Loading...
HomeMy WebLinkAboutAppendix 17 Proposed HEC-RAS ModelAppendix 17 Proposed HEC-RAS Model HEC-RAS September 1998 Version 2.2 U.S. Army Corp of Engineers Hydrologic Engineering Center 609 Second Street, Suite D Davis, Cal ifornia 95616-4687 (916) 756-1104 x x xxxxxx xx xx xxxx xx x x x x x x x x x x x x x x x x x xxxxxxx xx xx x xxx xxxx xxxxxx x x x x x x x x x x x xxxxxx xx xx PROJECT DATA Project Titl e: Lick Creek June 2000 Final Project File LC2000f .prj Run Date and Time: 6/20/00 1:13:02 PM Project in English units Project Description: Finalized Lick Creek Watershed Flood Insurance Re-Study June 2000 by City of College Station, Brazos County, Texas to replace BRAZOS COUNTY LIMITED DETAILED STUDY SEPT 89 100 YEAR FREQUENCY FLOOD LICK CREEK PLAN DATA Plan Title: Final Plan x x x x x x x x x x x x xx xx x x xxxx x x xxxxx Plan File o:\GROUP\DEVE_SER\Jeff\Lick2000\toCD\Hydraulics\HEC-RAS Proposed Model\LC2000f.p01 Geometry Title: Finalized Lick 2000 Study Geometry File : o:\GROUP\DEVE_SER\Jeff\Lick2000\toCD\Hydraulics\HEC-RAS Proposed Model\LC2000f.g01 Flow Title Flow File Model\LC2000f.f01 Finalized Lick Creek 2000 Flows o:\GROUP\DEVE_SER\Jeff\Lick2000\toCD\Hydraulics\HEC-RAS Proposed Plan Summary Information: Number of: Cross Sections Culverts Bridges Computational Information 185 7 1 Mulitple Openings Inline Weirs Water surface calculation tolerance 0.01 Critical depth calculaton tolerance 0.01 Maximum number of interations 20 0 0 Maximum difference tolerance Flow tolerance factor Computation Options 0.3 0.001 Critical depth computed only where necessary Conveyance Calculation Method: At breaks in n values only Friction Slope Method: Average Conveyance Computational Flow Regime: Subcritical Flow FLOW DATA Flow Title: Finalized Lick Creek 2000 Flows Flow File o:\GROUP\DEVE_SER\Jeff\Lick2000\toCD\Hydraulics\HEC-RAS Proposed Model\LC2000f .f01 Flow Data (cfs) River Reach RS PF 1 N.F. Lick Creek N.F . Main 68770 1980 N.F. Lick Creek N.F. Main 66550 1980 N.F. Lick Creek N.F. Main 63920 2301 S.F. LICK CREEK AlexBranch 8867. 292 S.F. LICK CREEK west field 11228. 1352 S.F. LICK CREEK S.F. Main 7993. 1352 S.F. LICK CREEK S.F. Main 6698. 2025 S.F. LICK CREEK S.F. Main 2210. 2297 Lick Creek Main Fema X-sect 58600 4905 Lick Creek Main Fema x-sect 51198 5324 Lick Creek Main Fema X-sect 43850 9161 Lick Creek Main Fema X-sect 29910 12741 Lick Creek Main Fema X-sect 20790 12730 Boundary Conditions River Reach Profile Upstream Downstream Lick Creek Main Fema X-sect PF 1 205 GEOMETRY DATA Geometry Title: Finalized Lick 2000 Study Geometry File : o:\GROUP\DEVE_SER\Jeff\Lick2000\toCD\Hydraulics\HEC-RAS Proposed Model\LC2000f .g01 Reach Connection Table River Reach N.F. Lick Creek N.F. Main S.F. LICK CREEK AlexBranch S.F. LICK CREEK westf ield S.F. LICK CREEK S.F. Main Lick Creek Main Fema x-sect JUNCTION INFORMATION Name: fork Description: Energy computation Method Length across Junction River Reach Upstream Boundary PTl fork Tributary River Downstream Boundary Reach fork PTl PTl fork Length Angle Known WS N.F. Lick Creek N.F. Main S.F. LICK CREEK S.F. Main Name: PTl Description: Energy computation Method Length across Junction River Reach S.F. LICK CREEK AlexBranch S .F. LICK CREEK westfield to Lick Creek Main Fema X-sect to Lick Creek Main Fema X-sect Tributary River Reach to S.F. LICK CREEK S.F. Main to S.F. LICK CREEK S .F. Main CROSS SECTION RIVER : N.F. Lick Creek REACH: N.F. Main RS: 68770 INPUT Descri ption: Station Elevation Data num= 13 Sta Elev Sta Elev Sta Elev Sta Elev 1000 298 1007 296 1010 294 1085 294 1096 290 1105 288.8 1180 290 1230 292 1390 294 1520 296 1660 298 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1096 .055 1180 .075 1300 1280 Length 361 284 Sta 1092 1350 Angle Elev 292 292 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1096 1180 160 360 400 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G . Elev (ft) 294 .75 Element Left OB Channel Vel Head (ft) 0.08 Wt. n-Val. 0.075 0.055 w.s . Elev (ft) 294 .66 Reach Len. (ft) 160.00 360.00 Crit W.S. (ft) Flow Area (sq ft) 76.32 442.07 E.G. Slope (ft/ft) 0.001179 Area (sq ft) 76.32 442 .07 Q Total (cfs) 1980.00 Flow (cfs) 47.25 1240.12 Top Width (ft) 424 .07 Top Width (ft) 86 .99 84.00 Vel Total (ft/s) 1.80 Avg. Vel. (ft/s) 0.62 2.81 Max Chl Dpth (ft) 5.86 Hydr. Depth (ft) 0.88 5.26 Conv. Total (cfs) 57653.l Conv. (cfs) 1375.8 36109.6 Length Wtd. (ft) 344.70 Wetted Per. (ft) 87 .95 84.09 Min Ch El (ft) 288.80 Shear (lb/sq ft) 0 .06 0.39 Alpha 1.68 Stream Power (lb/ft s ) 0.04 1. 09 Frctn Loss (ft) 0. 45 Cum Volume (acre-ft) 95 .51 53 .11 C & E Loss (ft) 0.00 Cum SA (acres) 36.18 7 .05 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 68410 INPUT Description: Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 990 298 1000 296 1015 294 1090 292 1170 290 1240 288.5 1258 290 1305 292 1340 294 1440 296 1530 298 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 990 .075 1170 .055 1258 .075 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 1170 1258 210 385 235 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 294.30 Element Left OB Channel Vel Head (ft) 0 .10 Wt. n-Val. 0.075 0.055 Right OB 0.075 400.00 583 .45 583 .45 692.63 253.08 1.19 2 .31 20167.7 253.17 0.17 0.20 107.42 37.57 Right OB 0.075 w.s. Elev (ft) 294.20 Reach Len. (ft) 210.00 385.00 235.00 Cr it w.s. (ft) Flow Area (sq ft) 345.65 435.32 193.11 E.G. Slope (ft/ft) 0.001449 Area (sq ft) 345.65 435.32 193 .11 Q Total (cfs) 1980.00 Flow (cfs) 442.06 1299.08 238.87 Top Width (ft) 336.32 Top Width (ft) 156.48 88.00 91.84 Vel Total (ft/s) 2.03 Avg. Vel. (ft/s) 1.28 2.98 1.24 Max Chl Dpth (ft) 5.70 Hydr. Depth (ft) 2 .21 4.95 2.10 Conv. Total (cfs) 52011.1 Conv. (cfs) 11612. 1 34124.4 6274 .6 Length Wtd. (ft) 318.35 Wetted Per. (ft) 156.54 88 .08 91.94 Min Ch El (ft) 288.50 Shear (lb/sq ft) 0.20 0.45 0.19 Alpha 1.55 Stream Power (lb/ft s) 0.26 1. 33 0.24 Fr ctn Loss (ft) 0.54 Cum Volume (acre-ft) 94.73 49. 49 103.85 C & E Loss (ft) 0.01 Cum SA (acres) 35.73 6.34 35.99 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 68025 INPUT Description: Station Elevation Data num= 13 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 700 298 820 296 1000 294 1055 292 1100 290 1135 288 1165 287 1178 288 1190 290 1260 292 1365 294 1480 296 1660 298 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 700 .075 1135 .055 1178 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1135 1178 220 345 240 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 293.75 Element Left OB Channel Right OB Vel Head (ft) 0.15 Wt. n-Val. 0 .075 0.055 0.075 w.s. Elev (ft) 293.60 Reach Len. (ft) 220.00 345.00 240.00 Crit W.S. (ft) Flow Area (sq ft) 312.83 262.17 303.90 E.G. Slope (ft/ft) 0.002015 Area (sq ft) 312.83 262.17 303.90 Q Total (cfs) 1980.00 Flow (cfs) 515.44 1060.19 404.38 Top Width (ft) 332.76 Top Width (ft) 123.92 43.00 165.84 Vel Total (ft/s) 2.25 Avg. Vel. (ft/s) 1. 65 4.04 1.33 Max Chl Dpth (ft) 6.60 Hydr. Depth (ft) 2.52 6.10 1.83 Conv. Total (cfs) 44110. 0 Conv. (cfs) 11482. 8 23618.7 9008.6 Length Wtd. (ft) 278.51 Wetted Per. (ft) 124.05 43.06 166.05 Min Ch El (ft) 287 .00 Shear (lb/sq ft) 0.32 0 .77 0 .23 Alpha 1.94 Stream Power (lb/ft s) 0.52 3.10 0.31 Frctn Loss (ft) 0.61 Cum Volume (acre-ft) 93.15 46.40 102.51 C & E Loss (ft) 0.00 Cum SA (acres) 35.06 5.76 35.29 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 67680 INPUT Description: Station Elevation Data num= 16 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 735 298 865 296 940 294 1000 292.6 1070 292 1095 290 1118 288 1130 286 1135 285 1145 286 1170 288 1222 290 1295 292 1330 294 1380 296 1730 298 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 735 .075 1130 .055 1145 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1130 1145 230 380 300 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 293. 14 Element Left OB Channel Right OB Vel Head (ft) 0.15 Wt. n-Val. 0.075 0.055 0.075 w.s. Elev (ft) 292.99 Reach Len . (ft) 230.00 380.00 300.00 Crit W.S. (ft) Flow Area (sq ft) 265.00 112.35 511.12 E.G. Slope (ft/ft) 0 .002376 Area (sq ft) 265.00 112.35 511. 12 Q Total (cfs) 1980.00 Flow (cfs) 378.94 562.68 1038.38 Top Width (ft) 329.06 Top Width (ft) 146.73 15.00 167.33 Vel Total (ft/s) 2.23 Avg. Vel. (ft/s) 1. 43 5.01 2.03 Max Chl Dpth (ft) 7.99 Hydr. Depth (ft) 1. 81 7.49 3.05 Conv. Total (cfs) 40622.2 Conv. (cfs) 7774.4 11544.l 21303 .8 Length Wtd. (ft) 304.11 Wetted Per. (ft) 147.06 15.15 167.50 Min Ch El (ft) 285.00 Shear (lb/sq ft) 0.27 1.10 0.45 Alpha 1.95 Stream Power (lb/ft s) 0.38 5.51 0.92 Frctn Loss (ft) 0. 71 Cum Volume (acre-ft) 91.69 44.92 100.27 C & E Loss (ft) 0.00 Cum SA (acres) 34.37 5.53 34.37 CROSS SECTI ON RIVER: N.F. Lick Creek REACH: N.F. Main RS: 67300 INPUT Description: Station Elevation Data num= 18 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 815 298 875 296 920 294 1000 292 1078 290 1110 288 1140 286 1150 284 1155 283.8 1165 284 1170 286 1180 288 1220 290 1280 292 1295 294 1705 294 1875 296 1955 298 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 815 .075 1150 .055 1165 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1150 1165 315 225 65 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E .G. Elev (ft) 292.42 Element Left OB Channel Right OB Vel Head (ft) 0.18 Wt. n-Val. 0.075 0.055 0 .075 w.s. Elev (ft) 292.24 Reach Len. (ft) 315.00 225.00 65.00 Crit W.S. (ft) Flow Area (sq ft ) 430.91 125.08 292.64 E.G. Slope (ft/ft) 0.002323 Area (sq ft) 430.91 125.08 292.64 Q Total (cfs) 1980.00 Flow (cfs) 796.89 669.57 513.54 Top Width (ft) 291.33 Top Width (ft) 159.54 15.00 116. 79 Vel Total (ft/s) 2.33 Avg. Vel. (ft/s) 1. 85 5.35 1.75 Max Chl Dpth (ft) 8.44 Hydr. Depth (ft) 2.70 8 .34 2.51 Conv. Total (cfs) 41079 .5 Conv. (cfs) 16533.2 13891.7 10654.6 Length Wtd. (ft) 187.45 Wetted Per. (ft) 159.90 15.01 117.47 Min Ch El (ft) 283.80 Shear (lb/sq ft ) 0.39 1. 21 0.36 Alpha 2.18 Stream Power (lb/ft s) 0. 72 6.47 0.63 Frctn Loss (ft) 0.28 Cum Volume (acre-ft) 89 .85 43.89 97 .50 C & E Loss (ft) 0.03 Cum SA (acres) 33.56 5.40 33 .39 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is l ess than 0.7 or greater than 1 .4. This may indicate the need for additional cross sections. CROSS SECTI ON RIVER: N.F. Lick Creek REACH: N.F. Main RS: 67075 INPUT Description: Station El evation Data num= 15 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 590 298 700 296 1000 292 1400 291 .5 1450 290 1520 288 1545 287 1558 282.5 1570 285.5 1610 287 1775 291 1800 292 2200 294 2400 296 2500 298 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 590 .075 1545 .055 1570 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1545 1570 15 15 15 .3 . 5 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 292.10 Element Left OB Channel Right OB Vel Head (ft) 0.07 Wt. n-Val. 0.075 0.055 0.075 w.s. Elev (ft) 292. 03 Reach Len. (ft) 15.00 15.00 15.00 Crit W.S. (ft) Flow Area (sq ft) 502.87 191.07 745.13 E.G. Slope (ft/ft) 0.001068 Area (sq ft) 502.87 191.07 745.13 Q Total (cfs) 1980.00 Flow (cfs) 307.69 635.70 1036.62 Top Width (ft) 809.00 Top Width (ft) 547.45 25.00 236.54 Vel Total (ft/s) 1. 38 Avg. Vel. (ft/s) 0.61 3.33 1.39 Max Chl Dpth (ft) 9.53 Hydr. Depth (ft) 0.92 7.64 3.15 Conv. Total (cfs) 60577.5 Conv. (cfs) 9413.6 19448.9 31714.9 Length Wtd. (ft) 15.00 Wetted Per. (ft) 547.53 26.13 236.64 Min Ch El (ft) 282 .50 Shear (lb/sq ft) 0.06 0.49 0.21 Alpha 2.44 Stream Power (lb/ft s) 0.04 1.62 0.29 Frctn Loss (ft) 0.02 Cum Volume (acre-ft) 86.47 43.07 96.73 C & E Loss (ft) 0.00 Cum SA (acres) 31.01 5.30 33 .13 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 67060 INPUT Description: Station Elevation Data num= 16 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 590 298 700 296 1000 292 1400 291.5 1450 290 1520 288 1545 287 1558 282.5 1565 282 .5 1570 285.5 1610 287 1775 291 1800 292 2200 294 2400 296 2500 298 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 590 .075 1545 .055 1570 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1545 1570 10 10 10 . 3 . 5 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 292.09 Element Left OB Channel Right OB Vel Head (ft) 0.07 Wt. n-Val. 0.075 0.055 0.075 w.s. Elev (ft) 292.01 Reach Len. (ft) 10.00 10.00 10.00 Crit W.S. (ft) Flow Area (sq ft) 492.67 201.10 740.76 E.G. Slope (ft/ft) 0.001027 Area (sq ft) 492.67 201.10 740.76 Q Total (cfs) 1980.00 Flow (cfs) 292.04 670.86 1017.10 Top Width (ft) 803.87 Top Width (ft) 546.06 25.00 232.81 Vel Total (ft/s) 1.38 Avg . Vel. (ft/s) 0.59 3.34 1. 37 Max Chl Dpth (ft) 9.51 Hydr. Depth (ft) 0.90 8.04 3.18 Conv. Total (cfs) 61787.6 Conv. (cfs) 9113. 2 20934.9 31739.5 Length Wtd. (ft) 10.00 Wetted Per. (ft) 546.13 26.59 232.91 Min Ch El (ft) 282.50 Shear (lb/sq ft) 0.06 0.48 0.20 Alpha 2.51 Stream Power (lb/ft s) 0.03 1.62 0.28 Frctn Loss (ft) 0.01 Cum Volume (acre-ft) 86.30 43.00 96.47 C & E Loss (ft) 0.01 Cum SA (acres) 30.82 5.29 33.05 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: N.F. Main INPUT RIVER: N.F. Lick Creek RS: 67050 Description: Station Elevation Data num= 14 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 1000 292 1400 291 1450 290 1520 288 1545 287 1558 282 .5 1575 280.7 1590 280.7 1600 285 1775 291 1800 292 2120 292.9 2300 294 2400 296 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1545 .055 1600 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1545 1600 70 70 70 .3 . 5 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1574 290.2 1586 2400 290.2 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 292.07 El ement Left OB Channel Right OB Vel Head (ft) 0.05 Wt. n-Val. 0.075 0.055 0.075 w.s. Elev (ft) 292.02 Reach Len. (ft) 70.00 70.00 70.00 Crit W.S. (ft) 290.20 Flow Area (sq ft) 609.94 533.31 717.16 E.G. Slope (ft/ft) 0.000326 Area (sq ft) 609.94 533.31 717.16 Q Total (cfs) 1980.00 Flow (cfs) 235 .30 1159. 32 585.38 Top Width (ft) 808.12 Top Width (ft) 545.00 55 .00 208 .12 Vel Total (ft/s) 1.06 Avg. Vel. (ft/s) 0.39 2.17 0.82 Max Chl Dpth (ft) 11.32 Hydr. Depth (ft) 1.12 9.70 3.45 Conv. Total (cfs) 109599.9 Conv. (cfs) 13024.8 64172.2 32402.9 Length Wtd. (ft) 70 .00 Wetted Per. (ft) 545.08 56.74 208.24 Min Ch El (ft) 280.70 Shear (lb/sq ft) 0.02 0.19 0.07 Alpha 2 .63 Stream Power (lb/ft s) 0.01 0.42 0.06 Frctn Loss (ft) Cum Volume (acre-ft) 86 .18 42.92 96.30 C & E Loss (ft) Cum SA (acres) 30.69 5.28 33.00 Warning: The parabolic search method failed to converge on critical depth. The program will try the cross section slice/secant method to find critical depth. CULVERT REACH: N.F. Main RIVER : N.F. Lick Creek RS : 67049 INPUT Description: Distance from Upstream XS Deck/Roadway Width Weir Coefficient Bridge Deck/Roadway Skew 10 50 2.6 Upstream Deck/Roadway Coordinates num= 10 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 1050 298 1400 1870 291.7 292 2400 296 1080 296 1550 2120 290.2 292.9 Upstream Bridge Cross Section Data Station Elevation Data num= 14 Sta Elev Sta Elev Sta 1000 292 1400 291 1450 1558 282.5 1575 280.7 1590 1800 292 2120 292 .9 2300 Manning's n Values num= 3 Sta n Val Sta n Val Sta 1000 .075 1545 .055 1600 Bank Sta: Left Right Coef f Contr. 1545 1600 .3 Ineffective Flow num= 2 Elev 290 280.7 294 n Val .075 Expan. .5 Sta Hi Cord Lo Cord 1220 294 1700 2300 Sta 1520 1600 2400 290.6 294 Elev 288 285 296 Sta 1545 1775 Elev 287 291 Sta L Sta R Elev Sta L Sta R Elev 1000 1574 290.2 1586 2400 290.2 Downstream Deck/Roadway Coordinates num= 10 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 1050 298 1080 296 1220 294 1400 291.7 1550 290.2 1700 290.6 1870 292 2120 292.9 2300 294 2400 296 Downstream Bridge Cross Section Data Station Elevation Data num= 15 Sta Elev Sta Elev Sta Elev Sta Elev Sta 1000 292 1400 290 1450 290 1520 288 1535 1539 280.34 1551 280.34 1555 282 .5 1570 285.5 1610 1775 291 1800 292 2120 292.9 2300 294 2400 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1535 .055 1570 .075 Bank Sta: Left Right Coeff Contr. Expan. 1535 1570 .3 .5 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1539 290.2 1551 2400 290.2 Upstream Embankment side slope Downstream Embankment side slope Maximum allowable submergence for weir flow Elevation at which weir flow begins 0 horiz. to 1.0 vertical 0 horiz. to 1.0 vertical .95 Energy head used in spillway design Spillway height used in design 291.l Weir crest shape Broad Crested Number of Culverts 1 Culvert Name Shape Rise USC Driveway Box 6 FHWA Chart # 8 -flared wingwalls Span 12 FHWA Scale # 1 -Wingwall flared 30 to 75 deg. Solution Criteria = Highest U.S. EG Culvert Upstrm Dist Length n Value 1 71 .014 Entrance Loss Coef .6 Exit Loss Coef 1 Upstream Elevation 280.7 Centerline Station Downstream Elevation = 280.34 Centerline Station CULVERT OUTPUT Profile #PF 1 Culvert ID : USC Driveway Culv Q (cfs) 404 .77 # Barrels 1 Q Barrel (cfs) 404.77 E.G. us. (ft) 292.07 w.s. us. (ft) 292.02 Delta EG (ft) 0 .77 Delta ws (ft) 0.82 E.G. IC (ft) 291.70 E.G. oc (ft) 292.07 Culvert Control Outlet Culv WS In (ft) 286.70 Culv ws Out (ft ) 286 .34 Culv Nml Depth (ft ) Culv Crt Depth (ft) 3 .28 Culv Ful Lngh (ft) 71.00 1580.9 1545.l Culv Vel In (ft/s) Culv Vel Out (ft/s ) Culv Inv El Up (ft) Culv Inv El Dn (ft) Culv Frctn Ls (ft) Culv Ext Lss (ft) Culv Ent Lss (ft) Q Weir (cfs) Weir Sta Lft (ft) Weir Sta Rgt (ft) Weir Submerg Weir Max Depth (ft) Weir Avg Depth (ft) Wr Flw Area (sq ft) Min Top Rd (ft) CROSS SECTION RIVER: N.F. Lick Creek 5.62 5 .62 280.70 280.34 0.08 0.39 0.29 1575.23 1000 .00 1822.73 0.36 1.86 1. 06 528.89 291.10 Elev 287 287 296 REACH: N.F. Main INPUT Description: Station Elevation Data Sta Elev Sta 1000 292 1400 1539 280.34 1551 1775 291 1800 Manning's n Values Sta n Val 1000 .075 Bank Sta: Left 1535 Ineffective Flow Sta L Sta R 1000 1539 Sta 1535 Right 1570 num= Elev 290.2 RS: 66980 num= 15 Elev Sta Elev 290 1450 290 280.34 1555 282.5 292 2120 292.9 num= 3 n Val Sta n Val .055 1570 .075 Lengths: Left Channel Sta L 1551 2 10 10 Sta R 2400 Elev 290.2 Sta 1520 1570 2300 Right 10 El ev Sta 288 1535 285.5 1610 294 2400 Coeff Contr . . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft ) C & E Loss (ft ) 291.30 0.10 291.21 289.60 0 .000991 1980.00 621.15 1. 54 10.87 62892.1 10.00 280.34 2.67 0.01 0.01 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv . (cfs) Wetted Per. (ft) Shear (lb/ sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.075 10.00 415.42 415 .42 276.88 376.02 0 .67 1 .10 8794.6 376 .09 0.07 0 .05 85.35 29.95 Elev 287 287 296 Expan . .5 Channel 0.055 10.00 307.74 307.74 1026.73 35.00 3.34 8 .79 32612 .6 39.61 0.48 1.60 42.24 5.21 Right OB 0.075 10.00 562.57 562.57 676.40 210 .13 1. 20 2 .68 21484.8 210.21 0.17 0.20 95.27 32.66 Warning: Multiple water surfaces were found that could balance the energy equation. The program selected the water surface whose main channel velocity head was the closest to the previously computed cross section. CROSS SECTION REACH: N.F. Main RIVER: N.F. Lick Creek RS: 66970 INPUT Description: Station Elevation Data Sta Elev Sta 1000 292 1400 1558 282.5 1570 Manning's n Values Sta n Val Sta 1000 .075 1545 Bank Sta: Left 1545 Right 1570 CROSS SECTION OUTPUT E.G . Elev (ft) Vel Head (ft) W.S . Elev (ft) Crit W.S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s ) Max Chl Dpth (ft) num= 10 Elev Sta Elev Sta 291. 5 1450 290 1520 285.5 1610 287 1775 num= 3 n Val Sta n Val .055 1570 .075 Lengths: Left Channel Right 40 Profile #PF 1 291 .28 0.12 291.17 0 .001912 1980.00 368.06 2.00 8.67 20 70 Element Wt . n-Val. Reach Len. (ft ) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s ) Hydr. Depth (ft) Elev Sta 288 1545 291 1800 Coeff Contr. .3 Left OB 0.075 20.00 266.04 266.04 364 .11 133 .89 1. 37 1. 99 Elev 287 292 Expan. . 5 Channel 0.055 70.00 169.42 169.42 695.94 25.00 4.11 6 .78 Right OB 0 .075 40.00 554.54 554.54 919.95 209 .17 1.66 2.65 Conv. Total (cfs) 45284.7 Conv. (cfs) 8327.7 15916.9 21040.2 Length Wtd. (ft) 46.93 Wetted Per. (ft) 133.96 26.13 209.25 Min Ch El (ft) 282.50 Shear (lb/sq ft) 0.24 0.77 0.32 Alpha 1.89 Stream Power (lb/ft s) 0.32 3 .18 0 .52 Frctn Loss (ft) 0 .11 Cum Volume (acre-ft) 85.27 42.19 95.15 C & E Loss (ft) 0.02 Cum SA (acres) 29.90 5.20 32.61 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 66940 INPUT Description: new city topo x-section added by jst Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 292 1018 290 1020 288 1025 286 1030 284 1040 283 1043 284 1050 286 1130 288 1280 290 1355 292 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1030 .055 1043 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1030 1043 100 90 25 . 3 . 5 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 291.16 Element Left OB Channel Right OB Vel Head (ft) 0.17 Wt. n-Val. 0 .075 0 .055 0.075 w.s. Elev (ft) 290.99 Reach Len. (ft ) 100.00 90.00 25.00 Crit W.S. (ft) Flow Area (sq ft) 58.20 97 .31 676.77 E.G. Slope (ft/ft) 0.002926 Area (sq ft) 58 .20 97 .31 676.77 Q Total (cfs) 1980.00 Flow (cfs) 117. 43 538.31 1324. 26 Top Width (ft) 307.82 Top Width (ft) 20 .87 13.00 273.96 Vel Total (ft/s) 2 .38 Avg. Vel. (ft/s) 2 .02 5.53 1.96 Max Chl Dpth (ft) 7 .99 Hydr. Depth (ft) 2.79 7.49 2.47 Conv. Total (cfs) 36606 .2 Conv. (cfs) 2171. l 9952 .2 24482.8 Length Wtd. (ft ) 51.41 Wetted Per. (ft) 22.52 13.21 274.29 Min Ch El (ft) 283.00 Shear (lb/sq ft) 0 .47 1.35 0.45 Alpha 1.97 Stream Power (lb/ft s) 0.95 7 .44 0.88 Frctn Loss (ft) 0.15 Cum Volume (acre-ft ) 85.20 41 .97 94.58 C & E Loss (ft) 0.01 Cum SA (acres) 29.86 5.17 32.39 CROSS SECTION RIVER: N.F. Lick Creek REACH : N.F. Main RS: 66850 INPUT Description: topo x-section added by jst Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 960 291 1000 290 1035 288 1050 286 1055 284 1065 282.5 1070 284 1078 286 1150 288 1280 290 1355 292 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 960 .075 1055 .055 1070 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan . 1055 1070 150 300 300 .l .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 291. 00 Element Left OB Channel Right OB Vel Head (ft) 0.19 Wt. n-Val. 0.075 0.055 0.075 w.s. Elev (ft) 290.81 Reach Len. (ft) 150 .00 300.00 300.00 Crit W.S. (ft) Flow Area (sq ft) 162.86 113 .43 568.91 E.G. Slope (ft/ft) 0.002944 Area (sq ft) 162.86 113.43 568.91 Q Total (cfs) 1980.00 Flow (cfs) 263.74 631.31 1084.95 Top Width (ft) 342.94 Top Width (ft) 87.48 15.00 240.45 Vel Total (ft/s) 2.34 Avg. Vel . (ft/s) 1.62 5.57 1 .91 Max Chl Dpth (ft) 8.31 Hydr. Depth (ft) 1. 86 7.56 2.37 Conv. Total (cfs) 36493.1 Conv. (cfs) 4861.0 11635. 6 19996.5 Length Wtd. (ft) 288.82 Wetted Per. (ft) 88.07 15.33 240.75 Min Ch El (ft) 282.50 Shear (lb/sq ft) 0.34 1.36 0.43 Alpha 2.23 Stream Power (lb/ft s) 0.55 7 .57 0.83 Frctn Loss (ft) 0.77 Cum Volume (acre-ft) 84.95 41.75 94.22 C & E Loss (ft) 0.00 Cum SA (acres) 29.74 5.14 32.25 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 66550 INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 292 1030 290 1220 290 1260 288 1270 286 1310 284 1320 282.5 1330 284 1340 286 1400 288 1420 290 1520 292 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1270 .055 1340 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan . 1270 1340 280 250 220 .1 .3 CROSS SECTION OUTPUT Profil e #PF 1 E.G. Elev (ft) 290.23 Element Left OB Channel Right OB Vel Head (ft) 0.22 Wt. n-Val. 0.075 0.055 0.075 w.s. Elev (ft) 290.01 Reach Le n. (ft) 280 .00 250.00 220.00 Crit W.S. (ft) Flow Area (sq ft) 72.24 385.65 200.75 E .G. Slope (ft/ft) 0. 002413 Area (sq ft) 72.24 385 .65 200.75 Q Total (cfs) 1980.00 Flow (cfs) 31.55 1589.45 359.00 Top Width (ft) 390.61 Top Width (ft) 240.14 70.00 80.47 Vel Total (ft/s) 3.01 Avg. Vel. (ft/s) 0.44 4.12 1.79 Max Chl Dpth (ft) 7.51 Hydr. Depth (ft) 0 .30 5.51 2.49 Conv. Total (cfs) 40305.9 Conv. (cfs) 642.2 32355.8 7308.0 Length Wtd. (ft) 248.85 Wetted Per. (ft) 240.39 70 .47 80.60 Min Ch El (ft) 282.50 Shear (lb/sq ft) 0.05 0 .82 0.38 Alpha 1.57 Stream Power (lb/ft s) 0.02 3.40 0.67 Frctn Loss (ft) 0.63 Cum Volume (acre-ft) 84.54 40 .04 91 .57 C & E Loss (ft) 0.01 Cum SA (acres) 29.17 4 .85 31.14 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 66300 INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 292 1040 290 1150 290 1200 288 1280 286 1310 284 1315 282 1330 284 1355 286 1380 288 1500 290 1650 292 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1280 .055 1355 .06 Bank Sta: Left Right Lengths : Left Channel Right Coef f Contr. Expan. 1280 1355 84 84 84 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 289.59 Element Left OB Channel Right OB Vel Head (f t) 0.20 Wt. n-Val. 0.075 0.055 0.060 w.s . Elev (ft) 289.40 Reach Len. (ft) 84.00 84.00 84.00 Crit W.S. (ft) Flow Area (sq ft) 215.96 369.65 118. 29 E.G. Slope (ft/ft) 0.002664 Area (sq ft) 215.96 369.65 118. 29 Q Total (cfs) 1980.00 Flow (cfs) 336.24 1483.92 159.84 Top Width (ft) 298.60 Top Width (ft) 114. 88 75.00 108. 72 Vel Total (ft/s) 2.81 Avg. Vel. (ft/s) 1 .56 4 .01 1. 35 Max Chl Dpth (ft) 7.40 Hydr. Depth (ft) 1.88 4. 93 1. 09 Conv. Total (cfs) 38365.3 Conv. (cfs) 6515.0 28753.0 3097.2 Length Wtd. (ft) 84.00 Wetted Per. (ft) 114.94 75.66 108.81 Min Ch El (ft) 282.00 Shear (lb/sq ft) 0.31 0.81 0.18 Alpha 1. 