HomeMy WebLinkAbout15-55 Cottages of College Station... JUNCTION BOYS ROAD EXTENSION Engineer's Estimate of Construction Costs June 1, 2015 Item # Description Unit Unit Price Quantity Total Site Preparation 1 Mobilization L.S. $20,000.00 1.0 $20,000 2 Demolltlon S.Y. $5.00 1120 $5,600 3 Construction Slakino L.S. $13,000.00 1.0 $13,000 4 Clearino and Grubblno Ac. $1,500.00 2.1 $3, 150 Paving Construction 5 Embankment for Street Conslrucllon (complete In place) C.Y. $10.00 3,900.0 $39 000 6 Excavation Street ConstrucUon (Includes removal/stockpiling topsoil & C.Y. $5.00 :olacinQ remainder onsltel $12,500 2,500.0 7 6" Chemicallv Stabilized SubQrade S.Y. $6.50 3,785 $24 600 8 7' Reinforced Concrete Pavement 13 500 osil S.Y. $55.00 2,504 $137 720 9 Sidewalk 14' Relnf. Concrete) S.F. $5.50 15,320 $84 260 10 ADA Accessible Sidewalk Ramos EACH $1,000.00 8 $8 000 11 Median Nose EACH $800.00 4 $3 200 12 Traffic Control L.S. $12,500.00 1.0 $12,500 13 Hvdromulch S.Y. $4.00 5 500 $22 000 14 Retailina Wall Handrails L.F. $100.00 90 $9 000 15 Retainlna Wall /0-4FTl S.F. $35.00 225.0 $7 875 16 6" Sch 40 PVC Conduit for lrriaation L.F. $22.00 120 $2 640 17 Strioina and Slanina L.S. $22,568.00 1.0 22 568 Dralna!'.le System Construction 18 15' RCP Pipe, (ASTM C-76, CL llll /Structural Backfill) L.F. 19 21' RCP Ploe, /ASTM C-76 CL llll /Structural Backfill\ L.F. 20 24" RCP Pioe /ASTM C-76 CL 111\ /Structural Backfill\ L.F. 21 36" RCP Rubber Gasketed Pipe, (ASTM C-76, CL lll-ASTMC443) (Structural Backfill) 22 42" RCP Pipe, (ASTM C-76 CL Ill) (Structural Backfill) 23 48" RCP Rubber Gasketed Pipe, (ASTM C-76, CL lll-ASTMC443) 'Structural Backfill\ 24 48" RCP 4:1 Precast S.E.T. 25 15" RCP 4:1 Precast S.E.T. 26 Standard 5' Recessed Inlet 27 Standard Junction Box 28 Trench Safety 29 Rock Rio-Rao Water Svstem Construction 30 8" PVC C900 Cl 200 Water Line Str. Backfill 31 6" PVC C900 Cl 200 Water Line Str. Backfill 32 8" x 22.5 dea M.J. Bend 33 8" x 45 deQ M.J. Bend 34 8' x 8' M.J. Cross 35 8"x 6" M.J. Reducer 36 8' M.J. Gate Valve 37 8" MJ Plua 38 6"x6' Tee 39 6" Gate Valve 40 6"x22.5 deq. Bend 41 6" MJ Plua 42 8" x 1-1/2' MJ Taoolna Tee 43 6" x 1-1/2' MJ Taoolna Tee 44 1-1/2' Double Water Service comolete 45 Tvoe K Coooor Tubln!l 46 Trench Safety 47 Connect to Exisllni::i System 48 16' Steel Encasement (By open cut) (318" Thick) (includes painting, casina soacers and end seals l I of2 L.F. L.F. L.F. EACH EACH EACH EACH L.F. S.Y. L.F. L.F. EACH EACH EACH EACH EACH EACH EACH EACH EACH EACH EACH EACH EACH L.F. L.F. EACH L.F. $65.00 76 $4,940 $85.00 55 $4 675 $95.00 309 $29 355 $160.00 85 $13,600 $180.00 168 $30 240 $230.00 7 $1,610 $5,000.00 1 $5 000 $3,000.00 2 $6 000 $4,000.00 4 $16 000 $4,500.00 2 $9 000 $5.00 700 $3 500 $75.00 25 $1 875 $70.00 361 $25 270 $60.00 833 $49 980 $800.00 $800 $800.00 8 $6 400 $1,100.00 $1100 $400.00 2 $800 $1 200.00 $1 200 $600.00 $600 $800.00 $800 $900.00 4 $3 600 $600.00 $600 $500.00 3 $1 500 $400.00 $400 $400.00 6 $2 400 $1 500.00 7 $10,500 $200.00 70 $14 000 $5.00 1, 194 $5 970 $2 000.00 $2 000 $100.00 69 $6,900 JUNCTION BOYS ROAD EXTENSION Engineer's Estimate of Construction Costs June 1, 2015 Item # Description Unit Unit Price Quantity Sanltarv Sewer Svstem Construction 49 8" PVC Sanitary Sewer (03034 SDR 26) 10-15ft Depth -Structural Backfill l.F. 50 12· PVC Sanitary Sewer (03034 SOR 26) 10-15rt Depth -Structural Backfill L.F. 51 12' PVC Sanitary Sewer (03034 SOR 26) 15-181t Depth -Structural Backfill L.F. 52 16' Steel Encasement (By Mechanical Bore) (3/8' lhick) (Includes painllno. caslnq spacers and end seals) w/ s· PVC (03034 SDR26) L. F · 53 20• Steel Encasement (By Mechanical Bore) (3/8' thick) (includes painting, casing spacers, and end seals) w/ 12" PVC (03032 SDR26) L.F. $100.00 456 $120.00 218 $150.00 36 $225.00 106 $250.00 97 Total $45,600 $26, 160 $5,400 $23,850 $24,250 54 4' Standard Manhole f10-15ftl EACH $7 500.00 2 $15,000 55 4' Standard Manhole (15-18(1) EACH $8 000.00 3 $24,000 56 Trench Safety L.F. $5.00 710 $3,550 57 Connect to Exist Svstem L.S. $3 000.00 1 $3 000 Erosion Control Construction 11::ros1on l;ontro11-'1an & :seaimentation l;Ontro1 (1nc1uaes s11t 1enc1ng, 58 construction exits, slraw bale barriers, inlet protection, grass seeding, and any other sedimentation control devices) BTU Street Llahtlna L.S. $15,000.00 1.0 $15,000 1 !Street Llahtino and Conduit I L.F. I $35.001 1 130.0I $39 550 °'''°''''"''''s,::.:::,:,~:1:::::.,·(:,:•:'<'·)·x:·,,i!:'/:,,,.