Loading...
HomeMy WebLinkAboutMisc. Bill Tap Construction Company, Inc. 764-9053 March 31,. 198.7 Mrs. JaneKee City of College S.tation Planning Department P. O.Box 9960 College Station, Texas 77840 RE: CO for Post Oak II Addition 1100 Harvey Road Dear Mrs. Kee: Enclosed you will find a copy of the contract between The Greenery and the owner of Post Oak II as per our conversation. Permission isreque.sted that we be. allowed the obtain. final inspection and Certificate of Occupancy with the understanding that the land- scaping will be completed by April 15, 1987.. Thank you for your consideration in this matter. Sincerely, Bill Taparausk.as BT/lt Enclosure 1501 F.M. 2818, Suite 1-12 P.O. Box 9559 College Station, Tx. 77840 Transmittal ..... ........................ ~....,. .......~."'.~()t .' .' "Summit Plaza West 12 Greenway Plaza Suite 7'10 Houston, Texas 77046 713/965-0608 P8R PBR Architects, Inc. TO: tJ,7Y SN4/NilCI't CI'Y4G ~.f:1Jf1'Jrw ATTN: PROJECT: 1OSr..04~ .$l.MWell PROJECT NO:/',,- WE TRANSMIT: [ 1 herewith [ ] underseparatecoverv-ia [ ]in accordance with your request FOR YOUR: [ 1 approval ] distribution [ .. ) Information [ ] review & comment ] record [ } use ] COPIES DATE DESCRIPTION I '-30-'(" REMARKS Ii" *11... .1MVJ6/41.' ..iN1/1 A~W' l. Ate 4111CAJ/Nt( ,,811M lr If enclosures are not as noted, please inform usimmediatety. (with enclosures) D o D D. o COPIES TO: ee..Q.~~C:;;~ ?- ~ ~ lc.....~ ~.~~ ~Q.\ ctQ.~<..c.. kt. 1 ~15 ~c.....4IA-- d . - p~.+-...., .J2..tr h..........cr? s,., ~.-- ~ - c2-.c.-,-~ .\-b~.U.""'..Lt "'-b --- (;1U(\%~ crcJ{\~ .. .......~ <1-~~~g lS? ~ Q). ~~~..L~~J c.--D'~. ~s~ ') ("'\A" (H"~19--. p ~"0u ....~ \0. ~,~ ~ .(12.oJ~~ ~ ~ S\~......A"--r~. WL \tS~ .-rr.r~ '-1 ~,Sl~. M ~.If.'. ... ..City ofColltlgeStation ........ ~. ............... .... .......... ....p.......O.......ST.O. p.'. FIC. E ..B.. 0..... ..X........ 9.........9......6. ..0...... ....... ...1.. ......1. ..O.l.T...... ....EX. AS. . .t\....V.........E.................N............LJE ~ ~ '..COLLEGESTATION, TEXAS 77840 Engineering Division April 9, 1986 MEMORANDUM TO: Daniel L. Boggio,PBRArchi tects,.Inc., 12 Greenway Plaza Ste 710, Houston MargaretA. Lundgren, Lister Property. Co.., 1104E. Harvey Rd.., C. s. Project ReviewC6mmittee: ..,.,\"......\CV Jim. Ca.llaway, Assistant Director of Planning \.~'\ David Pullen, City'Engineer Celia Stallings, P&Z .Representative FROM: Others attending: Joe Guidry, Electrical Superintendent Jane.Kee,Zoning.Official Bob Epps,iAsslstant Director.Public Services Bland Ellen, Deputy Fire Marshal Carol Elmore, Assistant City Attorney Jimmy < McCord, McCord Engineering, Inc. ShirleyVolk, Planning Technician SUBJECT: Parking Lot Pl. an - Addition to Post Oak Square Shopping Center -86-404 (Located on partofa 15.027 acre tract in the Morgan' Rector. League as described inVolwne525, Page. 613 of the DeedRecords.of Brazos County, which is owned at this time by Raymond D. Lister, Jr.) The P.R.C. met on this date to review the above mentioned project, (at which time the applicant 'srepresentative,DanBoggio,- · furnished information that this lease space will be llsed for retail uses and not for a restaurant), and. approves with the following conditions*: 1.. The dumpster can .b.e located.. in the vicinity of the existing dumpster for the orielltal restaurant in the adjacent building. Any location. chosen must be coordinated. and approved by the. Electrical.Department and the Assistant Director of Public Services. .Ifthedumpster is located in an easement, clearance must be allowed under. the utility lines for emptying the dumpster. Mr. Epps suggested that perhaps a l2x20 foot pad be poured which. would accommodate additional dwnp~:;ters which may be required in the future. 2. Show the location of the nearest fire hydrant. A hydrant must be located within 300 feet of all parts of all buildings as/the hose lays. 3. Furnish electrical load data to the Electric Department as soon as possible. If underground service is required, . furnish a. letter requesting same. The de'~eloper is responsible for the cost of boring for underground service, as well as the cost difference between ..overhead .service alld ullderground service. 4. Although the City Engineer did not point out any problems, he reminded the 1 P.R.C. 86-404 4-9-86 applicant of the fire wall requirements and the parking spaces for the handicapped, both of which are covered by the Building Code. 5. HE: Landscaping a. Include a note regarding use of hose bib or tie-in to existing irrigation system. b. Grass or groundcover (indicate choice) is required in the swale. 6. For purposes of signage, this entire shopping center.is considered one building plot, and no additional freestanding signs will be allowed. Businesses in this buildirig will be allowed to advertise on the existing shopping center freel:;tanding sign, or that sign can be replaced with multiple low profile signs. See S~~ction 12 of Ordinance 1638, the Zoning Ordinance. 7. The site plan as presented and reviewed at this'meeting is inadequate to be approved as a fillal si teplan. Redraw plans at a scale of 1: 10 or I: 20 (on 24x36 paper), and include all adjacent portions of the shopping center which are both developed and undeveloped, as well as all information shown on this plan. Also include additional dimensional information. SUBMIT 10 COPIES OF REVISED SITE PLAN TO PLANNING DEPARTMENT FOR APPROVAL JPRIOR TO CONTINUING WITH STEP II OF THE BUILDING PERMIT PROCESS. *Any changes to an approved site plan must be cleared through the office of the Director of Planning. 2