60 Stream Power (lb/ft s) 0.49 3.26 0.24 Frctn Loss (ft) 0.14 Cum Volume (acre-ft) 83.61 37 .87 90.77 C & E Loss (ft) 0.00 Cum SA (acres) 28.03 4.43 30.66 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: N.F. Main RIVER: N.F. Lick Creek RS: 66216 INPUT Description: End Concrete Lined Channel Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev Sta 1000 290 1150 288 1205 286 1215 1240 281. 4 1260 284 1290 287 1300 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .06 1205 .04 1290 .04 Bank Sta: Left Right Lengths : Left Channel Right 1205 1290 1 1 1 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 289.45 Element Vel Head (ft) 0.21 Wt. n-Val. w.s. Elev (ft) 289.23 Reach Len . (ft) Crit W.S. (ft) Flow Area (sq ft) E.G. Slope (ft/ft) 0. 001165 Area (sq ft) Q Total (cfs) 1980.00 Flow (cfs) Top Width (ft) 239.89 Top Width (ft) Vel Total (ft/s) 3.05 Avg. Vel. (ft/s) Max Chl Dpth (ft) 7.83 Hydr. Depth (ft) Conv. Total (cfs) 58014.1 Conv. (cfs) Length Wtd . (ft) 1. 00 Wetted Per. (ft) Min Ch El (ft) 281.40 Shear (lb/sq ft) Alpha 1.49 Stream Power (lb/ft Frctn Loss (ft) 0.00 Cum Volume (acre-ft) C & E Loss (ft) 0.00 Cum SA (acres) Elev Sta Elev 284 1230 281.4 290 Coe ff Contr. Expan. .1 .3 Left OB Channel Right OB 0.060 0.040 0.040 1. 00 1. 00 1. 00 179.77 461 .27 8.31 179.77 461.27 8.31 173.38 1795.61 11. 01 147.45 85.00 7.44 0.96 3.89 1. 33 1. 22 5.43 1.12 5080.1 52611. 3 322.7 147.49 85.74 7.77 0.09 0.39 0.08 s) 0.09 1.52 0.10 83.23 37.07 90.65 27.78 4.28 30.55 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH : N.F. Main INPUT RIVER: N.F. Lick Creek RS: 66215 Description: End Concrete Lined Channel Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev 1000 290 1150 288 1205 286 1240 281.4 1260 284 1290 287 Manning's n Values num= 9 Sta n Val Sta n Val Sta n Val 1000 .06 1150 .06 1205 .04 1240 .014 1260 . 014 1290 .04 Sta Elev Sta Elev 1215 284 1230 281. 4 1300 290 Sta n Val Sta n Val 1215 .014 1230 . 014 1300 .04 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1205 1290 65 65 5 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G . Elev (ft) 289.44 El ement Left OB Channel Right OB Vel Head (ft) 0.26 Wt. n-Val. 0.060 0.015 0.040 w.s . Elev (ft) 289.19 Reach Len. (ft) 65.00 65 .00 5.00 Crit W.S. (ft) Flow Area (sq ft) 1 72. 92 457.27 7.96 E.G. Slope (ft/ft) 0.000166 Area (sq ft) 172 .92 457.27 7. 96 Q Total (cf s) 1980.00 Flow (cfs) 76.39 1899.68 3.93 Top Width (ft) 236.20 Top Width (ft) 143 .92 85.00 7.29 Vel Total (ft/s) 3.10 Avg. Vel. (ft/s ) 0.44 4 .15 0. 49 Max Chl Dpth (ft) 7 .79 Hydr. Depth (ft) 1.20 5.38 1.09 Conv. Total (cfs) 153760.1 Conv. (cfs) 5932.5 147522.8 304.9 Length Wtd. (ft) 64.79 Wetted Per. (ft) 143.96 85.74 7.61 Min Ch El (ft) 281.40 Shear (lb/sq ft) 0.01 0.06 0.01 Alpha 1. 72 Stream Power (lb/ft s) 0 .01 0.23 0.01 Frctn Loss (ft) 0.02 Cum Volume (acre-ft) 83.23 37.06 90.64 C & E Loss (ft) 0.01 Cum SA (acres) 27.77 4.28 30.55 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION RIVER : N.F. Lick Creek REACH: N.F. Main RS: 66150 INPUT Description: Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1060 290 1180 288 1200 286 1215 284 1230 281 1245 281 1255 284 1270 287 1290 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1060 .06 1200 .018 1270 .04 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 1200 1270 90 45 5 .1 .3 CROSS SECTION OUTPUT Prof ile #PF 1 E.G. Elev (ft) 289.42 Element Left OB Channel Right OB Vel Head (ft) 0.36 Wt. n-Val. 0.060 0.018 0.040 w.s . Elev (ft) 289.06 Reach Len. (ft) 90.00 45.00 5.00 Crit W.S. (ft) Fl ow Area (sq ft) 74.84 399.14 14 .13 E.G. Slope (ft/ft) 0.000347 Area (sq ft) 74.84 399.14 14 .13 Q Total (cfs) 1980 .00 Flow (cfs) 32.06 1938.04 9.90 Top Width (ft) 167.28 Top Width (ft) 83.55 70.00 13. 73 Vel Total (ft/s) 4 .06 Avg. Vel. (ft/s) 0.43 4.86 0.70 Max Chl Dpth (ft) 8.06 Hydr. Depth (ft) 0.90 5.70 1. 03 Conv. Total (cfs) 106263.8 Conv. (cfs) 1720.7 104011. 7 531.4 Length Wtd. (ft) 45.46 Wetted Per. (ft) 83.66 71.17 13.88 Min Ch El (ft) 281.00 Shear (lb/sq ft) 0.02 0.12 0.02 Alpha 1.40 Stream Power (lb/ft s) 0.01 0.59 0.02 Frctn Loss (ft) 0.01 Cum Volume (acre-ft) 83.04 36.42 90.64 C & E Loss (ft) 0.02 Cum SA (acres) 27.60 4.16 30.55 Warning : The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4 . This may indicate the need for additional cross sections. CROSS SECTION REACH: N.F. Main INPUT RIVER: N.F. Lick Creek RS: 66105 Description: End of Apron -Begin Lined Channel Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1310 1520 290 280 .8 Manning 's n Values Sta n Val 1310 .04 1430 1530 288 284 num= Sta n Val 1475 .014 1465 1550 3 Sta 1530 286 287 n Val .04 1475 1560 Bank Sta: Left 1475 Ineffective Flow Sta L Sta R Right 1530 Lengths: Left Channel 30 15 Right 5 1310 1475 CROSS SECTION OUTPUT E.G. Elev (ft ) Vel Head (ft) W.S. Elev (ft ) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s ) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft ) C & E Loss (ft ) CROSS SECTION REACH: N.F. Main INPUT Description: Station Elevation num= 2 Elev Sta L Sta R Elev 288 288 1530 1560 Profile #PF 1 289.39 0.28 289.10 284.94 0. 000119 1980.00 193.27 3.06 8.30 181786.3 15.58 280.80 1.94 0.00 0.05 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: N.F. Lick Creek RS: 66090 284 290 1490 Coeff Contr. .3 Left OB 0 . 040 30 .00 151.27 151.27 75.00 111. 25 0 .50 1. 36 6885.6 111. 52 0.01 0.00 82.81 27.40 Sta Elev 1200 290 1519.9 280.6 Data Sta 1340 1520 num= Elev 288 282 10 Sta 1470 1530 Elev 286 284 Sta 1470.l 1545 Elev 280.6 287 Sta 1490 1550 Manning's n Values Sta n Val 1200 . 04 num= Sta n Val 1470 .014 3 Sta 1530 n Val .04 Bank Sta : Left 1470 Ineffective Flow Sta L Sta R Right 1530 Lengths: Left Channel 40 15 Right 5 1200 1470 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) num= 2 Elev Sta L Sta R Elev 288 288 1520 1550 Profile #PF 1 289.34 0.19 289.15 284 .25 0.000084 1980.00 289.02 2.27 8.55 216116. 8 15.83 280.60 2.36 0 .00 0.05 Element Wt . n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Coeff Contr. . 3 Left OB 0.040 40.00 325.59 325 .59 148 .22 210 .43 0 .46 1.55 16178.5 210 .46 0.01 0.00 82.65 27.29 280.8 Expan. . 5 Channel 0.014 15.00 416.73 416.73 1839.85 55.00 4.41 7.58 168918.8 55.84 0 .06 0 .24 36.00 4 .10 Elev 280 .6 290 Expan. . 5 Channel 0.014 15.00 488.60 488.60 1790.23 60.00 3.66 8.14 195403.1 66.80 0.04 0.14 35.84 4.08 Right OB 0.040 5.00 79.46 79.46 65.15 27.01 0.82 2.94 5981 .8 27.55 0.02 0.02 90.64 30.55 Right OB 0 .040 5.00 58.58 58.58 41.55 18.58 0. 71 3.15 4535.2 19.47 0 .02 0.01 90.63 30.54 Warning : The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: N.F. Main RIVER: N.F. Lick Creek RS: 66075 I NPUT Description: Upstream Face of Graham Rd Culvert Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev 1140 290 1400 288 1470 287 1509 .9 280.5 1510 287 1700 288 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1140 .04 14 70 .014 1510 .04 Sta Elev Sta 1470.1 280.5 1490 1800 290 Bank Sta: Left Right Lengths: 1470 1510 Left Channel 75 75 Right 75 Coeff Contr. . 3 Ineffective Flow Sta L Sta R 1140 14 70 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (f t) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) num= 2 Elev Sta L Sta R Elev 288 1510 1800 288 Profile #PF 1 289 .28 0.36 288.92 284.73 0.000200 1980.00 466.08 2.53 8.42 140109.0 Element Wt . n-Val . Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv . Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 75.00 280 .50 3.64 Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) CULVERT REACH: N.F. Main RIVER: N.F. Lick Creek RS: 66037 INPUT Description : Graham Rd : 3 -9 ' x 5' Box Culv ert Distance from Upstream XS 10 Deck/Roadway Width 50 Weir Coefficient 3.1 Bridge Deck/Roadway Skew Upstream Deck/Roadway Coordinates num= 6 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 939 288.9 1115 288 1490 287.9 1754 289.5 Upstream Bridge Cross Section Data Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev 1140 290 1400 288 1470 287 1509.9 280.5 1510 287 1700 288 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1140 .04 14 70 .014 1510 .04 Bank Sta: Left Right Coef f Contr. Expan . 1470 1510 . 3 .5 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev Sta Hi Cord 1287 288.9 2054 291.6 Sta Elev 1470.l 280.5 1800 290 Left OB 0.040 75.00 154.92 154.92 70.99 189 .95 0.46 0.82 5023.7 189.96 0.01 0.00 82.43 27 .11 Lo Cord Sta 1490 Elev 280.5 Expan. . 5 Channel 0.014 75.00 336 .26 336.26 1732.82 40.00 5.15 8.41 122618.l 52.80 0 .08 0.41 35.70 4.06 Elev 280 .5 Right OB 0.040 75.00 291.59 291.59 176.19 236 .13 0.60 1.23 12467.2 236.15 0.02 0.01 90.61 30.53 1140 1470 288 1510 1800 288 Downstream Deck/Roadway Coordinates num= 6 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 904 288.9 1080 288 1252 288.9 1455 287.9 1719 289.5 2019 291.6 Downstream Bridge Cross Section Data Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 289 1290 288 1435 287 1435.l 280 .2 1455 280.2 1474.9 280 .2 1475 287 1600 288 1800 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .04 1435 .014 1475 .04 Bank Sta: Left Right Coef f Contr . Expan. 1435 1475 Ineffective Flow num= Sta L Sta R Elev Sta L 1000 1435 288 14 75 Upstream Embankment side slope Downstream Embankment side slope . 3 2 Sta R 1800 Maximum allowable submergence for weir flow Elevation at which weir flow begins Energy head used in spillway design Spillway height used in design . 5 Elev 288 .95 horiz. to 1.0 vertical horiz. to 1.0 vertical Weir crest shape Broad Crested Number of Cul verts 1 Culvert Name Shape Rise Span Graham Rd. Box 5 9 FHWA Chart # 11-Skewed headwall; Chamfered or beveled Inlet FHWA Scale# 2 -Headwall skewed 30 deg.; inlet edges chamfered 3/4 inch Solution Criteria = Highest U.S. EG Culvert Upstrm Dist Length n Value Entrance Loss Coef . 5 Exit Loss Coef 1 10 75 .014 Number of Barrels = Upstream Elevation Centerline Stations Sta. Sta . 1475 1485 Downstream El evation Centerline Stations Sta. Sta . 1440 1450 4 Sta. 1495 = Sta. 1460 280.5 Sta. 1505 280.2 Sta. 1470 CULVERT OUTPUT Profile #PF 1 Culvert ID : Graham Rd. Culv Q (cfs) # Barrels Q Barrel (cfs) E.G. US. (ft) w.s. us. (ft) Delta EG (ft) Delta ws (ft) E.G. IC (ft) E.G. OC (ft) Culvert Control Culv WS In (ft) Culv WS Out (ft) Culv Nml Depth (ft) Culv Crt Depth (ft) Culv Ful Lngh (ft) 1016.19 4 254.05 289.28 288.92 0.39 0.49 288.53 289.28 Outlet 285.50 285.20 2.91 75.00 Culv Vel In (ft/s ) Culv Vel Out (ft/s) Culv Inv El Up (ft) Culv Inv El Dn (ft) Cul v Frctn Ls (ft) Cul v Ext Lss (ft) Culv Ent Lss (ft) Q Weir (cfs) Weir Sta Lft (ft) Weir Sta Rgt (ft) Weir Submerg Weir Max Depth (ft) Weir Avg Depth (ft) Wr Fl w Area (sq ft) Min Top Rd (ft) 5.65 5 .65 280.50 280 .20 0 .11 0.03 0.25 963 .81 1231.77 1720.02 0.02 1.39 0.72 353.51 287.90 CROSS SECTION REACH: N.F. Main RIVER: N.F. Lick Creek RS: 66000 INPUT Description: Downstream Face of Graham Rd Culvert Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev Sta 1000 289 1290 288 1435 287 1435 .1 14 74. 9 280.2 1475 287 1600 288 1800 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .04 1435 .014 1475 .04 Bank Sta: Left Right Lengths: Left Channel Right 1435 1475 20 20 20 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1435 288 1475 1800 288 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 288.89 Element Vel Head (ft) 0.46 Wt. n-Val. w.s. Elev (ft) 288.43 Reach Len. (ft) Crit W.S . (ft) 284.45 Flow Area (sq ft ) E.G. Slope (ft/ft) 0.000250 Area (sq ft) Q Total (cfs) 1980.00 Flow (cfs) Top Width (ft) 477.40 Top Width (ft) Vel Total (ft/s) 3.22 Avg. Vel. (ft/s) Max Chl Dpth (ft) 8.23 Hydr. Depth (ft) Conv. Total (cfs) 125143 .5 Conv. (cfs) Length Wtd. (ft) 20.00 Wetted Per. (ft) Min Ch El (ft) 280.20 Shear (lb/sq ft) Alpha 2.87 Stream Power (lb/ft Frctn Loss (ft) 0.00 Cum Volume (acre-ft) C & E Loss (ft) 0 .17 Cum SA (acres) Elev Sta Elev 280.2 1455 280.2 290 Coe ff Contr. Expan. .3 .5 Left OB Channel Right OB 0.040 0.014 0.040 20.00 20.00 20.00 161.45 328.49 125.37 161.45 328.49 125.37 67.44 1851.92 60 .64 269.48 40.00 167.92 0.42 5.64 0.48 0.60 8.21 0.75 4262.5 117048 .5 3832.5 269.48 53.40 167.93 0.01 0.10 0.01 s) 0.00 0.54 0.01 82.15 35 .13 90.25 26. 71 3.99 30.18 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections . CROSS SECTION REACH: N.F. Main INPUT Description: Station Elevation Sta Elev 1000 289 1455 280.13 1800 290 Manning's n Values Sta n Val 1000 .04 RIVER: N.F. Lick Creek RS: 65980 Data num= 11 Sta Elev Sta Elev 1290 288 1410 286 1474.9 280 .13 1475 284 num= 3 Sta n Val Sta n Val 1420 .014 1475 .014 Bank Sta: Left Right Lengths: Left Channel 1420 1475 10 10 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1420 288 1475 1800 288 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 288.72 Element Vel Head (ft) 0.13 Wt. n-Val. w.s. Elev (ft) 288.59 Reach Len. Crit W.S. (ft) 283.56 Flow Area Sta 1420 1525 Right 10 (ft) (sq ft) E.G. Slope (ft/ft) 0.000065 Area (sq ft) Q Total (cfs) 1980.00 Flow (cfs) Elev Sta Elev 284 1420.1 280 .13 286 1600 288 Coef f Contr. Expan. .3 . 5 Left OB Channel Right OB 0. 040 0.014 0.014 10.00 10.00 10.00 277.98 465.06 316.65 277.98 465 .06 316.65 78.63 1513.42 387.95 Top Width (ft) 541.15 Top Width (ft) 301.88 55.00 184.27 Vel Total (ft/s) 1. 87 Avg. Vel. (ft/s) 0.28 3.25 1. 23 Max Chl Dpth (ft) 8.46 Hydr . Depth (ft) 0.92 8.46 1. 72 Conv. Total (cfs) 246020.4 Conv. (cfs) 9769.5 188046.5 48204.5 Length Wtd. (ft) 10.00 Wetted Per. (ft) 302.09 62.54 184 .34 Min Ch El (ft) 280.13 Shear (lb/sq ft) 0.00 0.03 0.01 Al pha 2.40 Stream Power (lb/ft s ) 0.00 0.10 0.01 Frctn Loss (ft) 0.00 Cum Volume (acre-ft) 82.05 34.94 90 .15 C & E Loss (ft) 0.00 Cum SA (acres) 26.58 3.97 30.10 CROSS SECTION RIVER: N.F. Lick Creek REACH : N.F. Main RS: 65970 INPUT Description: Begin Concrete Apron Station Elevation Data num= 13 Sta El ev Sta Elev Sta Elev Sta Elev Sta Elev 1000 289 1290 288 1400 286 1410 284 1415 282 1420 280.1 1455 280 .1 1475 280 .1 1480 282 1485 284 1525 286 1600 288 1800 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .065 1410 .02 1485 .065 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1410 1485 1 1 1 . 3 .5 Ineffective Flow num= 2 Sta L Sta R El ev Sta L Sta R Elev 1000 1420 288 1475 1800 288 CROSS SECTI ON OUTPUT Profile #PF 1 E.G. Elev (ft) 288. 72 El ement Left OB Channel Right OB Vel Head (f t) 0 .13 Wt. n-Val. 0.065 0.020 0.065 w.s. Elev (f t) 288.59 Reach Len. (ft) 1. 00 1. 00 1. 00 Crit W.S. (ft) 283.52 Flow Area (sq ft) 259 .96 597 .91 279.47 E.G . Slope (ft/ft) 0.000109 Area (sq ft) 259.96 597 .91 279.47 Q Total (cfs) 1980.00 Flow (cfs) 57.79 1830 .43 91.78 Top Width (ft) 538.34 Top Width (ft) 289.79 75.00 173.55 Vel Total (ft/s) 1. 74 Avg . Vel. (ft/s) 0.22 3.06 0.33 Max Chl Dpth (ft) 8.49 Hydr. Depth (ft) 0.90 7.97 1. 61 Conv. Total (cfs) 189300.0 Conv. (cfs) 5524.9 175000.5 8774.6 Length Wtd . (ft) 1. 00 Wetted Per. (ft) 290.01 76.47 173.63 Min Ch El (ft) 280 .10 Shear (lb/sq ft) 0.01 0.05 0.01 Alpha 2.86 Stream Power (l b/ft s) 0.00 0.16 0.00 Frctn Loss (ft) 0.00 Cum Volume (acre-ft) 81.99 34.82 90.08 C & E Loss (ft) 0.01 Cum SA (acres) 26.51 3.95 30.06 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: N.F. Main RIVER: N.F. Lick Creek RS: 65969 INPUT Description : Begin Concrete Apron Station El evation Data num= 13 Sta Elev Sta El ev St a Elev 1000 289 1290 288 1400 286 1420 280.1 1455 280.1 1475 280.1 1525 286 1600 288 1800 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1410 .04 1485 .075 Bank Sta: Left Right Lengths: Left Channel 1410 1485 19 19 Sta El ev Sta Elev 1410 284 1415 282 1480 282 1485 284 Right Coef f Contr. Expan. 19 . 3 . 5 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1420 288 1475 1800 288 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 288 .71 Element Left OB Channel Right OB Vel Head (ft) 0.11 Wt. n-Val. 0.075 0.040 0.075 w.s. Elev (ft) 288 .60 Reach Len. (ft) 19 .00 19.00 19 .00 Crit W.S. (ft) 283.52 Flow Area (sq ft) 262.79 598 .64 281.16 E.G. Slope (ft/ft) 0.000391 Area (sq ft) 262.79 598.64 281.16 Q Total (cfs) 1980 .00 Flow (cfs) 95.74 1732.99 151.26 Top Width (ft) 542.12 Top Width (ft) 292.60 75.00 174 .52 Vel Total (ft/s ) 1.73 Avg. Vel. (ft/s) 0.36 2.89 0.54 Max Chl Dpth (ft:) 8.50 Hydr. Depth (ft) 0.90 7.98 1.61 Conv. Total (cfs) 100174.8 Conv. (cfs) 4844 .0 87677 .8 7652 .9 Length Wtd. (ft) 19.00 Wetted Per. (ft) 292 .82 76 .47 174.60 Min Ch El (ft) 280.10 Shear (lb/sq ft) 0.02 0.19 0 .04 Alpha 2.45 Stream Power (l b/ft s ) 0.01 0.55 0.02 Frctn Loss (ft) 0.01 Cum Volume (acre-ft) 81.98 34.81 90.08 C & E Loss (ft) 0.06 Cum SA (acres) 26.51 3.95 30.06 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: N.F. Lick Creek REACH : N.F. Main RS: 65950 INPUT Description: Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta 1000 288.5 1160 288 1270 286 1310 1335 280 1345 282 1350 284 1410 1700 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1310 .04 1350 .075 Bank Sta: Left Right Lengths: Left Channel Right 1310 1350 200 250 300 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 288.63 Element Vel Head (ft) 0.32 Wt . n-Val . w.s. Elev (ft ) 288.31 Reach Len. (ft) Crit W.S. (ft) Flow Area (sq ft) E.G. Slope (ft/ft) 0.001880 Area (sq ft) Q Total (cfs) 1980.00 Flow (cfs) Top Width (ft) 428.85 Top Width (ft) Vel Total (ft/s) 2.47 Avg. Vel. (ft/s) Max Chl Dpth (ft) 8.31 Hydr. Depth (ft) Conv. Total (cfs) 45667.8 Conv. (cfs) Length Wtd. (ft) 250.06 Wetted Per. (ft) Min Ch El (ft) 280.00 Shear (lb/sq ft) Alpha 3.40 Stream Power (lb/ft Frctn Loss (ft) 0.42 Cum Volume (acre-ft ) C & E Loss (ft) 0.08 Cum SA (acres) CROSS SECTION REACH: N.F. Main RIVER: N.F. Lick Creek RS: 65700 INPUT Description: Station Elevation Data Sta Elev Sta 1000 289 1200 num= Elev 288 14 Sta 1260 Elev 286 Sta 1270 s ) Elev Sta 284 1325 286 1450 Coef f Contr. . 3 Left OB Elev 284 0.075 200.00 292.38 292.38 278.85 249.84 0.95 1.17 6431. 6 249 .91 0.14 0.13 81.86 26.39 Sta 1300 Elev 282 288 Expan. . 5 Channel 0.040 250.00 252.48 252.48 1368 .11 40.00 5 .42 6 .31 31554.9 40 .91 0 .72 3.92 34.62 3 .93 Elev 284 Right OB 0.075 300.00 257.29 257.29 333.04 139.00 1. 29 1. 85 7681. 3 139.09 0.22 0.28 89 .96 29.99 1320 282 1330 280 1340 279.5 1350 280 1355 282 1365 284 1410 286 1440 288 1530 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1300 .055 1365 .075 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1300 1365 180 200 220 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 288 .13 El ement Left OB Channel Right OB Vel Head (ft) 0.16 Wt. n-Val. 0.075 0.055 0.075 w.s . Elev (ft) 287 .97 Reach Len. (ft) 180 .00 200.00 220.00 Crit W.S. (ft) Flow Area (sq ft) 207.20 418.17 162.90 E.G. Slope (ft/ft) 0.001516 Area (sq ft) 207 .20 418.17 162.90 Q Total (cfs) 1980.00 Flow (cfs ) 260.87 1507.78 211. 36 Top Width (ft) 238.73 Top Width (ft) 99.16 65 .00 74.58 Vel Total (ft/s) 2.51 Avg. Ve l. (ft/s) 1.26 3 .61 1. 30 Max Chl Dpth (ft) 8. 4 7 Hydr. Depth (ft) 2 .09 6.43 2.18 Conv. Total (cfs) 50847.3 Conv. (cfs) 6699.2 38720.3 5427.7 Length Wtd. (ft) 199.16 Wetted Per. (ft) 99.39 65.91 74.69 Min Ch El (ft) 279.50 Shear (lb/sq ft) 0.20 0.60 0.21 Alpha 1. 63 Stream Power (lb/ft s) 0 .25 2.17 0.27 Frctn Loss (ft) 0.42 Cum Volume (acre-ft) 80.72 32.70 88.51 C & E Loss (ft) 0.01 Cum SA (acres) 25.59 3 .63 29.25 Warning : The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4 . This may indicate the need for additional cross sections. CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main INPUT Description: Station Elevation Data Sta El ev Sta 1000 289 1080 1365 280 1375 1430 286 1525 Manning's n Values Sta n Val Sta 1000 .075 1360 Bank Sta: Left 1360 Right 1388 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft ) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft ) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) RS: 65500 num= 13 Elev Sta Elev Sta 288 1280 286 1340 278.9 1380 280 1388 288 1555 290 num= 3 n Val Sta n Val .055 1388 .075 Lengths: Left Channel Right 250 250 250 Profile #PF 1 287.70 0.29 287.41 0.003156 1980.00 357.41 2.65 8.51 35243.3 250.00 278.90 2.67 0.68 0.03 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft ) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) CROSS SECTION REACH: N.F. Main RIVER: N.F. Lick Creek RS: 65250 Elev Sta 284 1360 282 1420 Coeff Contr. .l Left OB 0.075 250.00 331.36 331.36 483.51 220.62 1.46 1. so 8606.3 220.76 0 .30 0.43 79.60 24.93 Elev 282 284 Expan. .3 Channel 0.055 250.00 202.62 202.62 1128 . 91 28.00 5.57 7.24 20094.2 28.81 1.39 7.72 31. 27 3.41 Right OB 0.075 250.00 212.02 212.02 367.58 108.79 1.73 1.95 6542.8 109.07 0.38 0.66 87.56 28.79 INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 288 llOO 286 1190 284 1260 284 1290 282 1295 280 1300 278 .2 1310 280 1320 282 1350 284 1380 286 1490 288 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1290 .055 1320 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1290 1320 210 200 190 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G . Elev (ft ) 286 .98 Element Left OB Channel Right OB Vel Head (ft) 0.18 Wt . n-Val. 0.075 0.055 0 .075 w.s. Elev (ft ) 286.81 Reach Len. (ft) 210.00 200.00 190 .00 Crit W.S. (ft ) Flow Area (sq ft ) 489.22 202.66 186.15 E .G. Slope (ft/ft ) 0.002384 Area (sq ft) 489 .22 202 .66 186 .15 Q Total (cfs) 1980.00 Flow (cfs) 781.85 933 .43 264.72 Top Width (ft ) 364.56 Top Width (ft) 230.26 30.00 104.29 Vel Total (ft/s ) 2.26 Avg. Vel. (ft/s) 1. 60 4 .61 1.42 Max Chl Dpth (ft) 8.61 Hydr. Depth (ft) 2.12 6.76 1. 78 Conv. Total (cfs) 40554.7 Conv. (cfs) 16014 .0 19ll8. 7 5422.0 Length Wtd. (ft) 201 .95 Wetted Per. (ft) 230 .36 31. 06 104.43 Min Ch El (ft ) 278.20 Shear (lb/sq ft) 0.32 0 .97 0.27 Alpha 2.22 Stream Power (lb/ft s ) 0.51 4.47 0.38 Frctn Loss (ft) 0.64 Cum Volume (acre-ft) 77 .25 30. ll 86.42 C & E Loss (ft) 0.02 Cum SA (acres) 23.63 3.25 28.18 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 65050 INPUT Description: Station Elevation Data num= 14 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 1000 287 ll30 286 1240 284 1290 282 1300 280 1305 278 1310 277.6 1315 278 1320 280 1325 282 1345 284 1400 286 1460 286 1520 288 Manning 's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1290 .055 1325 .075 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 1290 1325 250 250 23 0 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E .G. Elev (ft) 286.32 El ement Left OB Channel Right OB Vel Head (ft) 0 .40 Wt. n-Val. 0.0 75 0.055 0.075 w.s. Elev (ft ) 285 .92 Reach Len. (ft) 250.00 250.00 230 .00 Crit W.S. (ft ) Flow Area (sq ft ) 247.40 224.21 109.10 E.G. Slope (ft/ft) 0.004396 Area (sq ft) 247.40 224.21 109.10 Q Total (cfs) 1980.00 Flow (cfs) 442.62 1349.93 187.45 Top Width (ft ) 263.41 Top Width (ft ) 155.61 35.00 72 . 80 Vel Total (ft/s ) 3.41 Avg . Vel. ( ft/s ) 1.79 6.02 1. 72 Max Chl Dpth (ft ) 8.32 Hydr. Depth (ft ) 1.59 6.41 1. 50 Conv. Total (cfs) 29861.5 Conv . (cfs) 667 5.4 20359.l 2827.1 Length Wtd. (ft) 244 .65 Wetted Per. (ft) 155.67 36.39 72.94 Min Ch El (ft ) 277.60 Shear (lb/sq ft) 0 .44 1.69 0.41 Alpha 2.21 Stream Power (lb/ft s) 0 .78 10.18 0. 71 Frctn Loss (ft) 0 .79 Cum Volume (acre-ft) 75 .47 29.13 85.78 C & E Loss (ft) 0.05 Cum SA (acres) 22 .70 3 .10 27.79 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 64800 INPUT Description: Station Elevation Data num= 13 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 1000 287 1015 286 1025 284 1040 282 1055 280 1060 278 1065 276.9 1070 278 1080 280 1110 282 1260 284 1350 286 1380 288 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .07 1055 .05 1080 .07 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1055 1080 270 300 330 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 285.48 El ement Left OB Channel Right OB Vel Head (ft) 0.22 Wt. n-Val . 0.070 0 .050 0.070 w.s. Elev (ft) 285.26 Reach Len. (ft) 270.00 300 .00 330.00 Crit W.S. (ft) Flow Area (sq ft) 101.77 172. 00 502.54 E.G. Slope (ft/ft) 0.002453 Area (sq ft) 101.77 172 .00 502.54 Q Total (cfs) 1980.00 Flow (cfs) 211. 23 896.25 872.52 Top Width (ft) 298.00 Top Width (ft) 36.30 25 .00 236.70 Vel Total (ft/s) 2.55 Avg. Vel. (ft/s) 2.08 5.21 1 .74 Max Chl Dpth (ft) 8.36 Hydr. Depth (ft) 2.80 6.88 2.12 Conv. Total (cfs) 39977.7 Conv. (cfs) 4264.9 18096.0 17616.8 Length Wtd. (ft) 301.47 Wetted Per. (ft) 36.69 25.82 236.80 Min Ch El (ft) 276.90 Shear (lb/sq ft) 0.42 1.02 0.32 Alpha 2.16 Stream Power (lb/ft s) 0.88 5.32 0.56 Frctn Loss (ft) 0.44 Cum Volume (acre-ft) 74.47 27.99 84.16 C & E Loss (ft) 0.03 Cum SA (acres) 22.15 2. 92 26.97 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4 . This may indicate the need for additional cross sections. CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main INPUT Description: Station Elevation Data Sta Elev 1000 286 1455 276 1610 286 Manning's n Values Sta n Val 1000 .06 Sta 1200 1460 Sta 1440 Bank Sta: Left 1440 Right 1465 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) RS: 64500 num= Elev 284 278 num= n Val .04 11 Sta 1340 1465 3 Sta 1465 Elev 282 280 n Val .06 Sta 1440 1510 Lengths: Left Channel Right 120 Profile #PF 1 285.01 0.10 284.90 0.000958 1980.00 478.33 1. 70 8.90 63976.3 80 100 El ement Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg . Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) El ev Sta 280 1448 282 1570 Coeff Contr. .3 Left OB 0.060 80.00 697.41 697.41 879.74 330.28 1.26 2 .11 28425.6 Elev 278 284 Expan . .5 Channel 0.040 100.00 171. 57 171. 57 688.73 25.00 4.01 6.86 22253.6 Right OB 0.060 120.00 297.94 297.94 411. 53 123.06 1. 38 2.42 13297.1 Length Wtd . (ft) 97.63 Wetted Per. (ft) 330.32 26.30 123.16 Min Ch El (ft) 276.00 Shear (lb/sq ft) 0 .13 0.39 0.14 Alpha 2.33 Stream Power (lb/ft s ) 0.16 1. 57 0.20 Frctn Loss (ft) 0.08 Cum Volume (acre-ft) 72.00 26.81 81.13 C & E Loss (ft) 0.05 Cum SA (acres) 21.02 2.75 25.61 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 64395 INPUT Description: Upstream Face of SH6 Culvert Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 286 1300 285 1350 284 1425 282 1460 280 1465 274.85 1505 274.85 1510 280 1580 282 1720 284 1770 286 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .06 1460 .04 1510 .06 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 1460 1510 475 475 475 .3 . 5 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1460 287 1510 1770 287 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 284.87 Element Left OB Channel Right OB Vel Head (ft) 0.29 Wt. n-Val. 0.040 w.s. Elev (ft) 284.58 Reach Len. (ft) 475.00 475.00 475.00 Crit W.S. (ft) 278.93 Fl ow Area (sq ft) 460.80 E.G. Slope (ft/ft) 0.000774 Area (sq ft) 252 .35 460.80 476.23 Q Total (cfs) 1980 .00 Fl ow (cfs) 1980.00 Top Width (ft) 413.57 Top Width (ft) 139.05 50 .00 224.52 Vel Total (ft/s) 4.30 Avg. Vel. (ft/s) 4.30 Max Chl Dpth (ft) 9.73 Hydr. Depth (ft) 9.22 Conv. Total (cfs) 71169. 0 Conv. (cfs) 71169.0 Length Wtd. (ft) 475.00 Wetted Per. (ft) 54.36 Min Ch El (ft) 274.85 Shear (lb/sq ft) 0.41 Alpha 1. 00 Stream Power (lb/ft s ) 1.76 Frctn Loss (ft) Cum Volume (acre-ft) 71.12 26.08 80.06 C & E Loss (ft) Cum SA (acres) 20.59 2 .67 25.13 CULVERT RIVER: N.F. Lick Creek REACH: N.F. Main RS: 64158 INPUT Description: SH 6 Culvert 3 -10' x 8 ' MBC Distance from Upstream XS 25 Deck/Roadway Width 425 Weir Coefficient 2.6 Bridge Deck/Roadway Skew Upstream Deck/Roadway Coordinates num= 2 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 1000 287 2000 287 Upstream Bridge Cross Section Data Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 286 1300 285 1350 284 1425 282 1460 280 1465 274 .85 1505 274.85 1510 280 1580 282 1720 284 1770 286 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .06 1460 .04 1510 .06 Bank Sta: Left Right Coe ff Contr. Expan. 1460 1510 .3 .5 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1460 287 1510 1770 287 Downstream Deck/Roadway Coordinates num= 2 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 1000 287 2000 287 Downstream Bridge Cross Section Data Station Elevation Data num= 12 Sta El ev Sta Elev Sta Elev Sta Elev Sta 1000 284 llOO 282 1250 280 1280 278 1281 1285 273.4 1315 273.4 1318 276 1320 278 1325 1450 280 1480 284 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .06 1280 .04 1320 .06 Bank Sta: Left Right Coe ff Contr . Expan. 1280 1320 . 3 . 5 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1280 287 1320 1480 287 Upstream Embankment side slope Downstream Embankment side slope horiz. to 1.0 vertical horiz. to 1.0 vertical Maximum allowable submergence for weir flow Elevati on at which weir flow begins Energy head used in spillway design Spillway height used in design Weir crest shape Number of Culverts 1 Culvert Name Shape Rise Span Hwy 6 N Box 8 10 .95 Broad Cr ested FHWA Chart # 11 -Skewed headwall; Chamfered or beveled Inlet FHWA Scale# 1 -Headwall skewed 45 deg.; inlet edges chamfered 3/4 inch Solution Criteria = Highest U.S. EG Culvert Upstrm Dist Length n Value Entrance Loss Coef .5 25 474 .014 Number of Barrels = 3 Upstream Elevation 274.8 Centerline Stations Sta. Sta. Sta. 1470 1481 1492 Downstream Elevation = 273.4 Centerline Stations Sta. Sta. Sta. 1286 1297 1308 CULVERT OUTPUT Profil e #PF 1 Culvert ID : Hwy 6 N Culv Q (cfs) 1980 .00 Culv Vel In (ft/s) # Barrels 3 Culv Vel Out (ft/s) Q Barrel (cfs) 660.00 Culv Inv El Up (ft) E.G. us. (ft) 284.87 Culv Inv El Dn (ft) w.s. us. (ft) 284.58 Culv Frctn Ls (ft) Delta EG (ft) 1.85 Culv Ext Lss (ft) Delta WS (ft) 2.28 Culv Ent Lss (ft) E .G. IC (ft) 283 .70 Q Weir (cfs) E.G. oc (ft) 284.87 Weir Sta Lft (ft ) Culvert Control Outlet Weir Sta Rgt (ft) Culv WS In (ft) 282.80 Weir Submerg Culv WS Out (ft) 281.40 Weir Max Depth (ft) Exit Loss Coef 1 8 .25 8.25 274 .80 273 .40 0.99 0.33 0.53 Elev 276 280 Culv Nml Depth (ft) Culv Crt Depth (ft) Culv Ful Lngh (ft) 5.13 474.00 Weir Avg Depth (ft) Wr Flw Area (sq ft) Min Top Rd (ft) 287.00 CROSS SECTION REACH: N.F. Main RIVER: N.F. Lick Creek RS: 63920 I NPUT Description: Downstream Face of SH6 Station Elevation Sta El ev 1000 284 1285 273.4 1450 280 Manning's n Values Sta n Val 1000 . 06 Data num= Sta Elev llOO 282 1315 273.4 1480 284 num= Sta n Val 1280 . 04 Bank Sta: Left Right Lengths: 1280 1320 Ineffective Fl ow num= 2 Sta L Sta R Elev Sta L 1000 1280 287 1320 Culvert 12 Sta 1250 1318 3 Sta 1320 Structure Elev 280 276 n Val .06 Sta 1280 1320 Left Channel Right 90 50 30 Sta R Elev 1480 287 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 283.03 0.73 282.30 278.58 0.002245 2301 .00 382.23 6.85 8.90 48567 .l 53.56 273.40 1. 00 0.13 0.28 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s ) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft ) Stream Power (l b/ft s) Cum Volume (acre-ft) Cum SA (acres) Elev Sta 278 1281 278 1325 Coeff Contr. . 3 Left OB 90 .00 296 .19 194.99 68 .13 18 .76 Elev 276 280 Expan. .5 Channel 0.040 50.00 336.09 336 .09 2301.00 40.00 6 .85 8.40 48567.l 43.81 1. 08 7.36 21.74 2 .18 Right OB 30 .00 323 .80 147.25 75.70 23.11 Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. CROSS SECTION RIVER: N.F. REACH: N.F. Main RS: 63870 INPUT Description: Station Elevation Data num= Sta El ev Sta Elev 970 284 1000 282 1230 276 1231 274 1255 278 1260 280 Manning's n Val ues num= Sta n Val Sta n Val 970 .07 1225 .055 Bank Sta: Left Right Lengths: 1225 1255 CROSS SECTION OUTPUT Profile #PF E.G. Elev (ft) 282.62 Vel Head (ft) 0 .17 Lick Creek 15 Sta Elev ll50 280 1235 273.3 1380 280 3 Sta n Val 1255 .07 Left Channel 100 100 1 El ement Wt. n-Val. Sta 1190 1238 1390 Right 90 El ev Sta 280 1225 274 1245 282 1400 Coeff Contr. .1 Left OB 0 .070 Elev 278 276 284 Expan. . 3 Channel 0 .055 Right OB 0.070 w.s. Elev (ft) 282.45 Reach Len. (ft) 100.00 100.00 90.00 Crit w.s . (ft) Fl ow Area (sq ft) 437.63 202.93 326.17 E.G. Slope (ft/ft) 0.002595 Area (sq ft) 437.63 202.93 326.17 Q Total (cfs) 2301 .00 Flow (cfs) 722.78 952.04 626.18 Top Width (ft) 398.99 Top Width (ft ) 231.74 30.00 137.25 Vel Total (ft/s) 2 .38 Avg. Ve l . (ft/s) 1. 65 4.69 1.92 Max Chl Dpth (ft) 9.15 Hydr. Depth (ft) 1. 89 6.76 2.38 Conv. Total (cfs) 45172.6 Conv. (cfs) 14189.5 18690.2 12293.0 Length Wtd. (ft) 96.09 Wetted Per. (ft) 231.83 32.24 137.87 Min Ch El (ft) 273.30 Shear (lb/sq ft) 0.31 1. 02 0.38 Alpha 1. 94 Stream Power (lb/ft s) 0.51 4.78 0.74 Fr ctn Loss (ft) 0.22 Cum Volume (acre-ft) 67.37 21.43 75.48 C & E Loss (ft) 0.02 Cum SA (acres) 18.32 2.14 23.01 CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 63770 INPUT Description: Station Elevation Data num= 14 Sta El ev Sta Elev Sta Elev Sta Elev Sta Elev 1000 284 1030 282 1170 280 1190 278 1200 276 1205 274 1210 273.2 1215 274 1218 276 1220 278 1260 280 1500 280 1520 282 1600 284 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .07 1190 .06 1220 .07 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1190 1220 300 300 250 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 282.38 Element Left OB Channel Right OB Vel Head (ft) 0 .11 Wt. n-Val. 0.070 0.060 0.070 w.s. Elev (ft ) 282.27 Reach Len. (ft) 300.00 300.00 250.00 Crit W.S. (ft) Flow Area (sq ft ) 243.26 208.01 701. 53 E.G. Slope (ft/ft) 0.002099 Area (sq ft) 243.26 208 .01 701.53 Q Total (cfs) 2301.00 Flow (cfs) 307.53 819.57 1173 .89 Top Width (ft ) 504.69 Top Width (ft) 164.01 30.00 310.68 Vel Total (ft/s) 2.00 Avg. Vel. (ft/s) 1. 26 3. 94 1.67 Max Chl Dpth (ft) 9.07 Hydr. Depth (ft) 1. 48 6.93 2.26 Conv. Total (cfs) 50224.3 Conv. (cfs) 6712. 6 17888.9 25622.8 Length Wtd. (ft) 284.41 Wetted Per. (ft) 164.13 32.14 310.83 Min Ch El (ft) 273.20 Shear (lb/sq ft) 0.19 0 .85 0.30 Alpha 1.80 Stream Power (lb/ft s) 0.25 3.34 0. 49 Frctn Loss (ft) 1.28 Cum Volume (acre-ft) 66.59 20.96 74.42 C & E Loss (ft) 0.06 Cum SA (acres) 17.87 2.07 22.55 Warning : The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: N.F. Main INPUT Description: Station Elevation Sta Elev 1000 281 1345 274 1410 280 Data RIVER: N.F . Lick Creek RS: 63470 num= 12 Sta Elev Sta Elev 1100 280 1260 279 1350 272.8 1355 274 1470 281 Sta Elev Sta Elev 1320 278 1340 276 1360 276 1370 278 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .07 1340 .065 1360 .075 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1340 1360 250 250 250 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E .G. Elev (ft) 281.04 Element Left OB Channel Right OB Vel Head (ft) 0.72 Wt. n-Val. 0 .070 0.065 0.075 w.s . Elev (ft) 280.32 Reach Len. (ft) 250.00 250.00 250.00 Crit W.S. (ft) 280.32 Flow Area (sq ft) 313.26 122.50 89 .41 E.G. Slope (ft/ft) 0.015563 Area (sq ft) 313.26 122.50 89.41 Q Total (cfs) 2301 .00 Flow (cfs) 910 .11 1130 .10 260.80 Top Width (ft) 361.99 Top Width (f t) 272.49 20 .00 69 .50 Vel Total (ft/s) 4.38 Avg. Vel. (ft/s) 2.91 9.23 2.92 Max Chl Dpth (ft) 7 .52 Hydr. Depth (ft) 1.15 6.12 1. 29 Conv. Total (cfs) 18444.8 Conv. (cfs) 7295.4 9058.8 2090.5 Length Wtd. (ft) 250 .00 Wetted Per. (ft) 272.60 21.05 69.75 Min Ch El (ft) 272.80 Shear (lb/sq ft) 1. 12 5.65 1. 25 Alpha 2 .40 Stream Power (lb/ft s) 3.24 52.15 3.63 Frctn Loss (ft) 1.79 Cum Volume (acre-ft) 64.68 19.82 72.15 C & E Loss (ft) 0.16 Cum SA (acres) 16.37 1. 89 21.45 Warning: The energy equation could not be balanced within the specified number of iterations. The progr am sel ected the water surface that had the least amount of error between computed and assumed val ues. Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for addi tional cross sections. Warning: The conveyance rat io (upstream conveyance d ivided by downstream conveyance) is less than 0.7 or greater than 1.4 . This may indicate the need for additional cross sections. Warning : The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Wa r ning: During the standard step iterations, when the assumed water surface was set equal to crit ical depth, the calcul ated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. CROSS SECTION RI VER: N.F . REACH: N.F. Main INPUT Description: Station Elevation Data Sta Elev 1000 281.4 1140 272.4 1450 280.5 Manning's n Values Sta n Val 1000 .07 Sta 1040 1150 Sta 1120 Bank Sta: Lef t Right 1120 1160 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) w.s . Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (f t/s) Max Chl Dpth (ft) RS: 63220 num= Elev 280 273 num= n Val .065 Lengths: Profil e #PF 278.81 0.19 278.62 0. 004114 2301.00 271.57 2.96 6.22 Lick 11 Sta 1100 1160 3 Sta 1160 Left 499 1 Creek Elev 278 274 n Val .075 Channel 499 Element Wt. n-Val. Reach Len. Fl ow Area Sta 1120 1350 Right 499 (ft) (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel . (ft/s) Hydr. Depth (ft) Elev Sta 274 1130 278 1360 Coeff Contr . .1 Left OB 0.070 499 .00 58.03 58.03 103 .15 38.49 1. 78 1. 51 Elev 273 280 Expan. . 3 Channel 0.065 499.00 220.66 220.66 1007.82 40.00 4.57 5.52 Right OB 0.075 499.00 498.06 498.06 1190. 03 193.08 2. 39 2 .58 Conv. Total (cfs) 35874.5 Conv. (cfs) 1608.2 15712.8 18553 .6 Length Wtd . (ft) 499.00 Wetted Per. (ft) 38.90 40. 14 193.19 Min Ch El (ft) 272.40 Shear (lb/sq ft) 0.38 1.41 0.66 Alpha 1.39 Stream Power (lb/ft s ) 0.68 6.45 1.58 Frctn Loss (ft ) 2.02 Cum Volume (acre-ft) 63.61 18.84 70 .46 C & E Loss (ft ) 0.00 Cum SA (acres) 15.47 1. 72 20.70 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: N.F. Main RIVER : N.F. Lick Creek RS: 62721 INPUT Description: Station Elevation Data num= 13 Sta Elev Sta Elev Sta Elev Sta 1000 280 1030 278 1050 276 1070 1090 270 llOO 268.5 ll05 270 lllO 1410 276 1550 276 1860 278 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .07 1075 .065 lllO .075 Bank Sta: Left Right Lengths: Left Channel Right 1075 1110 1 1 1 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 276.79 Element Vel Head (ft) 0.19 Wt. n-Val . w.s . Elev (ft) 276.60 Reach Len. (ft) Crit W.S. (ft) Flow Area (sq ft ) E.G. Slope (ft/ft) 0 .003980 Area (sq ft) Q Total (cfs) 2301.00 Flow (cfs) Top Width (ft) 598.20 Top Width (ft) Vel Total (ft/s) 2.29 Avg. Vel. (ft/s) Max Chl Dpth (ft) 8.10 Hydr. Depth (ft) Conv. Total (cfs) 36474.0 Conv. (cfs) Length Wtd. (ft ) 1. 00 Wetted Per. (ft) Min Ch El (ft) 268.50 Shear (lb/sq ft) Alpha 2.36 Stream Power (lb/ft Frctn Loss (ft) 0.00 Cum Volume (acre-ft) C & E Loss (ft) 0.04 Cum SA (acres) CROSS SECTION REACH: N.F. Main RIVER: N.F. Lick Creek RS : 62720 INPUT Description: x -section from 1987 FEMA Study Station Elevation Data num= 13 Sta Elev Sta Elev Sta Elev Sta 1000 284 llOO 281 .8 1200 279.7 1300 1347 268 .5 1354 274 1400 274 .4 1500 1700 274 .4 1800 275 .3 1900 280 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .07 1339 .065 1354 .075 Bank Sta: Left Right Lengths: Left Channel Right 1339 1354 650 760 575 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 276 .75 Element Vel Head (ft) 0.07 Wt. n-Val. w.s. Elev (ft) 276 .68 Reach Len. (ft) Elev Sta 274 1075 272 ll80 Coef f Contr . .1 Left OB 0 .070 1. 00 51. 65 51. 65 96.24 30.95 1.86 1.67 1525.6 31.47 0.41 s ) 0 .76 62 .98 15.08 Elev Sta 274.2 1339 274.3 1600 Coeff Contr . .1 Left OB 0.070 650.00 Elev 272 274 Expan. . 3 Channel 0.065 1. 00 222.08 222.08 1080.28 35.00 4.86 6.35 17123.9 35.85 1.54 7.49 16.30 1.29 Elev 272.8 274.9 Expan. . 3 Channel 0.065 760.00 Right OB 0.075 1. 00 729. 30 729. 30 ll24.48 532 .24 1.54 1 .37 17824.5 532 .28 0.34 0.52 63.43 16.55 Right OB 0.075 575.00 Crit W.S. (ft) Flow Area (sq ft) 179.91 86.25 961.19 E.G. Slope (ft/ft) 0.002946 Area (sq ft) 179 .91 86.25 961.19 Q Total (cfs) 2301 .00 Flow (cfs) 343.93 304.32 1652.75 Top Width (ft) 574.44 Top Width (ft) 84.08 15.00 475.36 Vel Total (ft/s) 1.87 Avg. Vel. (ft/s) 1.91 3.53 1.72 Max Chl Dpth (ft) 8.18 Hydr. Depth (ft) 2. 14 5.75 2.02 Conv. Total (cfs) 42392.7 Conv. (cfs) 6336.4 5606.7 30449.6 Length Wtd. (ft) 630.04 Wetted Per. (ft) 84.18 17.98 475.40 Min Ch El (ft) 268.50 Shear (lb/sq ft) 0.39 0.88 0.37 Alpha 1.23 Stream Power (lb/ft s) 0.75 3 .11 0.64 Fr ctn Loss (ft) 2.45 Cum Volume (acre-ft) 62.98 16.30 63.41 C & E Loss (ft) 0.01 Cum SA (acres) 15.07 1.29 16.53 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: N.F. Lick Creek REACH: N.F. Main RS: 61960 INPUT Description: Station Elevation Data num= 38 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 725 282 781 281 .3 850 280.4 938 279 .6 973 279.l 1007 278.8 1069 277 .4 1132 277.2 1195 276.8 1221 276.9 1257 276 .9 1320 276 1382 275.1 1445 274 1470 273.1 1508 272 1531 270.5 1567 269.8 1571 266.7 1576 265.3 1577 266 .l 1585 270.8 1625 270.7 1631 270.l 1632 270.2 1645 271.l 1667 271.3 1681 271. 4 1712 272. 7 1736 272 .9 1763 273.1 1839 273.8 1860 273.9 1943 274.2 1957 274.4 2046 275 .l 2053 275.3 2150 278.7 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 725 .07 1567 .065 1585 .075 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1567 1585 650 760 575 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 274.29 Element Left OB Channel Right OB Vel Head (ft) 0.18 Wt. n-Val. 0.070 0.065 0.075 w.s. Elev (ft) 274 .11 Reach Len. (ft) 650.00 760.00 575.00 Crit W.S . (ft) Flow Area (sq ft) 282.02 11 7. 69 495.38 E.G. Slope (ft/ft) 0.005358 Area (sq ft) 282.02 11 7. 69 495.38 Q Total (cfs) 2301.00 Flow (cfs) 740.36 625.04 935.60 Top Width (ft) 479.53 Top Width (ft) 128.32 18.00 333.20 Vel Total (ft/s) 2.57 Avg. Vel. (ft/s) 2.63 5 .31 1. 89 Max Chl Dpth (ft) 8 .81 Hydr. Depth (ft) 2.20 6.54 1.49 Conv. Total (cfs) 31436 .0 Conv. (cfs) 10114 . 7 8539.2 12782.l Length Wtd . (ft) 646.37 Wetted Per. (ft) 128.41 20.81 333.30 Min Ch El (ft) 265.30 Shear (lb/sq ft) 0.73 1. 89 0.50 Alpha 1 . 71 Stream Power (lb/ft s) 1.93 10.05 0.94 Frctn Loss (ft) 1 .15 Cum Volume (acre-ft) 59.53 14.52 53.80 C & E Loss (ft) 0.04 Cum SA (acres) 13 .49 1. 00 11. 20 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: N.F. Main RIVER: N.F. Lick Creek RS: 61200 INPUT Description: Station Elevation Data num= Sta Elev Sta Elev 30 Sta Elev Sta Elev Sta Elev 450 1000 1500 1799 1863 2000 280 273.9 274 262.8 265.9 271. 8 Manning's n Values Sta n Val 450 .07 540 llOO 1600 1804 1878 2100 279 273.9 273.2 262 267 .9 272.9 num= Sta n Val 1794 .065 630 1200 1700 1806 1900 2200 3 Sta 1815 278 273.7 270.3 262.6 268.2 274.2 n Val .075 790 1300 1738 1815 1915 2300 Bank Sta: Left 1794 Right 1815 Lengths: Left Channel Right CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S . Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) 1050 1300 1083.3 Profile #PF 1 273.09 0.04 273.05 0.000884 2301. 00 506 .06 1.42 ll. 05 77392.6 ll18. 09 Element wt . n-Val. Reach Len. (ft) Fl ow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) wetted Per. (ft) 277 274 267.6 267 .5 268.4 275 900 1400 1794 1857 1947 2400 Coeff Contr . .1 Left OB 0.070 1050.00 613. 27 613. 27 848.70 188.73 Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd . (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) 262.00 1. 41 0.70 0.01 Shear (lb/sq ft) Stream Power (lb/ft s) Cum Vo l ume (acre-ft) Cum SA (acres) 1.38 3.25 28545 .5 188.87 0.18 0.25 52.85 11.12 CROSS SECTI ON REACH: N.F. Main RIVER: N.F. Lick Creek RS: 59900 INPUT Description: Station Elevation Data num= Sta Elev Sta Elev 276.3 273.8 272.4 270.9 261. 6 265.5 266.8 542 277.3 624 920 1227 1501 1770 1783 1856 1979 2194 274.l 271. 7 271 . 6 265.2 261.1 266.6 270 .6 274.2 Manning's n Values Sta n Val 542 .07 953 1296 1593 1774 1792 1878 2004 2282 271 275.2 num= Sta n Val 1770 .065 44 Sta 724 1044 1319 1676 1775 1833 1893 2080 2289 3 Sta 1792 Elev 275.4 272 272 .6 268 .6 260.7 265.8 267 272.4 275.4 n Val .07 Sta 731 ll09 1410 1684 1780 1834 1919 2099 2383 Bank Sta: Left 1770 Right 1792 Lengths: Left Channel Right 1083 .3 CROSS SECTI ON OUTPUT E.G . Elev (ft) Vel Head (ft) W.S . Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) 1050 1300 Profile #PF 1 272 . 38 0.03 272.36 0. 0004 71 2301.00 968.60 1.02 12.46 106031.0 1300.00 259.90 Element wt. n-Val . Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) wetted Per. (ft) Shear (lb/sq ft ) Elev 275 .3 271. 9 272 .2 268.4 259.9 265.8 268.2 272.7 277.7 Sta 852 ll36 1487 1719 1782 1840 1925 2181 Coeff Contr. .1 Left OB 0.070 1300. 00 1031.29 1031.29 770 .59 661 .01 0.75 1.56 35508.9 661 .14 0.05 276 274.5 266.8 267 271.1 277.4 Expan. .3 Channel 0.065 1300. 00 187.94 187.94 506.52 21.00 2.70 8.95 17036.5 23.80 0.44 1.17 ll. 85 0.66 Elev 274.6 271. 9 271. 7 266 260.6 264.9 269.5 274.1 Expan. .3 Channel 0.065 1300. 00 224 .52 224 .52 480.67 22.00 2.14 10.21 22149.6 25.05 0.26 Right OB 0.075 1083.30 817.16 817.16 945.78 296.33 1.16 2.76 31810.6 296.69 0.15 0.18 45.14 7.04 Right OB 0.070 1300. 00 993.42 993.42 1049.74 285.59 1. 06 3.48 48372.5 285.95 0.10 Alpha Frctn Loss (ft) C & E Loss (ft) 1. 58 1.18 0.01 Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Warning: Divided flow computed for this cross-section. 0.03 26.89 0.56 5.25 0 .11 22.38 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: AlexBranch RIVER: S .F. LICK CREEK RS: 8867. INPUT Description: us2 of potomic dr culvert Station Elevation Data num= 8 Sta Elev Sta Elev Sta Elev Sta 1000 291.5 1130 290 1158 288 1162 1188 288 1215 290 1250 292 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .1 1158 .05 1215 .1 Bank Sta: Left Right Lengths: Left Channel Right 1158 1215 22 22 22 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 288.67 Element Vel Head (ft) 0.23 Wt. n-Val. w.s. Elev (ft) 288.44 Reach Len. (ft) Crit W.S. (ft) Flow Area (sq ft) E.G. Slope (ft/ft) 0.006532 Area (sq ft) Q Total (cfs) 292.00 Fl ow (cfs) Top Width (ft) 42.04 Top Width (ft) Vel Total (ft/s) 3.80 Avg. Vel. (ft/s) Max Chl Dpth (ft) 3.44 Hydr. Depth (ft) Conv. Total (cfs) 3612.9 Conv. (cfs) Length Wtd. (ft) 22.00 Wetted Per. (ft) Min Ch El (ft) 285.00 Shear (lb/sq ft) Alpha 1.03 Stream Power (l b/ft Frctn Loss (ft) 0.16 Cum Volume (acre-ft) C & E Loss (ft) 0.01 Cum SA (acres) CROSS SECTION RIVER: S.F . LICK CREEK REACH: AlexBranch RS: 8845. INPUT Description: us of potomic dr culvert Station Elevation Data num= 8 Sta Elev Sta Elev Sta Elev Sta 1000 291.5 1130 290 1158 288 1162 1188 288 1215 290 1250 292 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .1 1158 .05 1215 .1 Bank Sta: Left Right Lengths: Left Channel Right 1158 1215 65 79 110 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 288.50 Element Vel Head (ft) 0.29 Wt. n-Val. w.s. Elev (ft) 288.21 Reach Len. (ft) Crit W.S. (ft) Flow Area (sq ft) E.G. Slope (ft/ft) 0.008394 Area (sq ft) Q Total (cfs) 292.00 Flow (cfs) Top Width (ft) 35 .82 Top Width (ft) Elev Sta Elev 286 1180 285 Coe ff Contr. Expan. .1 .3 Left OB Channel Right OB 0.100 0.050 22.00 22.00 22.00 1. 34 75.42 1. 34 75.42 0.58 291.42 6.13 35.91 0.44 3.86 0.22 2.10 7.2 3605.7 6.14 36.97 0.09 0.83 s) 0.04 3.21 4.88 4.23 0.19 0.87 0.81 0.16 Elev Sta Elev 286 1180 285 Coe ff Contr. Expan. .1 .3 Left OB Channel Right OB 0.100 0.050 65.00 79.00 110.00 0.31 67.65 0.31 67.65 0.10 291.90 2.96 32.86 Vel Total (ft/s) 4.30 Avg. Vel. (ft/s) 0 .30 4.31 Max Chl Dpth (ft) 3.21 Hydr. Depth (ft) 0.11 2.06 Conv. Total (cfs) 3187 .2 Conv. (cfs) 1.0 3186.l Length Wtd . (ft) 79.00 Wetted Per. (ft) 2.97 33.91 Min Ch El (ft) 28S.OO Shear (lb/sq ft ) 0 .06 1. OS Alpha 1.01 Stream Power (lb/ft s) 0.02 4.Sl Frctn Loss (ft) 0 .2S Cum Volume (acre-ft) 4.88 4.20 0.19 C & E Loss (ft) 0.06 Cum SA (acres ) 0.86 0.79 0.16 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: AlexBranch RIVER: S.F . LICK CREEK RS: 8766. INPUT Description: ds of potomic culvert Station Elevation Data num= Sta Elev Sta Elev 1000 291.S 1120 290 1270 290 Manning's n Values Sta n Val 1000 .1 131S Sta 1160 292 num= n Val .OS 7 Sta 1160 3 Sta 1210 Elev 288 n Val .1 Sta 1180 Bank Sta: Left 1160 Right 1210 Lengths: Left Channel Right 20 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S . Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) Profile #PF 1 288 .19 0.08 288 .11 0.00161S 292.00 SS.64 2.23 s .11 7266.4 22.00 283.00 1. 00 0.04 0.00 20 22 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) CROSS SECTION REACH: AlexBranch RIVER: S.F. LICK CREEK RS: 8744. INPUT Description: ds 2 Station Elevation of potomic culvert Sta Elev 1000 291.S 1270 290 Data Sta 1120 131S Manning's n Values Sta n Val Sta 1000 .1 1160 Bank Sta: Left Right 1160 1210 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) w.s . Elev (ft) num= 7 Elev Sta Elev 290 1160 288 292 num= 3 n Val Sta n Val .OS 1210 .1 Lengths: Left Channel lSO 208 Profile #PF 1 288.lS Element 0.08 Wt. n-Val . 288.07 Reach Len. Sta 1180 Right 180 (ft) Elev 283 Sta 1210 Coeff Contr. .1 Left OB 0.100 20.00 0.13 0.13 0.01 2.26 0.09 0.06 0.3 2.26 0.01 0.00 4.88 0.86 Elev Sta 283 1210 Coeff Contr. .1 Left OB 0.100 lS0.00 Elev 288 Expan. . 3 Channel o.oso 22.00 130.64 130.64 291.97 S0.00 2.23 2.61 726S.7 Sl.03 0.26 O.S8 4.02 0. 72 Elev 288 Expan. .3 Channel o.oso 208.00 Right OB 0.100 20.00 0.19 0.19 0.02 3.38 0.09 0.06 0.4 3.39 0.01 0.00 0.19 0.16 Right OB 0.100 180 .00 Crit W.S. (ft) Flow Area (sq ft) 0.05 128.69 0.08 E.G. Slope (ft/ft) 0.001698 Area (sq ft) 0.05 128.69 0.08 Q Total (cfs) 292.00 Flow (cfs) 0.00 291. 99 0 .01 Top Width (ft) 53.69 Top Width (ft) 1. 48 50.00 2.21 Vel Total (ft/s) 2.27 Avg. Vel . (ft/s) 0.07 2.27 0.07 Max Chl Dpth (ft) 5.07 Hydr . Depth (ft) 0.04 2.57 0.04 Conv. Total (cfs) 7085.9 Conv. (cfs) 0.1 7085.7 0.1 Length Wtd . (ft) 207.87 Wetted Per. (ft) 1.48 51.03 2.21 Min Ch El (ft) 283 .00 Shear (lb/sq ft) 0.00 0.27 0.00 Alpha 1. 00 Stream Power (lb/ft s) 0 .00 0.61 0.00 Frctn Loss (ft) 0 .13 Cum Volume (acre-ft) 4.88 3.95 0.19 C & E Loss (ft) 0.02 Cum SA (acres) 0.86 0.69 0.15 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1 .4. This may indicate the need for additional cross sections. CROSS SECTION REACH: AlexBranch RIVER: S.F. LICK CREEK RS: 8536. INPUT Description: Station Elevation Data num= 7 Sta Elev Sta Elev Sta Elev Sta 1000 291 1118 290 1190 288 1220 1280286.4562 1315 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .1 1190 .05 1280 .1 Bank Sta: Left Right Lengths: Left Channel Right 1190 1280 190 259 208 CROSS SECTION OUTPUT Profile #PF 1 E .G. Elev (ft) 288.00 Element Vel Head (ft) 0.02 Wt. n -Val . w.s. Elev (ft) 287.98 Reach Len. (ft) Crit W.S. (ft) Flow Area (sq ft) E.G. Slope (ft/ft) 0.000339 Area (sq ft) Q Total (cfs) 292.00 Flow (cfs) Top Width (ft) 104.80 Top Width (ft) Vel Total (ft/s) 1. 