Loading...
HomeMy WebLinkAboutMisc. City-of .College. Station F)OSl~ {)!::FICEBOX9960 1101 TEXAS AVENUE COI-JLEGE STATION, TEXAS 77840-2499 June 11 ,19'86 MEMORANDUM TO: Russell Bradley, DDS, 209 Dominik, College StatIon, TX 77840 "GregSimmons,P, o. Box 2602, Bryan, TX Project. RevIew Committee: ~~ Al ~ayo, Dlrect~r of P!annlng \:f............ DavrdPullen,Clty Engineer Walter Wendler & Steve Stewart, p&Z Representqtlves FROM: Othersattendfng: Carol Elmore, Assistant Cfty Attorney JImmy McCord, McCord Engtneertng, Inc. K.fmJohnson,Asslstant ZonIng OffIcIal Ray Havens, Acting EJectricalSuperfntendent Harry Davfs, FfreMarshal Shirley Volk,PlannlngTechnlclsn SUBJECT: ParkIng Lot Plan - AddItion to existIng dentIst offlce at 209 Domlnlk (86-412) The P.R.C, met on thIs date to revIew the above mentioned project, and approved the prbjectwlth the fallowing condltlons*: 1. FurnIsh electrical load data requirements to Electric Department. 2. Place some. type of temporary curbing along the western property line from the sidewalk at rear of buIlding to rear property lIne. 3. A 6" rafsedcurb Is required around all edges of all parts of all paved areas wlthoutexceptlon. (To Include Islands, plantIng areas, access ways, dumpster locations, utilIty pads, etc.) Curb detail to be approved by the CIty EngIneer. No exceptIons wlll be made for areas Indicated on sl-te pI anas'lreserved for future parking". 4. Reverse locat1on of lslandsln therea~ of proposed addItIon from west sfde of property to east srde~ 5. Parallel parkIng spaces should bea mInImum of 22 ft. In length. 6. The P.FCC. recommended that the applicant secure an access easement from the owner of the shopping center adjacent whlch would guarantee access to the parkIng spaces In the rear of the proposed office. 7. The FIre Marshal stated that guaranteed access to the rear of the building Is crucial to the Fire Department~ therefore Is required. 8. MInImum landscapIng point requirement for thIs project Is 500 poInts, 250 of whIch must be In canopy trees. Recalculate landscapIng for thIs project and fnelude a table as required by ZonIng OrdInance. 9. Locate and designate eIther irrigatIon or hose bIbs. Designate type of groundcover to be used. 10. Show exIsting easements and utilIties IncludIng the manhole. 11. Assistant Director of PublIc Services has stated that curbsIde garbage bag plckup 15 acceptable for this project. SUBMIT 10 COPIES OFREV1SEDPLAN TO PLANNING DEPARTMENT FOR APPROVAL PRIOR TO CONTINUING WITH STEP, ,of THE >f3UILDING PERMIT PRnrJ:"~~ ~~^_. __L_