\~,;~,,~"·~·";;.'·,,,,,,,,.:."<:;. /,1.'\,::\'3''.•;\,=1-.-ico:::,:;•:;\:>·::o·!BTU Street Llilhtln·a·isubtotal ;:::'\'·:·'·:i:i'''-'-"'l':.<,:::<$39 '550 2 of2 • Jason Schubert City of College Station P.O. Box 9960 Co llege Station, Texas 77842 MITCHE LL MM MORGAN RE: Cottages of College Station Phase 3 (FP) Dear Jason, Attached please fi nd the following : • Revised civil construction documents; • Revised engineering cost estimate • Thirteen (13) 11x17 hard copies of the final plat. June 1, 2015 The additional development permit fee will be paid when the contractor comes to pull the permit and the additional surety will be posted prior to filing the final plat. STAFF REVIEW COMMENTS NO. 2 Project: Cottages of College Station Phase 3 (FP) (FP2015-900055) PLANNING 1. Revise the Certificate of the Planning & Zoning Commission to add a blank in front "day of" so they day of the Commission meeting can be written in. This revision can be included on the mylar. REPONSE: This note has been modified as requested. 2. Please note that paid tax certificates will need to be submitted prior to the filing of your plat. RESPONSE: Understood. We will deliver these with the mylar. GINEERING COMMENTS NO. 1 (Original Comment) WL2 -The waterl ines crossing Junction Boys Rd. should be encased. It is preferable to drop the entire waterline crossing the street below the storm sewer and encase it all rather than only partially encasing it. 1 3204 EARL RUDDER FWY. S. • COLLEGE STATION. TX 77845 • l 979.260.6963 • f 979.260.3564 (\Vil ENGINEERING HVDRAULICS HYDROLOGY • UTILITIES STREETS SITE PLANS SUBDIVISIONS 1nfo@m1tchelldndmorgan com • WNW 1111Lchelld11dmorqan com I j j RESPONSE: This waterline has been dropped below the storm sewer and the encasement has been extended. (Original Comment) LS2 -Please shift canopy trees such that there is at least a 10-ft separation from the waterlines. Also, waterlines should be located at least 15-ft from any bu ilding. The waterline is still very close to proposed canopy trees near Buildings 5, 6, 8, 9, 16, 18, 20, and 44. RESPONSE: All trees have been adjusted accordingly. (Original Comment) FYI ... Additional Development Permit Fee in the amount of 1 % of the total public infrastructure cost will be required. Please provide an updated cost estimate including the revised sanitary sewer line location. RESPONSE: Understood. This additional fee will be paid prior to pulling the Development Permit. (Original Comment) FYl ... All infrastructure required for the final plat must be built or surety provided for it prior to the plat being forwarded to P&Z. Surety may need to be adjusted based on revised cost estimate. RESPONSE: We would like to post surety prior to filing since the timeframe to the P&Z meeting is short. »e,.e_ cl ~.&\C.e.. iJ'6 ~ ~ ~ IDie-. RD1 -It looks like part of the retaining wall will need handrails. RESPONSE: Handrails have been added to detail sheet and noted on RD-1. WL 1/WL2 -The waterline material should be labeled as C900-DR14. RESPONSE: This label has been changed. SS1 -Do you have written permission to construct the sanitary sewer line on the property north of Holleman Dr. S.? FYl ... The proposed PUE will need to be dedicated prior to issuance of the LOC. RESPONSE: Yes, this property belongs to Capstone as well. Understood, we will dedicate a PUE to cover this sanitary sewer line prior to requesting an LOC. SS1 -The proposed sanitary sewer line is dependent on the downstream sewer being constructed by the CRED/Cottages Ph.2 project. That sewer will need to be constructed and accepted prior to issuance of the LOC for this project's sewer line. What is the alternative if the CRED sewer line is not completed? 