07 Avg. Vel. (ft/s) Max Chl Dpth (ft) 6.08 Hydr. Depth (ft) Conv. Total (cfs) 15859.6 Conv. (cfs) Length Wtd . (ft) 256.92 Wetted Per. (ft) Min Ch El (ft) 281.90 Shear (lb/sq ft) Alpha 1.06 Stream Power (lb/ft Frctn Loss (ft) 0.04 Cum Volume (acre-ft) C & E Loss (ft) 0.00 Cum SA (acres) Elev Sta Elev 286 1235 281.9 Coe ff Contr. Expan . .1 .3 Left OB Channel Right OB 0.050 0.100 190.00 259.00 208.00 261.11 11.49 261.11 11.49 289.38 2.62 89.73 15.07 1.11 0.23 2.91 0.76 15717.5 142.l 90.57 15.15 0.06 0.02 s) 0.07 0.00 4.88 3.02 0.17 0.86 0.36 0.12 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: AlexBranch INPUT Description: Station Elevation Sta Elev 1070 289.5 1295 288 Manning's n Values Sta n Val 1070 .1 RIVER: S.F. LICK CREEK RS: 8277. Data Sta 1165 1370 Sta 1211 num= Elev 288 290 num= n Val .05 7 Sta 1195 3 Sta 1295 Elev 286 n Val .1 Bank Sta: Left Right Lengths: Left Channel Sta 1211 Right Elev 284 Coef f Sta 1245 Contr. Elev 281 Expan. 1211 1295 0 0 0 .1 .3 CROSS SECTI ON OUTPUT Profile #PF 1 E.G. Elev (ft) 287.96 El ement Left OB Channel Right OB Vel Head (ft) 0.01 Wt. n-Val. 0.100 0.050 w.s. Elev (ft) 287.95 Reach Len. (ft) 361.00 361.00 361.00 Crit W.S. (ft) Flow Area (sq ft) 75.55 357.49 E.G. Slope (ft/ft) 0.000098 Area (sq ft) 75.55 357.49 Q Total (cfs) 292.00 Flow (cfs) 15.65 276.35 Top Width (ft) 128.81 Top Width (ft) 45.19 83.62 Vel Total (ft/s) 0.67 Avg. Vel. (ft/s) 0.21 0 .77 Max Chl Dpth (ft) 6 .95 Hydr. Depth (ft) 1 .67 4 .28 Conv. Total (cfs) 29426.5 Conv. (cfs) 1576.8 27849.7 Length Wtd. (ft) 361.00 Wetted Per. (ft) 45.38 84.23 Min Ch El (f t) 281.00 Shear (lb/sq ft) 0.01 0.03 Alpha 1.25 Stream Power (lb/ft s) 0.00 0.02 Frctn Loss (ft) 0.15 Cum Volume (acre-ft) 2.54 1. 79 0.06 C & E Loss (ft) 0.00 Cum SA (acres) Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is l ess than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH : westfield RIVER: S.F. LICK CREEK RS: 11228 . INPUT Description: ADD X-SECTION UPSTREAM ON CARROL TRACT Station Elevation Data Sta El ev Sta 1000 300 1035 1200 294 Manning's n Values Sta n Val 1000 .08 1240 Sta 1170 Bank Sta: Lef t 1170 Right 1200 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) num= Elev 298 296 num= n Val .OS 9 Sta 1097 1280 3 Sta 1200 Elev 296 298 n Val .08 Sta 1170 1425 Lengths: Lef t Channel Right 280 250 215 Profile #PF 1 297.79 0.26 297.53 0.004330 1352. 00 221.19 2 .80 5.53 20546 .l 225.61 292.00 2 .12 1.33 0 .02 El ement Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Elev 294 300 Sta 1180 Coeff Contr. .1 Left OB 0.080 250.00 221.35 221. 35 405.59 120 .53 1. 83 1. 84 6163.7 120.58 0.50 0.91 14.58 5.45 Elev 292 Expan . . 3 Channel 0.050 215 .00 135.99 135.99 723 .64 30.00 5.32 4.53 10997.0 30.30 1 .21 6.46 15 . 71 2.84 Right OB 0.080 280 .00 124.83 124.83 222.77 70.66 1 .78 1 .77 3385.3 70.75 0.48 0.85 8.41 4.10 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: S.F. LICK CREEK REACH: westf ield RS: 1097B. INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta 670 300 B65 29B 940 296 970 995 290 lOOB 290 1010 292 1020 1160 29B 1270 300 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 670 .OB 940 .05 1025 .OB Bank Sta: Left Right Lengths: Left Channel Right 940 1025 200 220 220 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 296.44 Element Vel Head (ft) 0.47 Wt. n-Val. w.s. Elev (ft) 295 .96 Reach Len. (ft) Crit W.S. (ft) Flow Area (sq ft) E.G. Slope (ft/ft) O.OOB57B Area (sq ft) Q Total (cfs) 1352.00 Flow (cfs) Top Width (ft) B4 .34 Top Width (ft) Vel Total (ft/s) 5.52 Avg. Vel. (ft/s) Max Chl Dpth (ft) 5 . 96 Hydr. Depth (ft) Conv. Total (cfs) 1459B.O Conv. (cfs) Length Wtd. (ft) 21B.BO Wetted Per. (ft) Min Ch El (ft) 290.00 Shear (lb/sq ft) Alpha l. 00 Stream Power (lb/ft Fr ctn Loss (ft) 1.57 Cum Volume (acre-ft) C & E Loss (ft) 0.01 Cum SA (acres) Elev Sta 294 9B5 294 1025 Coe ff Contr. .1 Left OB 200.00 s) 13.94 5.10 Elev 292 296 Expan. .3 Channel 0.050 220.00 244.B2 244.B2 1352.00 B4.34 5.52 2.90 1459B.O B6 .14 1.52 B.40 14.77 2.55 Right OB 220.00 B.01 3.BB Warning: The energy loss was greater than 1.0 ft (0 .3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: S.F. LICK CREEK REACH: westfield RS: 1075B. INPUT Description: Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 760 29B B90 296 910 294 975 292 990 290 1000 2BB 1005 290 1025 292 1040 294 1100 296 1220 29B Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 760 .OB 975 .05 1025 .OB Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 975 1025 155 130 100 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 294.B6 Element Left OB Channel Right OB Vel Head (ft) 0 .45 Wt. n-Val. O.OBO 0.050 0.0BO w.s. Elev (ft) 294.41 Reach Len. (ft) 155.00 130.00 100.00 Crit W.S. (ft) Flow Area (sq ft) 92. 71 200.66 23.76 E.G. Slope (ft/ft) 0.006043 Area (sq ft) 92. 71 200.66 23.76 Q Total (cfs) 1352.00 Flow (cfs) 162.73 115B. lB 31.09 Top Width (ft) 146.53 Top Width (ft) 69 .13 50.00 27.40 Vel Total (ft/s) 4.26 Avg. Vel. (ft/s) 1.76 5.77 1.31 Max Chl Dpth (ft) 6.41 Hydr. Depth (ft) 1.34 4.01 0.87 Conv. Total (cfs) 17391.4 Conv. (cfs) 2093.2 14898.2 400.0 Length Wtd. (ft) 128.17 Wetted Per . (ft) 69.18 50.82 27 .54 Min Ch El (ft) 288.00 Shear (lb/sq ft) 0.51 1. 49 0.33 Alpha 1.59 Stream Power (lb/ft s) 0.89 8.60 0.43 Frctn Loss (ft) 0.39 Cum Volume (acre-ft) 13.73 13.65 7.95 C & E Loss (ft) 0.08 Cum SA (acres) 4. 94 2.21 3.81 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: S.F. LICK CREEK REACH: west field RS: 10628. INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 790 297.4 865 296 940 294 960 292 968 290 990 288 1010 288 1012 290 1070 292 1095 294 1150 296 1340 298 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 790 .08 968 .05 1012 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 968 1012 80 110 120 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 294 .39 Element Left OB Channel Right OB Vel Head (ft) 0 .19 Wt. n-Val . 0.080 0.050 0.080 w.s . Elev (ft) 294 .21 Reach Len . (ft) 80.00 110. 00 120.00 Crit W.S. (ft) Flow Area (sq ft ) 50.60 249.11 216.77 E.G. Slope (ft/ft) 0.001822 Area (sq ft) 50.60 249 .11 216.77 Q Total (cfs) 1352.00 Flow (cfs) 50.24 990.17 311.59 Top Width (ft) 168.46 Top Width (ft) 35.76 44 .00 88.69 Vel Total (ft/s) 2 .62 Avg . Vel. (ft/s) 0.99 3.97 1 .44 Max Chl Dpth (ft) 6.21 Hydr. Depth (ft) 1.41 5.66 2.44 Conv. Total (cfs) 31670.6 Conv. (cfs) 1176. 9 23194.6 7299 .1 Length Wtd. (ft) 106.06 Wetted Per. (ft) 36 .11 44.92 88.81 Min Ch El (ft) 288.00 Shear (lb/sq ft) 0.16 0.63 0.28 Alpha 1. 76 Stream Power (lb/ft s) 0.16 2.51 0.40 Frctn Loss (ft) 0.24 Cum Volume (acre-ft) 13.47 12 .97 7.68 C & E Loss (ft) 0.01 Cum SA (acres) 4 .76 2.07 3.67 CROSS SECTION RIVER: S.F . LICK CREEK REACH: westfield RS: 10518. INPUT Description: Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 848 294 915 292 990 290 995 286 1002 286 1010 288 1015 290 1025 292 1035 294 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 848 .08 990 .05 1015 .08 Bank Sta: Left Right Lengths : Left Channel Right Coe ff Contr. Expan. 990 1015 150 180 140 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 294.14 Element Left OB Channel Right OB Vel Head (ft) 0.30 Wt. n-Val. 0.080 0.050 0.080 w.s . Elev (ft) 293.85 Reach Len. (ft) 150.00 180.00 140 .00 Crit W.S. (ft) Flow Area (sq ft) 270.66 163.17 37.00 E.G. Slope (ft/ft) 0.002915 Area (sq ft) 270 .66 163.17 37.00 Q Total (cf s) 1352.00 Flow (cfs) 427 .48 867.89 56.64 Top Width (ft) 181.11 Top Width (ft) 136. 87 25.00 19.23 Vel Total (ft/s) 2.87 Avg. Vel. (ft/s) 1. 58 5.32 1.53 Max Chl Dpth (ft) 7.85 Hydr. Depth (ft) 1. 98 6.53 1.92 Conv. Total (cfs) 25042.3 Conv. (cfs) 7917.9 16075.4 1049.0 Length Wtd . (ft) 168.37 Wetted Per. (ft) 136.93 27.03 1 9.62 Min Ch El (ft) 286.00 Shear (lb/sq ft) 0 .36 1.10 0.34 Alpha 2.31 Stream Power (l b/ft s) 0.57 5.84 0.53 Frctn Loss (ft) 0.56 Cum Volume (acre-ft) 13.18 12.45 7.33 C & E Loss (ft) 0.00 Cum SA (acres) 4.60 1. 99 3.52 CROSS SECTION RIVER: S.F. LICK CREEK REACH: west field RS: 10338. INPUT Description: Station Elevation Data num= 10 Sta El ev Sta Elev Sta Elev Sta El ev Sta Elev 800 294 888 292 985 290 990 288 995 286 1003 286 1010 290 1035 292 1050 294 1320 296 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 800 .08 985 .05 1010 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 985 1010 140 130 110 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 293.58 Element Left OB Channel Right OB Vel Head (ft) 0.33 Wt. n-Val. 0.080 0 .050 0.080 w.s. Elev (ft) 293.25 Reach Len. (f t) 140.00 130. 00 110. 00 Crit W.S . (f t) Flow Area (sq ft) 252.90 147 .30 62.17 E.G. Slope (ft/ft) 0.003803 Area (sq ft) 252 .90 147.30 62.17 Q Total (cfs) 1352. 00 Flow (cfs) 406.56 840.08 105.36 Top Width (ft) 211.47 Top Width (ft) 152.08 25.00 34.39 Vel Total (ft/s ) 2.92 Avg. Vel. (ft/s) 1. 61 5.70 1.69 Max Chl Dpth (ft) 7.25 Hydr. Depth (ft) 1.66 5.89 1. 81 Conv. Total (cfs) 21922.3 Conv. (cfs) 6592.3 13621.7 1708.4 Length Wtd . (ft) 129.81 Wetted Per. (ft) 152.11 26.83 34.55 Min Ch El (ft) 286.00 Shear (lb/sq ft) 0.39 1. 30 0.43 Alpha 2.48 Stream Power (lb/ft s) 0 .63 7.43 0. 72 Frctn Loss (ft) 0 .80 Cum Volume (acre-ft) 12.28 11 . 81 7.17 C & E Loss (ft) 0.07 Cum SA (acres) 4 .10 1. 88 3.44 Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance r atio (upstr eam conveyance divided by downstream conveyance) is l ess than 0.7 or greater than 1.4. This may indicate the need for addi tional cross sections. CROSS SECTION REACH: west field INPUT Description : Station Elevation Sta Elev 890 294 1005 286 1290 296 Manning 's n Values Sta n Val 890 . 08 RIVER: S.F. LI CK RS: 10208. Data num= Sta Elev 940 292 1010 288 num= Sta n Val 990 . 05 11 Sta 975 1030 3 Sta 1010 CREEK Elev 290 290 n Val .08 Sta 990 1055 El ev Sta Elev 288 995 286 292 1150 294 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 990 1010 50 70 105 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 292.71 Element Left OB Channel Right OB Vel Head (ft) 1. 02 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 291 .70 Reach Len. (ft) 50 .00 70.00 105.00 Crit W.S. (ft) Flow Area (sq ft) 65.69 103 .96 71. 97 E.G. Slope (ft/ft) 0. 011614 Area (sq ft) 65.69 103.96 71.97 Q Total (cfs) 1352.00 Flow (cfs) 169.48 974 .19 208.33 Top Width (ft) 105.94 Top Width (ft) 44.71 20.00 41.22 Vel Total (ft/s) 5 .60 Avg. Vel. (ft/s) 2.58 9.37 2.89 Max Chl Dpth (ft) 5.70 Hydr. Depth (ft) 1. 47 5.20 1. 75 Conv. Total (cfs) 12545.4 Conv. (cfs) 1572.6 9039.7 1933.l Length Wtd. (ft) 71. 25 Wetted Per. (ft) 44.89 20.77 41. 39 Min Ch El (ft) 286.00 Shear (lb/sq ft) 1. 06 3.63 1.26 Alpha 2 .09 Stream Power (lb/ft s) 2.74 34.01 3.65 Fr ctn Loss (ft) 0.14 Cum Volume (acre-ft) 11. 77 11 .44 7.00 C & E Loss (ft) 0.28 Cum SA (acres) 3.78 1. 82 3.34 Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: westfield RIVER: S.F. LICK CREEK RS: 10138. INPUT Description: Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta 850 294 905 292 938 290 960 1005 286 1050 288 1060 290 1080 1335 296 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 850 .08 960 .05 1050 .08 Bank Sta: Left Right Lengths: Left Channel Right 960 1050 60 80 60 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 292.29 Element Vel Head (ft) 0.09 Wt. n-Val. w.s. Elev (ft) 292.20 Reach Len. (ft) Crit W.S . (ft) Flow Area (sq ft) E.G. Slope (ft/ft) 0.000812 Area (sq ft) Q Total (cfs) 1352 .00 Flow (cfs) Top Width (ft) 197.03 Top Width (ft) Vel Total (ft/s) 2 .09 Avg. Vel. (ft/s) Max Chl Dpth (ft) 6.20 Hydr. Depth (ft) Conv. Total (cfs) 47432.2 Conv. (cfs) Length Wtd. (ft) 75.91 Wetted Per. (ft) Min Ch El (ft) 286.00 Shear (lb/sq ft) Alpha 1.39 Stream Power (lb/ft Frctn Loss (ft) 0.15 Cum Volume (acre-ft) C & E Loss (ft) 0 .11 Cum SA (acres) Elev Sta Elev 288 995 286 292 1250 294 Coef f Contr . Expan. .l . 3 Left OB Channel Right OB 0.080 0.050 0.080 60.00 80.00 60.00 110. 30 477 .62 57 .50 110 . 30 477.62 57 .50 87 .11 1230.04 34.85 60.39 90.00 46 .65 0.79 2.58 0.61 1.83 5.31 1. 23 3056.0 43153.4 1222.8 60.54 90.10 46.94 0.09 0.27 0.06 s ) 0 .07 0.69 0.04 11. 66 10.97 6.84 3. 72 1.73 3.24 Warning : The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: S .F. LICK CREEK REACH: westfield RS: 10058. INPUT Description: Station Elevation Data num= 15 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 750 294 855 292 920 290 990 288 994 286 998 284 1005 284 1008 286 1010 290 1020 292 1045 293 .5 1070 292 1150 292 1240 294 1340 296 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 750 .08 994 .05 1008 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 994 1008 40 40 40 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 292 .03 Element Left OB Channel Right OB Vel Head (ft) 1.16 Wt . n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 290.87 Reach Len. (ft) 40.00 40.00 40.00 Crit W.S. (ft) 290.87 Flow Area (sq ft) 158.23 89.12 7.60 E.G. Slope (ft/ft) 0. 011320 Area (sq ft) 158 .23 89.12 7.60 Q Total (cfs) 1352. 00 Flow (cfs) 417 .28 921. 1 7 13 .55 Top Width (ft) 122.46 Top Width (ft) 102.13 14.00 6 .33 Vel Total (ft/s) 5.30 Avg. Vel. (ft/s) 2.64 10.34 1. 78 Max Chl Dpth (ft) 6.87 Hydr. Depth (ft) 1. 55 6.37 1. 20 Conv. Total (cfs) 12707.3 Conv. (cfs) 3922.0 8658.0 127.3 Length Wtd. (ft) 40.00 Wetted Per. (ft) 102.65 15.08 8.89 Min Ch El (ft) 284.00 Shear (lb/sq ft) 1.09 4.18 0 .60 Alpha 2.67 Stream Power (lb/ft s) 2.87 43 .18 1. 08 Frctn Loss (ft) 0.20 Cum Volume (acre-ft) 11 .48 10 .45 6.80 C & E Loss (ft) 0.28 Cum SA (acres) 3.61 1. 63 3.20 Warning: The energy equation could not be balanced within the specified number of iterations. The program selected the water surface that had the least amount of error between computed and assumed values . Warning: The velocity head has changed by more than 0.5 ft (0 .15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. CROSS SECTION RIVER: S.F. LICK CREEK REACH: westf ield RS: 10018. INPUT Description: Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 850 294 880 292 898 290 990 288 995 284 1005 284 1010 286 1015 288 1110 290 1220 292 1310 294 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 850 .08 990 .05 1015 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 990 1015 200 330 160 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 291.34 Element Left OB Channel Right OB Vel Head (ft) 0.22 Wt. n-Val. 0.080 0.050 0.080 w.s . Elev (ft) 291.12 Reach Len. (ft) 200.00 330.00 160.00 Crit W.S. (ft) Flow Area (sq ft) 200.38 147.93 235.43 E.G. Slope (ft/ft) 0.002883 Area (sq ft) 200.38 147.93 235.43 Q Total (cfs) 1352.00 Flow (cfs) 313.20 730.48 308.32 Top Width (ft) 283 .49 Top Width (ft) 102.05 25.00 156.44 Vel Total (ft/s) 2 .32 Avg. Vel. (ft/s) 1. 56 4. 94 1 .31 Max Chl Dpth (ft) 7.12 Hydr. Depth (ft) 1.96 5.92 1.50 Conv. Total (cfs) 25178.9 Conv. (cfs) 5832.9 13604.l 5742.0 Length Wtd. (ft) 265.88 Wetted Per. (ft) 102.14 27.17 156.47 Min Ch El (ft) 284.00 Shear (lb/sq ft) 0.35 0.98 0.27 Alpha 2.63 Stream Power (l b/ft s) 0.55 4 .84 0.35 Fr ctn Loss (ft) 0.96 Cum Volume (acre-ft) 11. 32 10.34 6.69 C & E Loss (ft) 0 .02 Cum SA (acres) 3.52 1 .61 3.13 CROSS SECTION RIVER: S.F. LICK CREEK REACH: westf ield RS: 9688. INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 580 294 950 292 970 290 980 288 990 286 995 284 1010 284 1015 286 1070 288 1090 290 1120 292 1310 294 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 580 .08 990 .05 1015 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 990 1015 80 120 140 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 290.36 Element: Left OB Channel Right OB Vel Head (ft) 0. 41 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 289.95 Reach Len. (ft) 80.00 120.00 140.00 Crit W.S. (ft) Flow Area (sq ft) 38.99 138.73 181.19 E.G. Slope (ft/ft) 0.004631 Area (sq ft) 38.99 138.73 181.19 Q Total (cfs) 1352.00 Fl ow (cfs) 76.55 861.73 413.72 Top Width (ft) 119 . 24 Top Width (ft) 19.75 25.00 74.49 Vel Total (ft/s) 3. 77 Avg. Vel. (ft/s) 1. 96 6.21 2.28 Max Chl Dpth (ft) 5.95 Hydr . Depth (ft) 1. 97 5.55 2.43 Conv. Total (cfs) 19867.7 Conv. (cfs} 1124. 9 12663.l 6079.7 Length Wtd. (ft) 120.09 Wetted Per. (ft) 20. 14 25.77 74.62 Min Ch El (ft) 284.00 Shear (lb/sq ft) 0.56 1. 56 0.70 Alpha 1. 86 Stream Power (lb/ft s) 1.10 9.67 1. 60 Frctn Loss (ft) 0.64 Cum Volume (acre-ft) 10.77 9.25 5.92 C & E Loss (ft) 0.01 Cum SA (acres) 3.24 1. 43 2.70 CROSS SECTION RIVER: S.F. LICK CREEK REACH: westfield RS: 9568. INPUT Description: Station Elevation Data num= 10 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 790 292 910 290 950 288 985 286 990 284 1010 284 1020 286 1040 288 1050 290 1070 292 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 790 .08 985 .05 1020 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 985 1020 120 110 160 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 289.71 El ement Left OB Channel Right OB Vel Head (ft) 0.53 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 289.18 Reach Len . (ft) 120.00 llO . 00 160.00 Crit W.S. (ft) Fl ow Area (sq ft) 90.48 166.45 47.19 E.G. Slope (ft/ft) 0.006054 Area (sq ft) 90.48 166.45 47.19 Q Total (cfs) 1352. 00 Flow (cfs) 174.33 1076 .54 101.13 Top Width (ft) ll9. 61 Top Width (ft) 58.69 35.00 25.92 Vel Total (ft/s) 4.45 Avg. Vel. (ft/s) 1.93 6.47 2.14 Max Chl Dpth (ft) 5.18 Hydr . Depth (ft) 1.54 4.76 1. 82 Conv. Total (cfs) 17376.2 Conv. (cfs) 2240 .6 13835.9 1299.7 Length Wtd. (ft) 114.57 Wetted Per. (ft) 58.77 35.58 26.14 Min Ch El (ft) 284.00 Shear (lb /sq ft) 0.58 1. 77 0.68 Alpha 1 .73 Stream Power (lb/ft s) 1.12 11. 43 1.46 Frctn Loss (ft) 0.41 Cum Volume (acre-ft) 10.65 8.83 5 .55 C & E Loss (ft) 0. ll Cum SA (acres) 3.17 1.34 2.54 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1 .4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: S.F . LICK CREEK REACH: west field RS: 9458. INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 808 292 860 290 879 288 900 286 939 285.7 968 286 990 284 1000 283 1005 284 1018 286 1025 288 1055 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 808 .08 968 .05 1018 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 968 1018 80 ll5 96 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 289 .20 Element Left OB Channel Right OB Vel Head (ft) 0 .17 Wt. n-Val. 0.080 0.050 0 .080 w.s. Elev (ft) 289.03 Reach Len. (ft) 80.00 ll5. 00 96.00 Crit W.S. (ft) Flow Area (sq ft) 263.49 223.79 22.07 E.G. Slope (ft/ft) 0.002369 Area (sq ft) 263.49 223 .79 22.07 Q Total (cfs) 1352. 00 Flow (cfs) 457.82 874.60 19.58 Top Width (ft) 171.13 Top Width (ft) 98.74 50 .00 22.39 Vel Total (ft/s) 2.65 Avg. Vel. (ft/s) 1. 74 3.91 0.89 Max Chl Dpth (ft) 6.03 Hydr. Depth (ft) 2.67 4.48 0.99 Conv. Total (cfs) 27776.0 Conv. (cfs) 9405.5 17968.2 402.3 Length Wtd. (ft) 107.93 Wetted Per. (ft) 98.90 50 .39 22.70 Min Ch El (ft) 283.00 Shear (lb/sq ft) 0.39 0.66 0.14 Alpha 1. 55 Stream Power (lb/ft s) 0.68 2.57 0.13 Frctn Loss (ft ) 0.16 Cum Volume (acre-ft) 10.16 8.34 5.43 C & E Loss (ft) 0.03 Cum SA (acres) 2.95 1.24 2.45 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4 . This may indicate the need for additional cross sections. CROSS SECTION REACH : westfield INPUT Description: START RIVER: S.F. LICK CREEK RS: 9343. MORRISON hYDROLOGY STUDY x-section 8 Station Elevation Data Sta Elev Sta 798 292 898 988 284 1000 1140 290 1219 Manning's n Values Sta n Val Sta 798 .08 928 Bank Sta: Left 928 Right 1053 CROSS SECTION OUTPUT E.G. Elev (ft ) Vel Head (ft) W.S. Elev (ft ) Crit W.S. (ft ) E.G. Slope (ft/ft ) Q Total (cfs) Top Width (ft ) Vel Total (ft/s ) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd . (ft) Min Ch El (ft ) Alpha Frctn Loss (ft ) C & E Loss (ft ) num= 12 Elev Sta Elev Sta 290 914 288 928 283 1006 284 1053 291 .4 num= 3 n Val Sta n Val .OS 1053 .08 Lengths: Left Channel Right 210 270 256 Profile #PF 1 289.01 0.08 288 .92 0 .001049 1352.00 218.28 2.07 5.92 41739.4 252.29 283.00 1. 28 0.25 0.00 Element Wt . n-Val. Reach Len. (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per . (ft) Shear (lb/sq ft) Stream Power (lb/ft s ) Cum Volume (acre-ft) Cum SA (acres) CROSS SECTION REACH: westfield RIVER: S .F . LICK CREEK RS: 9088. INPUT Description: x-section from city topo by JST on 3/16/00 Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta 1000 292 1195 290 1218 288 1248 1345 282 1367 284 1420 286 1442 1885 292 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .08 1323 .05 1367 .08 Bank Sta : Left Right Lengths: Left Channel Right 1323 1367 345 338 225 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 288.75 Element Vel Head (ft) 0.08 Wt. n-Val. w.s. Elev (ft) 288 .67 Reach Len. (ft) Crit w.s. (ft) Flow Area (sq ft ) E.G. Slope (ft/ft ) 0.000955 Area (sq ft) Elev Sta 286 956 286 1112 Coeff Contr. .1 Left OB 0.080 270 .00 30.30 30.30 22 .87 21 .37 0 .75 1.42 705.9 21 .57 0.09 0.07 9.89 2.84 El ev Sta 286 1323 288 1532 Coef f Contr. .1 Left OB 0.080 345.00 328 .24 328.24 Elev 285.5 288 Expan. .3 Channel 0.050 256.00 504 .22 504 .22 1228.56 125 .00 2.44 4 .03 37928.6 125.21 0.26 0.64 7.38 1. 00 Elev 284 290 Expan. . 3 Channel 0.050 338.00 249.60 249.60 Right OB 0 .080 210.00 119. 33 119. 33 100.57 71. 90 0.84 1. 66 3104.9 71. 97 0 .11 0 .09 5.27 2 .35 Right OB 0.080 225.00 241. 63 241.63 Q Total (cfs) 1352.00 Flow (cfs) 383.84 727.05 241.11 Top Width (ft) 262.01 Top Width (ft) 112.74 44.00 105.27 Vel Total (ft/s) 1.65 Avg. Vel. (ft/s) 1.17 2.91 1. 00 Max Chl Dpth (ft) 6.67 Hydr. Depth (ft) 2.91 5.67 2.30 Conv. Total (cfs) 43753.8 Conv. (cfs) 12422.0 23529.0 7802.9 Length Wtd. (ft) 300.17 Wetted Per. (ft) 112.86 44.18 105 .41 Min Ch El (ft) 282.00 Shear (lb/sq ft ) 0.17 0.34 0.14 Alpha 1. 88 Stream Power (lb/ft s) 0.20 0.98 0.14 Frctn Loss (ft) 0.39 Cum Volume (acre-ft) 8.78 5.17 4.40 C & E Loss (ft) 0.01 Cum SA (acres) 2.42 0.51 1.92 CROSS SECTION RIVER: S .F . LICK CREEK REACH: westf ield RS: 8750. INPUT Description: us of property line x-section from Alexandria Subd by McClure Station Elevation Data num= 14 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 632 292 885 290 966 288 980 286 989 284 998 282 1000 281 1005 281 1012 282 1034 284 1114 286 1215 288 1332 290 1400 292 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 632 .08 989 .05 1012 .08 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 989 1012 380 396 380 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 288.36 Element Left OB Channel Right OB Vel Head (ft) 0.14 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 288.21 Reach Len. (ft) 380.00 396.00 380.00 Crit W.S. (ft) Flow Area (sq ft) 46.79 143 .38 495.37 E.G . Slope (ft/ft) 0.001859 Area (sq ft) 46.79 143.38 495.37 Q Total (cfs) 1352. 00 Flow (cfs) 48.31 612.89 690.80 Top Width (ft) 270.00 Top Width (ft ) 31 .59 23.00 215 .41 Vel Total (ft/s) 1.97 Avg. Vel. (ft/s) 1.03 4.27 1.39 Max Chl Dpth (ft) 7.21 Hydr. Depth (ft) 1.48 6.23 2.30 Conv. Total (cfs) 31360.8 Conv. (cfs) 1120. 6 14216.4 16023.8 Length Wtd. (ft) 390.86 Wetted Per. (ft) 31 .95 23.53 215 .55 Min Ch El (ft) 281.00 Shear (lb/sq ft) 0.17 0. 71 0. 27 Alpha 2 .39 Stream Power (lb/ft s) 0.18 3.02 0.37 Frctn Loss (ft) 0.35 Cum Volume (acre-ft) 7.29 3.64 2.50 C & E Loss (ft) 0.03 Cum SA (acres) 1.85 0.25 1 .09 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: westfield INPUT RIVER: S.F. LICK CREEK RS: 8354. Description: x-section from Alexandria Subd by McClure Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta 837 290 1000 288 1105 286 1140 1203 281 1210 282 1220 282.5 1250 1320 288 1470 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Va l 837 .08 1140 .05 1270 .08 Bank Sta: Left Right Lengths: Left Channel Right 1140 1270 0 0 0 El ev Sta Elev 284 1190 282 284 1270 286 Coef f Contr. Expan. .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 287.98 El ement Left OB Channel Right OB Vel Head (ft) 0.05 Wt. n-Val . 0.080 0.050 0.080 w.s. Elev (ft) 287.93 Reach Len. (ft) 284.00 284.00 284.00 Crit W.S. (ft) Flow Area (sq ft) 200.07 630.66 46.47 E.G. Slope (ft/ft) 0.000520 Area (sq ft) 200.07 630.66 46. 47 Q Total (cf s) 1352.00 Flow (cfs) 109.49 1223.31 19.20 Top Width (ft) 314.43 Top Width (ft) 136.23 130. 00 48.20 Vel Total (ft/s) 1.54 Avg. Vel. (ft/s) 0.55 1. 94 0.41 Max Chl Dpth (ft) 6.93 Hydr. Depth (ft) 1. 47 4.85 0.96 Conv. Total (cfs) 59269.0 Conv. (cfs) 4799.8 53627.3 841.9 Length Wtd. (ft) 284.00 Wetted Per. (f t) 136.30 130.30 48 .24 Min Ch El (ft) 281 .00 Shear (lb/sq ft) 0 .05 0.16 0.03 Alpha 1 .44 Stream Power (lb/ft s) 0.03 0 .30 0.01 Frctn Loss (ft ) 0.17 Cum Volume (acre-ft) 2. 40 2.30 0.20 C & E Loss (ft) 0 .01 Cum SA (acres) CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 7993. INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 864 290 990 288 1105 287.l 1210 286 1230 284 1410 282 1413 281 1420 282 1435 284 1441 286 1480 288 1533 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 864 .08 1410 .05 1441 .08 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 1410 1441 120 178 175 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 287.81 Element Left OB Channel Right OB Vel Head (ft) 0.03 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 287.78 Reach Len. (ft) 120.00 178 .00 175.00 Crit W.S. (ft) Flow Area (sq ft) 1074.32 151.15 30.86 E .G. Slope (ft/ft) 0.000667 Area (sq ft) 1074 .32 151.15 30.86 Q Total (cfs) 1352.00 Flow (cfs) 1009.57 328 .75 13.68 Top Width (ft) 457.46 Top Width (ft) 391 .77 31 .00 34.69 Vel Total (f t/s) 1. 