MANHOLE SIGN
(SEE DETAIL l-E)
STANDARD MANHOLE RING L COVER
EXCEPT AS SHOWN ON PLANS
(SEE GEN. NOTE 4)
NON-SHRINK GROUT (FIVE STAR
GENERAL PURPOSE OR APPROVED
EQUAU
GROUND
MECHANICALLY COMPACTED AT 6' LIFTS
TO 85% MODIFIED PROCTOR (ASTM D1557)
A T MINIMUM 2% OVER OPTIMUM MOISTURE
(UNLESS SPECIFIED OTHERWISE ON PLANS
MORTARED RINGS FOR
ADJUSTMENTS TO FINISH GRADE,
AS REQUIRED (24' MAX HEIGHT>
PRE-CAST MANHOLE
PER ASTM C-478
'0' RING GASKET <TYP.>
(SEE GEN. NOTE 3)
MANHOLE RISER PIPE. INSTALL PLUMB L LEVEL. SET
BEFORE POURING BASE (HEIGHT DETERMINED BY DIAMETER
OF SEWER PIPE L NOTCH-OUT SIZE)
6' MIN. FOR PRECAST
12' MIN. FOR CAST - IN-PLACE
PRE-FAB NOTCH-OUT
FOR PIPE
SET BOTTOM OF MANHOLE RISER
AT CENTER OF PIPE
SEE SPECIAL NOTE 3
CAST-IN-PLACE OR PRE-CAST
BASE - 3000 PSI CONCRETE
(SEE SPECIAL NOTE 2)
CAST IN PLACE
WI CONCRETE BOTTOM
PROVIDE BELL JOINT
AT ENTRANCE L
EXIT OF ALL
MANHOLES
DETAIL I-A
PRECAST MANHOLE
(ASTM C478)
SPECIAL NOTES'
1. ALL JOINTS AT MANHOLE SECTIONS L OTHER OPEN OR
COLD JOINTS, OR LIFTING HOLES, SHALL BE THOROUGHL Y
FILLED WITH SYNKO-FLEX OR OTHER APPROVED MASTIC
WATERPROOFING MATERIAL.
2.CONCRETE FOR MANHOLE BASE SHALL CURE FOR MINIMUM
OF 24 HOURS PRIOR TO PLACING ADDITIONAL SECTIONS.
3. POUR OR SET BASE ON FIRM UNDISTUBED SOIL IF SOIL
IS WET, MUDDY, OR SOFT, THEN UNDERCUT UNSTABLE
MATERIAL L BACKFILL WITH CRUSHED STONE OR GRAVEL.
4. (N.A.S.P.D
SEE SPECIFICATION S-204 DETECTOR TAPE FOR
INST ALLA TION AT MANHOlES.
18' JOINT DUCTILE IRON PIPE,
CLASS 350 W 18 MIL POL YWRAP
PIPE
r
BACKFILL IN 8' LIFTS
TO 85% DENSITY - 95%
DENSITY IN TRAVELED
ROADWAYS
VARIES
(MIN 2'-0'),
. .
DUCTILE IRON PIPE
CLASS 350, SAME
SIZE AS SE'WER
MAIN OR ONE
SIZE LARGER IF
NOT ABAILABLE
IN SAME SIZE
AS MAIN
FLOW LINE AT
TOP OF MAIN
LINE PIPE
DETAIL I-D
DROP
CONNECTION
MANHOLE DECAL
MH 668
CARSONITE CUM 375
6' GREEN MARKER POST
CITY OF COLLEGE
STATION DECAL
P - 2097
BRACE A T EACH
JOINT TO 10.. D
PIPE IN PLACE
IJHILE BACKfILLING.
