Loading...
HomeMy WebLinkAboutDrainage DesignASH & BROWNE ENGINEERING, INC. Engineers and Consultants P.O. Box 10838, College Station, Texas 77842 979-846-6914 877-245-4839 Fax:979-846-8914 February 26, 2003 Spencer Thompson Development Services City of College Station P.O. Box 9960 College Station, Texas 77842 Re.: Drainage Design for the City Limits Restaurant Fedora Subdivision, College Station, Texas ABEI # 1051001 Dear Mr. Thompson: This letter summarizes the drainage design for the Fedora Subdivision (The City Limits Restaurant) on Wellborn Road in Southwest College Station. GENERAL LOCATION AND DESCRIPTION Location The Fedora Subdivision consists of a 1.128 acre tract of land, lying and being situated in the Robert Stevenson League, Abstract No. 54 in the City of College Station. The property is adjacent to Wellborn Road and the abandoned Graham Road right of way. The Edelweiss Business Center surrounds the subject property on two (2) sides. Description of Property There are no drainage ways or tributaries within or adjacent to the subject property. The property is crowned in the center producing 4 drainage basins, A, B, C & D (See Attachments). The storm water run-off from the basins is conveyed to the North Fork of the Lick Creek Drainage Basin via sheet flows across adjoining properties and the Wellborn Road drainage ditches. The property is located in the unshaded Flood Zones ' X', outside the 500-Yr. flood plain, as shown on FIRM (Flood Insurance Rate Map) map, Map Number: 48041 C0182 C, effective date of July 2, 1992. Runoff Calculation Method Runoff for all areas was calculated based on the "Rational Method". The runoff coefficients of 0.4, 0.5 and 0.75 were used for natural grassland areas, gravel -grass mix, and the developed areas, respectively. Intensity was determined by using the calculated time of concentration for each drainage area. As a result of the drainage areas being of minimal size, the Time of Concentration (Tc) was less than the required minimum standard of 10 minutes as lined out in the City of College Station's Drainage Requirements. Hydraulic Calculations As shown in Table 1.1 and Table 1.2, detention facilities were required for Basins B and D. Weirs (curb cuts) were utilized to meter the release of the increased storm water production. The weirs were hydraulically modeled using the weir equation, Q=C„, * L * Hex' and the Hydraflow software 'Hydrographs 6.02' for Basins B & D for crest lengths of 9" for both. The stage discharge curves for both weirs are attached for your review. DRAINAGE FACILITY DESIGN General Concept Once the site is developed, the majority of the site will consist of a parking area and a proposed restaurant building. A majority of the run-off will be captured in the parking areas and released via curb cuts in Basins B and D. Basins A and C did not incur any increases in storm water production due to the development. The following table illustrates the existing and proposed runoff for the project site and the flow increase/decrease for the drainage basins: Table 1.1 Existing/Proposed Runoff Existing Runoff Proposed Runoff w/o Increase/Decrease (cfs) Detention (cfs) (cfs) Storm Frequency (yr) Storm Frequency (yr) Storm Frequency (yr) 5 10 25 50 100 5 1 10 1 25 1 50 100 5 10 25 1 50 1 100 Basin 0.54 0.60 0.69 0.77 0.81 0.54 0.60 0.69 1 0.77 0.81 0.00 0.00 0.00 0.00 0.00 A Basin 0.76 0.85 0.98 1.10 1.15 1.43 1.59 1.83 2.06 2.15 0.67 0.74 0.86 0.96 1.00 B Basin 1.14 1.27 1.47 1.64 1.72 0.58 0.65 0.74 0.83 0.87 (0.6) (0.6) (0.7) (0.8) (0.8) c Basin 1.14 1.28 1.47 1.65 1.72 2.14 2.39 2.75 3.09 3.23 1.00 1.12 1.29 1.44 0.00 D Notes: If flow increase is greater than 0.5 cfs detention is required. Based on the above information, the project site requires detention in Basins B & D. This will be facilitated by storing run-off in the parking lot areas and controlling the release of run-off out of the parking lot areas via curb cuts located in Basins B & D. The metered outfalls plus the remaining surface run-off of the landscape areas and the remaining building areas