08 Avg. Vel. (f t/s) 0.94 2.17 0.44 Max Chl Dpth (ft) 6.78 Hydr. Depth (ft) 2.74 4.88 0.89 Conv. Total (cfs) 52343.5 Conv. (cfs) 39086.0 12727.8 529.7 Length Wtd. (ft) 133 .84 Wetted Per. (ft) 391.89 31.69 34.74 Min Ch El (ft) 281.00 Shear (lb/sq ft) 0 .11 0.20 0.04 Alpha 1.56 Stream Power (lb/ft s) 0 .11 0.43 0.02 Frctn Loss (ft) 0.10 Cum Volume (acre-ft) 77.14 49.23 67.26 C & E Loss (ft) 0.00 Cum SA (acres) 27.43 6.00 21 .27 CROSS SECTION RI VER: S.F. LICK CREEK REACH: S.F. Main RS: 7815. INPUT Description : Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 872 290 985 288 1075 287.2 1250 286 1350 284 1405 282.7 1470 282 1475 281 1520 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 872 .08 1470 .05 1520 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1470 1520 90 203 175 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 287.70 Element Left OB Channel Right OB Vel Head (ft) 0.03 Wt. n-Val. 0.080 0.050 w.s . Elev (ft) 287.67 Reach Len. (ft) 90.00 203.00 175.00 Crit W.S. (ft) Flow Area (sq ft) 1052.29 142.26 E.G. Slope (ft/ft) 0.000923 Area (sq ft) 1052.29 142.26 Q Total (cfs) 1352.00 Flow (cfs) 1048.37 303.63 Top Width (ft) 486.81 Top Width (ft) 448.43 38.37 Vel Total (ft/s) 1.13 Avg. Vel. (ft/s) 1. 00 2 .13 Max Chl Dpth (ft) 6.67 Hydr. Depth (ft) 2.35 3. 71 Conv. Total (cfs) 44507.7 Conv. (cfs) 34512.3 9995.4 Length Wtd. (ft) 134.73 Wetted Per. (ft) 448.48 39 .13 Min Ch El (ft) 281.00 Shear (lb/sq ft ) 0.14 0.21 Alpha 1. 40 Stream Power (lb/ft s) 0 .13 0. 45 Fr ctn Loss (ft) 0.13 Cum Volume (acre-ft) 74.21 48.63 67.19 C & E Loss (ft) 0.00 Cum SA (acres) 26.27 5.86 21.20 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 7612. INPUT Description: Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 897 290 1055 288 1210 286 1270 284 1288 282 1315 282 1330 281 1335 282 1410 284 1430 286 1540 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 897 .OB 1315 .OS 1335 .08 Bank Sta: Left Right Lengths : Left Channel Right Coef f Contr. Expan. 1315 1335 135 177 135 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 287.57 Element Left OB Channel Right OB Vel Head (ft) 0.06 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 287.51 Reach Len. (ft) 135.00 177.00 135. 00 Crit W.S. (ft) Flow Area (sq ft) 469.98 120.30 420.47 E.G. Slope (ft/ft) 0.001005 Area (sq ft) 469.98 120.30 420.47 Q Total (cfs ) 1352.00 Flow (cfs) 455.49 373.18 523.32 Top Width (ft) 379.06 Top Width (ft) 222.40 20.00 136. 66 Vel Total (ft/s) 1 .34 Avg. Vel. (ft/s) 0.97 3.10 1.24 Max Chl Dpth (ft) 6.51 Hydr. Depth (ft) 2 .11 6.01 3.08 Conv. Total (cfs) 42649.3 Conv. (cfs) 14368.7 11772 .1 16508.4 Length Wtd . (ft) 145.96 Wetted Per. (ft) 222.56 20.13 136. 81 Min Ch El (ft ) 281.00 Shear (lb/sq ft) 0.13 0.37 0.19 Alpha 2 .00 Stream Power (lb/ft s) 0.13 1.16 0.24 Frctn Loss (ft) 0.12 Cum Volume (acre-ft) 72. 64 48.02 66.35 C & E Loss (ft) 0.01 Cum SA (acres) 25.58 5.72 20.93 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S .F . Main RS: 7435. INPUT Description: Station Elevation Data num= 8 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 911 290 1075 288 1216 286 1235 279 .9 1245 282 1415 284 1520 288 1636 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 911 .08 1216 Bank Sta: Left 1216 Right 1245 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) .05 1245 .08 Lengths: Left Channel Right 200 200 298 Profile #PF 1 287.45 0.03 287.41 0.000665 1352 .00 388.18 1.20 7.51 52438.4 258 .56 279.90 1.45 0.10 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft ) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Coeff Contr. .1 Left OB 0.080 200.00 70.35 70.35 26.72 99.60 0.38 0. 71 1036.4 99.61 0.03 0.01 71. 80 25.08 Expan. . 3 Channel 0.050 298.00 14 9. 42 14 9. 42 332.62 29.00 2.23 5.15 12901.0 30.17 0.21 0.46 47.47 5.62 Right OB 0.080 200.00 903.03 903.03 992.66 259 .58 1 .10 3.48 38501.l 259.66 0.14 0.16 64 .30 20.31 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 7137. INPUT Description: Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta 890 290 1090 288 1265 286 1315 1418 280 1430 279 1438 280 1462 1820 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 890 .08 1315 .04 1462 .08 Bank Sta: Left Right Lengths: Left Channel Right 1315 1462 121 121 121 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 287 .3 5 Element Vel Head (ft) 0.04 Wt. n-Val. w.s. Elev (ft) 287.31 Reach Len. (ft) Crit W.S. (ft) Flow Area (sq ft) E.G. Slope (ft/ft) 0.000238 Area (sq ft) Q Total (cfs) 1352.00 Flow (cfs) Top Width (ft) 375.19 Top Width (ft) Vel Total (ft/s) 1.37 Avg. Vel. (ft/s) Max Chl Dpth (ft) 8.31 Hydr. Depth (ft) Conv. Total (cfs) 87582.2 Conv. (cfs) Length Wtd. (ft) 121.00 Wetted Per. (ft) Min Ch El (ft) 279.00 Shear (lb/sq ft) Alpha 1.46 Stream Power (lb/ft Frctn Loss (ft) 0.02 Cum Volume (acre-ft) C & E Loss (ft) 0.00 Cum SA (acres) CROSS SECTION REACH: S.F. Main RIVER: S.F. LICK CREEK RS: 6825. INPUT Description: 65' Up Stream of Alex. Ave. Box Culvert Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 284 1392 282 286 1560 288 Coe ff Contr. Expan. .1 .3 Left OB Channel Right OB 0.080 0.040 0.080 121.00 121.00 121. 00 189.83 754.90 41.75 189.83 754.90 41.75 59.94 1283.06 9.01 164.23 147.00 63.97 0.32 1. 70 0.22 1.16 5.14 0.65 3882.7 83116. 0 583.5 164.27 147.95 63.98 0.02 0.08 0.01 s) 0.01 0 .13 0.00 71. 21 44.38 62 .13 24.48 5.02 19 .57 Elev Sta Elev 352 290 552 288 761 286 811 285 919 283 965 285 980 278 1005 278 1042 287 1185 288 1435 290 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 352 .08 965 .03 1042 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 965 1042 41 41 41 .l .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 287.32 Element Left OB Channel Right OB Vel Head (ft) 0.06 Wt. n-Val. 0.080 0.030 0.080 w.s. Elev (ft) 287.26 Reach Len. (ft) 41.00 41.00 41.00 Crit W.S . (ft) Flow Area (sq ft) 673.13 494.05 4.85 E.G. Slope (ft/ft) 0.000174 Area (sq ft) 673.13 494.05 4.85 Q Total (cfs) 1352. 00 Flow (cfs) 262.13 1089.57 0.31 Top Width (ft) 449.95 Top Width (ft) 335. 71 77.00 37.24 Vel Total (ft/s) 1.15 Avg. Vel. (ft/s) 0.39 2.21 0.06 Max Chl Dpth (ft) 9.26 Hydr. Depth (ft) 2.01 6.42 0.13 Conv . Total (cfs) 102523 .8 Conv. (cfs) 19877.2 82623.4 23.1 Length Wtd . (ft) 41.00 Wetted Per. (ft) 335.79 79.63 37.24 Min Ch El (ft) 278.00 Shear (lb/sq ft) 0.02 0.07 0.00 Alpha 2.97 Stream Power (lb/ft s) 0.01 0.15 0.00 Frctn Loss (ft) 0.00 Cum Volume (acre-ft) 70.01 42.64 62.06 C & E Loss (ft) 0.01 Cum SA (acres) 23.78 4.71 19.43 Warning : The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: S.F. Main INPUT RIVER: S.F. LICK CREEK RS: 6784. Description: 25' Up Stream from Face of Alex. Ave Box Culvert Station Elevation Data Sta Elev 346 290 917 283 1011. 77 278.72 Manning's n Values Sta n Val 346 . 08 Sta 416 961 1047 Sta 980.16 Bank Sta: Left Right 980.16 1011. 77 Ineffective Flow num= Sta L Sta R Elev 346 980.16 286 num= 14 Elev Sta 288 616 285 980.16 287 1077 num= 3 n Val Sta .014 1011.77 Lengths: Left 24 2 Sta L Sta R 1011. 77 1257 Elev 287 278.72 288 n Val .08 Channel 24 Elev 286 Sta 719 980 .66 1257 Right 24 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 287.31 Element Vel Head (ft) 0 .17 Wt. n-Val. w.s. Elev (ft) 287.13 Reach Len. (ft) Crit W.S. (ft) 281.58 Flow Area (sq ft) E.G. Slope (ft/ft) 0.000065 Area (sq ft) Q Total (cfs) 1352.00 Flow (cfs) Top Width (ft) 461.46 Top Width (ft) Vel Total (ft/s) 1. 07 Avg. Vel. (ft/s) Max Chl Dpth (ft) 9.41 Hydr. Depth (ft) Conv. Total (cfs) 168045.0 Conv. (cfs) Length Wtd. (ft) 24.00 Wetted Per. (ft) Min Ch El (ft) 277.72 Shear (lb/sq ft) Alpha 9.70 Stream Power (lb/ft Frctn Loss (ft) 0.00 Cum Volume (acre-ft ) C & E Loss (ft) 0.09 Cum SA (acres) Elev Sta 286 796 277.72 1011 . 27 s) 289 Coeff Contr. . 3 Left OB 0.080 24 .00 810.47 810.47 196.65 390 .65 0.24 2.07 24442.4 391 .73 0 .01 0.00 69.31 23.44 Elev 285 277.72 Expan. . 5 Channel 0.014 24 .00 297.03 297.03 1100. 92 31.61 3. 71 9. 40 136837.9 32.85 0.04 0.14 42.27 4.66 Right OB 0.080 24.00 150.78 150.78 54 .43 39. 20 0.36 3 .85 6764.7 40.17 0.02 0.01 61.99 19 .39 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4 . This may indicate the need for additional cross sections. CROSS SECTION REACH: S.F. Main RIVER: S.F. LICK CREEK RS: 6762. INPUT Description: Up Stream from Face of Alex. Station Elevation Data Sta Elev Sta 350 290 425 980.66 277.68 1003.25 Manning's n Values Sta n Val 350 . 08 Sta 980.16 num= 10 Elev Sta 288 625 277.68 1003.75 num= 3 n Val Sta . 014 1003. 75 Ave Box Elev 286.5 285 n Val .08 Bank Sta: Left Right 980.16 1003.75 Lengths: Left Channel Ineffective Flow Sta L Sta R 350 980.16 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) num= 2 Elev Sta L 286 1003.75 64 64 Sta R 1072 Elev 286 Profile #PF 1 287.22 Element 0 .46 Wt. n-Val . Culvert Sta 684 1035 Right 64 W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) 286.75 Reach Len. (ft) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha 282.45 0.000293 1352. 00 440.02 2 .11 9.07 78954.6 64. 00 277.68 6.67 Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg . Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Elev Sta 286 980.16 287 1072 Coeff Contr. .3 Left OB 0.080 64.00 405.42 405.42 132.54 389.03 0.33 1.04 7740.3 389.03 0.02 0.01 Frctn Loss (ft) C & E Loss (ft) Cum Volume (acre-ft) 68.98 Cum SA (acres) CULVERT REACH: S.F. Main RIVER: S.F. LICK CREEK RS: 6730. INPUT Description: Alex. Ave. Culvert (3-6x6) Distance from Upstream XS 7 Deck/Roadway Width 50 Weir Coefficient 2.6 Bridge Deck/Roadway Skew Upstream Deck/Roadway Coordinates num= 7 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 391 287.08 591 285.88 988.5 285.95 991.12 285.88 1491.12 288.88 Upstream Bridge Cross Section Data Station Elevation Data num= 10 Sta Elev Sta Elev Sta Elev 350 290 425 288 625 286.5 980.66 277 .68 1003.25 277.68 1003.75 285 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 350 .08 980.16 .014 1003.75 .OB Bank Sta: Left Right Coeff Contr. Expan. Sta 791.12 1003 Sta 684 1035 23.23 Hi Cord Lo Cord 287.08 285.95 Elev Sta 286 980.16 287 1072 Elev 285 288 Expan. .5 Channel 0.014 64.00 210.40 210.40 1212.46 23.59 5.76 8.92 70805 .8 37.26 0.10 0.60 42.13 4.64 Elev 285 288 Right OB 0.080 64.00 24.04 24.04 6 .99 27. 41 0.29 0.88 408.5 27 .46 0.02 0.00 61.94 19.37 980.16 1003.75 Ineffective Flow Sta L Sta R 350 980.16 num= 2 Elev Sta L 286 1003.75 .3 Sta R 1072 Downstream Deck/Roadway Coordinates num= 7 . 5 Elev 286 Sta Hi Cord Lo Cord 391 287.08 Sta Hi Cord Lo Cord 591 285.88 988.5 285.95 991.12 285 .88 1491.12 288.88 Downstream Bridge Cross Section Data Station Elevation Data num= 9 Sta Elev Sta Elev Sta Elev Sta Hi Cord Lo Cord 791.12 287 .08 1003 285.95 Sta Elev Sta Elev 621 287 718 286 805 285 980.16 285 980.66 277.5 1003.l 277.5 1003 .6 285 Manning's n Values num= Sta n Val Sta n Val 621 .08 980.16 .014 Bank Sta: Left Right Coe ff 980 .16 1003.6 Ineffective Flow num= Sta L Sta R Elev Sta L 621 980.16 285 1003.6 Upstream Embankment side slope Downstream Embankment side slope 1035 287 1072 288 3 Sta n Val 1003.6 .08 Contr. Expan. . 3 .5 2 Sta R Elev 1072 285 Maximum all owable submergence for weir flow Elevation at which weir flow begins 4 horiz. to 1.0 vertical 4 horiz. to 1.0 vertical .95 285.88 Energy head used in spillway design Spillway height used in design Weir crest shape Number of Culverts 1 Culvert Name Shape Rise Al ex. Ave. Box 6 FHWA Chart # 8 -flared wingwalls Span 6 Broad Crested FHWA Scale # 3 -Wingwall flared o deg. Solution Criteria = Highest U.S. EG (sides extended straight) Culvert Upstrm Dist Length n Value Entrance Loss Coef . 4 .5 64 .014 Number of Barrels = 3 Upstream Elevation Centerline St a t ions Sta. Sta. 983.66 991.93 Sta. 1000 277.72 Downstream Elevation= 277.54 Centerline Stations Sta. Sta. Sta. 983.66 991 .83 1000 CULVERT OUTPUT Profile #PF 1 Culvert ID : Alex. Ave. Culv Q (cfs) 652.02 # Barrels 3 Q Barrel (cfs) 217 .34 E.G. us. (ft) 287 .22 w.s. us. (ft) 286 .75 Delta EG (ft) 0 .35 Delta WS (ft) 2.97 E.G. IC (ft) 286.84 E.G. oc (ft ) 287.22 Cul v Vel In (ft/s) Culv Vel Out (ft/s) Cul v Inv El Up (ft) Cul v Inv El Dn (ft) Culv Frctn Ls (ft) Culv Ext Lss (ft) Cul v Ent Lss (ft) Q Weir (cfs) Weir Sta Lft (ft) Exit Loss Coef 1 6.04 6.04 277.72 277.54 0.12 0 .23 699.98 529 .11 Culvert Control Outlet Weir Sta Rgt (ft) 1043 .11 Culv WS In (ft) 283. 72 Weir Submerg 0.00 Culv WS Out (ft) 283 .54 Weir Max Depth (ft) 1. 34 Culv Nml Depth (ft) Weir Avg Depth (ft) 0.63 Culv Crt Depth (ft) Culv Ful Lngh (ft) 3.44 64.00 Wr Flw Area (sq ft) Min Top Rd (ft) 324.35 285.88 CROSS SECTION REACH: S.F. Main RIVER : S.F. LICK CREEK RS: 6698. INPUT Description: Down Station Elevation Sta Elev 621 287 1003.1 277.5 Stream Data Sta 718 1003.6 Manning's n Values Sta n Val Sta 621 .08 980.16 Bank Sta: Left Right 980.16 1003.6 Ineffective Flow num= Sta L Sta R Elev 621 980.16 285 Face of Alex. Ave Box Culvert num= 9 Elev Sta Elev Sta 286 805 285 980.16 285 1035 287 1072 num= 3 n Val Sta n Val .014 1003.6 .08 Lengths: Left Channel Right 23 23 23 2 Sta L Sta R Elev 1003.6 1072 285 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv . Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) 286.87 3.08 283.79 283.79 0.002686 2025.00 23.28 14.09 6.29 39071. 9 23.00 277.50 1. 00 0.07 0.59 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg . Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft ) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Elev Sta 285 980.66 288 Coeff Contr. .3 Left OB 23.00 68.68 22.94 Elev 277.5 Expan. .5 Channel 0.014 23.00 143.69 143.69 2025.00 23.28 14.09 6.17 39071. 9 35.04 0.69 9.69 41 .87 4.61 Right OB 23.00 61.93 19.35 Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculation s. Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, e nergy was used. CROSS SECTION REACH: S .F. Main INPUT RI VER: S.F. LICK CREEK RS: 6675. Description: 25' Down Stream of Alex. Ave. Station Elevation Data num= 10 Sta Elev Sta Elev Sta Elev 621 285 770 285 933 282 980 .66 277.5 1011. 3 277.5 1011 . 8 278.5 Manning's n Values num= 3 Sta Elev Sta Elev 977 281 980.16 278.5 1040 284 1086 287 Sta 621 n Val .08 Sta 980.16 Right 1011 .3 n Val Sta .025 1011.3 n Val .08 Lengths: Left Channel 43 43 Right 43 Bank Sta: Left 980 .16 Ineffective Flow Sta L Sta R 621 980.16 num= 2 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) Elev Sta L 285 1011.3 Sta R 1086 Elev 285 Profile #PF 1 285.28 1.91 283.37 282.59 0.003380 2025.00 178.31 11.09 5.87 34831.4 43.00 277.50 1. 00 0.08 0.82 El ement Wt . n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq f t) Stream Power (l b /ft s) Cum Vol ume (acre-ft) Cum SA (acres) Coeff Contr. . 3 Left OB 43.00 144.92 121.69 68.64 22 .91 Expan . . 5 Channel 0.025 43 .00 182.60 182.60 2025.00 31.14 11. 09 5 .86 34831.4 31.76 1.21 13 .45 41.79 4 .59 Right OB 43.00 63.53 25.48 61. 91 19.35 Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance r atio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1 .4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main INPUT Description: Station Elevation Data Sta Elev Sta 900 286 980 1335 277 1340 Manning's n Values Sta n Val Sta 900 .08 1308 Bank Sta: Left 1308 Right 1356 CROSS SECTION OUTPUT E.G. Elev (ft ) Vel Head (ft) W.S. Elev (ft ) Crit W.S. (ft ) E.G. Slope (ft/ft ) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd . (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) RS: 6632. num= 10 Elev Sta Elev Sta 281 1100 283.5 1230 277 1345 280 1356 num= 3 n Val Sta n Val .03 1356 .08 Lengths: Left Channel Right 20 Profile #PF 1 284.38 0 .26 284.11 0.001231 2025.00 459.58 2.01 7 .11 57727.2 20.00 277.00 4.19 0.03 0.00 20 20 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs) Top Width (ft ) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per . (ft) Shear (lb/sq ft) Stream Power (lb/ft s ) Cum Vol ume (acre-ft) Cum SA (acres) CROSS SECTION RI VER: S.F. LICK CREEK Elev Sta 282 1308 282 1420 Coeff Contr. .1 Left OB 0 .080 20.00 720.69 720.69 722.06 377.79 1. 00 1.91 20584.0 377.95 0.15 0.15 68.21 22.66 Elev 280 286 Expan. .3 Channel 0.030 20.00 249.37 249.37 1278.86 48.00 5.13 5.20 36456.8 49 .18 0.39 2.00 41.57 4.55 Right OB 0.080 20.00 35.68 35 .68 24.08 33.79 0.67 1. 06 686.4 33.86 0 .08 0.05 61. 86 19.32 REACH: S.F. Main RS: 6612. INPUT Description: Station Elevation Data num= 9 Sta El ev Sta Elev Sta Elev Sta El ev Sta Elev 900 286 980 281 1100 283 .5 1230 282 1308 280 1335 278 1345 280 1356 282 1420 286 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 900 .08 1308 .03 1356 .08 Bank Sta : Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1308 1356 189 189 189 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 284.35 Element Left OB Channel Right OB Vel Head (ft) 0.28 Wt. n-Val. 0 .080 0.030 0.080 w.s. Elev (ft) 284.06 Reach Len. (ft) 189 .00 189.00 189.00 Crit W.S. (ft) Flow Area (sq ft) 701.40 220.92 33.98 E.G. Slope (ft/ft) 0.001612 Area (sq ft) 701.40 220.92 33.98 Q Total (cfs) 2025.00 Flow (cfs) 791.10 1208.09 25.82 Top Width (ft) 457.95 Top Width (ft) 376.97 48.00 32.97 Vel Total (ft/s) 2.12 Avg. Vel. (ft/s) 1.13 5.47 0.76 Max Chl Dpth (ft) 6.06 Hydr. Depth (ft) 1.86 4.60 1. 03 Conv. Total (cfs) 50433.0 Conv. (cfs) 19702.4 30087.6 643.0 Length Wtd. (ft) 189.00 Wetted Per. (ft) 377.13 48 .45 33.04 Min Ch El (ft) 278.00 Shear (lb/sq ft) 0 .19 0.46 0.10 Alpha 4.09 Stream Power (lb/ft s) 0.21 2.51 0.08 Frctn Loss (ft ) 0.35 Cum Volume (acre-ft) 67 .89 41.46 61.84 C & E Loss (ft) 0.03 Cum SA (acres) 22.49 4.53 19.30 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 6423. INPUT Description: Station Elevation Data num= 14 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1030 286 1095 284 1150 282 1180 282 1225 282 .5 1310 282 1360 280 1374 277 1380 278 1408 278 1420 278 1430 284 1438 285 1510 286 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1030 .08 1360 .05 1430 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1360 1430 157 157 157 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 283 .97 Element Left OB Channel Right OB Vel Head (ft) 0.20 Wt. n-Val. 0 .080 0.050 w.s. Elev (ft) 283.78 Reach Len. (ft) 157.00 157.00 157.00 Crit W.S. (ft) Fl ow Area (sq ft) 434.25 370.47 E.G. Slope (ft/ft) 0.002088 Area (sq ft) 434.25 370.47 Q Total (cfs) 2025.00 Fl ow (cfs) 520.26 1504.74 Top Width (ft) 328 .51 Top Width (ft) 258.88 69.63 Vel Total (ft/s ) 2 .52 Avg. Vel. (ft/s) 1.20 4.06 Max Chl Dpth (ft) 6.78 Hydr. Depth (ft) 1 .68 5.32 Conv. Total (cfs) 44311.9 Conv. (cfs) 11384. 5 32927 .4 Length Wtd. (ft) 157.00 Wetted Per. (ft) 258.96 71.63 Min Ch El (ft) 277.00 Shear (lb/sq ft) 0.22 0.67 Alpha 1. 99 Stream Power (lb/ft s ) 0 .26 2.74 Frctn Loss (ft) 0.16 Cum Volume (acre-ft) 65.42 40.18 61.77 C & E Loss (ft) 0.04 Cum SA (acres) 21 .11 4.28 19.23 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 6266. INPUT Description: Station Elevation Data num= 13 Sta El ev Sta Elev Sta Elev Sta 1030 286 1090 284 118S 282 119S 1267 277 1280 278 1330 278 1340 1362 282 1480 284 1623 286 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1030 .08 119S .OS 1340 .08 Bank Sta : Left Right Lengths: Left Channel Right 119S 1340 91 91 91 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 283.78 El ement Vel Head (ft) 0.08 Wt. n-Val. w.s. Elev (ft) 283 .70 Reach Len. (ft) Crit W.S. (ft) Fl ow Area (sq ft ) E.G. Slope (ft/ft) 0.000621 Area (sq ft) Q Total (cfs) 202S .00 Fl ow (cfs) Top Width (ft) 3S7.67 Top Width (f t) Vel Total ( ft /s ) 1.89 Avg. Vel. (ft/s) Max Chl Dpth (ft) 6.70 Hydr. Depth (ft) Conv. Total (cfs) 81284.6 Conv. (cfs) Length Wtd. (ft ) 91.00 Wetted Per. (ft) Min Ch El (ft) 277.00 Shear (lb/sq ft) Alpha 1.42 Stream Power (l b /ft Frctn Loss (ft) 0.06 Cum Volume (acre-ft ) C & E Loss (ft) 0.00 Cum SA (acres) CROSS SECTION REACH: S .F. Main RIVER: S.F. LICK CREEK RS: 617S. INPUT Description: Station Elevation Data Sta Elev 1020 286 1230 278 1S47 284 Manning's n Values Sta n Val 1020 . 08 Sta 1100 126S 1SS8 Sta 1230 Bank Sta: Left 1230 Right 1310 CROSS SECTI ON OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s ) Max Chl Dpth (ft) Conv. Total (cfs) num= Elev 284 277 286 num= n Val .OS 12 Sta 1130 1310 3 Sta 1310 Elev 282 278 n Val .08 Sta 113S 131S Lengths: Left Channel Right llS llS llS Profile #PF 1 283.71 0.09 283.63 0.000778 202S.OO 406.38 1.71 6.63 72622.7 Element Wt. n-Val . Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (f t) Avg. Vel. (ft/s) Hydr . Depth (ft) Conv. (cfs) s) El ev Sta 280 1234 278 13SO Coeff Contr. .1 Left OB 0.080 91.00 9S.31 9S.31 4S.S6 90.S8 0.48 1. OS 1828 .6 90.80 0 .04 0.02 64.47 20.48 Elev Sta 280 1190 280 1360 Coeff Contr. .1 Left OB 0 .080 llS. 00 426.88 426 .88 SOl.73 124 .38 1.18 3.43 17993 .7 Elev 278 280 Expan . . 3 Channel o.oso 91 .00 809.98 809.98 1887 .04 14S .00 2.33 S .S9 7S746.9 14S.10 0.22 o.so 38 .0S 3.89 Elev 279.8 282 Expan . .3 Channel o.oso llS. 00 490.0S 490 .0S 13S9.21 80.00 2.77 6 .13 4874S.6 Right OB 0.080 91.00 164.22 164.22 92.40 122.09 O.S6 l.3S 3709.1 122.47 o.os 0.03 61.47 19.01 Right OB 0.080 llS. 00 264.82 264.82 164.0S 201.99 0.62 1.31 S883.4 Length Wtd. (ft) 115.00 Wetted Per. (ft) 124.86 80 .03 202.43 Min Ch El (ft) 277.00 Shear (lb/sq ft) 0.17 0.30 0.06 Alpha 1.89 Stream Power (lb/ft s) 0 .20 0.82 0.04 Frctn Loss (ft) 0.17 Cum Volume (acre-ft) 63.92 36.70 61 .03 C & E Loss (ft) 0.03 Cum SA (acres) 20.25 3.66 18.67 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 6050. INPUT Description: Station Elevation Data num= 13 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 1055 286 1140 284 1178 282 1194 280 1210 278 1228 276.5 1240 278 1260 280 1315 282 1422 283 1509 284 1547 285 1563 286 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1055 .08 1194 .05 1260 .08 Bank Sta: Left Right Lengths : Left Channel Right Coe ff Contr. Expan . 1194 1260 135 107 180 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 283.51 Element Left OB Channel Right OB Vel Head (ft) 0.39 Wt. n -Val. 0 .080 0.050 0.080 w.s. Elev (ft) 283.12 Reach Len . (ft) 135.00 107 .00 180.00 Crit W.S . (ft) Flow Area (sq ft) 45.96 324.64 184.14 E.G. Slope (ft/ft ) 0.003920 Area (sq ft) 45 .96 324 .64 184.14 Q Total (cfs) 2025.00 Flow (cfs) 61. 21 1740 .36 223.43 Top Width (ft) 276 .07 Top Width (ft) 37.34 66 .00 172.73 Vel Total (ft/s ) 3.65 Avg. Vel. (ft/s) 1. 33 5.36 1.21 Max Chl Dpth (ft) 6.62 Hydr. Depth (ft) 1. 23 4.92 1.07 Conv . Total (cfs) 32343.6 Conv. (cfs) 977 .7 27797.2 3568.6 Length Wtd. (ft) 123 .19 Wetted Per. (ft) 37.50 66.38 172 .77 Min Ch El (ft) 276.50 Shear (lb/sq ft) 0 .30 1.20 0 .26 Alpha 1.87 Stream Power (lb/ft s ) 0.40 6.42 0.32 Fr ctn Loss (ft ) 0.39 Cum Volume (acre-ft) 63 .30 35.62 60 .43 C & E Loss (ft) 0.03 Cum SA (acres) 20.04 3.46 18.18 CROSS SECTION RIVER : S.F. LICK CREEK REACH: S.F. Main RS: 5943. INPUT Description: Station Elevation Data num= 13 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 1000 284.3 1010 284 1030 280 1050 278 1060 276 1065 275 1075 275 1080 276 1085 278 1155 280 1200 282 1265 283 1354 284 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .08 1050 .05 1085 .08 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 1050 1085 110 116 95 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 283 .10 Element Left OB Channel Right OB Vel Head (ft) 0.29 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 282.81 Reach Len. (ft) 110 .00 116 .00 95.00 Crit W.S. (ft) Flow Area (sq ft ) 95 .92 238 .33 369.39 E.G. Slope (ft/ft) 0.002535 Area (sq ft) 95.92 238.33 369.39 Q Total (cfs) 2025.00 Flow (cfs) 177.64 1262 .52 584.84 Top Width (ft) 236.66 Top Width (ft) 34.05 35.00 167.62 Vel Total (ft/s) 2.88 Avg. Vel. (ft/s) 1. 85 5.30 1. 58 Max Chl Dpth (ft) 7.81 Hydr. Depth (ft) 2 .82 6.81 2.20 Conv. Total (cfs) 40217.2 Conv. (cfs) 3527.9 25074.l 11615.2 Length Wtd. (ft) 110.46 Wetted Per. (ft) 34.43 35.78 167.70 Min Ch El (ft) 275.00 Shear (lb/sq ft) 0.44 1. 05 0.35 Alpha 2.24 Stream Power (lb/ft s) 0.82 5 .58 0 .55 Frctn Loss (ft) 0.31 Cum Volume (acre-ft) 63.08 34.93 59.29 C & E Loss (ft) 0.01 Cum SA (acres) 19.93 3.34 17.48 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 5827. INPUT Description: Station Elevation Data num= 13 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 1038 284 1105 282 1145 280 1170 278 1180 276 1183 275 1195 275 1200 276 1210 278 1248 280 1333 282 1380 282.5 1438 284 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1038 .08 1170 .05 1210 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan . 1170 1210 170 211 130 .l .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 282.78 Element Left OB Channel Right OB Vel Head (ft) 0.36 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 282.42 Reach Len. (ft) 170.00 211. 00 130.00 Crit W.S. (ft) Flow Area (sq ft) 145.00 252.67 258.42 E.G. Slope (ft/ft) 0.003171 Area (sq ft) 145.00 252.67 258.42 Q Total (cfs) 2025.00 Flow (cfs) 227.15 1429.23 368 .62 Top Width (ft) 281.14 Top Width (ft) 78.96 40.00 162 .17 Vel Total (ft/s) 3.09 Avg. Vel. ( ft/s) 1. 57 5.66 1.43 Max Chl Dpth (ft) 7.42 Hydr. Depth (ft) 1. 84 6.32 1.59 Conv. Total (cfs) 35962 .0 Conv. (cfs) 4034.0 25381.7 6546.3 Length Wtd. (ft) 176.93 Wetted Per. (ft) 79.10 40.66 162.25 Min Ch El (ft) 275.00 Shear (lb/sq ft) 0.36 1.23 0.32 Alpha 2.44 Stream Power (l b/ft s) 0.57 6.96 0.45 Frctn Loss (ft) 0. 