HomeMy WebLinkAboutMiscellaneous
~ie",e & 'l.Oi~cltlfte"er, 9"c.
CONSULTING ENGINEERS
W...I. WISCHMEYER, PRESIDENT
..I. T. MILLICAN, VICE PRESIDENT
E. R. McDOW, ..IR., P.E.
A. F. KRAUSKA
P.C.R. SHELLEY
15 September 1982
Mr. Jim Callaway
City Planning Department
City of College Station
P.O. Box l;;Il;;I60
College Station, Texas 77840
Re: Sewer Capacity in Area of
35 Acre Zoned M-2
Dear Mr. Callaway:
This letter will serve as a memo regarding our meeting today. The capacity of the
15" trunk sewer which would serve the above referenced site is limited in capacity.
This capacity is limited because of the wet weather overflow from the 10" line in
Christine Lane and the 12" overflow at Bee Creek Park. Based upon the existing
dwelling units in place and what is proposed on a 35 acre tract east of Holleman
Drive, north of Loop 2818, the trunk sewer is at maximum capacity.
The area west of Holleman Drive and north of Loop 2818 is therefore growth limited
by the above overflows. If this area is to develop, it would require the construc-
tion of a 24" sewer from By-Pass 6 west to Southwood Drive along Bee Creek. This
would allow for a 3600 PE capacity increase of the existing 15" trunk sewer serv-
ing this area. (This is a proposed improvement in the Year 2000 Plan.)
I hope that this information is helpful to the City's planning of this area. If
you have any further questions, please call.
Sincerely,
~~J) rv{JNevv-
Edward McDow
cc: Mr. Elrey Ash, II, P.E.
Director of Capital Improvements
Mr. Al Mayo
City Planner
HOME OFFICE
11325 PEGASUS STREET, SUITE S-209
DALLAS, TEXAS 75238
(214) 348-3255
BRANCH OFFICE
1701 SOUTHWEST PARKWAY, SUITE ...IDD
COLLEGE STATION, TEXAS 77840
(713) 696-8630