NOTE:
SIGNS NOT REQUIRED FOR
MANHOLES LOCATED ALONG
STREET RIGHT -OF -WAYS
NOTE: SIGNS AVAILABLE FROM
JIM COX SALES
2819 ANODE LANE
DALLAS, TX 77845
MANHOLE
DETAIL 1-E
IDENTIFICATION
NTS
SIGN
STANDARD MANHOLE RING
L COVER
(SEE DETAIL 4-A')
24'
SE PRE-CAST CONCRETE
GRADE RINGS @ MORTAR
R BRICK L MORTAR AS
EQUIRED TO RAISE TO
GRADE
6'
3000 PSI CONCRETE
DUoLITHIC POUR
VARIES
['
12'
HI
(SEE GEN. NOTE 5)
f
2' THICK 2000 PSI CAP
LIMIT FOR INITIAL POURING
OF CONCRETE WHEN FIRST WALL
SECTION IS NOT CONSTRUCTED
'WITH FOOTING
DETAIL 1 B
STANDARD
CAST - IN PLACE
MANHOLE
GENERAL
1NEJj~~~ TYPE MANHOLES, PLACE CONCRETE FOOTING OR BASE
ON FIRM SOIL OR OVER EXCAVATE TO FIRM SOIL AND
BACKFILL WITH STANDARD GRADATION CRUSHED STONE.
2. ON CAST IN PLACE MANHOLES, ALLOW FOOTING OR BASE AND
FIRST SECTION OF WALL TO CURE A MINIMUM OF 24 HOURS
BEFORE SETTING ADDITIONAL WALL FORMS AND PLACING
CONCRETE IN FORMS.
3. PRECAST MANHOLE SECTIONS SHALL CONFORM TO ASTM C478.
JOINTS SHALL BE 'o'-RING GASKETED. IN LIEU OF
THICKNESS AS SPECIFIED IN C478, SECTION 7, DESIGN-THE
MINIMUM THICKNESS FOR MANHOLE RISERS SHALL BE AS
LISTED UNDER 'WALL '8' IN THE CLASS TABLES' OF ASTM
C76, REINFORCED CONCRETE PIPE.
4. MANHOLE COVERS 'WILL BE MARKED 'SANITARY SEWER: PICK
BARS OR LUGS SHALL ALSO BE CASED IN MANHOLE COVERS.
NO OPEN HOLES ALLo'WED IN COVER. THE CAST IRON RING
AND COVER SHALL BE FURNISHED L INSTALLED BY
CONTRACTOR.
5'MANHoLE BASE OR FOOTING THICKNESS (CAST-IN-PLACE OR
PRE-CAST> AS FOLLOWS,
MANHOLE DEPTH (FT.>
0-8
8-12
12 8. OVER
THICKNESS <IN.)
8
10
12
3' 7'"
STANDARD SAN. c.r
SE'WER CLEANoUT BOOT
AND COVER OR EQUAL.
2000 P.S.I. CONCRETE
STOPPER
CLEANoUT STACK
45' BEND
IF NOT ON UNDISTURBED EARTH,
CONCRETE CUSHION MUST PE PLACED
AROUND SEWER LINE.
NOTE, MINIMUM SIZE CLEANoUT TO BE 6'.
2000 P.S.I. CONCRETE.
DETAIL 3-F
SEVER LINE
CLEAN OUT DETAIL
15' FllR 5' DIA
30' FllR 6' DIA.
.i
VI
w
Q!
i
;i
.....
:1:
.
<t'
ru
z
i:
.
ru
-
6' MIN.
6' MIN.
8' MIN
APPROX.
"'EIGHT
RING - 17:541
COVER 1251
DET AIL 1-C
TRANSITION DET AIL FOR 51 8x 61
DIA.
CAST-IN-PLACE MANHOLES
4' STOPPER
__ 4' PIPE - LENGTH VARIES
4' 45' BEND.
NOTE.
6' PIPE FCR
IIlJUBLE SERVICE
4' BRANCH.
~
'!
"
<t.
..
2000 P.S.I. CONCRETE.
DET AIL 3-G
SE\JER LINE
ST ACK DETAIL
SAN IT ARY
RING AND
PROP. 4' SANITARY SE'WER SERVICE
LINE. MINIMUM SLOPE OF li8' PER FT.