40 Cum Volume (acre-ft) 62 .77 34.28 58.61 C & E Loss (ft) 0.07 Cum SA (acres) 19.79 3 .24 17.12 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 5616. INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 938 283.6 1000 282.5 1080 282 1104 280 1113 276 1115 275 1125 275 1134 276 1138 278 1220 279.l 1400 280 1430 284 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 938 .08 1104 .05 1138 .08 Bank Sta: Left Right Lengths : Left Channel Right Coe ff Contr. Expan. 1104 1138 100 296 225 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 282.30 Element Left OB Channel Right OB Vel Head (ft) 0.12 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 282.19 Reach Len. (ft) 100.00 296.00 225.00 Crit W.S . (ft) Flow Area (sq ft) 31. 41 203.94 791. 50 E.G. Slope (ft/ft) 0.001687 Area (sq ft) 31.41 203.94 791. 50 Q Total (cfs) 2025.00 Flow (cfs) 16.62 796.91 1211. 46 Top Width (ft) 366.72 Top Width (ft) 54.30 34.00 278.42 Vel Total (ft/s) 1.97 Avg. Vel. (ft/s) 0.53 3.91 1 .53 Max Chl Dpth (ft) 7.19 Hydr . Depth (ft) 0.58 6.00 2.84 Conv. Total (cfs) 49295.3 Conv. (cfs) 404.7 19399.6 29491 .1 Length Wtd. (ft) 230.81 Wetted Per. (ft) 54.39 35 .61 278.58 Min Ch El (ft) 275. 00 Shear (lb/sq ft) 0.06 0.60 0.30 Alpha 1. 91 Stream Power (lb/ft s) 0.03 2.36 0.46 Fr ctn Loss (ft) 0.39 Cum Volume (acre-ft) 62.43 33 .17 57.04 C & E Loss (ft) 0.00 Cum SA (acres) 19.53 3.06 16.46 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 5320. INPUT Description: Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 994 283.4 1037 282 1086 280 1191 278 1260 278 1270 276 1273 275 1279 275 1300 276 1335 282 1415 284 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 994 .08 1260 .05 1335 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1260 1335 70 120 180 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 281.91 Element Left OB Channel Right OB Vel Head (ft) 0 .11 Wt. n-Val. 0.080 0.050 w.s. Elev (ft) 281.80 Reach Len. (ft) 70.00 120.00 180.00 Crit W.S . (ft) Flow Area (sq ft) 595.89 338 .12 E.G . Slope (ft/ft) 0.001700 Area (sq ft) 595.89 338.12 Q Total (cfs) 2025.00 Flow (cfs) 891. 61 1133.39 Top Width (ft) 291 .93 Top Width (ft) 218 .10 73 .83 Vel Total (ft/s) 2.17 Avg. Vel. (ft/s) 1.50 3.35 Max Chl Dpth (ft) 6 .80 Hydr. Depth (ft) 2.73 4.58 Conv. Total (cfs) 49120.2 Conv. (cfs) 21627.6 27492.6 Length Wtd. (ft) 100.49 Wetted Per. (ft) 218.16 74.71 Min Ch El (ft) 275.00 Shear (lb/sq ft) 0.29 0.48 Alpha 1. 55 Stream Power (lb/ft s) 0.43 1. 61 Fr ctn Loss (ft) 0.19 Cum Volume (acre-ft) 61. 71 31. 33 54.99 C & E Loss (ft) 0.01 Cum SA (acres) 19.22 2.69 15.74 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 5200. INPUT Description: Last Cypress Meadows Section Station Elevation Data num= 13 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1016 283.4 1051 282 1085 280 1192 278 1225 276 1227 274 1230 273 1240 273 1245 274 1254 276 1275 280 1329 282 1404 283 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1016 .08 1225 .05 1275 .08 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 1225 1275 200 100 150 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 281.71 Element Left OB Channel Right OB Vel Head (ft) 0.20 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 281.51 Reach Len. (ft) 200.00 100.00 150.00 Crit W.S. (ft) Flow Area (sq ft) 436.62 294.45 30.74 E.G. Slope (ft/ft) 0.002132 Area (sq ft) 436.62 294.45 30.74 Q Total (cfs) 2025 .00 Fl ow (cfs) 714.22 1288.94 21.84 Top Width (ft) 256.40 Top Width (ft) 165.65 50.00 40.74 Vel Total (ft/s) 2.66 Avg. Vel. (ft/s) 1.64 4.38 0.71 Max Chl Dpth (ft) 8.51 Hydr . Depth (ft) 2.64 5.89 0.75 Conv. Total (cfs) 43851.9 Conv. (cfs) 15466.6 27912.3 473.0 Length Wtd. (ft) 142.87 Wetted Per. (ft) 165.78 51.69 40.77 Min Ch El (ft) 273.00 Shear (lb/sq ft ) 0.35 0.76 0.10 Alpha 1. 86 Stream Power (lb/ft s) 0 .57 3.32 0.07 Frctn Loss (ft) 0.51 Cum Volume (acre-ft) 60.88 30.46 54.93 C & E Loss (ft) 0.01 Cum SA (acres) 18.91 2.52 15.66 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1 .4. This may indicate the need for additional cross sections . CROSS SECTION REACH: S.F. Main INPUT Description: Station Elevation Sta Elev 382 283.4 533 273.37 712 281.1 Manning's n Values Sta n Val 382 . 08 RIVER: S.F. LICK CREEK RS: 5050. Data Sta 419 535 780 num= Elev 281.03 278.07 281.89 num= Sta n Val 525 . 05 13 Sta 500 560 868 3 Sta 535 Elev 278.31 277.82 283 n Val .08 Sta 525 613 El ev 276.22 278.11 Sta 527 668 Bank Sta: Left 525 Right 535 Lengths: Left Channel 238 210 Right 130 Coeff Contr. . 1 CROSS SECTION OUTPUT E .G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft ) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) Profile #PF 1 281.19 0.26 280 .93 0.007249 2025.00 286.37 3.08 7.56 23784.3 188.88 273.37 1. 78 0. 45 0.04 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.080 238 .00 194.02 194.02 467.35 103.08 2.41 1.88 5489.2 103.21 0.85 2.05 59.43 18.29 Elev 273.8 279.1 Expan . .3 Channel 0.050 210.00 66.35 66.35 467.81 10.00 7.05 6.63 54 94. 6 14.26 2 .11 14.84 30.04 2.45 Right OB 0.080 130.00 396.79 396.79 1089.84 173.30 2.75 2.29 12800.5 173.35 1.04 2 .85 54.19 15.29 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1 .4. This may indicate the need for additional cross sections. CROSS SECTION REACH: S.F. Main INPUT RIVER: S.F. LICK CREEK RS: 4930. Description: New Section Added 10-20-99 Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev 0 282.8 57 280 117 279 228 275.97 292 273.64 296 273.64 Sta Elev Sta Elev 190 277 .5 227 277 300 275.97 331 277.53 375 279 Manning's n Values Sta n Val 0 . 08 458 282.81 num= Sta n Val 228 . 05 3 Sta 300 n Val .08 Bank Sta: Left 228 Right 300 Lengths: Left Channel 150 180 Right 250 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpt h (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) CROSS SECTION REACH: S .F. Main INPUT Description: Station Elevation Data Profile #PF 1 280 .70 0.12 280.58 0. 001181 2025.00 364.15 1. 96 6.94 58920 . l 209 .11 273.64 2.02 0.23 0.02 El ement Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: S.F. LICK CREEK RS: 4810. num= 10 Sta Elev Sta Elev Sta Elev Sta Coe ff Contr. .1 Left OB 0.080 150.00 365.29 365.29 369.35 182.77 1.01 2.00 10746.9 183.25 0.15 0.15 57.90 17.51 El ev Sta 900 283 1145 280.78 1221 279.59 1242 274.96 1246 1251 271.91 1258 276.07 1316 276 .05 1466 276 1666 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 900 .08 1242 .OS 1258 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. 1242 1258 300 100 200 .1 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 280.45 Element Left OB Vel Head (ft) 0.05 Wt. n-Val. 0.080 w.s. Elev (ft) 280.40 Reach Len. (ft) 300.00 Crit W.S. (ft) Flow Area (sq ft) 86 .37 E.G. Slope (ft/ft) 0 .001007 Area (sq ft) 86.37 Q Total (cfs) 2025.00 Flow (cfs) 56.92 Top Width (ft) 406.48 Top Width (ft) 72.55 Vel Total (ft/s) 1. 50 Avg. Vel. (ft/s) 0.66 Max Chl Dpth (ft) 8.59 Hydr. Depth (ft) 1.19 Conv. Total (cfs) 63813.5 Conv. (cfs) 1793.6 Length Wtd. (ft) 204.45 Wetted Per. (ft) 73.06 Min Ch El (ft) 271. 81 Shear (lb/sq f t) 0 .07 Alpha 1. 54 Stream Power (lb/ft s) 0.05 Frctn Loss (ft) 0.30 Cum Volume (acre-ft) 57 .13 C & E Loss (ft) 0.01 Cum SA (acres) 17.07 Expan. .3 Channel Right OB 0.050 0.080 180.00 250.00 420.33 247.59 420.33 247.59 1383.34 272.30 72.00 109.38 3 .29 1.10 5.84 2.26 40250.2 7923 .0 72. 67 109.48 0.43 0.17 1.40 0.18 28.87 53 .23 2 .26 14.86 Elev 271. 81 284 Expan. . 3 Channel Right OB 0.050 0 .080 100.00 200.00 115. 58 1149. 07 115 . 58 1149. 07 373.33 1594.75 16.00 317.93 3.23 1.39 7.22 3.61 11764.8 50255.l 18.24 318.02 0.40 0.23 1.29 0.32 27.76 49.23 2.07 13.64 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4 . This may indicate the need for additional cross sections. CROSS SECTION REACH: S.F. Main INPUT RIVER: S.F. LICK CREEK RS: 4580. Description: Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 505 281.9 555 278 593 277.9 668 276.42 735 276.24 739 271.5 746 271.5 750 275. 72 830 278 933 280.2 1013 282 .6 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 505 .08 735 .05 750 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 735 750 170 340 270 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft ) 280.14 Element Left OB Channel Right OB Vel Head (ft) 0 .12 Wt . n-Val . 0.080 0.050 0.080 w.s. Elev (ft) 280.02 Reach Len. (ft) 170.00 340 .00 270.00 Crit W.S . (ft) Fl ow Area (sq ft) 567.26 109.93 348.92 E.G. Slope (ft/ft) 0.002382 Area (sq ft) 567.26 109.93 348.92 Q Total (cfs) 2025.00 Fl ow (cfs) 1010.04 513.53 501.42 Top Width (ft) 395.68 Top Width (ft ) 205.94 15.00 174.73 Vel Total (ft/s) 1.97 Avg. Vel. (ft/s) 1.78 4.67 1 .44 Max Chl Dpth (ft) 8 .52 Hydr. Depth (ft) 2.75 7 .33 2.00 Conv. Total (cfs) 41495.3 Conv. (cfs) 20697.3 10523.1 10275.0 Length Wtd. (ft) 226.25 Wetted Per. (ft) 206.04 19.02 174.79 Min Ch El (ft) 271. 50 Shear (lb/sq ft) 0.41 0.86 0.30 Alpha 1. 96 Stream Power (lb/ft s) 0.73 4.01 0.43 Frctn Loss (ft) 0 .71 Cum Volume (acre-ft) 54.88 27.50 45.79 C & E Loss (ft) 0.01 Cum SA (acres) 16 .11 2.04 12.51 CROSS SECTION RI VER: S.F. LICK CREEK REACH: S.F. Main RS: 4310. INPUT Description: Station Elevation Data num= 11 Sta El ev Sta Elev Sta Elev Sta El ev Sta Elev 730 280.3 1000 277.9 1030 275.95 1090 274.97 1153. 5 274.52 1158. 5 271. 28 1165 274.54 1174 275 .51 1183 277.51 1198 278.96 1261 281.16 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 730 .08 1153 .5 .05 1165 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr . Expan. 1153.5 1165 450 450 450 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G . Elev (ft) 279 .43 El ement Left OB Channel Right OB Vel Head (ft) 0.18 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 279.25 Reach Len. (ft ) 450.00 450.00 450.00 Crit W.S. (ft) Flow Area (sq ft) 684.93 72.93 79.01 E.G. Slope (ft/ft) 0.004316 Area (sq ft) 684.93 72. 93 79.01 Q Total (cf s) 2025.00 Flow (cfs) 1432 .76 444.33 147.90 Top Width (ft) 357.81 Top Width (ft) 305.08 11. 50 41.23 Vel Total (ft/s ) 2.42 Avg. Vel. (ft/s) 2.09 6.09 1 .87 Max Chl Dpth (ft ) 7 .97 Hydr. Depth (f t) 2.25 6.34 1.92 Conv. Total (cfs) 30823.7 Conv. (cfs) 21808.9 6763.4 2251. 3 Length Wtd. (ft ) 450 .00 Wetted Per. (ft) 305.16 13.23 41.58 Min Ch El (ft) 271.28 Shear (lb/sq ft) 0.60 1.49 0.51 Alpha 1.96 Stream Power (lb/ft s) 1.27 9 .05 0.96 Frctn Loss (ft) 1.61 Cum Volume (acre-ft) 52 .43 26.79 44.46 C & E Loss (ft) 0.01 Cum SA (acres) 15.11 1 .94 11. 84 Warning: The energy l oss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 3860. INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 600 280.8 1000 276.8S 1048 27S 1068 272.98 1111 273.3 1120 272. 2S 1137 268.93 1141 268.93 114S 272.98 ll 7S 27S.13 1203 27S.7S 127S 280 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 600 .08 1120 .OS 114S .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1120 114S 110 110 110 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 277.80 Element Left OB Channel Right OB Vel Head (ft) 0.28 Wt. n-Val. 0.080 o.oso 0.080 w.s. Elev (ft) 277.S2 Reach Len. (ft) 110. 00 110. 00 110.00 Crit W.S. (ft) Flow Area (sq ft) 401.lS 178.46 188.83 E.G. Slope (ft/ft) 0.003021 Area (sq ft) 401.lS 178.46 188.83 Q Total (cfs) 202S.00 Flow (cfs ) 678.3S 1026.29 320.36 Top Width (ft) 300.97 Top Width (ft) 187.96 2S.OO 88.01 Vel Total (ft/s) 2.64 Avg. Vel. (ft/s) 1.69 S.7S 1. 70 Max Chl Dpth (ft) 8.S9 Hydr. Depth (ft) 2.13 7.14 2.lS Conv. Total (cfs) 36843.1 Conv. (cfs) 12342.0 18672. s S828.6 Length Wtd. (ft) 110. 00 Wetted Per. (ft) 188.17 27.01 88.14 Min Ch El (ft) 268.93 Shear (lb/sq ft) 0 .40 1. 2S 0. 40 Alpha 2.62 Stream Power (lb/ft s) 0.68 7.17 0.69 Frctn Loss (ft) 0.29 Cum Volume (acre-ft) 46.82 2S.49 43.08 C & E Loss (ft) 0.04 Cum SA (acres) 12.S7 1. 7S 11.17 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 366S. INPUT Description: Station Elevation Data num= 8 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 9SO 279.6 1000 276 1086 272.S 1087 268 .7 1100 268.7 1101 272 124S 276 1300 279.7S Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 9SO .08 1086 .OS 1101 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1086 1101 30 80 SS .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G . Elev (ft) 277.47 Element Left OB Channel Right OB Vel Head (ft) O.lS Wt. n-Val. 0.080 o.oso 0.080 W.S. Elev (ft) 277.32 Reach Len. (ft) 30.00 80.00 SS.00 Crit W.S. (ft) Flow Area (sq ft) 27S.92 12S. 72 490.SS E.G. Slope (ft/ft) 0.002401 Area (sq ft) 27S.92 12S. 72 490 .SS Q Total (cfs) 202S .00 Flow (cfs) 480.01 61S.90 929.09 Top Width (ft) 282.64 Top Width (ft) 104.31 lS.00 163.33 Vel Total (ft/s) 2.27 Avg. Vel. (ft/s) 1.74 4.90 1.89 Max Chl Dpth (ft) 8.62 Hydr . Depth (ft) 2 .6S 8.38 3.00 Conv. Total (cfs) 41322.S Conv. (cfs) 979S.2 12S68.2 189S9.l Length Wtd. (ft) S6.79 Wetted Per. (ft) 104.43 20.38 163.43 Min Ch El (ft) 268.70 Shear (lb/sq ft) 0.40 0.92 0.4S Alpha 1.88 Stream Power (lb/ft s) 0.69 4.S3 0.8S Frctn Loss (ft) C & E Loss (ft) 0 .01 0.02 Cum Volume (acre-ft) Cum SA (acres) 45.97 12.20 25 .11 1.70 42 .22 10.85 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1 .4. This may indicate the need for additional cross sections. CROSS SECTION REACH: S.F. Main INPUT Description: 14' us of RIVER: S.F. LICK CREEK RS: 3610. longmire culvert Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev 936 279.6 986 276 1043 274 Sta Elev Sta 1076 272 1094 1106 267.97 1115 268 1144 273 1219 273.65 1243 1293 279.5 Manning's n Values Sta n Val 936 .025 Sta 1094 Bank Sta: Left Right 1094 1115 Ineffective Flow num= Sta L Sta R Elev 936 1076 276.92 num= n Val .018 Lengths: 2 Sta L 1144 3 Sta 1115 Left 14 Sta R 1293 n Val .025 Channel 14 Elev 276.92 Right 14 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs} Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) CROSS SECTION REACH: S.F. Main INPUT 277.43 0.08 277 .35 273.08 0.000091 2025.00 295.04 1.70 9.38 212284.7 14 .00 267.97 1.86 0.00 0.02 Element Wt . n-Val. Reach Len. (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: S.F. LICK CREEK RS: 3596. Description: us face of longmire culvert 12 Sta 2300 Station Elevation Data num= Sta Elev Sta Elev 2200 277.96 2250 277.5 Coeff Contr. .3 Left OB 0.025 14.00 422.46 422.46 532.81 126.75 1.26 3.33 55855.3 127.33 0.02 0.02 45.73 12.12 Sta 2396 Elev 268 276 Expan. .5 Channel 0.018 14.00 196.67 196.67 688.06 21.00 3.50 9.37 72130.8 21.00 0 .05 0.19 24.81 1.66 Elev 273.5 2396 2550 267.6 2427.5 267.6 2427.5 Elev 276 273.6 Sta 2350 2450 Elev 274.65 273.5 2500 274.25 276.7 2600 277 .86 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 2200 .025 2396 .018 2427.5 .025 Bank Sta: Left Right Lengths: Left Channel 2396 2427.5 61 61 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 2200 2396 276.92 2427.5 2600 276.92 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 277 .41 Element Right 61 Coeff Contr. .3 Left OB Expan. .5 Channel Right OB 0.025 14.00 574.14 574.14 804 .13 147.29 1.40 3.90 84298.5 147.88 0.02 0.03 41.55 10.66 Right OB Vel Head (ft) W.S. Elev (ft) Cri t W. S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 0.16 277.25 272.63 0.000174 2025.00 315.37 2.20 9.65 153471.6 61.00 267.60 2.11 Wt. n-Val. Reach Len. (ft) Fl ow Area (sq ft) Area (sq ft) Fl ow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) CULVERT REACH: S.F. Main RIVER: S.F. LICK CREEK RS: 3567. INPUT Description: Distance from Upstream XS 1 Deck/Roadway Width 57 Weir Coefficient 3 Bridge Deck/Roadway Skew Upstream Deck/Roadway Coordinates num= 7 0.025 61.00 268.34 268.34 328.29 137.67 1 .22 1. 95 24880.9 137.72 0.02 0.03 45.62 12.08 Sta Hi Cord Lo Cord 2200 277.96 Sta Hi Cord Lo Cord 2300 277.46 Sta Hi Cord Lo Cord 2375 277 2400 276.92 2425 276.99 2600 277.86 Upstream Bridge Cross Section Data Station Elevation Data num= Sta El ev Sta Elev 2200 277.96 2250 277 .5 2396 267.6 2427.5 267 .6 2550 276.7 2600 277.86 Manning's n Values Sta n Val 2200 .025 Sta 2396 num= n Val .018 12 Sta 2300 2427.5 3 Sta 2427.5 Bank Sta: Left 2396 I neffective Flow Sta L Sta R Right 2427.5 Coeff Contr. . 3 2200 2396 num= El ev 276.92 Sta L 2427.5 2 Sta R 2600 Downstream Deck/Roadway Coordinates num= 7 Elev 276 273.6 n Val .025 Expan. .5 Elev 276.92 Sta Hi Cord Lo Cord 2200 277.96 Sta Hi Cord Lo Cord 2300 277.46 2400 276.92 2600 277.86 Downstream Bridge Station Elevation Sta El ev 2200 277.96 2396 267.48 2550 276 Manning's n Values Sta n Val 2200 .025 2425 276.99 Cross Section Data Data num= 12 Sta El ev Sta 2250 277.5 2300 2427.5 2600 Sta 2396 267.48 277.86 num= n Val .018 2427.5 3 Sta 2427.5 Bank Sta: Left 2396 Ineffective Flow Sta L Sta R Right 2427.5 Coeff Contr. .3 num= 2 El ev Sta L Sta R Elev 276.2 273.5 n Val .025 Expan. . 5 Elev 2500 277.36 Sta 2350 2450 Elev 274.65 273.5 Sta 2396 2500 Sta Hi Cord Lo Cord 2375 277 2500 277.36 Sta 2350 2450 Elev 273.85 273 Sta 2396 2500 0 .018 61 .00 303.97 303.97 1212.05 31.50 3.99 9.65 91859.3 43.40 0.08 0.30 24.73 1.65 Elev 273.5 274.25 Elev 273.4 273.5 0.025 61.00 347.26 347.26 484.66 146.21 1.40 2.38 36731.3 146.28 0.03 0.04 41.40 10.61 2200 2396 276.92 2427.5 Upstream Embankment side slope Downstream Embankment side slope 2600 276.92 Maximum allowable submergence for weir flow El evation at which weir flow begins 4 horiz. to 1.0 vertical 4 horiz. to 1.0 vertical .95 276.92 Energy head used in spillway design Spillway height used in design Weir crest shape Number of Cul verts 1 Cu l vert Name Shape Rise Longmire Dr Box 7.7 FHWA Chart # 8 -flared wingwalls Span 10 Broad Crested FHWA Scale # 1 -Wingwall flared 30 to 75 deg. Solution Criteria = Highest U.S. EG Culvert Upstrm Dist Length n Value Entrance Loss Coef .5 1 57 .014 Number of Barrels = 3 Upstream Elevation Centerline Stations Sta. Sta. 2401 2411 .5 Sta. 2422 267.6 Downstream El evation = 267.48 Centerline Stations Sta. Sta. Sta. 2401 2411.5 2422 CULVERT OUTPUT Profile #PF 1 Culvert ID : Longmire Dr Culv Q (cfs) 1938.63 # Barrels 3 Q Barrel (cfs) 646.21 E.G. us. (ft) 277.40 w.s. us. (ft) 277.25 Delta EG (ft) 0.80 Delta ws (ft) 1. 61 E.G. IC (ft) 276.04 Culv Vel In (ft/s) Culv Vel Out (ft/s) Culv Inv El Up (ft) Cul v Inv El Dn (ft) Cul v Frctn Ls (ft) Culv Ext Lss (ft) Cul v Ent Lss (ft) Q Weir (cfs) Exit Loss Coef 1 8.39 8.39 267.60 267 .48 0 .13 0.13 0.55 86.37 E.G. oc (ft) 277.40 Weir Sta Lft (ft) 2309.54 Culvert Control Outlet Weir Sta Rgt (ft) 2508.30 Culv WS In (ft) 275.30 Weir Submerg 0.00 Culv ws Out (ft) 275 .18 Weir Max Depth (ft) 0 .48 Culv Nml Depth (ft) Weir Avg Depth (ft) 0.26 Cul v Crt Depth (ft) 5.06 Wr Flw Area (sq ft) 52 .50 Culv Ful Lngh (ft) 57.00 Min Top Rd (ft) 276.92 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 3538. INPUT Description: ds of longmire culvert Station Elevat ion Data num= 12 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 2200 277 .96 2250 277.5 2300 276.2 2350 273.85 2396 273.4 2396 267.48 2427.5 267.48 2427.5 2550 276 2600 277.86 Manning's n Values num= 3 Sta n Val Sta n Val Sta 2200 .025 2396 .018 2427.5 Bank Sta: Left Right Lengths: Left 2396 2427.5 18 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R 2200 2396 276.92 2427 .5 2600 CROSS SECTION OUTPUT Profile #PF 1 273.5 n Val .025 Channel 18 Elev 276 .92 2450 Right 18 273 2500 Coeff Contr. .3 273.5 Expan. . 5 E.G. Elev (f t) 276.60 Element Left OB Channel Right OB Vel Head (f t) 0.96 Wt. n-Val. 0.018 w.s. Elev (f t) 275.64 Reach Len. (ft) 18.00 18.00 18.00 Crit W.S . (f t) 272.51 Flow Area (sq ft) 256.94 E.G. Slope (ft/ft) 0.000852 Area (sq ft) 126.51 256.94 218. 71 Q Total (cf s) 2025.00 Fl ow (cfs) 2025.00 Top Width (ft) 230 .75 Top Width (ft) 84. 02 31.50 115.24 Vel Total (ft/s) 7.88 Avg. Vel. (ft/s) 7.88 Max Chl Dp th (ft) 8.16 Hydr. Depth (ft) 8.16 Conv. Total (cfs) 69371.8 Conv. (cfs) 69371 .8 Length Wtd. (ft} 18.00 Wetted Per. (ft} 43.44 Min Ch El (ft} 267 .48 Shear (lb/sq ft) 0.31 Alpha 1. 00 Stream Power (lb/ft s} 2 .48 Frctn Loss (ft) 0.01 Cum Volume (acre-ft) 45.34 24.34 41. 00 C & E Loss (ft) 0.33 Cum SA (acres) 11. 92 1. 61 10.43 Warning: The velocity head has changed by more than 0.5 ft (0 .15 m}. This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance} is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections . CROSS SECTION REACH: S.F. Main RIVER: S.F. LI CK CREEK RS: 3520. INPUT Description: ds of ex longmire culvert Station Elevation Data num= 11 Sta Elev Sta Elev Sta Elev Sta 969 277 .6 1018 273.5 1043 272 .5 1063 1075 267.36 1083 267.36 1087 268 1107 1266 277 .86 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 969 .025 1063 .018 1087 .025 Bank Sta: Left Right Lengths: Left Channel Right 1063 1087 50 50 50 CROSS SECTI ON OUTPUT Profile #PF 1 E.G. El ev (f t) 276.26 El ement Vel Head (ft) 0.30 Wt . n-Val. w.s. Elev (f t) 275.96 Reach Len. (ft ) Crit W.S. (ft) Flow Area (sq f t) E.G. Slope (ft/ft} 0.000272 Area (sq ft) Q Total (cf s) 2025.00 Flow (cfs) Top Width (ft) 218.98 Top Width (ft) Vel Total (ft/s) 2.95 Avg. Vel. (ft/s) Max Chl Dpt h (ft) 8.60 Hydr . Depth (ft) Conv. Total (cfs) 122867.3 Conv. (cfs) Length Wtd. (ft) 50.00 Wetted Per. (ft) Min Ch El (ft) 267.36 Shear (lb/sq ft) Alpha 2.25 Stream Power (lb/ft Frctn Loss (ft) 0 .02 Cum Volume (acre-ft) C & E Loss (ft) 0.09 Cum SA (acres) Elev Sta Elev 268 1067 267.36 273 1209 276 Coef f Contr . Expan. . 3 .5 Left OB Channel Right OB 0.025 0 .018 0.025 50 .00 50.00 50.00 224.27 203.81 258.00 224.27 203.81 258.00 455 .96 1150. 95 418.09 74.39 24.00 120.60 2.03 5.65 1. 62 3.01 8 .49 2.14 27665 .4 69834.3 25367.6 75.01 24.10 121. 26 0.05 0.14 0.04 s) 0.10 0.81 0.06 45.27 24.24 40.90 11. 89 1. 60 10.38 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance} is less than 0.7 or greater than 1.4 . This may indicate the need for additional cross sections. CROSS SECTION REACH : S .F . Main RIVER: S.F. LICK CREEK RS: 3467. INPUT Description: Station Elevation Data num= Sta El ev Sta Elev 11 Sta Elev Sta El ev Sta Elev 957 278.75 1005 275 1038 274.5 1053 274 1077.5 268 1086 267.03 1095 268 1107 271 1155 272.6 1282 274 1332 278.75 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 957 .08 1053 .05 1107 .08 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 1053 1107 57 57 57 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 276.15 Element Left OB Channel Right OB Vel Head (ft) 0.13 Wt. n-Val. 0.080 0.050 0.080 w.s. Elev (ft) 276.02 Reach Len. (ft) 57.00 57.00 57.00 Crit W.S. (ft) Flow Area (sq ft) 75.31 350.24 570.10 E.G. Slope (ft/ft) 0.001185 Area (sq ft) 75.31 350.24 570.10 Q Total (cfs) 2025.00 Flow (cfs) 55.33 1228.00 741.67 Top Width (ft) 311.39 Top Width (ft) 61.10 54.00 196.30 Vel Total (ft/s) 2 .03 Avg. Vel. (ft/s) 0.73 3.51 1.30 Max Chl Dpth (ft) 8.99 Hydr. Depth (ft) 1.23 6.49 2.90 Conv. Total (cfs) 58825.l Conv. (cfs) 1607.3 35672 .6 21545.3 Length Wtd. (ft) 57.00 Wetted Per. (ft) 61.15 55.20 196.43 Min Ch El (ft) 267.03 Shear (lb/sq ft) 0.09 0.47 0.21 Alpha 1. 96 Stream Power (lb/ft s) 0.07 1. 65 0.28 Frctn Loss (ft) 0.08 Cum Volume (acre-ft) 45.10 23.92 40.43 C & E Loss (ft) 0.01 Cum SA (acres) 11.81 1.55 10.20 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S.F. Main RS: 3410. INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1375 278.4 1410 275 1459 274 1510 271.47 1514 266.68 1521 266.68 1525 271. 29 1546 272 1627 273.33 1702 272 1727 274 1757 278 .5 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1375 .08 1510 .05 1525 .08 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 1510 1525 210 210 210 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 276.06 Element Left OB Channel Right OB Vel Head (ft) 0 .10 Wt. n-Val . 0.080 0.050 0.080 w.s. Elev (ft) 275.96 Reach Len. (ft) 210.00 210.00 210.00 Crit W.S. (ft) Flow Area (sq ft) 240.27 120.33 690.49 E.G. Slope (ft/ft) 0.001817 Area (sq ft) 240.27 120.33 690.49 Q Total (cfs) 2025.00 Flow (cfs) 320 .36 515.64 1189. 00 Top Width (ft) 339 .87 Top Width (ft) 109.84 15.00 215.04 Vel Total (ft/s) 1.93 Avg. Vel. (ft/s) 1. 33 4 .29 1.72 Max Chl Dpth (ft) 9.28 Hydr. Depth (ft) 2 .19 8.02 3.21 Conv. Total (cfs) 47503.1 Conv. (cfs) 7515.2 12096.0 27892.0 Length Wtd. (ft) 210 .00 Wetted Per. (ft) 109.96 19.34 215 .30 Min Ch El (ft) 266.68 Shear (lb/sq ft) 0.25 0. 71 0.36 Alpha 1.80 Stream Power (lb/ft s) 0.33 3.02 0.63 Frctn Loss (ft) 0.45 Cum Volume (acre-ft) 44.89 23.62 39.60 C & E Loss (ft) 0.02 Cum SA (acres) 11. 70 1.51 9.93 CROSS SECTION RIVER: S.F. LICK CREEK REACH: S .F. Main RS: 3200. INPUT Description: Station Elevation Data num; 10 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev s oo 277 . 72 6S9 274.7S 68S 273.84 70S 273.18 72S 271.S 74S 26S.63 7S6 26S .63 7S9 271.17 840 273.34 1078 280.17 Manning's n Values num; 3 Sta n Val Sta n Val Sta n Val soo .08 72S .OS 7S9 .08 Bank Sta: Left Right Lengths : Left Channel Right Coef f Contr. Expan. 72S 7S9 330 330 330 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 27S.S9 El ement Left OB Channel Right OB Vel Head (ft) 0.33 Wt . n-Val . 0 .080 o.oso 0.080 w.s. Elev (ft) 27S .26 Reach Len. (ft) 33 0.00 330.00 330 .00 Crit W.S. (ft) Fl ow Area (sq ft ) 12S.Sl 260.43 307.73 E.G . Slope (ft/ft ) 0.002S62 Area (sq ft) 12S.Sl 260.43 307 .73 Q Total (cfs) 202S.OO Fl ow (cfs) 143.66 1409. 