2 / RESPONSE: Understood. The alternative is to have either a shallow gravity sanitary sewer line that would need to be constructed of ductile iron pipe, have a private lift station, or grinder pump on site. SS1 -Please note TCEQ requirements at water/sanitary sewer crossings. RESPONSE: The scale on the sheet was wrong and it has been corrected. The separation distance is noted as 9' and a caution note to the contractor has been added. GREENWAYS 1. Please add B/CS Standard Sidewalk Details. RESPONSE: The sidewalk detail sheet has been added to the set. TRANSPORTATION 1. Traffic Comments per James Robertson: In an email sent to the engineering firm designing the roadway, dated Monday April 27th, Traffic Systems requested that the left turn bays have a total length of 200 feet. This request seems to have been ignored. Engineering justification for doing so should be provided. RESPONSE: All medians have been modified to have a 100' storage length and 100' taper length. These plans show an all-way stop at Junction Boys Road and the Private Roadway. Per the Texas MUTCD, an all-way stop requires an engineering study. I have not seen an engineering study justifying this all-way stop. RESPONSE: There was not a stop sign here just a stop bar behind the crosswalk. Since Junction Boys Road may become a major thoroughfare in the future , Traffi c Systems would prefer that this segment of roadway be designed without an all-way stop at this location. RESPONSE: The stop bar has been removed and replaced with a "pedestrian" sign with "arrow" placard. 2. For the separation between the stop bar and the crosswalk markings, the 5' should be from the edge of the stop bar to the edge of the crosswalk (creating 5' of pavement between the two). The measurement lines seem to be a bit off. Also, the one at the South Dowling intersection doesn't have a distance . 3 RESPONSE: This separation distance has been noted on the plans. If there aren't stop signs at the intersection the middle, the stop bars shouldn't be there. RESPONSE: We have removed the stop bars at the intersection in the middle. If you have any questions or comments, please feel free to call our office at 979-260-6963. cc: File 4 JUNCTION BOYS ROAD EXTENSION Engineer's Estimate of Construction Costs March 6, 2015 Item Oescriotion Unit Unit Price Ouantitv Total Site Preparation I Mobilization L.S. $40,000.00 1.0 $40,000 2 Demolitlon S.Y. $5.00 1120 $5,600 3 Construction Stakina L.S. $13,000.00 1.0 $13,000 4 Clearlna and Grubbina Ac. $1 ,500.00 2.1 $3,150 Paving Construction 5 Embankment for Street Construction (complete in place) C.Y. $10.00 3,900.0 $39,000 6 Excavation Street Construction (includes removal/stockpiling topsoil & C.Y. $5.00 2,500.0 I placlna remainder onsite) $12,500 7 6" Chemically Stabilized Subarade S.Y. $6.50 3 735 $24,275 B 7" Reinforced Concrete Pavement (3,500 psi) S.Y. $55.00 2,479 $136,345 9 Sidewalk 14" Reinf. Concrete) S.F. $5.50 15 320 $84,260 10 ADA Accessible Sidewalk Ramps EACH $1,000.00 8 $8,000 11 Median Nose EACH $800.00 4 $3,200 12 Traffic Control L.S. $12,500.00 1.0 $12 500 13 Hvdromulch S.Y. $4.00 5,500 $22 000 14 Street Liahtina and Conduit L.F. $35.00 1,130.0 $39 550 15 6" Sch 40 PVC Conduit for lrriaatlon L.F. $22.00 120 $2 64-0 16 Stripina and Sianina L.S. $21,610.00 1.0 21 610 Dralna!'.le Svstem Construction 16 15" RCP Pipe, (ASTM C-76, CL Ill) (Structural Backfill) L.F. $65.00 76 $4,940 17 21" RCP Pipe (ASTM C-76, CL Ill) (Structural Backfill) L.F. $85.00 55 $4,675 18 24" RCP Pioe IASTM C-76, CL Ill) (Structural Backfill) L.F. $95.00 309 $29,355 19 36" RCP Pioe IASTM C-76, CL Ill) (Structural Backfill) L.F. $160.00 85 $13,600 20 42" RCP Pioe IASTM C-76, CL Ill) (Structural Backfill\ L.F. $180.00 168 $30,240 21 48" RCP Pioe IASTM C-76, CL Ill) (Structural Backfill\ L.F. $230.00 7 $1,610 22 48" RCP 4:1 Precast S.E.T. EACH $5,000.00 1 $5,000 23 15" RCP 4:1 Precast S.E.T. EACH $3,000.00 2 $6,000 24 Standard 5' Recessed Inlet EACH $4,000.00 4 $16,000 25 Standard Junction Box EACH $4,500.00 2 $9,000 26 Trench Safetv l.F. $5.00 700 $3,500 27 Rock Rip-Rap S.Y. $75.00 25 $1 875 ~)/)'C+i~·,><;~~<hL\C,:\'<'..'c'.' i'>c\ ··~:;~~/0;;\'.:\C":;::;'i~;':\'i:?:!;\i:'i'/:~'>z.>:,/:\S<:>£::.::,;\\''.\.:~;::·:"~YP ralnag·ifSystem 'Subtotal 'i'\\':i:~',,c.:.