REVIEW Date December 2 3, 1986 ~ NAME OF . PROJECT Sandstone Center LOCATION/LEGAL DESCRIPTION Lot 1 ~ Baron Park; Robert Stevenson League -AbstractNo. 54 APPLICANT Sandstone Systems~ lnc~ PHONE (409) 774-4893 CJ Res i den t i a 1 rltI . Commerc i a 1 ADDRESS 305 ArgueHoDrive~ College Station~ Texas 77840 OWN~R Sandstone Systems, Inc. PHONE (409) 774-4893 PHONE (501) 793-5711 72501 of Bryan, exas ARCHtrECT ORENGINEER Herman Lee Architect~ AlA ADDRESS CURRENT ZONING OF PROPERTY C-l VARIANCE(S) REQUESTED AND REASON(S) None NUMBER OF PARKING. SPACES qEQUIRED As Determined NUMBER :OF PARKfNGSPACES PROVIDED 128 The applicant certifies that the above information is true and correct. ()r, Signature of owner IF APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER, A POWER OF ATTORNEY STATEMENT MUST BE INCLUDED. REQUIREMENTS FOR SITE PLAN ~ROPOSALS ...... ...;~S.~~,mrt1'6tf.fOI~mt"~~~~~~'~: .. -'."'~.: ./"'~ :- ;': \ .,., 8/-400 <i~ Sheet sIze - 24ttx36" 2) TItle block to Include: ~.A" Project name, locat Ion and I ega I descr I pt ion 4-Ja1' Name, address and telephone number of applicant A Name, address and telephone number of developer/owner ",d") Name, address and telephone number of architect/engineer "".~ Date of submittal Af Ownership and current zoning of all abutting parcels. ~ A key map (no.t necessarllyto scale). .$ Scale should be largest standard engineering scale possible on sheet. -61 Ori ent p I an wi th north direct ion to upper 1 eft hand corner of sheet. .;fY Topography and final gradIng plan, and other pertInent drainage Information. X All existing streets, drives, buildings, and water courses on or adjacent to the proposed project site. X .$ Locate 100 year floodplain on or adjacent to the proposed project site.(:ke-J1tl)~~ ~>6f" Location and size of existing utilities within or adjacent to the proposed project site. f~ Proposed location, type and 5 i zeof the following: ......aY Buildings and structures ..-* Streets, drl ves and curb cuts j:.V Off-street parking areas with parking spaces drawn, tabulated and dimensioned. :~ S Idewa 1 ks ...er Landscape Information as required in Section 11 of the Zoning Ordinance (Ord.No.1638). ~~ft Common open space sites '~. f.,.. Sit.e.s for .SOl.i.d. wn..... A.te.... c..5!...n.ta.i..ne..:. rs. ..J'r) . Proposed s i gnage( !p.c.<i-tr {'WV' ) .)4' The total number of residential buildings and units to be constructed on the proposed project site. J..31Io/N-Th~total nu'mber of bedrooms included in the. proposed project. JM~The density of dwelling units per acre of the proposed project. )-<< The,gross square footage of all buildings and the proposed use of each building. .t*. ,),81 The.total sIte area and percent of building coverage of site. Deslg~ate number of parkIng spac~s required by ordinance and provided by proposal · Show dimensions to size and locate all structures, parking spaces, drives, curb cuts, parklngislandsand setbacks. THE FOLLOWING ARE TYPICAL STANDARDS FOR PLAN DEV~LOPMENT ESTABLISHED BY ORDINANCE OR POLICY: 1 ) Bu i 1 d t ng se.paratlon i s a mIni mum of 15 feet. 2) Building setbacks are outlined InrOrdinance 1638, Zoning Ordinance, Table A (Sec.7,pg 30) 3) MinImum parking space Is 91 x 20', or on apertmeter row, 91 x 18' with a 21 overhang. 4) Minimum drive width Is 231 with h~ad-in parking or 201 without parking. 5) Landscaped Islands of ~'I raised curb are located at both ends of each parking row. 6) Landscaped Islands are also located every 15 spaces on Interior r~s and every 20 spaces on perImeter rows. 7)A 61' raised curb Is required around all edges of all parts of all paved areas without exceptIon. (To Include Islands, planting ~reas, access ways, dumpster locations, utility pads, etc.) Curb detail to be approved by City Engineer. No exceptions will be made for areasdeslgnatedias ureserved for future parking". ,... Standards for Plan Development {Continued) page 2 8) - 9) 10) 11 ) 12) 13) Wheelstops may be.requlredon interior rows longer than TO spaces or in special... situations · Sidewalks area minimum 4 .ft. wide onslte; 6 ft. wide adjacent to parking spaces. Director of Public Services determines number, size and. approves location of dumpsters. Pa.rking islandsare<9lx 20'; or 180 square feet. Healthy, native trees over 6" caliper should be.l-etained whenever possible. Curb cuts are determined. by City Engineer. Standards are one curb cut for a sitewith125.feet$treet frontage. and two cuts for 250 feet frontage. An additional 5.00 feet of frontage is needed for each additional cut. In general, keep cuts at least .200 feet from major intersections. See Ordlnan.ce1638 Sect'.ion 11. forlandscaping<requirements. Fire lanes of a minimum of 20 feet in:.widthwlth a minimum height clearance of 14 feet must beestaD li shed if aoystructure of any type is more than 150 feet from a public street or hIghway. Any structure in. any zoning distdctotherthan R-1, R-1A orR-2 must be within 300 feet ofa fire hydrant as measured along a public street or highway. Fire hydrants must be located on the same side of a major street asa project, and. shall be ioa location approved by the Fire Marshal1s office and the Super- i'ntendentof Water and Sewer. Office or business facilities in excess of 5,000 sq. ft. must furnish parking spaces (minimum size l21x 201) designated for use by handicapped persons only, with ramps. with no greater gradient than 1:12 and a minimum width of 4 feet. SEE SECTION 508 OF THE STANDARD BUILDING CODE FOR ADDITIONAL INFORMATION. 14) 15) 16) 17) 18)