98 471 .36 Top Width (ft) 27S.26 Top Width (ft) 93 .34 34.00 147 .93 Vel Total (ft/s ) 2.92 Avg. Vel. (ft/s) 1.14 S.41 l .S3 Max Chl Dpth (ft ) 9.63 Hydr . Depth (ft) 1 .34 7.66 2.08 Conv . Total (cfs) 40004 .S Conv. (cfs) 2838 .l 278S4 .6 9311. 8 Length Wtd. (ft) 330.00 Wetted Per . (ft) 93.44 38.14 147.98 Min Ch El (ft) 26S.63 Shear (lb/sq ft) 0 .21 l. 09 0.33 Alpha 2 .47 Stream Power (lb/ft s ) 0.2S S.91 O.Sl Frctn Loss (ft) 0 .74 Cum Volume (acre-ft) 44.01 22.70 37.20 C & E Loss (ft) 0.07 Cum SA (acres) 11 . 21 1 .39 9 .0S CROSS SECTION RIVER: S .F . LICK CREEK REACH: S.F . Main RS: 2880 . INPUT Description: Station Elevation Data num; 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 276.8 1100 276 .3 1200 27S.S 1300 272 .7S 1330 269.3S 1332 26S.44 1336 264.9S 1340 26S.Sl 1343 269.S6 1S27 272 .46 1627 274.2 1784 278 .7 Manning's n Values num; 3 Sta n Val Sta n Val Sta n Val 1000 .08 1330 .OS 1343 .08 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1330 1343 3SO 3SO 3SO .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft ) 274 .78 El ement Left OB Channel Right OB Vel Head (ft) 0 .11 Wt . n-Val. 0 .080 o.oso 0.080 w.s. Elev (ft ) 274.67 Reach Len. (ft) 3SO .OO 3SO .OO 3SO.OO Crit W.S. (ft ) Flow Area (sq ft ) 17S.68 111. 62 811. 4S E.G. Slope (ft/ft ) 0 .001991 Area (sq ft) 17S.68 111.62 811. 4S Q Total (cf s) 202S.OO Flow (cfs) 211. 88 S09.0l 1304.10 Top Width (ft ) 413 .2S Top Width (ft) 99 .84 13.00 300.42 Vel Total (ft/s ) 1.84 Avg. Vel. (ft/s ) 1.21 4 .S6 1.61 Max Chl Dpth (ft ) 9.72 Hydr. Depth (ft) 1 .76 8 .S9 2 .70 Conv . Total (cfs) 4S387.l Conv . (cfs) 4749 .l 11408.7 29229 .4 Length Wtd. (ft) 3SO.OO Wetted Per. (ft) 100 .06 17.SO 300.46 Min Ch El (ft ) 264.9S Shear (lb/sq ft) 0 .22 0 .79 0 .34 Alpha 2 .07 Stream Power (lb/ft s ) 0.26 3 .61 0.S4 Frctn Loss (ft) 0.40 Cum Volume (acre-ft) 42.87 21 .29 32 .96 C & E Loss (ft) 0 .01 Cum SA (acres) 1 0. 48 l. 21 7 .3S Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1.4 . This may indicate the need f or additional cross sections . CROSS SECTION REACH : S.F. Main RIVER: S.F. LICK CREEK RS: 2560. INPUT Description: Station Elevation Data Sta El ev 1000 277 .12 1484 263.78 1824 276 Manning's n Values Sta n Val 1000 .08 Sta 1206 1493 Sta 1469 Bank Sta: Left 1469 Right 1493 CROSS SECTI ON OUTPUT E.G . Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (f t) Al pha Frctn Loss (ft) C & E Loss (ft) num= 11 Elev Sta Elev Sta Elev Sta 274.15 1390 272.16 1469 268.87 1475 268.97 1560 269 .48 1660 271 . 38 1740 num= n Val .05 3 Sta 1493 n Val .08 Lengths: Left Channel Right 50 Profile #PF 1 274.37 0.06 274.30 0.000739 2025.00 552.03 1.29 10.52 74515.4 50.00 263.78 2.46 0.01 0.09 50 50 El ement Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/ sq ft) Stream Power (l b /ft s) Cum Volume (acre-ft) Cum SA (acres) Coeff Contr. . 3 Left OB 0.080 50.00 511. 44 511 .44 391.62 273.65 0.77 1.87 14410.6 273.73 0 .09 0.07 40.11 8.98 Elev 264.15 274.14 Expan . . 5 Channel 0.050 50.00 211.16 211.16 671. 43 24.00 3.18 8.80 24707.0 27.03 0.36 1.15 19.99 1. 06 Right OB 0.080 50.00 851.70 851.70 961.95 254.38 1 .13 3.35 35397.7 254.45 0.15 0.17 26.28 5 .13 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: S.F. Main INPUT Description: This is a RIVER: S.F. LICK CREEK RS: 2540. REPEATED section. U.S. OF SH 6 CULVERT Station Elevation Data num= 7 Sta El ev Sta Elev Sta Elev 1000 275.41 1240 275.41 1240 260.94 1272 275.41 1500 275.41 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .08 1240 . 013 1272 .08 Bank Sta: Left Right Lengths: Left Channel 1240 1272 302 302 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1240 275.41 1272 1500 275.41 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 274.26 Element Vel Head (ft) 0.37 Wt. n-Val . w.s. Elev (ft) 273.89 Reach Len. Crit W.S. (ft) 265.93 Flow Area Sta 1250 Right 302 (ft) (sq ft ) E.G. Slope (ft/ft) 0.000132 Area (sq ft) Q Total (cfs) 2025.00 Flow (cfs) Top Width (ft) 32.00 Top Width (ft) El ev Sta 260.94 1272 Coeff Contr . .3 Left OB 302.00 Elev 260.94 Expan. .5 Channel 0.013 302.00 414.42 414 .42 2025.00 32 .00 Right OB 302.00 Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Vel Total (f t/sl Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Al pha Frctn Loss (ft) C & E Loss (ft) 4.89 12.95 175925 .6 302.00 260.94 1. 00 Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) CULVERT REACH: S.F. Main RI VER: S.F. LI CK CREEK RS: 2375. INPUT Description: SH 6 CULVERT Distance from Upstream XS 0 Deck/Roadway Width 302 Weir Coeffi c i ent 3 Bridge Deck/Roadway Skew Upstream Deck/Roadway Coordinates num= 2 Sta Hi Cord Lo Cord 1240 275.41 Sta Hi Cord Lo Cord 1272 275.41 Upstream Bridge Cross Section Data Station Elevation Data num= Sta Elev Sta Elev 1000 275.41 1240 275.41 1272 275.41 Manning's n Values Sta n Val 1000 .08 1500 275.41 Sta 1240 num= n Val . 013 7 Sta 1240 3 Sta 1272 Bank Sta: Lef t 1240 Ineffective Flow Sta L Sta R Right 1272 Coeff Contr. . 3 1000 1240 num= Elev 275.41 Sta L 1272 2 Sta R 1500 Downstream Deck/Roadway Coordinates num= 2 Elev 260.94 n Val .08 Expan. .5 Elev 275.41 Sta Hi Cord Lo Cord 1240 275.41 Sta Hi Cord Lo Cord 1272 275.41 Downstream Br idge Station Elevation Sta Elev 1000 275.41 1272 275 .41 Manning's n Values Sta n Val 1000 .08 Cross Section Data Data Sta 1240 num= Elev 275.41 1500 275.41 num= Sta n Val 1240 . 013 7 Sta 1240 3 Sta 1272 Bank Sta: Left Right Coef f Contr. 1240 1272 .3 Ineffective Flow num= 2 Sta L Sta R El ev Sta L Sta R 1000 1240 275.41 1272 1500 El ev 260.94 n Val .08 Expan. .5 Elev 275.41 Sta 1250 Sta 1250 Elev 260.94 El ev 260.94 39.81 8.82 Sta 1272 Sta 1272 4.89 12.95 175925.6 57.90 0 .06 0.29 19.63 1.03 Elev 260.94 Elev 260.94 Upstream Embankment side slope Downstream Embankment side slope Maximum allowable submergence for weir f l ow Elevation at which weir flow begins 0 horiz. to 1.0 vertical 0 horiz. to 1.0 vertical .95 Energy head used in spillway design Spillway height used in design Weir crest shape Number of Cul verts 1 275.41 Broad Crested 25.79 4.98 Culvert Name Shape Rise Hwy 6 S Box 10 FHWA Chart # B -flared wingwalls Span 10 FHWA Scale # 1 -Wingwall flared 30 to 75 deg. Solution Criteria = Highest U.S. EG Culvert Upstrm Dist Length n Value Entrance Loss Coef . 5 1 324 .014 Number of Barrels = 3 Upstream Elevation 260.94 Centerline Stations Sta. Sta. Sta. 1245 1255.5 1266 Downstream Elevation = 260.94 Centerline Stations Sta. Sta. Sta. 1245 1255.5 1266 CULVERT OUTPUT Profile #PF 1 Culvert ID : Hwy 6 S Culv Q (cfs) 2025.00 # Barrels 3 Q Barrel (cfs) 675.00 E.G. us. (ft) 274.27 w.s . us. (ft) 273.B9 Delta EG (ft) O.BB Delta WS (ft ) l. 07 E.G. IC (ft ) 269.31 E.G. oc (ft ) 274.27 Culvert Control Outlet Culv WS In (ft) 270.94 Culv ws Out (ft) 270 .94 Culv Nml Depth (ft) Culv Crt Depth (ft) 5.21 Culv Ful Lngh (ft) 324 .00 CROSS SECTION RIVER: S.F. REACH: S.F. Main RS: 2210. INPUT Description: Station Elevation Data num= Sta Elev Sta Elev Culv Vel In (ft/s) Culv Vel Out (ft/s ) Culv Inv El Up (ft) Culv Inv El Dn (ft) Culv Frctn Ls (ft) Culv Ext Lss (ft) Culv Ent Lss (ft) Q Weir (cfs) Weir Sta Lft (ft) Weir Sta Rgt (ft) Weir Submerg Weir Max Depth (ft) Weir Avg Depth (ft) Wr Flw Area (sq ft) Min Top Rd (ft) LICK CREEK 7 Sta Elev Sta Exit Loss Coef 1 6.75 6.75 260.94 260.94 0.39 0.14 0.35 275.41 Elev Sta Elev 1000 275.41 1240 275 .41 1240 260.94 1250 260.94 1272 260.94 1272 275.41 1500 275 .41 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .OB 1240 . 013 1272 .OB Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1240 1272 160 160 160 .3 . 5 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1240 275.41 1272 1500 275.41 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 273.39 Element Left OB Channel Vel Head (ft) 0.57 Wt. n-Val . 0.013 w.s. Elev (ft) 272. B2 Reach Len. (ft) 160.00 160.00 Crit W.S. (ft) 266.35 Flow Area (sq ft) 3B0.14 E.G. Slope (ft/ft) 0.000216 Area (sq ft) 3B0 .14 Q Total (cfs) 2297.00 Flow (cfs) 2297.00 Top Width (ft) 32.00 Top Width (ft) 32.00 Vel Total (ft/s) 6.04 Avg. Vel. (ft/s) 6.04 Max Chl Dpth (ft) 11. BB Hydr. Depth (ft) 11. BB Conv. Total (cfs) 156225.4 Conv . (cfs) 156225 .4 Length Wtd. (ft) 160.00 Wetted Per . (ft) 55 .76 Right OB 160.00 Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 260.94 1. 00 0.06 0.23 Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) 39.81 8 .82 0.09 0.56 16.88 0 .81 25.79 4.98 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: S.F. Main INPUT Description: Station Elevation Sta Elev Data RIVER: S.F. LICK CREEK RS: 2050. num= 9 Sta Elev Sta Elev Sta Elev Sta 850 274 1000 272 1110 267 1118 263 .13 1141 1152 267.09 1188 Manning's n Values Sta n Val Sta 850 .08 1110 Bank Sta: Left 1110 Right 1152 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) 268.55 1258 270 1500 num= 3 n Val Sta n Val .05 1152 .08 Lengths: Left Channel Right 700 810 890 Profile #PF 1 273.10 0.10 272. 99 0.000698 2297.00 513.69 1. 51 10.34 86922.9 837.92 262 .65 2.92 0.56 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (l b/ft s) Cum Volume (acre-ft) Cum SA (acres) CROSS SECTION REACH: S.F. Main RIVER: S.F. LICK CREEK RS: 1060 INPUT Description: new x-section added Station Elevation Data num= Sta Elev Sta Elev 1000 274 1055 272 1280 1355 264 270 Manning's n Values Sta n Val 1000 .08 1290 1390 Sta 1260 261 272 num= n Val .05 3/25/00 by JST 14 Sta Elev 1158 270 1300 1420 3 Sta 1318 264 274 n Val .08 Sta 1188 1318 1445 Bank Sta: Left 1260 Right 1318 Lengths: Left Channel Right 0 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Profile #PF 1 272.53 0.10 272.43 0.000648 2297.00 0 0 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) 274 Coeff Contr. .1 Elev 268 266 276 Left OB 0 .080 810.00 421.39 421.39 358.49 184.55 0.85 2.28 13566.l 184.67 0 .10 0.08 39 .04 8.48 Sta 1260 1335 Coeff Contr. .1 Left OB 0.080 1280.00 644.50 644.50 629.36 Elev 262 .65 Expan . . 3 Channel 0 .050 890.00 385.19 385.19 1289.72 42.00 3.35 9.17 48805.4 43.75 0.38 1.29 15.47 0.67 Elev 266 268 Expan . . 3 Channel 0.050 1280.00 481.16 481.16 1472.81 Right OB 0.080 700.00 717.76 717. 76 648.79 287.14 0.90 2.50 24551. 4 287.21 0 .11 0.10 24.47 4 .45 Right OB 0.080 1280.00 212.64 212.64 194.82 Top Width (ft) 353.43 Top Width (ft) 216.93 58.00 78.51 Vel Total (ft/s) 1.72 Avg. Vel. (ft/s) 0.98 3 .06 0.92 Max Chl Dpth (ft) 11.43 Hydr. Depth (ft) 2 .97 8.30 2.71 Conv. Total (cfs) 90261.5 Conv. (cfs) 24731.1 57874.7 7655.7 Length Wtd. (ft) 1280.00 Wetted Per. (ft) 217.05 59.09 78.79 Min Ch El (ft) 261.00 Shear (lb/sq ft) 0.12 0.33 0 .11 Alpha 2.15 Stream Power (l b/ft s) 0 .12 1. 01 0.10 Frctn Loss (ft) 1.33 Cum Volume (acre-ft) 20.79 8.94 10.56 C & E Loss (ft) 0.01 Cum SA (acres) Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1.4 . This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect INPUT Description: Station Elevation Data Sta Elev Sta 633 274.6 708 976 271. 8 1006 1254 269.7 1318 1503 269.2 1585 1746 263.6 1750 1760 259.1 1769 1833 265.2 1856 1958 269.3 1983 2175 274.l 2264 Manning's n Val ues Sta n Val Sta 633 .07 1746 Bank Sta: Left 1746 Right 1769 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) RS: 58600 num= 44 Elev Sta Elev Sta Elev Sta 273 799 272.7 805 272.7 915 271. 5 1089 270 1147 270 1171 270.3 1337 270.4 1420 269.8 1489 268.5 1660 266.7 1668 266.4 1700 259.3 1751 258.6 1756 257 .9 1759 263.5 1810 264.5 1812 264.5 1818 265.5 1871 265.7 1888 266.6 1904 270 2063 271. 8 2079 272.3 2162 275.4 2271 275.6 2367 278 num= 3 n Val Sta n Val .065 1769 .07 Lengths: Left Channel Right 1083.3 Coeff Contr. .1 1050 1300 Profile #PF 1 271. 20 0.08 271.12 0.001351 4905.00 1005.91 1.75 13.22 133436.2 1115. 76 257.90 1.64 1.61 0.00 Element Wt. n-Val . Reach Len. (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs) Top Width (ft) Avg . Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.070 1050.00 1541.18 1541.18 1998.92 719. 06 1.30 2.14 54378.8 719. 18 0.18 0.23 2777.78 668.53 Elev 272.2 269.9 269.3 264.4 258.6 263.8 267.8 273.9 Expan . .3 Channel 0.065 1300. 00 254 .50 254 .50 969.69 23.00 3.81 11. 07 26379.5 26.36 0.81 3.10 727.33 62.36 Right OB 0.070 1083.30 1012.82 1012.82 1936.39 263.85 1.91 3 .84 52677.8 264.08 0.32 0 .62 3353.68 743.60 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross sect ion. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 57300 INPUT Description: Station Elevation Data num= 44 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 725 271. 9 792 271 873 270 .1 878 270.l 977 269.8 1032 269.5 1059 269.3 1135 268.l 1185 268 1207 268 1281 1504 1722 1736 1811 1937 2156 267.8 266.8 262 257.l 263.9 268.l 274 Manning's n Values Sta n Val 725 . 085 1339 1578 1726 1746 1833 1963 2247 268.l 266.2 257 261.6 264.1 268.9 275.6 num= Sta n Val 1722 .065 1356 1645 1727 1787 1849 2040 2253 3 Sta 1746 268.l 264.7 256 .4 263.3 264.3 271. 3 275.8 n Val .085 1430 1652 1733 1789 1866 2059 2350 267.5 264.5 255.8 263.3 265 271. 9 278.3 1492 1680 1735 1795 1882 2143 Bank Sta: Left 1722 Right 1746 Lengths: Left Channel Right 1083 Coeff Contr. .l CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Cri t W. S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd . (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 1050 1300 Profil e #PF 1 269.59 0.09 269.50 0.001555 4905.00 949.85 1. 68 13. 70 124369.7 1120.41 255.80 2.00 1.80 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.085 1050.00 1689.49 1689 .49 2116. 52 689.67 1.25 2.45 53665.9 689.77 0.24 0.30 2738.85 651. 55 266 .8 262 .9 256.6 262.8 266 .2 273.8 Expan. .3 Channel 0.065 1300.00 273.89 273.89 1133.85 24.00 4 .14 11. 41 28749.5 27.84 0.96 3.96 719.45 61.66 Right OB 0.085 1083.00 949.66 949.66 1654.63 236.17 1.74 4 .02 41954.3 236.38 0.39 0.68 3329.28 737.38 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 56000 INPUT Description: Station Elevation Sta Elev 817 269.l 1088 267.2 1308 265.8 1505 1698 1712 1788 1916 2138 264.4 260.4 255 262 .5 266.8 274 Manning's n Values Sta n Val 817 .085 Data Sta 876 1112 1359 1571 1702 1722 1811 1942 2229 num= Elev 268 .4 267 .l 266 263.9 254.8 259 .6 262.7 267.9 275.8 num= Sta n Val 1698 .065 44 Sta 948 1177 1374 1630 1703 1764 1827 2020 2235 3 Sta 1722 Elev 267.5 266.2 265.9 262.8 254.3 262.l 262.9 270.8 276 n Val .085 Sta 952 1223 1440 1636 1709 1766 1844 2040 2333 Bank Sta: Left 1698 Right 1722 Lengths: Left Channel Right 1083 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S . Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) 1050 1300 Profile #PF 1 267.78 0.10 267.68 0.001669 4905.00 1003.60 1. 71 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Elev 267.5 266 265.l 262.6 253.7 262.l 263.5 271. 5 276.7 Sta 1040 1243 1495 1661 1711 1772 1860 2124 Coeff Contr. .1 Left OB 0.085 1050.00 1720.76 1720 .76 2110.24 764.71 1. 23 Elev 267.3 266 264 .4 261.3 254.6 261 .7 264 .5 273.7 Expan. .3 Channel 0.065 1300. 00 279.36 279.36 1200.46 24.00 4.30 Right OB 0.085 1083.00 875 .60 875 .60 1594.29 214.89 1.82 Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 13. 98 120056.9 1124.02 253.70 2.15 1.94 0.00 Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) 2.25 51651.2 764.79 0.23 0.29 2697.75 634.02 11.64 29383 .1 28.31 1. 03 4.42 711.19 60.95 4.07 39022.6 215.11 0.42 0.77 3306.59 731.77 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 54700 INPUT Description: Station Elevation Sta Elev 908 266.4 1144 265 1336 263.8 1507 262 1674 258.8 1689 253 1766 261. 2 1894 265.6 2119 273.9 Manning's n Values Sta n Val 908 .085 Data Sta 960 1165 1380 1563 1678 1699 1789 1921 2211 Sta 1674 Bank Sta: Left 1674 Right 1699 CROSS SECTION OUTPUT E.G . Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpt h (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) num= Elev 265.7 264.8 263.8 261.5 252.5 257 .6 261.4 266.8 276 num= n Val .065 44 Sta 1022 1222 1393 1615 1679 1742 1805 2000 2218 3 Sta 1699 Elev 264.9 264.2 263.7 260.8 252.2 260.8 261. 5 270.3 276.2 n Val .085 Sta 1026 1262 1450 1620 1685 1744 1822 2020 2317 Elev 264.8 264.1 262.8 260.7 251.7 260.8 261.9 271.1 279 Sta 1102 1279 1497 1642 1687 1750 1839 2106 Lengths: Left Channel Right 1083 Coeff Contr. .1 1050 1300 Profile #PF 1 265 .84 0 .11 265.73 0.001789 4905 .00 939.08 1. 79 14.03 115964.1 1132. 51 251.70 2.19 2.55 0.01 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.085 1050.00 1673 .74 1673.74 2179.37 716.17 1. 30 2.34 51524.6 716.24 0.26 0.34 2656.83 616.17 Elev 264.9 264 262 259 .7 252.6 260.7 262 .9 273.5 Expan. .3 Channel 0.065 1300.00 293.68 293.68 1306.27 25.00 4.45 11.75 30882.8 29.77 1.10 4.90 702.64 60.21 Right OB 0.085 1083.00 773.95 773.95 1419.37 197.91 1. 83 3 .91 33556.7 198.14 0.44 0.80 3286.08 726.64 Warning: The energy loss was greater than 1 .0 ft (0 .3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect INPUT Description: Station Elevation Sta El ev 1000 263.7 1500 259.6 1665 2000 251 270.7 Manning's n Values RIVER: Lick Creek Main RS: 53400 Data Sta 1130 1600 1676 2100 num= Elev 262.2 258.9 255.6 273.8 num= 19 Sta 1200 1650 1719 2200 3 Elev 262.7 257.2 259.6 276.4 Sta 1300 1654 1800 2300 Elev 262.1 250 .2 260 .3 279.3 Sta 1400 1661 1900 Elev 261.7 249.6 265.8 Sta 1000 n Val .07 Sta 1650 Bank Sta: Left 1650 Right 1676 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S . (ft) E .G . Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) n Val .065 Sta 1676 n Val .075 Lengths: Left Channel Right 480 460 734 Profile #PF 1 263.28 0.19 263.09 0.002927 4905 .00 797.36 2.46 13. 49 90659.3 553.33 249.60 2.02 1. 77 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Coeff Contr. .1 Left OB 0.070 460.00 1144. 28 1144.28 2028.29 596. 72 1. 77 1.92 37489.0 596.78 0.35 0.62 2622.87 600.35 Expan. . 3 Channel 0.065 734.00 288.62 288.62 1571.40 26.00 5.44 11 .10 29044.2 31.25 1.69 9.19 693 .95 59. 45 Right OB 0.075 480.00 560.34 560.34 1305 .31 174.64 2.33 3 .21 24126.1 174.91 0.59 1.36 3269.50 722.01 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect INPUT Description: Station Elevation Sta El ev 1000 262 .l 1236 1537 1601 1702 1723 1935 1984 2197 260.6 257.8 255 .9 249.2 254.3 263.l 263.4 271. 3 Manning's n Val ues Sta n Val 1000 .085 RIVER: Lick Creek Main RS : 52666 Data Sta 1079 1314 1541 1611 1703 1759 1938 1993 2224 num= El ev 261 260.2 257 .8 257.l 248 .8 257.5 263.l 265.2 272 num= Sta n Val 1698 .065 43 Sta 1107 1322 1559 1628 1705 1765 1949 2033 2320 3 Sta 1723 Elev 260.8 260.2 256 .3 257.l 248.2 258 263 .l 266.9 274.5 n Val .085 Sta 1157 1393 1561 1644 1713 1830 1955 2075 El ev 260.7 259.9 256.8 257 249. 4 258.6 262.4 268.1 Sta 1215 1429 1593 1698 1719 1842 1972 2129 Bank Sta: Left 1698 Right 1723 Lengths: Left Channel 460 734 Right 480 Coeff Contr. .1 CROSS SECTION OUTPUT E .G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) Profile #PF 1 261.51 0.21 261.30 0.003488 4905.00 839.22 2.32 13 .10 83048.3 552 .13 248.20 2.49 1.93 0.00 Element Wt. n -Val. Reach Len . (ft) Fl ow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft ) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.085 460 .00 1325.33 1325.33 2221.66 640.33 1.68 2.07 37615 .7 640.65 0. 45 0.76 2609 .83 593.82 Elev 260.7 259.7 257 255.5 251.7 258.7 262.7 269.6 Expan. .3 Channel 0.065 734.00 271.33 271. 33 1593 .29 25.00 5.87 10.85 26976.6 29.91 1.98 11. 60 689.24 59.02 Right OB 0.085 480.00 513 .42 513. 42 1090.05 173.89 2.12 2.95 18456.0 174.12 0.64 1.36 3263.58 720. 09 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect INPUT Description: Station Elevation Sta Elev 1000 260.6 1252 258.5 1573 256 .l 1642 252.6 1749 248.2 1771 253 1973 2020 2223 260.5 258.6 267 Manning's n Val ues Sta n Val 1000 .085 RIVER: Lick Creek Main RS: 51932 Data Sta 1084 1336 1578 1653 1751 1805 1975 2028 2249 Sta 1745 num= Elev 259.4 258.2 256.1 255 247.6 256 260.4 261.7 267.5 num= n Val .065 43 Sta 1115 1344 1597 1671 1757 1810 1986 2066 2340 3 Sta 1771 Elev 259.1 258.2 253.1 255.2 246.8 256.3 259.8 263.1 269.6 n Val .085 Sta 1160 1420 1599 1688 1760 1872 1992 2106 Elev 259.1 258 254.2 255.1 247.8 257 258.1 264.l Sta 1229 1459 1634 1745 1766 1884 2008 2158 Bank Sta: Left 1745 Right 1771 Lengths: Left Channel 460 734 Right 480 Coeff Contr. .1 CROSS SECTION OUTPUT E .G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) Profile #PF 1 259.58 0.20 259.38 0.003488 4905 .00 892.00 2.26 12.58 83050.5 544.77 246.80 2 .50 2 .01 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (l b/ft s) Cum Volume (acre-ft) Cum SA (acres) Warning: Divided flow computed for this cross-section. Left OB 0.085 460.00 1414.48 1414.48 2427.66 658.82 1. 72 2.15 41104.6 659.96 0.47 0.80 2595.36 586.96 Elev 258.8 257.8 254.9 253.8 249.7 257.1 257.7 265.5 Expan. .3 Channel 0.065 734.00 269.70 269.70 1558. 13 26.00 5 .78 10.37 26382.0 30.47 1. 93 11.14 684.68 58.59 Right OB 0 .085 480.00 489.22 489 .22 919.21 207 .18 1. 88 2.36 15563.9 207.73 0.51 0.96 3258.06 717. 99 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect INPUT Description: Station Elevation Sta Elev 1000 259 1268 256.5 1610 1683 1797 1818 2011 2055 2249 254.3 249.3 247.2 251.7 257.9 253.9 262 .7 Manning's n Values Sta n Val 1000 .085 RIVER: Lick Creek Main RS: 51198 Data Sta 1089 1357 1615 1695 1799 1850 2013 2063 2273 Sta 1793 num= Elev 257.9 256.3 254.3 252.9 246.4 254.4 257.7 258.2 263.1 num= n Val .065 43 Sta 1122 1366 1635 1714 1804 1856 2023 2100 2360 3 Sta 1818 Elev 257.5 256.3 249.9 253.3 245.5 254.7 256.6 259.3 264.8 n Val .085 Sta 1179 1446 1637 1732 1808 1915 2028 2137 Elev 257.4 256.1 251.6 253.1 246.3 255.5 253 .9 260.1 Sta 1244 1488 1674 1793 1814 1926 2044 2186 Elev 256 .8 255 .8 252 .7 252 247.7 255.5 252.8 261.3 Bank Sta: Lef t Right Lengths: Left Channel Right Coef f Contr. Expan. 1793 1818 460 734 480 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 257.56 El ement Left OB Channel Right OB Vel Head (f t) 0.19 Wt. n-Val. 0.085 0.065 0.085 w.s. Elev (ft) 257.37 Reach Len. (ft) 460.00 734.00 480.00 Crit W.S. (ft) Flow Area (sq ft) 1476.00 248.06 504.25 E.G. Slope (ft/ft) 0.003899 Area (sq ft ) 1476.00 248.06 504.25 Q Total (cfs) 5324.00 Flow (cfs ) 2894.97 1468 .27 960 . 76 Top Width (ft) 855.18 Top Width (ft ) 610.57 25.00 219.61 Vel Total (ft/s) 2.39 Avg. Vel. (ft /s) 1. 96 5.92 1. 91 Max Chl Dpth (ft) 11 . 87 Hydr. Depth (ft) 2 .42 9.92 2.30 Conv. Total (cfs ) 85258.3 Conv. (cfs) 46360.0 23512.8 15385 .6 Length Wtd. (ft) 537.00 Wetted Per . (ft) 612.87 29.38 221.45 Min Ch El (ft) 245.50 Shear (lb/sq ft) 0.59 2.06 0.55 Alpha 2.17 Stream Power (lb/ft s) 1.15 12.17 1. 06 Frctn Loss (ft) 2.17 Cum Volume (acre-ft) 2580.10 680.32 3252.58 C & E Loss (ft) 0.00 Cum SA (acres) 580.26 58.16 715.64 Warning: Divided flow computed for this cross-section. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RI VER: Lick Creek Main REACH: Fema X-sect RS: 50464 INPUT Description: Station Elevation Data num= 43 Sta El ev Sta Elev Sta Elev Sta El ev Sta Elev 1000 257.5 1095 256.3 1129 256 1189 255.7 1259 254.9 1284 254.3 1379 254.3 1388 254.3 1473 254 .l 1517 253.8 1646 252 .6 1652 252.6 1673 246 .8 1676 248.9 1715 250 .5 1724 246 1736 250.9 1757 251 .4 1776 251 .2 1840 250.3 1845 246.2 1846 245 .l 1852 244 .l 1856 244 .7 1861 245 .8 1866 250.4 1896 252.9 1901 253 1957 253.9 1968 253.9 2048 255.3 2050 255 2060 253.3 2065 249.6 2080 247 .9 2091 249 .l 2098 254.8 2133 255.5 2169 256.1 2215 257 .l 2274 258.3 2298 258.7 2380 259.9 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .085 1840 .065 1866 .085 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1840 1866 460 734 480 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 255.39 Element Left OB Channel Right OB Vel Head (f t) 0.18 Wt. n-Val. 0.085 0.065 0.085 w.s. Elev (ft) 255 .21 Reach Len . (ft) 460.00 734.00 480.00 Crit W.S. (ft) Flow Area (sq ft) 1472.44 236.64 507.65 E.G. Slope (ft/ft) 0 .004138 Area (sq ft) 1472.44 236.64 507.65 Q Total (cfs) 5324.00 Flow (cfs) 2973 .98 1379.19 970.84 Top Width (ft) 881.10 Top Width (ft) 608.22 26.00 246 .88 Vel Total (f t/s ) 2.40 Avg. Vel. (ft/s) 2.02 5.83 1.91 Max Chl Dpth (ft) 11.11 Hydr. Depth (ft) 2.42 9.10 2.06 Conv. Total (cfs) 82759.6 Conv. (cfs) 46229.3 21438.9 15091.3 Length Wtd. (ft) 524.93 Wetted Per. (ft) 611. 76 29.99 250.58 Min Ch El (ft) 244.10 Shear (lb/sq ft) 0.62 2.04 0.52 Alpha 2.04 Stream Power (lb/ft s) 1 .26 11. 88 1. 00 Frctn Loss (ft) 1 .56 Cum Volume (acre-ft ) 2564.54 676.23 3247.01 C & E Loss (ft) 0.03 Cum SA (acres) 573.82 57.73 713.07 Warning: Divided flow computed for this cross-section. Warning : The energy loss was greater t han 1.0 ft (0.3 m). between the current and prev ious cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 49730 INPUT Description: Station Elevation Data Sta Elev 1000 255.9 1500 252.2 1765 242.7 1900 242.7 2086 252.7 2133 251.3 Manning's n Values Sta n Val 1000 .085 Sta 1100 1689 1778 1909 2095 2200 Sta 1888 Bank Sta: Left 1888 Right 1913 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) num= Elev 254.7 250.8 248 243.8 250 252.l num= n Val .065 29 Sta 1200 1711 1800 1913 2102 2300 3 Sta 1913 Elev 254 243.6 249.5 249.l 245.3 254.8 n Val .085 Sta 1300 1714 1888 1942 2116 2400 Elev 252.5 246.3 248.6 251. 3 243 255.1 Sta 1400 1755 1894 2000 2126 Lengths: Left Channel 266.7 610 Right 516 Coeff Contr. .1 Profile #PF 1 253.81 0.08 253. 72 0.002242 5324 .00 1041.43 1.80 11.02 112435.8 424.62 242 .70 1.68 1. 