Loading...
HomeMy WebLinkAboutMiscellaneous City. of College Station POST OFFICE BOX 9960 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 November 2, 1982 TO: MEHORANDUM FROM: Planning & Zoning Commission Tim Keneipp, 511 University Dr. East, SUiSC,Z_O_4,.. ',/ ,,' Project Review Committee: ~ . Jim Callaway, Asst. Director of Planning~ E lreyAsh, Director ofCapi tal. 'Improvements Jim Behling, Chairman p&Z Other Staff: Harry Davis, Fire Marshall Jane"'Kee, 'Zoning Official J'oe Guidry, E lectri ca lSuperi ntendent Mac Allen, Director of Public Services Jim Mc.Cord, Elec. Power Engr. Bill Cupp, GTE DlckWylie" GTE S hi rley Vo 1 k, P lan'ni ng T echn i c i an SUBJECT: Parking Lot Plan - Central Park Atrium -,82-447 The P.R.C. met on Novembe.r' 2,1982 to 'review parking lot plan for the"above mentioned project. TheP.R.C. recommends approval with the following conditions:~t~ I ( 1) \ No obstructions wlllbe allowed which would interferwith crews reaching dump- s ters (gates,fence's,etc . ) SuggeStperha ps Ilbeefi ngl .up the parking lot in the dumpster area. Keep,pavlnglevelat the dumpster 'area. Dumpster locations to be cleared-w.ith the Dlrector of Pub1ic Services. , - Locate fi re hydrant at thenorthea;st corner 'of the east driveway entrance. Sprlnklersystemwll1 be required for entire building upon completion. Utility service to be at the norther;n'corner of the property. 'Check with Electrical Superintendent. Access easement running down the northwest side of the property line will be required if the boulevard entrance (off Central Park Lane) is to be used. Both openings in the parking lot to the adjacent lot should, be at least 40 ft. in width to allow circulation of garbage trucks. Sign located on Southwest Parkway sidewill be limited to address only. Drainage plan showing elevations, flow plan, etc. will be. required prior to approval of this plan. Eliminate the turn lane from Southwest Parkway and make the, curb cut the same as on any other city street. (2) (3) (4) (5) (6), (7) (8) (9) *Any changes to the approved site 'plan must be cleared through the Office of the Directcirof Planning. NEED 10 COPIES OF REVISED PLAN BY 5:00 P.M. NOVEMBER 12th TO BE INCLUDED ON NOVEMBER' l.Sth' .,AGENDA'. BU I LDI NG PERt\1IT APPLICA,TION July 8, 1 983 PROJECT: Central Pa rk Atri um APPLICANT: Sentry construction~..,... .. P. O. Box 4787 . . ~. ENGINEERING COMMENTS: 1. All easements shown on Drawing No. MEP 1 must be current instruments or field notes prepared for the samebya registered land surveyor ,pravi ded to thi S offi ce and an easement document drawn and executed prior to issuanceofa Certificate of Occupancy. 2. An easement may be':needed foY' the fire hydrant if located as shown and for the firesprinkl er vaLrlt~~also. 3. The sanitary sewer connection is not acceptab'le as shown. A manhole will be required at the termination of the existing 6 inch line. Detai 1 s .>must be worked out with the Water and Sewer Dept. A plan and p'rofile of the sanitary sewer line if extended will be required. /. .~ ~ '- << ~?('~.tK..J 7-1'2 r 2, 3, /