S' MIN. AT
END OF SERVlCE
J
22-3/ ' 32'
MACHINE SURFACES
PATTERN 300-24
MANIO..E RING L COVER
SEWER
COVER
NOTE'
6' LINE FOR
DOUBLE SERVICE
THE PIPE SHALL BE PVC CONFORMING
UNDISTURBED GRoU"lD; FILL IS REQUIRED A TO ASTM D2241 SDR 26, CLASS 160 OR
CONCRETE EMBEDMENT 'WILL BE NECESSARY. SCHEDULE 40 UTILIZING CLASS 1245-A
PVC COMPOUND. THE OUTSIDE
PROPOSED TEE o~ WYE (4' BRANCH). DIAMETER SHALL BE IPS STANDARD
(STEEL PIPE DIAMETER).
PROPOSED SANITARY SEWER MAIN.
SE\JER LINE
SERVICE LINE CONNE:CTION DETAIL
PAVEMENT
4' 0"
4' SAN. SEWER
SERVICE LINE
6' FOR DOUBLE
SERVICE
PLUG \
'WITH OR 'W /0 SIDE'W ALK &/OR 'W A TER LINE
DETAIL 3- D
SE\JER LINE
SERVICE LINE DETAIL
tiS"
MATERIALS FOR EMBEDMENT - KEY
~ SELECT MATERIAL
MATERIAL EXCAVATED FROM THE DITCH WHICH IS FREE OF
ROCKS, LUMPS, CLODS, OR DEBRIS LARGER THAN TWO (2)
INCHES IN THE LARGEST DIMENSION. COMPACTION OF THE
MATERIAL SHALL BE TO AT LEAST 90% OF THE MAX. DRY
DENSITY AS DETERMINED BY ASTM D-698 AT A MOISTURE
CONTENT OF -2 BELOW TO +6% ABOVE THE OPTIMUM MOISTURE
CONTENT OF THE MATERIAL.
QD GRANULAR MATERIAL
MATERIAL SHALL BE BANK RUN SAND WHICH IS FREE
OF DETRIMENTAL QUANTITIES OF CLAY, DEBRIS, OR ORGANIC
MATERIAL AND WHICH, WHEN TESTED BY STANDARD
LABORATORY METHODS, MEET THE FOLLOWING REQUIREMENTS,
MAXIMUM LIQUID LIMIT 45
MAXIMUM PLASTICITY INDEX 15
MAXIMUM PERCENT PASSING NO. 200 SIEVE 15
MINIMUM PERCENT PASSING 3/4' SIEVE 100
@ CEMENT STABILIZED SAND
THE MATERIAL SHALL BE GRANULAR MATERIALS MEETING THE REQUIREMENTS
OF MATERIAL MBM ABOVE MIXED WITH PORTlAND CEMENT AND DESIGNED TO
PRODUCE A MINIMUM UNCONFINED COMPRESSIVE STRENGTH OF 50 PSI IN 48
HOURS AND 100 PSI IN 7 DAYS WHEN COMPACTED TO 95~ DENSIIY IN .
ACCORDANCE WITH ASTM 0558 AND CURED AND TESTED IN ACCORDANCE WITH
ASTM 016.32 AND ASTM 016.3.3. THE CEMENT -SAND MIXTURE SHALL BE
COMPACTED IN 8M LIFTS AT OR NEAR OPTIMUM MOISTURE CONTENT.
FIELD MIXING OF CEMENT STABILIZED SAND IS ACCEPTABLE.
CEMENT -SAND MIXTURE USED FOR SANITARY SEWER EMBEDMENT WITHIN
9 FEET OF A WATERLINE SHALL CONTAIN A MIN. OF 2 SACKS OF CEMENT
PER CUBIC YARD OF MATERIAL.
IN IT IAL BACKF I LL
8' MIN. - 12' MIN.'
WHEN TRENCH DEPTH
IS GREATER THAN 10'
METAL WARNING TAPE
(24' BELOW GRADE)
SELECT MATERIAL
QD(MANUALLY CONSOLIDATE
AT OPTIMUM MOISTURE)
6' MIN.
QD(SPADE BY LIFTS INTO PLACE,
TO FILL ALL VOIDS AROUND
PIPE. MANUALLY CONSOLIDATE. )
THE TRENCH BOTTOM SHALL BE
GRADED SO AS TO PROVIDE UNIFORM
AND CONTINUOUS SUPPORT FOR THE
PIPE BARREL BETWEEN BELL HOLES.
MIN. 112' MAX.