·,:·::\;: ;~:;c/$125 795 Water Svstem Construction 28 8" PVC C900 Cl 200, Water Line, Str. Backfill L.F. $70.00 361 $25,270 29 6" PVC C900 Cl 200 Water Line, Str. Backfill L.F. $60.00 833 $49,980 30 8" x 22.5 dea M.J. Bend EACH $800.00 1 $800 31 8" x 45 doo M.J. Bend EACH $800.00 8 $6,400 32 8" x 8" M.J. Cross EACH $1,100.00 1 $1,100 33 S"x 6" M.J. Reducer EACH $400.00 2 $800 34 8" M.J. Gate Valve EACH $1,200.00 1 $1,200 35 8" MJ Plua EACH $600.00 1 $600 36 6"x6" Tee EACH $800.00 1 $800 37 6" Gate Valve EACH $900.00 4 $3,600 38 6"x22.5 dea. Bend EACH $600.00 1 $600 39 6" MJ Plua EACH $500.00 3 $1,500 40 8" x 1-1/2" MJ TaPPina Tee EACH $400.00 1 $400 41 6" x 1-1/2" MJ Tappina Tee EACH $400.00 6 $2,400 42 1-1/2" Double Water Service complete EACH $1,500.00 7 $10,500 43 Tvoe K Copper Tublna L.F. $200.00 70 $14,000 44 Trench Safetv L.F. $5.00 1194 $5,970 45 Connect to Existina Svstem EACH $2,000.00 1 $2,000 I of2 Item JUNCTION BOYS ROAD EXTENSION Engineer's Estimate of Construction Costs March 6, 2015 Descriotion Unit Unit Price CJuantitv Sanitarv Sewer Svstem Construction Total I 46 8' PVC Sanitary Sewer (03034 SOR 26) 0-10ft Depth -Structural 230 $21 ,850 Backfill L.F. $95.00 47 20" Steel Encasement (By Mechanical Bore) (3/8" thick) (includes 118 $29,500 painting, casing spacers, and end seals) L.F. $250.00 48 4' Standard Manhole (0-10ft) EACH $7,500.00 1 $7 500 49 Trench Safetv L.F. $5.00 112 $560 50 1.,,0nnect to r::x1st :system L.S. $3,000.00 1 $3,000 :·.::'ci:~:;.::·:2'':'<. :>.''''ii;t<'''~~;~:·,>.<>:,y<:'.·~'i"".:"!·i':'~·:>:'2}.:\<)'.t>~~:?'~""'"t.~:~;.;y::\~l\''·7~;;;:~:~sanlti:i'rY:·seweb'.SvsterifSubtotal ::;,:'''"'·~·':'Si>',·;:;,, ::c:'<<$62:'410 Erosion Control Construction ,1::ros1on vomro1 1"'1an & ::>ea1mentat1on c..;ontrol (mcluaes silt fencing, 51 construction exits, straw bale barriers, inlet protection, grass seeding, and any oth er sedimentation control devices) LS. $15,000.00 1.0 $15,000 The above construction estimate is based on the engineer's preliminary opinion of probable construction costs. This estimate constitutes our best judgment at this time. Please note that the engineer does not have any control over contractor or suppller workloads and the degree to which Inflation may affect project costs between now and the bid date. During construction, additional features may become apparent as the work progresses, which will result in an in e e in cost. .._,,,,,,,,,, -~""-;_ OF 1"1:-t ''' . .:-,,.,,¢:" ................ "'..r •• , / .:;''-:>,"'* .... ~•,,'· ~·... ... ... ~ i! * .. .. .... : ..... ll!rl:--:--b'L\cl"""~ULC..-f-f+-=-:'1-'-'-'1-==---'-=-='-+'_:o_ ~ ...... :.0 •• ~i'i'c"A"J ... B. ·M~N l'Je o 1ca JB Mo[ ~VER 1-. • • ""'\"'",.-\"~\·"'"'"77689'" iffi J ~ ~\ ~Q/~~ 11 O~.,:?,~GISi~~':,." &' .£ •• , ~~ ........... '<-~-=' '\,,'StON"-\..~--''"'''''"' 2of2 vr FOR OFFICE USE ONLY CASENO.: (5-$5 CITY OF C OLLEGE STATION Home ofTtxaI A&M Univmity• DATE SUBMITTED: 0'3 · I tQ · j S TIME: 12 :05 STAFF: +f\:S~------- FINAL PLAT APPLICATION (Check one) D Minor ($700) D Amending ($700) ~Final ($932) D Vacating ($932) 0Replat ($932) Is this plat in the ET J? D Yes [8J No Is this plat Commercial D or Residential ~ MINIMUM SUBMITTAL REQUIREMENTS: ./[g] $700-$932 Final Plat Application Fee (see above). ~ $233 Waiver Request to Subdivision Regulations Fee (if applicable) . .J lg] $600 (minimum) Development Permit Application I Public Infrastructure Review and Inspection Fee. Fee is 1 % of acceptable Engineer's Estimate for public infrastructure, $600 minimum (if fee is > $600, the balance is /, due prior to the issuance of any plans or development permit). v [8J Application completed in full. This application form provided by the City of College Station must be used and may not be adjusted or altered. Please attach pages if additional information is provided. / [8J Six (6) folded copies of plat. (A signed mylar original must be submitted after approval.) J.. [8J Two (2) copies of the grading , drainage, and erosion control plans with supporting drainage report. Y [8J Two (2) copies of the Public infrastructure plans and supporting documents (if applicable). ~ Copy of original deed restrictions/covenants for replats (if applicable). / [8J Title report for property current within ninety (90) days or accompanied by a Nothing Further Certificate current within ninety (90) days. The report must include applicable information such as ownership, liens, encumbrances, etc. . _ II s i. b ··f " ~ Paid tax certificates from City of College Station, Brazos County and College Station l.S.D. { p:--\Dr~ ~~:ti /~· The attached Final Plat checklist