HomeMy WebLinkAboutMiscellaneous
(7)
(8)
(9)
(10)
City. of College Station
POST OFFICE BOX 9960 LIOITEXA.S AVENUE
COLLEGE STATION, TEXAS. 77840-2499
March 22, .1983
MEMORANDUM
TO:
Plannlng&Zoning Commission
Jack Teague
FROM:
v
Project Review Committee:
AIMayo, Dlrectorof Planning
Jim Behling, Chairman p&Z
David Pullen, City Engineer
Other Staff:
Harry Davls, Fire Marshal
Joe Guidry, Electrical Superintendent
Dan Oupies, Ass'tto Zoning Official
Jim t4cCord,Elec . Power Engrs.
Shirley Volk, Planning Technician
SUBJECT: Parking Lot Plan- BULLDOG Auto Care (83-41S)
TheP.R"C. met on March 22, 1983toreview,the above mentioned'project, and
recommends approval wIth the followingconditions:;'~
( l)
A 6"raised curbls required around all edges of all parts of all paved
areas without exception. (Tolnc 1 ude islands ,planti ngareas, access
ways, dumpster locations, uti 1i typads, etc.) Curb detaIl to . be approved
by CftyEnglneer. No .except ionsw ill be' made, fora reas <i'n,d i cated,on site
plana 5 t'rese rvedforfuturepark lng".
Anadditlorialfl re<hyd rantwlllberequ ired at aloca tionapp roved by
the Fire Ma.rshal and <the Water '&Sewer Superintendent.:<All parts of
the buildingmustbewithln 300ft. oft.hehydrant as:thehose lays.
InstallatJonplansmust be drawn by a registered Professional Engineer.
Ordinance requiresan8 ft. setback from the propertyltne along Holleman
Drive {front setback). Show. actual dimension onsite'plan.
Suggest the sidewalk in front' of the building be made>6ft. in width;
(2 ft. ofthi s sidewalk can then' be used for wheeJstops) .
Dumpster location and size to. be approved by the Director of Public
Services.
Island at the corner 'of the building should be 9 ft. in width. Whether
this additional wldthcan come from the driveway must be determined by
the Oi rector ofpublicServi ces(Mac All en).
The painted island shown on sit.e plan should be changed to a raised curb
island, and should meet ordinance requirements.
Include anQtetoindicate plantings to be used.
Include an elevation of the planters.
When electrical load requJrements<aredetermined, contact Joe Guidry.
(2)
(3)
(4)
(S)
(6)
SUBMIT 10 COPIES OF REVISED PLAN TO THE PLANNING DEPARTMENT BY 5:00 P.M. THURSDAY,
MARCH 31 TO BEl NCLUOEDON ~P&ZAGENDA APRJ L7th.
;'~Any changes to the approved plan must be cl eared through the Office "of the
Director ofPlannjng.
i I !
~d4.
. S3-f/~
'1', ~. . ~' /f'. ~
I < ~...... .....}iJi.~. ,'~:-"-'-".~.:.......a:.~. :... .......... :'.'" ... ...__............,.x,............~.. ........~.$
1..,.,. ~~ RC7ZP:;C}L ,j)/.. .4J~.o.-0