MODEL: The OMNI T2 meter operation is based on advanced
Floating Ball Technology (FBT) with an operating range of 1.0 (.23
m3/nr) ® 95 % min. to 250 gallons per minute (57 m3kr) @ 100 %
+!- 1.5 % registration of actual throughput. The meter is also rated
for continuous flows up to 200 gallons per minute (45 m3/hr).
CONFORMANCETO STANDARDS: The OMNI T2 meter meets
and far exceeds the most recent revision of ANSI / AWWA Stan-
dard C701 class II standards. Each meter is performance tested to
ensure compliance. All OMNI meters are NSF Approved to the lat.
est standards.
PERFORMANCE: The patented measurement principles of the
OMNI T2 meter assure enhanced accuracy ranges, an overall
greater accuracy, and a longer service life than any other compa-
rable class meter produced. The T2 meter has no restrictions as to
sustained flow rates within its continuous operating range. The
floating ball measurement technology allows far flows up to its
rated maximum capacity without affecting undue wear or accuracy
degradation.
CONSTRUCTION: The T2 meter consists of two basic assemblies;
the maincase and the measuring chamber. The measuring cham-
ber assembly includes the "floating ball" impeller with a coated
titanium shaft, hybrid axial bearings, integral flow straightener and
an all electronic programmable register with protective bonnet.
The maincase is made from industry proven Ductile Iron with an
approved NSF epoxy coating. Maincase features are; easily
removable measuring chamber, unique chamber seal to the main -
case using a high pressure o-ring. testing port and a convenient
integral strainer with optional drain/debris-flushing ports.
OMNI ELECTRONIC REGISTER: The T2 electronic register con-
sist of a hermetically sealed register with an electronic pickup con-
taining no mechanical gearing. The large character LCD displays
AMR, Totalization and Resettabie Test Totalizer. OMNI register
features; AMR resolution units that are fully programmable, Pulse
output frequency that are fully programmable, Integral customer
data logging capability, Integral resettable accuracy testing fea.
ture compatible with AR-5000 Testing Assistant Program, Large,
easy -to -read LCD also displays both forward and reverse flow
directions and all with a 10-year battery life guarantee.
MAGNETIC DRIVE: Meter registration is achieved by utilizing a
fully magnetic pickup system. This is accomplished by the mag-
netic actions of the embedded rotor magnets and the ultra sensi-
tive register pickup probe. The only moving component in water is
the "floating ball" impeller.
MEASURING ELEMENT: The revolutionary thermoplastic, hydro
dynamically balanced impeller floats between the bearings. The
patented Floating Ball Technology (FBI) allows the measuring ele-
ment to operate virtually without friction or wear, thus creating the
extended upper and lower flow ranges capable on only the OMNI
T2 meter.
2" OMNI T2
SERVICE
Measure of potable water,
Operating temperature range of 331(.56°C)-1507
(65.6-C).
OPERATING
100% - 1.5% from 1S-25O GPM .(.34-57m/hq
RANGE
LOW FLOW
95%-101.5%®1.0 GPM (.23m Por)
MAXIMUM CONTINUOUS
200 GPM (45 m /hr)
OPERATION
MAXIMUM INTERMITTENT
250 GPM(57 m31hr)
OPERATION
PRESSURE LOSS
7.0 psi 0200 GPM (AS bar®45m Por)
MAXIMUM OPERATING
200 PSI(13.8 bar)
PRESSURE
FLANGE CONNECTIONS
2" U.S. ANSI B16.1 / AWWA Class 125
REGISTER
Fully electronic sealed register vrBh programmable
registration (Gal. /Cu.Ft/ Cu- Md.I lmp.Gai /Acre FL)
Programmable MARrAMI reading and pulse outputs
Guaranteed 10year battery fife
NSFAPPROVEO
Maincase: Coated Ductile Iron
MATERIALS
Measuring Chamber. Thermoplastic
Rotor"Floating Bali": Thermoplastic
Radial Bearings: Hybrid Thermoplastic
Thrust Bearings-. Sapphire/Ceramic Jewel
Magnets: Ceamk Magnet
Strainer Screen: Stainless steel
Strainer Corer. Coated Ductile Iron
Test Plug: Coated Ductile Iron
STRAINER: The OMNI T2 with the'V" shaped integral strainer
using a stainless steel screen along with patented Floating Ball
Technology (FIST) create a design that gives far improved accu-
racy even In those once thought questionable settings. A remov-
able strainer cover permits easy access to the screen for routine
maintenance. Optional drain ports, located at the back lower cor-
ners of the strainer body, allow for easy discharging of debris with.
out the need to remove the cover.
MAINTENANCE: The OMNI T2 meter is designed for easy mainte-
nance. Should any maintenance be required, the measuring
chamber and / or strainer cover can be removed independently.
Parts and or a replacement measuring chamber may be utilized in
the event repairs are needed. Replacement and Measuring Cham-
ber Exchange are available under the Sensus MMP Program for
the T2 meters and this program may also be utilized for retrofitting
to competitive meters to achieve increased accuracy and
extended service life.
3Y'NOY `GF&NSti6Yi#bPSYY
//////////MINIM"��// /I///�t♦�////////////////
. ///////// Tl//////////////
�����t•r.r.rrr.r..�i�/////// MOMMMMOM
■■■■■■■■■■
Register with —
Pulse and AMR
v-C
r Stremer Cover
Dire
ction _ L AN —
of Flow —
F - Bolt Circle'{17 ti
G - No. of Bolts '�' S"
H - Size of Bolts Maincase
-Strainer Screen
Charnber Test
1�-- Assembly Plug
w
T' Rotor
Meterand
Pipe Size
Normal Operating
Range GPM
Minimum Maximum
Dimensions
Net
Ship -
ping
Weight
Connections
I A
B
C
D
E
F
G
H
Weight
2'
ON SOmm
1.0
.23m31hr
250
57malhr
Flanged
17"
7-7l8'
1'
5-3/4'
2-5li6'
4-1YL'
2
5/8°
27.41bs.
34.5lbs.
432mm
1200mm
1 25mm
1 146mm
I 59mm
I 114mm
1 2
1 16mot
112.42kg
15.65 kg
r n
�<i AUTHORIZED SENSUS DISTRIBUTOR
r s,• kTN�. ,..... _
� : SeNSUS Uniontown$ PA 15401 Gallatin Avenue
METERING SYSTEMS 1-800-METER-IT•1-8D0.638-3748
Fax: Direct to Factory
Local: 724-439-7729 • Toll Free:1-800-888-2403
vNAvsensus.com (select'North America Water)
Email: h2oinfo@sensus.com