with all items checked off or a brief explanation as to why the~ are not. ..J NOTE: A mylar of the approved preliminary plan must be on file before a final plat application will be considered complete. If the mylar is submitted with the final plat application, it shall be considered a submittal for the preliminary plan project and processed and reviewed as such. Until the mylar has been confirmed by staff to be correct, the final plat application will be considered incomplete. Date of Optional Preapplication or Stormwater Management Conference _N_o_t_A~p~p_lic_a_b_le __________ _ NAME OF PROJECT C3 Development --------------------------------- ADDRESS Unknown at this Time SPECIFIED LOCATION OF PROPOSED PLAT: Near the intersection of Holleman Drive and North Dowling Road. APPLICANT/PROJECT MANAGER'S INFORMATION (Primary contact for the project): Name Mitchell & Morgan, LLP, C/O Veronica Morgan, PE E-mail v@mitchellandmorgan.com Street Address 3204 Earl Rudder Freeway South City College Station State Texas Zip Code 77845 ------ Phone Number 979-260-6963 Fax Number 979-260-3564 ---------------~ Revised 4/14 Page 1 of 9 PROPERTY OWNER'S INFORMATION (All owners must be identified. Please attach an additional sheet for multiple owners): Name Capstone-CS, LLC C/O Rob Howland, COO E-mail rhowland@capstonemail.com Street Address 431 Office Park Drive City Birmingham State Alabama Zip Code _35_2_2_3 ___ _ Phone Number 205-414-6400 Fax Number 205-414-6405 ---------------~ ARCHITECT OR ENGINEER'S INFORMATION: Name Capstone-CS, LLC C/O Amanda Wallis E-mail awallis@capstonemail.com Street Address 431 Office Park Drive City Birmingham State Alabama Zip Code 35223 ------ Phone Number 205-414-6400 Fax Number 205-414-6405 ----------------- Do any deed restrictions or covenants exist for this property? D Yes [g] No Is there a temporary blanket easement on this property? If so, please provide the Volume __ N_V-_'A __ and Page No. _N_VA_ Total Acreage 24.52 Acres ----------Total No. of Lots 2 R-0-W Acreage -------2.243Acres Existing use Irrigation Pond & Vacant-Undeveloped Proposed Use Irrigation/Retention Pond & Multi-Family Number of Lots By Zoning District 2 I POD Average Acreage Of Each Residential Lot By Zoning District: 11.22 I POD I __ _ ---'---___ / __ _ Floodplain Acreage 1.560 Acres ---------------------------------~ Is there Special Flood Hazard Area (Zone A or Zone AE on FEMA FIRM panels) on the property? I Yes IX No This information is necessary to help staff identify the appropriate standards to review the application and will be used to help determine if the application qualifies for vesting to a previous ordinance. Notwithstanding any assertion made, vesting is limited to that which is provided in Chapter 245 of the Texas Local Government Code or other applicable law. Is this application a continuation of a project that has received prior City platting approval(s) and you are requesting the application be reviewed under previous ordinance as applicable? IX Yes I No If yes, provide information regarding the first approved application and any related subsequent applications (provide additional sheets if necessary): Project Name: The Cottages of College Station City Project Number (if known): 08-00500007 Date I Timeframe when submitted: P&Z Approval -February 21 , 2008 Revised 4/14 Page 2 of 9 A statement addressing any differences between the Final Plat and Preliminary Plan (if applicable): tot applicable. Requested waiver to subdivision regulations and reason for same (if applicable): 'Not applicable. Regarding the waiver request, explain how: 1. There are special circumstances or conditions affecting the land involved such that strict application of the subdivision regulations will deprive the applicant of the reasonable use of his land. tot applicable. 2. The waiver is necessary for the preservation and enjoyment of a substantial property right of the applicant. f ot applicable. 3. The granting of the waiver will not be detrimental to the public health, safety, or welfare, or injurious to other property in the area, or to the City in administering subdivision regulations. f ot applicable. 