BEDDING AND BACKFILL FOR
SANITARY SEWER PIPE
NON-STRUCTURAL AREAS
SECTION
ETAL WARNING TAPE
(24' BELOW GRADE)
6'
~ SELECT MATERIAL
6' MIN.
@(MANUALLY CONSOLIDATE
AT OPTIMUM MOISTURE)
QD INITIAL BACKFILL
QD(SPADE BY LIFTS INTO PLACE,
TO FILL ALL VOIDS AROUND
PIPE. MANUALLY CONSOLIDATE. )
THE TRENCH BOTTOM SHALL BE
GRADED SO AS TO PROVIDE UNIFORM
AND CONTINUOUS SUPPORT FOR THE
PIPE BARREL BETWEEN BELL HOLES.
MIN. 112' MAX.
BEDDING AND
SANITARY
STRUCTURAL
BACKFILL FOR
SEWER PIPE
AREAS
REVIEWED FOR
COMPLIANCE
MAR 2 7 200
SEWER LINE CONSTRUCTION NOTES:
COLLEGE STATION
ENGINEERING
1.
All public infrastructure construction shall be in accordance with the current
City of College Station Standard Specifications for Water & Sewer Construction.
All construction shall be coordinated with the City Engineer's office. Private
sanitary sewer line construction shall be in accordance with the City of College
Station Building Code.
All sewer line materials, structures and appurtenances shall meet current
City standards and details. Alternate materials shall be allowed only if the
Contractor receives written approval from the City Engineer.
Manholes, either cast-in-place or frecast, shall be constructed and
installed in accordance with curren City of College Station specifications
and details. Standard manhole rings and covers shall be used.
The compaction of the backfill material shall be verified by in-place
density. tests. The rate of density testing shall be determined by
The City of College Station inspector.
The construction shall comply with OSHA Standard 29 CFR Part 1926
Subpart P for trench safety requirements. General information on trench
safety is presented on the Trench Safety Details sheet.
Sewer lines shall be tested for exfiltration and TV inspected prior
to acceptance. All manholes should be leak tested either by the
water or vacuum method.
2.
3.
4.
5.
6.
7.
Upon completion of construction the Contractor shall provide a
set of .. red-lined" drawings marked "As-Built" to the City
Engineer.
I C Copyright 2003 by R. L. Payne & Associates, Inc.
ISSUE DATE
3-13-03
PROJECT NO.
E072
DRAWN BY
CCS
CHECKED BY
JPS
REVISION
D
D
D
D
D
z
o
t)
VJ
~ lJ')
o <t'
... 00
u ~
ClS <n
ti "0 ~
c:: <il 4J
o 0 f-<
U"'c:......
-; j .~ ~
~ tJ <.I) 0
~ l? ~~
r~ S =a R
v~u~
W
I-
I-
Q)
+-'
C c: (/)
Q) 0 as
(.) -- X
(/) <D
--
en > I-
--
en 'U ...
Q) .c c: ..
C ::l 0
--
+-' en ......
.- m
LL. ~ ......
<D en
-0 <D CD
C '- C)
U
ctS <D
- ~ -
Q) -
0 0
.-
C) -- U
...J
C>
<:(
U Cf)L
Uo
Z -u
J: .
a..w .q-
- ~~
...-
...-
en (!)<t: CD
~~ I
W z~ ill
en ~ ())
(!)~ ill
...J (j)~ /""""-.,
- - W~ ())
~ U 0 f'-.
a: ())
0 0 '--/
W a: .q-
en 0 X
0 W ...- <t:
en I- t{)LL
Z ..q-
a: <( - w
-f-~N
W (!) (f) f'-. f'-.
~ Z N
~ Z ~~ X f'-.
W Z f-I
W ::s ~ ill
Z (L z~())
en a.. 0 ill
~ - 0-
>- W ~ f-/""""-.,
a: <t: <t: ())
::> 0:::: f- f'-.
a: 0.. I- w (f) ())
~ UL '--/
. Wwt3..
...J !::: w w
J: ()) -1 Z
- UO~O
Z .
a: a:t{)OI
<( c:( ...- U (L
en
1 .. z. $"...0 ~
SHEET:
C7