will be less than the pre -developed run-off conditions. Table 1.2 Existing/Proposed Runoff with Detention Facility Existing Runoff Proposed Runoff Increase/Decrease (cfs) w/Detention (cfs) (cfs) Storm Frequency (yr) Storm Frequency (yr) Storm Frequency (yr) 5 10 25 50 100 5 1.10 25 50 100 5 10 25 50 100 Basin 0.54 0.60 0.69 0.77 0.81 Detention Not Necessary (0.5) (0.6) (0.7) (0.8) (0.8) A Bas in 0.76 0.85 0.98 1.10 1.15 0.76 0.83 0.92 1.00 1.13 0.0 0.0 (0.1) (0.1) 0.0 B Basin 1.14 1.27 1.47 1.64 1.72 Detention Not Necessary (1.1) (1.3) (1.5) (1.6) (1.7) C Basin 1.14 1.28 1.47 1.65 1.72 1.08 1.18 1.31 1.44 1.48 (0.1) (0.1) (0.2) (0.2) (0.2) D Notes: If Flow increase is less than 0.5 cfs, the impact on the downstream flow path is considered to be negligible. Compliance with City Standards From the information that is presented in this report, we have shown that the development of this site will meet the City's policy. Sincerely, ASH &,BROWNE ENGINEERING, INC. attis, P.E. Engineer .. ' JOE I. GATTIS .............I !.% . 90964 PRE—DEV BASIN 'A' AREA = 0.139 AC Q(25)r.) = 0.69 cfs Q(100yr.) = 0.81 cfa PRE—DEV. BASIN 'B' C = 0.5 AREA = 0.247 AC (SHEET FLOW) Q(25yr.) = 0.98 cfs (SHEET FLOW) Q(100 yr.) - 1.15 cfs i C=0.4 EDELWEISS BUSINESS EDELWEISS ; ' ' CENTER BUSINESS , i i , , (SHEET FLOW) CENTER (SHEET FLOW) (SHEET FLOW) �� —✓ PRE=DEV BASIN V (SH I OW) AREA - 0.370 AC Q(25yr.) = 1.47 cfs �q \ Q(100yr.) = 1.72 cfs PRE— EV BASIN 'D' EDELWEISS C = 0.4 AREA 0.371 AC \� BUSINESS Q(25yr.)- 1.47 cfs CEN TER = M 2 cfs \ C — 0.4 U� — (SHEET FLOW) Q �OF %•••••••e,: *�) ATTACHMENT##1 ,E1.GATTIS " D PRE -DEVELOPED DRAINAGE •••••••••••••� BASINS 90964 a 9 e® •iii•:••• SCALE: 1" = 20' 'IONALEN ASH EA.&. Ed Cb.EWmm 6, INC. 0�'_� y0' Cngiomrs and ConsWtmis P.O. Box 10838, College Station. Te 77842 �.... 1051001-003-01 979�46G914 B]7d4t-1639 Faa: 979-646-8914 DEVELOPED BASIN 'A' AREA = 0.139 AC Q(25)r.) = 0.69 cfs Q(100yr.) = 0.81 cfs C = 0.5 EDELWEISS BUSINESS CENTER DEVELOPED BASIN IX AREA = 0.615 AC Q(25yr.) = 4.56 cfs Q(100yr.) =5.35 cfs C = 0.75 9" WIDE CURB OUTFALL TO DITCH FLOW LINE OF 000 JOE I. GATTIS r..... a....• . 90J64 _ J / EDELWEISS BUSINESS CENTER DEVELOPED BASIN 'B' AREA = 0.275 AC \ Q(25yr.) - 2.04 cfs Q(100)r.) = 2.39 cfs C = 0.75 9" WIDE CURB OUTLET SHEET FLOW OUTFALL (SHEET FLOW) (SHEET FLOW) / DEVELOPED BASIN 'C' AREA = 0.10 AC Q(25yr.) = 0.74 cfs Q(100yr.) = 0.87 cfs C = 0.75 EDELWEISS BUSINESS CENTER GRASS BERM 3'wx6"Ht. AATTACHMENT#2 B DEVELOPED DRAINAGE BASINS SCALE: 1" = 20' ASH & EROMYE ENGINEERING, INC. 0 5' 10, 2C Hnginmm and ConsWlems 1:77=mmmc=� P.O. Box 10838, College Station, Texas 77842 1051001-003-02 1 979-8466914 877-245-0839 Pat: 979E-068914 DEVELOPED BASIN 'A' AREA = 0.139 AC 0(25)r.) = 0.69 cfs Q(100yr.) = 0.81 cfs C = 0.5 EDELWEISS BUSINESS CENTER DEVELOPED BASIN 'N AREA = 0.615 AC Q(25yr.) = 4.56 cfs 0(100yr.) =5.35 cfs C = 0.75 9" WADE CURB OUTFALL TO DITCH FLOW LINE JOE 1. GATTIS 1."......... .90964 _r \ / EDELWEISS BUSINESS CENTER DEVELOPED BASIN 'B' AREA = 0.275 AC \ Q(25yr.) - 2.04 cfs Q(100yr.) = 2.39 cfs C = 0.75 9' WIDE CURB OUTLET SHEET FLOW OUTFALL (SHEET FLOW) (SHEET FLOW) / DEVELOPED BASIN 'C' AREA = 0 AC — = Q 25yr.) = 0.74 cfs Q 100yr.) = 0.87 cfs C = 0.75 EDELWEISS BUSINESS CENTER GRASS BERM 3'w x 6" Ht. AATTACHMENT#2 s DEVELOPED DRAINAGE BASINS SCALE: 1" = 20' ASH & BROWIYE ENGINEERING, INC. 0 5' 10, 20' Engin. and C"aaallaata P.O. Box 10838, College Station, Texas 77842 1051001-003-02 1 979-846-6914 877-245-4839 Fax:979-8468914 SUPPORT DATA a L O LL T N 2 2 O M N N t CL N L a1 ... O m 2 O O N O O O O O O SID 0 r M �N\. �+ >1 2 2 S O co O M O .r+ CL C� c L E 0 0 O N O I� N N r r O O SP b c O D, L O LL r' N T T 2 2 O d 11 O M N O 4r r. C. O t0 N = L E O y 2 O T O LO CZ) LO O •- O O SJD 0 : cn "O N a 0 ro a) u n r T 2 CL L r O L L } .Q W) 3 N U 0 U) O� A� m W � L L T N ce) O 0 0 2 2 2 O O T O 00 Cl) O CD U t CL co L E v � o d E 9+ t H O N O M CV T O S10 D 7G L O LL 272 ■,mow V/ m Im 0 H N (4) a6e}S O .N 'a zi L O LL U) m In 0 H L W e6e}S O M LO N N L U m N O U N LO O O O