4. The granting of the waiver will not have the effect of preventing the orderly subdivision of other land in the area in accordance with the provisions of the Unified Development Ordinance. f ot applicable. Fee in lieu of sidewalk construction is being requested because of the following condition (if applicable): 1. ~An alternative pedestrian way or multi-use path has been or will be provided outside the right-of-way; 2. ~ The presence of unique or unusual topographic, vegetative, or other natural conditions exist so that strict adherence to the sidewalk requirements of the UDO is not physically feasible or is not in keeping with the purposes and goals of the UDO or the City's comprehensive Plan; 3. ~A capital improvement project is imminent that will include construction of the required sidewalk. Imminent shall mean the project is funded or projected to commence within twelve (12) months; 4. ~ Existing streets constructed to rural section that are not identified on the Thoroughfare Plan with an estate I rural context; 5. tfpi. When a sidewalk is required along a street where a multi-use path is shown on the Bicycle, Pedestrian, and Greenways Master Plan; Revised 4/14 Page 3 of 9 6 . .,,, The proposed development is within an older residential subdivision meeting the criteria in Platting and Replatting within Older Residential Subdivisions Section of the UDO; or 7. tfjA The proposed development contains frontage on a Freeway I Expressway as designated by Map 6.6, Thoroughfare Plan -Functional Classification, in the City's Comprehensive Plan. Detailed explanation of condition identified above: I Not applioable. NOTE: A waiver to the sidewalk requirements and fee in lieu of sidewalk construction shall not be considered at the same time by the Planning & Zoning Commission. Requested Oversize Participation._N_o_t A_p_p_f1_·ca_b_l_e. _______________________ _ Total Linear Footage of Proposed Public: ~Streets l.9J2 Sidewalks 'l W San~ary Sewer Lines ' Water Lines Channels _Storm Sewers _!/)__Bike Lanes I Paths Parkland Dedication due prior to filing the Flnal Plat: ACREAGE: NIA No. of acres to be dedicated + $ __ N._VA __ development fee NIA NIA NIA OR No. of acres in floodplain No. of acres in detention No. of acres in greenways FEE IN LIEU OF LAND: NIA No. of SF Dwelling Units X $ NIA = $ NIA NIA (date) Approved by Parks & Recreation Advisory Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct, and complete. IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER OF THE PROPERTY, this application must be accompanied by a power of attorney statement from the owner. If there is more than one owner, an owners must sign the application or the power of attorney. ff the owner is a company, the application must be accompanied by proof of authority for the company's representative to sign the application on its behalf. LIEN HOLDERS identified in the title report are also considered owners and the appropriate signatures must be provided as described above. i«~Awer Signature and title Date r I Revised 4114 Page4 of9 CERTIFICATIONS REQUIRED FOR ALL DEVELOPMENT Owner Certification: 1. No work of any kind may start until a permit is issued. 2. The permit may be revoked if any false statements are made herein. 3. If revoked, all work must cease until permit is re-issued. 4. Development shall not be used or occupied until a Certificate of Occupancy is issued. 5. The permit will expire if no significant work is progressing within 24 months of issuance. 6. Other permits may be required to fulfill local, state, and federal requirements. Owner will obtain or show compliance with all necessary State and Federal Permits prior to construction including NOi and SWPPP. 7. If required, Elevation Certificates will be provided with elevations certified during construction (forms at slab pre- pour) and post construction. 8. Owner hereby gives consent to City representatives to make reasonable inspections required to verify compliance. 9. If, stormwater mitigation is required, including detention ponds proposed as part of this project, it shall be designed and constructed first in the construction sequence of the project. 10. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that all debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. 11 . The information and conclusions contained in the attached plans and supporting documents will comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified Design Guidelines Technical Specifications, and Standard Details. All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 12. Release of plans to (name or firm) is authorized for bidding purposes only. I understand that final approval and release of plans and development for construction is contingent on contractor signature on approved Development Permit. 13. I, THE OWNER, AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS FOR THE DEVELOPMENT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE, AND ACC~tkwtd Property Owner(s) Date Engineer Certification: 1. The project has been designed to ensure that stormwater mitigation, including detention ponds, proposed as part of the project will be constructed first in the construction sequence. 2. I will obtain or can show compliance with all necessary Local, State and Federal Permits prior to construction including NOi and SWPPP. Design will not preclude compliance with TPDES: i.e., projects over 10 acres may require a sedimentation basin. 3. The information and conclusions contained in the attached plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified Design Guidelines. Alf development has been designed in accordance with all applfcable codes and ordinances the City of College Station and State and F Regulations. HE ENGINEER, AGREE TO AND C ~~~STATEMENTS HEREIN, AND IN ATTACHMENTS R THE DEVELOPMENT PERMIT _, .·· *' 0N1·~l'f,O THE BEST OF MY KNOWLEDGE, TRUE, AND CURATE. ~* ,/ \ ... ~ 1 * : .............. ~ ~ \ ~ ~veRoNi~~X~:'.~.Q~~~·~ v\ \\9\ \~ --l-~~~~~l..h~;:::::=-~~1.~~~~~~77689 .~!w-..;~~~~~,__..__~~~~~~ ~, ~·· .... -9~ '?-~?.···~! Revised 4/14 Page 5 of9 The following CERTIFICATIONS apply to development in Special Flood Hazard Areas. Required for Site Plans, Final Plats, Construction Plans, Fill/ Grading Permits, and Clearing Only Permits:* A. I, certify, as demonstrated in the attached drainage study, that the evelopment covered by this permit, shall not: (i) increase th Base Flood elevation; (ii) create additio al areas of Special Flood Hazard Area; (iii) decrease the co veyance capacity to that part of the Special Flood Hazard Area that is not in the floodway and where the ve city of flow in the Base Flood event is greater than one foot per second. Th is area can also be approxima d to be either areas within 100 feet of the boundary of the regulatory floodway or areas where the de h of from the BFE to natural ground is 18 inches or greater; (iv) water storage volume to the part of the Special Flood Hazard Area that is beyond (v) the floodway and conv ance area where the velocity of flow in the Base Flood is equal to and less than one foot per second with ut acceptable compensation as set forth in the City of College Station Code of Ordinances, Chapter 13 c ncerning encroachment into the Special Flood Hazard Area; nor beyond those areas exempted by dinance in Section 5.11 .3a of Chapter 13 Code of Ordinances. Initial D * If a platting-status exemption to this equirement is asserted, provide written justification under separate letter in lieu of certification. Required for Site Plans, Final Plats, Constructio Plans, and Fill/ Grading Permits: B. I, ~~~~~~~~~~~~~~~~ (i) that any nonresidential or multi-family structure on o proposed to be on this site as part of this application is designed to prevent damage to the structure or its con nts as a result of flooding from the 100-year storm. \ Engineer Dae \ Additional certification for Floodway Encroachments: C. I, , certify that the const uction, improvement, or fill covered by this ~~~~~~~~~~~~~~~~· permit shall not increase the base flood elevation. I will apply for a variance to the Zoning Board of Adjustments. Engineer Date Revised 4/14 Page 6 of 9 Required for all projects proposing structures in Special Flood Hazard Area (Elevation Certificate required). Residential Structures: D. I, , certify that all new construction or any substantial improvement of any residential structure sli II have the lowest floor, including all utilities, ductwork and any basement, at an elevation at least one foot abo the Base Flood Elevation. Required Elevation Certificates will be provided with elevations certified during constr ction (forms at slab pre-pour) and post construction . Engineer I Surveyor Date Commercial Structures: ~IA E. I, _______________ _.... , certify that all new construction or any substantial improvement of any commercial, industrial, or other non-resi ential structure are designed to have the lowest floor, including all utilities, ductwork and basements, elevated at le st one foot above the Base Flood Elevation Engineer I Surveyor Date I, , certify hat the structure with its attendant utility, ductwork, basement and sanitary facilities is designed to be flood-proo d so that the structure and utilities, ductwork, basement and sanitary facilities are designed to be watertight nd impermeable to the intrusion of water in all areas below the Base Flood Elevation, and shall resist the stru ural loads and buoyancy effects from the hydrostatic and hydrodynamic conditions. Requi red Elevation Certificates will be provided with elevations ce ·tied during construction (forms at slab pre- pour) and post construction. Engineer I Surveyor Date Conditions or comments as part of approval: Revised 4/14 Page 7 of 9 FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) [8] Drawn on 24" x 36" sheet to scale of 100' per inch. [8] Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. [8] Title Block with the following information: [8] Name and address of subdivider, recorded owner, planner, engineer and surveyor. [8] Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911 .) [8J Date of preparation. [8J Engineer's scale in feet. [8J Total area intended to be developed. North Arrow. Subdivision boundary indicated by heavy lines. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. [8J All applicable certifications based on the type of final plat. [8] Ownership and Dedication [8] Surveyor and/or Engineer [8J City Engineer (and City Planner, if a minor plat) [8] Planning and Zoning Commission (delete if minor plat) [8J Brazos County Clerk >{[h Brazos County Commissioners Court Approval (ET J Plats only) tf/br If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. tfpr If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21 .084 of the Texas Water Code. [8J Location of the 100-Year Floodplain and floodway, if applicable, according to the most recent available data. [8J Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. [8] Matches the approved preliminary plan or qualifies as minor amendments (UDO Section 3.3.E.2). The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision , as well as, those within the subdivision). Existing Proposed [8J Revised 4/14 l8J Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) Street offsets and/or intersection angles meet ordinance. Page 8 of 9 Existing ~ [8] [8] ~ Proposed ~ Alleys. Easements. [8] [8] A number or letter to identify each lot or site and each block (numbered sequentially). ~ Parkland dedication/greenbelt area/park linkages. All proposed dedications must be reviewed by the Parks and Recreation Advisory Board and documentation of their recommendation provided prior to being scheduled for P&Z Commission consideration. [8] Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). . . Sewer Design Report. [ w i l l S Llb(rLt t LO i-t\r) S \ t-e plM) Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Water Design Report and/or Fire Flow Report. { w \ ll st<l::Jrni r VO 1-tJ0 s ik p L CLh) Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. [8] Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. [8] Letter of completion for public infrastructure or guarantee I surety in accordance with UDO Section 8.6. [8] Drainage Report with a Technical Design Summary. [8] Erosion Control Plan (must be included in construction plans). [8] All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed . Separate instrument easements must be provided in recordable form to the City prior to being scheduled for P&Z Commission consideration. [8] Are there impact fees associated with this development? D Yes [8] No Impact fees must be paid prior to building permit. [8] Will any construction occur in TxDOT rights-of-way? D Yes [8] No If yes, TxDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOi) must be submitted prior to issuance of a development permit. . Prin} Form · I Revised 4/14 Page 9 of 9