07 0.01 Element Wt. n-Val. Reach Len . (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.085 266.70 1883 .09 1883.09 3091.50 669.39 1 .64 2.81 65288.3 674.20 0.39 0.64 2546.82 567.08 Elev 252.4 248.3 243.9 252.3 244.3 Expan. . 3 Channel 0.065 610 .00 230.67 230.67 984.87 25 .00 4.27 9 .23 20799.1 29. 45 1.10 4.68 672.30 57.31 Right OB 0.085 516.00 842.56 842.56 1247.64 347.03 1.48 2.43 26348.4 352.15 0.33 0.50 3239.57 709.79 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 49120 INPUT Description: Station Elevation Sta Elev 1000 258.4 1268 256.4 1601 1673 1792 1858 2038 2088 2305 253.9 249.4 247.2 248.3 250.9 245.4 254.l Data Sta 1089 1357 1615 1682 1800 1865 2052 2096 2430 Manning's n Values Sta n Val Sta 1792 1000 .085 Bank Sta: Left 1792 Right 1822 CROSS SECTION OUTPUT num= Elev 257.8 256.2 253.3 245 243 248.3 249.2 250.l 256.7 num= n Val .065 42 Sta 1132 1396 1634 1694 1808 1930 2058 2151 3 Sta 1822 Elev 257.6 256.l 247.7 249.l 241.1 249.7 246 250.8 n Val .085 Lengths: Left Channel 266.7 610 Profile #PF 1 Sta 1178 1446 1637 1714 1817 1937 2075 2180 Right 516.7 Elev 257.4 255.8 249.4 248.9 243.2 249.8 244.5 251. 2 Sta 1264 1528 1660 1727 1822 2008 2080 2223 Coeff Contr. .1 Elev 256.5 254.6 249.3 248.4 247.4 250.9 244.8 251.9 Expan. .3 E.G. Elev (ft) 252 .73 Element Left OB Channel Right OB Vel Head (ft) 0.15 Wt. n-Val. 0.085 0.065 0.085 w.s . Elev (ft) 252.57 Reach Len. (ft) 266 .70 610.00 516.70 Crit W.S. (ft) Flow Area (sq ft) 715. 90 274.17 1202 .85 E.G. Slope (ft/ft) 0.002877 Area (sq ft) 715. 90 274 .17 1202 .85 Q Total (cfs) 5324.00 Flow (cfs) 1701.37 1378 .17 2244.46 Top Width (ft) 630.66 Top Width (ft) 174.54 30.00 426 .12 Vel Total (ft/s) 2.43 Avg. Vel. (ft/s) 2.38 5.03 1.87 Max Chl Dpth (ft) 11. 47 Hydr. Depth (ft) 4.10 9.14 2.82 Conv. Total (cfs) 99261. 6 Conv. (cfs) 31720.6 25694.9 41846.l Length Wtd. (ft) 479.84 Wetted Per. (ft) 177.41 33.03 428.46 Min Ch El (ft) 241.10 Shear (lb/sq ft) 0.72 1 .49 0.50 Alpha 1.66 Stream Power (lb/ft s) 1. 72 7.49 0.94 Frctn Loss (ft) 1.21 Cum Volume (acre-ft) 2538.86 668.76 3227.45 C & E Loss (ft) 0.01 Cum SA (acres) 564.49 56 .92 705.21 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect INPUT Description: Station Elevation Sta Elev 1000 260.9 1235 260.4 1528 256.9 1592 250.5 1696 243.8 1774 245.4 1990 249.2 2049 246.5 2310 254.l Manning's n Values Sta n Val 1000 .085 RS: 48510 Data num= Sta Elev 1078 260.9 1314 260 1540 255 .8 1600 248.1 1706 242.l 1783 245.2 2006 248.3 2060 249 2460 258.4 num= Sta n Val 1696 .065 42 Sta 1116 1348 1557 1610 1715 1861 2014 2126 3 Sta 1730 Elev 260.9 259.8 251.8 249. 4 239.6 247.2 246.8 249.8 n Val .085 Sta 1157 1392 1560 1627 1726 1868 2034 2160 Bank Sta: Left 1696 Right 1730 Lengths: Left Channel Right 516.7 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Cri t W. S. (ft) E.G. Slope (ft/ft) Q Total (cf s) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv . Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) 266.7 610 Profile #PF 1 251. 51 Element 0.13 Wt. n-Val . 251.37 Reach Len. (ft) Flow Area (sq ft) 0.002241 Area (sq ft) 5324.00 Flow (cfs) 643.93 Top Width (ft) 2.24 Avg. Vel. (ft/s) 11. 77 Hydr. Depth (ft) 112469.9 Conv. (cfs) 505.00 Wetted Per. (ft) 239.60 Shear (lb/sq ft) 1. 71 Stream Power (lb/ft 0.77 Cum Volume (acre-ft) 0.01 Cum SA (acres) CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 47900 INPUT Description: Station Elevation Data Sta Elev Sta 1000 263 .4 1100 num= Elev 264.2 18 Sta 1200 Elev 264.3 Sta 1300 Elev Sta 260.8 1232 259.3 1464 252.5 1580 248.4 1639 242.7 1730 247.4 1954 246 2040 250 .3 2211 Coeff Contr. .1 s) Elev 263.6 Left OB 0.085 266.70 463.06 463.06 939.84 119. 91 2.03 3.86 19854.l 120.55 0.54 1. 09 2535.25 563.59 Sta 1400 Elev 260.4 258.3 251 .l 247.4 245.6 249.1 246.2 251.1 Expan. .3 Channel 0.065 610.00 320.30 320.30 1492.29 34.00 4.66 9. 42 31524.8 35.85 1. 25 5.82 664.60 56.47 Elev 261.7 Right OB 0.085 516.70 1593.37 1593 .37 2891.87 490.02 1.81 3.25 61091.0 490 .56 0. 45 0.82 3210.87 699 .78 1455 1639 2100 259.9 243.9 248.8 Manning's n Values Sta n Val 1000 .06 1500 1700 2200 252.9 242.1 250.3 num= Sta n Val 1600 .055 1551 1800 2490 3 Sta 1639 246.5 244.9 260 n Val .09 1600 1900 244.4 247 .4 1623 2000 Bank Sta: Left 1600 Right 1639 Lengths: Left Channel 783.3 960 Right 696.7 Coeff Contr. .1 CROSS SECTION OUTPUT E.G. Elev (ft} Vel Head (ft} W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft} Q Total (cfs} Top Width (ft} Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs} Length Wtd. (ft} Min Ch El (ft) Alpha Frctn Loss (ft} C & E Loss (ft} Profile #PF 1 250. 72 0.09 250.63 0. 001110 5324.00 691.78 1.78 12.63 159801.l 804.79 238.00 1. 87 1. 20 0.02 Element Wt. n-Val. Reach Len. (ft} Flow Area (sq ft) Area (sq ft} Flow (cfs} Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs} Wetted Per. (ft} Shear (lb/sq ft} Stream Power (lb/ft s} Cum Volume (acre-ft} Cum SA (acres} Left OB 0.060 783 .30 321.79 321 .79 659.40 81.91 2.05 3 .93 19792.2 82.21 0.27 0 .56 2532.85 562.97 238 247.5 Expan. .3 Channel 0.055 960.00 371.77 371.77 1456.85 39.00 3.92 9 .53 43727.7 40.93 0.63 2.47 659.75 55.96 Right OB 0.090 696. 70 2302.10 2302 .10 3207.75 570.87 1 .39 4.03 96281. 3 570.99 0.28 0.39 3187.76 693 .49 Warning: The energy loss was greater than 1.0 ft (0 .3 m}. between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect INPUT Description: Station Elevation Sta Elev 1000 257.9 1261 257.3 1456 256.l 1652 1819 1906 2220 251.4 243.3 242.7 250.5 Manning's n Values Sta n Val 1000 .06 RIVER: Lick Creek Main RS: 46940 Data Sta 1065 1273 1521 1682 1833 1984 2299 num= Elev 257.7 257.1 255.6 248 .9 237.7 245.5 252.2 num= Sta n Val 1819 .055 34 Sta 1130 1326 1546 1717 1841 2063 2307 3 Sta 1858 Elev 257.8 256.3 255.4 246.5 235.9 248.l 252.5 n Val .09 Sta 1136 1391 1587 1752 1847 2088 2527 Elev 257.8 256.l 254.8 244.4 237.6 248.4 259.9 Sta 1196 1409 1621 1782 1858 2141 Bank Sta: Left 1819 Right 1858 Lengths: Left Channel 783.3 960 Right 696.7 Coeff Contr. .1 CROSS SECTION OUTPUT E.G. Elev (ft} Vel Head (ft) W.S. Elev (ft} Cri t W. S. (ft} E.G. Slope (ft/ft) Q Total (cfs} Top Width (ft} Vel Total (ft/s} Max Chl Dpth (ft} Conv. Total (cfs) Length Wtd. (ft} Min Ch El (ft} Alpha Frctn Loss (ft} Profile #PF 1 249.51 0.24 249.26 0 .002108 5324 .00 481. 23 2 .79 13 .36 115953. 0 851.52 235.90 2.01 2.91 Element Wt. n-Val. Reach Len. (ft} Fl ow Area (sq ft } Area (sq ft) Flow (cfs} Top Width (ft) Avg. Vel. (ft/s) Hydr . Depth (ft) Conv. (cfs} Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft} Left OB 0.060 783.30 555.10 555 .10 1569.93 141.35 2.83 3.93 34191.9 141.52 0.52 1.46 2524.97 Elev 257.9 256.2 254 243.8 243.3 248.9 Expan. .3 Channel 0.055 960.00 394.37 394.37 2180.71 39.00 5.53 10.11 47494.3 41.90 1. 24 6.85 651.31 Right OB 0.090 696.70 958 . 72 958.72 1573.37 300.88 1.64 3.19 34266.8 300.98 0.42 0.69 3161.69 C & E Loss (ft) 0.05 Cum SA (acres) 560 .97 55.10 686.52 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 45980 INPUT Description: Station Elevation Data num= 34 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 252.5 1083 251 .6 1165 251.4 1173 251.4 1248 251.5 1330 250.2 1346 249.9 1413 248.6 1496 248.5 1519 248.7 1578 249.2 1661 249.1 1692 249.l 1743 248.9 1787 248.1 1826 246.5 1864 244.9 1908 243.3 1953 242.3 1991 242 2037 242.2 2051 235.l 2058 233.7 2065 235.1 2076 242.7 2111 243.2 2168 246 2226 248.7 2244 249.3 2283 250.3 2340 252.2 2397 254 .l 2404 254.4 2563 259.7 Manning 's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .06 2037 .055 2076 .09 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 2037 2076 783.3 960 696.7 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 246.55 Element Left OB Channel Right OB Vel Head (f t) 0. 71 Wt . n-Val. 0.060 0.055 0 .090 w.s. Elev (ft) 245.84 Reach Len. (ft) 783.30 960.00 696.70 Crit W.S. (ft) Flow Area (sq ft) 536.73 337.28 172.37 E.G. Slope (ft/ft) 0.006454 Area (sq ft) 536.73 337.28 172 .37 Q Total (cfs) 5324.00 Flow (cfs) 2093.93 2874.52 355.55 Top Width (ft) 323.21 Top Width (ft) 195.40 39.00 88.81 Vel Total (ft/s) 5.09 Avg. Vel. (ft/s) 3.90 8.52 2.06 Max Chl Dpth (ft) 12.14 Hydr. Depth (ft) 2.75 8.65 1.94 Conv. Total (cfs) 66273.2 Conv. (cfs) 26065.2 35782.0 4425.9 Length Wtd. (ft) 846.05 Wetted Per. (ft) 195.46 43.34 88.88 Min Ch El (ft) 233 .70 Shear (lb/sq ft) 1.11 3.14 0.78 Alpha 1.76 Stream Power (lb/ft s) 4.32 26. 72 1.61 Frctn Loss (ft) 1.29 Cum Volume (acre-ft) 2515 .15 643.25 3152.64 C & E Loss (ft) 0 .20 Cum SA (acres) 557.94 54.24 683.40 Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections . Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 45020 INPUT Description: Station Elevation Data num= 21 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 247 1100 245.5 1200 245 1300 245.2 1400 243.2 1500 240.8 1600 240.9 1700 242.3 1800 242.7 1900 243 2000 241. 6 2100 240.l 2200 240.2 2256 241.1 2269 232.6 2276 231. 6 2283 232.6 2295 242 2400 250.3 2500 256 .2 2600 259.6 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .06 2256 .055 2295 .09 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 2256 2295 900 1170 750 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 245.06 Element Left OB Channel Right OB Vel Head (ft) 0.05 Wt. n-Val. 0.060 0.055 0.090 w.s. Elev (ft) 245.01 Reach Len. (ft) 900.00 1170.00 750.00 Crit W.S. (ft) Flow Area (sq ft) 3024.54 379.36 57.33 E.G . Slope (ft/ft) 0.000666 Area (sq ft) 3024.54 379.36 57.33 Q Total (cfs) 5324.00 Flow (cfs) 4194 .70 1097.28 32.02 Top Width (ft) 1030.94 Top Width (ft) 953.85 39.00 38.08 Vel Total (ft/s) 1 .54 Avg. Vel. (ft/s) 1.39 2.89 0.56 Max Chl Dpth (ft) 13.41 Hydr. Depth (ft) 3.17 9.73 1. 51 Conv. Total (cfs) 206232.8 Conv. (cfs) 162487.7 42504.6 1240 .5 Length Wtd. (ft) 968.04 Wetted Per. (ft) 953.94 44.92 38.20 Min Ch El (ft) 231.60 Shear (lb/sq ft) 0 .13 0.35 0.06 Alpha 1. 37 Stream Power (lb/ft s) 0.18 1. 02 0.03 Fr ctn Loss (ft) 0.80 Cum Volume (acre-ft) 2483.13 635.35 3150.81 C & E Loss (ft) 0.00 Cum SA (acres) 547.60 53.38 682.39 Warning: Divided flow computed for this cross-section. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1 .4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 43850 INPUT Description: Station Elevation Data num= 30 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 251 1110 249.6 1220 248.6 1330 248.1 1404 246.9 1439 245.9 1549 242.4 1642 240.4 1659 240.4 1768 240.6 1879 240.2 1989 239.9 2010 239.6 2099 239.l 2209 238.4 2316 238.6 2380 239.l 2391 237 2402 232.6 2414 229 .8 2418 230.4 2433 232.3 2456 238.2 2465 239.6 2598 242 .3 2916 247.9 3181 252 3345 253.l 3690 254.5 3775 259.8 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 2380 .06 2465 .09 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 2380 2465 900 1170 730 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 244.26 Element Left OB Channel Right OB Vel Head (ft) 0.08 Wt. n-Val. 0.075 0.060 0.090 w.s . Elev (ft) 244.18 Reach Len. (ft) 900.00 1170.00 730.00 Crit W.S. (ft) Flow Area (sq ft ) 3713. 83 827.78 529.17 E.G. Slope (ft/ft) 0.000947 Area (sq ft) 3713. 83 827.78 529.17 Q Total (cfs) 9161.00 Flow (cfs) 5881.37 2823.78 455 .86 Top Width (ft) 1211. 42 Top Width (ft) 886.84 85.00 239.58 Vel Total (ft/s) 1.81 Avg. Vel. (ft/s) 1.58 3.41 0.86 Max Chl Dpth (ft) 14.38 Hydr. Depth (ft) 4.19 9.74 2.21 Conv. Total (cfs) 297750.4 Conv. (cfs) 191156 . 0 91778.2 14816.2 Length Wtd. (ft) 956.82 Wetted Per. (ft) 886.90 87.39 239.62 Min Ch El (ft) 229.80 Shear (lb/sq ft ) 0.25 0 .56 0 .13 Alpha 1.60 Stream Power (lb/ft s) 0.39 1.91 0 .11 Frctn Loss (ft) 0.23 Cum Volume (acre-ft) 2413.52 619.14 3145 .76 C & E Loss (ft) 0.02 Cum SA (acres) 528.59 51.72 680.00 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 42680 INPUT Description: Station Elevation Data num= 14 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 2SS 1440 2SO 1700 240 2110 236.S 2S04 237 2Sl9 237 2SS2 228 2SS9 229 2620 237 263S 237 2870 240 3900 2SO 4800 2SO 49SO 260 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .OS 2S04 . 04S 263S .OS Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 2S04 263S 96 96 96 .4 .6 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 244.01 Element Left OB Channel Right OB Vel Head (ft) 0.02 Wt. n-Val. o.oso 0.04S o.oso W.S. Elev (ft) 243.99 Reach Len. (ft) 96.00 96.00 96.00 Crit W.S. (ft) Flow Area (sq ft) S410.86 1367.39 2108.S7 E.G. Slope (ft/ft) 0.000108 Area (sq ft) S410.86 1367.39 2108.S7 Q Total (cfs) 9161.00 Flow (cfs) SSOl.60 2224.06 143S.34 Top Width (ft) 1684.42 Top Width (ft) 907.68 131. 00 64S.74 Vel Total (ft/s) 1. 03 Avg. Vel. (ft/s) 1.02 1. 63 0.68 Max Chl Dpth (ft) lS.99 Hydr. Depth (ft) S.96 10.44 3.27 Conv. Total (cfs) 880248.4 Conv. (cfs) S28629.3 213702.2 137917.0 Length Wtd. (ft) 96.00 Wetted Per. (ft) 907.77 132. 80 64S .77 Min Ch El (ft) 228.00 Shear (lb/sq ft) 0.04 0.07 0.02 Alpha 1.26 Stream Power (lb/ft s) 0.04 0 .11 0.02 Frctn Loss (ft) 0 .02 Cum Volume (acre-ft) 2319.2S S89.66 3123.6S C & E Loss (ft) 0.41 Cum SA (acres) SlO.OS 48.82 672. S8 Warning: The velocity head has changed by more than O.S ft (O .lS m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 42S84 INPUT Description: Station Elevation Data num= 24 Sta Elev Sta Elev Sta Elev 1 2S7 430 2S2 1000 244.3 lSOO 244.S 1800 244.7 1861 24S 2S04 244.S 2Sl9 237 2S39 232.7 2620 237.l 263S 242 .S 2900 244.9 3400 246.4 3600 247.6 4000 2S2 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1 .OlS 2S04 .02 263S .OlS Bank Sta: Left Right Lengths: Left Channel 2S04 263S 44 44 Ineffective Flow num= 2 Sta L Sta R 1 2S04 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) Elev 244 Sta L Sta R Elev 263S sooo 244 Profile #PF 1 243.S8 1.04 Element Wt. n-Val. Sta Elev Sta 1200 24S 1400 2000 244.9 2300 2SS2 229.2 2S90 3100 244.7 3300 sooo 2S4 Right Coe ff Contr. 44 .4 Left OB Elev 244.8 244.6 230.S 24S.8 Expan. .6 Channel 0.020 Right OB w.s. Elev (ft) 242.54 Reach Len. (ft) 1. 00 1. 00 1. 00 Crit w.s. (ft) 238.56 Flow Area (sq ft) 1121 . 21 E.G. Slope (ft/ft) 0.000691 Area (sq ft) 1121. 21 0 .11 Q Total (cfs) 9161.00 Flow (cfs) 9161 .00 Top Width (ft) 131. 96 Top Width (ft) 127.09 4.87 Vel Total (ft/s) 8.17 Avg. Vel. (ft/s) 8.17 Max Chl Dpth (ft) 13.34 Hydr. Depth (ft) 8.82 Conv. Total (cfs) 348547.7 Conv. (cfs) 348547.7 Length Wtd. (ft) 1. 00 Wetted Per. (ft) 131.00 Min Ch El (ft) 229.20 Shear (lb/sq ft) 0.37 Alpha 1. 00 Stream Power (lb/ft s) 3.02 Frctn Loss (ft) 0.00 Cum Volume (acre-ft) 2313 .29 586.92 3121.33 C & E Loss (ft) 0.09 Cum SA (acres) 509.05 48. 53 671. 86 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. BRIDGE RIVER: Lick Creek Main REACH: Fema X-sect RS: 42583 INPUT Description: Distance from Upstream XS 1 Deck/Roadway Width 43 Weir Coefficient 2.6 Bridge Deck/Roadway Skew Upstream Deck/Roadway Coordinates num= 2 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 1 244.4 242.5 5000 244.4 242.5 Upstream Bridge Cross Section Data Station Elevation Data num= 24 Sta El ev Sta Elev Sta Elev Sta Elev Sta Elev 1 257 430 252 1000 244.3 1200 245 1400 244.8 1500 244.5 1800 244.7 1861 245 2000 244.9 2300 244.6 2504 244 .5 2519 237 2539 232 .7 2552 229.2 2590 230.5 2620 237.l 2635 242.5 2900 244.9 3100 244 .7 3300 245.8 3400 246.4 3600 247.6 4000 252 5000 254 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1 .015 2504 .02 2635 .015 Bank Sta: Left Right Coe ff Contr. Expan. 2504 2635 .4 . 6 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1 2504 244 2635 5000 244 Downstream Deck/Roadway Coordinates num= 2 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 1 244.4 242.5 5000 244.4 242.5 Downstream Bridge Cross Section Data Station Elevation Data num= 30 Sta El ev Sta Elev Sta Elev Sta Elev Sta Elev 1 257 430 252 1000 244.3 1200 245 1400 244 .8 1500 244.5 1800 244.7 1861 245 2000 244.9 2300 244.6 2504 244.5 2519 237.3 2537 233.2 2539 232.7 2539 232 .6 2552 229 .2 2568 229.7 2570 229.8 2590 230.5 2599 232.8 2601 233.4 2625 237 .l 2635 242.5 2900 244.9 3100 244.7 3300 245.8 3400 246 .4 3600 247.6 4000 252 5000 254 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1 .015 2504 .02 2635 .015 Bank Sta: Left Right Coeff Contr. Expan. 2504 Ineffective Flow Sta L Sta R 1 2504 2635 num= Elev 244 Sta L 2635 2 .4 Sta R 5000 .6 Elev 244 Upstream Embankment side slope Downstream Embankment side slope Maximum allowable submergence for weir flow Elevation at which weir flow begins 0 horiz. to 1.0 vertical 0 horiz. to 1.0 v ertical .95 Energy head used in spillway design Spillway height used in design 244.5 Weir crest shape Broad Crested Number of Piers = 3 Pier Data Pier Station Upstream= 2538 Upstream num= 2 Width El ev Width Elev 2 0 2 242.5 Downstream num= 2 Width El ev Width Elev 2 0 2 242.5 Pier Data Pier Station Upstream= 2569 Upstream num= 2 Width Elev Width Elev 2 0 2 242.5 Downstream num= 2 Width Elev Width Elev 2 0 2 242.5 Pier Data Pier Station Upstream= 2600 Upstream num= 2 Width El ev Width Elev 2 0 2 242.5 Downstream num= 2 Width Elev Width Elev 2 0 2 242.5 Number of Bridge Coefficient Sets Low Flow Methods and Data Energy Momen tum Yarnell Cd KVal 1 Downstream= Downstream= Downstream= 1. 2 1. 05 Selected Low Flow Methods Highest Energy Answer High Flow Method Energy Only Additional Bridge Parameters Add Friction component to Momentum Do not add Weight component to Momentum 2538 2569 2600 Class B flow critical depth computations use critical depth i nside the bridge at the upstream end Criteria to check for pressure f l ow = Upstream energy grade line BRIDGE OUTPUT Profil e #PF 1 Opening : Bridge #1 E.G. us. (ft) 243.58 Element Inside BR US w.s. us. (ft) 242.54 E.G. Elev (ft) 243.49 Q Total (cfs) 9161.00 w.s. Elev (ft) 242.24 Q Bridge (cfs) 9161.00 Crit W.S. (ft) 238.90 Q Weir (cfs) Max Chl Dpth (ft) 13.04 Weir Sta Lft (ft) Vel Total (ft/s) 8.98 Weir Sta Rgt (ft) Flow Area (sq ft ) 1020.15 Weir Submerg Froude # Chl 0.54 Inside BR DS 243.42 242 .18 238.88 12.98 8.93 1025.65 0.54 Weir Max Depth (ft) Specif Force (cu ft) 7771. 98 7736.94 Min Top Rd (ft) 244 .50 Hydr Depth (ft) 8.52 8.58 Min El Prs (ft) 242.50 W.P. Total (ft) 186.11 185.06 Delta EG (ft) 0.25 Conv. Total (cfs) 235628.2 238648.6 Delta WS (ft) 0.30 Top Width (ft) 119.76 119.58 BR Open Area (sq ft) 1051.39 Frctn Loss (ft) 0.06 0.00 BR Open Vel (ft/s) 8.98 C & E Loss (ft) 0.01 0.09 Coef of Q Shear Total (lb/sq ft) 0.52 0.51 Br Sel Method Energy only Power Total (lb/ft s) 4.65 4 .55 Note : Yarnell answer is not valid if the water surface is above the low chord or if there is weir flow. The Yarnell answer has been disregarded. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 42540 INPUT Description: Station Elevation Data num= 30 Sta Elev Sta Elev Sta Elev Sta Elev Sta 1 257 430 252 1000 244.3 1200 245 1400 1500 244.5 1800 244.7 1861 245 2000 244.9 2300 2504 244.5 2519 237.3 2537 233.2 2539 232.7 2539 2552 229.2 2568 229.7 2570 229.8 2590 230.5 2599 2601 233.4 2625 237.1 2635 242.5 2900 244.9 3100 3300 245.8 3400 246.4 3600 247.6 4000 252 5000 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1 .015 2504 .02 2635 .015 Bank Sta: Left Right Lengths : 2504 2635 Left Channel 1 1 Right 1 Coeff Contr. .4 Ineffective Flow Sta L Sta R 1 2504 CROSS SECTION OUTPUT E.G . Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) num= 2 Elev Sta L Sta R Elev 244 2635 5000 244 Profile #PF 1 243.33 1.09 242.24 238.57 0.000740 9161.00 125.82 8.37 13 . 04 336687.3 1. 00 229.20 1. 00 0.00 0.01 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Fl ow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (l b/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 1. 00 2313 .29 509.05 Elev 244.8 244.6 232.6 232.8 244.7 254 Expan . . 6 Channel 0.020 1. 00 1094.75 1094.75 9161.00 125.82 8.37 8.70 336687.3 129.99 0.39 3.26 585.88 48 .41 Right OB 1. 00 3121.33 671. 86 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 42539 INPUT Description: Station Elevation Data num= 24 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1 257 430 252 1000 244.3 1200 245 1400 244.8 1500 244.5 1800 244.7 1861 245 2000 244.9 2300 244.6 2504 244.5 2519 237 .3 2539 232 2552 229.2 2590 230.5 2620 3400 237 .l 246.4 Manning's n Values Sta n Val 1 . 05 2635 3600 242.5 247.6 num= Sta n Val 2504 .045 2835 4000 3 Sta 2635 244.5 252 n Val .05 3100 5000 244.7 254 3300 Bank Sta: Left 2504 Ineffective Flow Sta L Sta R Right 2635 Lengths: Left Channel 99 99 Right 99 Coeff Contr. .4 1 2504 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) CROSS SECTION REACH: Fema X-sect INPUT Description: num= 2 Elev Sta L Sta R Elev 244 244 2635 5000 Profile #PF 1 243.33 1.10 242.22 238 .50 0.003808 9161.00 125.48 8.43 13.02 148459.9 99.00 229.20 l. 00 0 .48 0.02 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: Lick Creek Main RS : 42440 Station Elevation Data num= 14 Sta Elev 1000 255 2519 2870 237 240 Manning's n Values Sta n Val 1000 .075 Sta 1440 2552 3900 Elev 250 228 250 num= Sta n Val 2504 .055 Sta 1700 2559 4800 3 Sta 2635 Elev 240 229 250 n Val .075 Sta 2110 2620 4950 Elev 236.5 237 260 Left OB 99.00 2313.29 509.05 Sta 2504 2635 Bank Sta: Left 2504 Ineffective Flow Sta L Sta R Right 2635 Lengths: Left Channel 500 730 Right 900 Coeff Contr. .4 1000 2504 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Cri t W. S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) num= 2 Elev Sta L Sta R Elev 244 244 2635 4950 Profile #PF 1 242.83 1 .15 241.68 238.85 0.006326 9161.00 1386 .11 8.61 13.68 115182. 5 688.14 228.00 l. 00 2.40 0.63 Element Wt . n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 500.00 3381.41 847.56 2309.45 508.09 245.8 Expan. . 6 Channel 0.045 99.00 1087.01 1087.01 9161.00 125.48 8.43 8.66 148459.9 129.22 2.00 16.85 585.86 48.41 Elev 237 237 Expan. . 6 Channel 0.055 730.00 1064.46 1064.46 9161.00 131.00 8.61 8.13 115182. 5 132.80 3.17 27.24 583.41 48.12 Right OB 99.00 3121 .33 671. 86 Right OB 900.00 890.73 407.55 3120.32 671. 40 Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 41710 INPUT Description: Station Elevation Data num= 18 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 255 1500 250 1900 240 3400 236.l 3500 235.9 3600 236.6 3707 235.7 3727 226.7 3733 226 .3 3742 226.7 3757 234.l 3800 235.8 3900 236.l 4000 236 .7 4100 237.8 4200 239.6 4300 245 4400 250 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .085 3707 .07 3757 .085 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan . 3707 3757 600 622 560 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 239.80 Element Left OB Channel Right OB Vel Head (ft) 0.10 Wt. n-Val. 0.085 0.070 0.085 w.s. Elev (ft) 239.70 Reach Len. (ft) 600.00 622.00 560.00 Crit W.S. (ft) Flow Area (sq ft) 3584.21 507.41 1253.57 E.G. Slope (ft/ft) 0.002201 Area (sq ft) 3584.21 507.41 1253.57 Q Total (cfs) 9161.00 Flow (cfs) 4850.70 2259.19 2051. 11 Top Width (ft) 2185.76 Top Width (ft) 1690.94 50.00 444.82 Vel Total (ft/s) 1. 71 Avg. Vel. (ft/s) 1. 35 4.45 1. 64 Max Chl Dpth (ft) 13 .40 Hydr. Depth (ft) 2.12 10.15 2.82 Conv. Total (cfs) 195260.5 Conv. (cfs) 103389.4 48153.2 43717.9 Length Wtd. (ft) 594.99 Wetted Per. (ft) 1690.96 53.68 444.88 Min Ch El (ft) 226.30 Shear (lb/sq ft) 0 .29 1. 30 0.39 Alpha 2.20 Stream Power (lb/ft s) 0.39 5.78 0.63 Frctn Loss (ft) 1. 32 Cum Volume (acre-ft) 2269.47 570 .24 3098.17 C & E Loss (ft) 0.00 Cum SA (acres) 493.52 46.60 662.59 Warning: The energy loss was greater than 1.0 ft (0. 3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 41088 INPUT Description: Station Elevation Data num= 41 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 252 1411 247.6 1735 239.4 1740 239.3 2469 236.l 2974 234.9 3056 234.7 3138 235.3 3226 234.5 3240 227.3 3244 225.5 3249 225.2 3255 225.6 3260 226 3277 233 .3 3302 233.9 3329 234.5 3360 234.4 3419 234.4 3451 234.5 3477 234.7 3535 235 3573 235.3 3594 235.5 3641 236 3650 234.6 3651 236.2 3695 236.4 3710 236.6 3743 237 3766 236.9 3775 236.7 3789 237.4 3798 237.6 3816 237.7 3827 238 3885 240.3 3938 242 .6 3943 242.8 4002 245.5 4060 248.2 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .085 3226 .07 3277 .085 Bank Sta: Left 3226 Right 3277 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S . Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) Lengths: Left Channel Right 560 600 622 Profile #PF 1 238.48 0.10 238.37 0.002242 9161.00 1885.62 1.82 13.17 193471.8 591. 64 225.20 2.00 1. 34 0.00 Element Wt. n-Val . Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (f t) Conv. (cfs) Wetted Per . (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Coeff Contr. . l Left OB 0.085 600.00 2916.58 2916.58 4190.91 1275.18 1.44 2.29 88508.2 1275.19 0.32 0.46 2224.70 473.09 Expan. .3 Channel 0.070 622.00 506.70 506.70 2247.26 51.00 4.44 9 .94 47460.1 54.67 1.30 5.75 563.00 45.88 Right OB 0.085 560.00 1620.69 1620.69 2722.82 559.45 1.68 2.90 57503.5 560.50 0.40 0.68 3079.69 656.14 Warning: The energy loss was greater than 1 .0 ft (0 .3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 40466 INPUT Description: Station Elevation Data Sta Elev 1000 249 2547 2761 2827 3033 3239 3373 3445 233.6 224.4 232.9 233.2 231.7 234.9 236 3720 246 .4 Manning's n Values Sta n Val 1000 .085 Sta 1322 2612 2766 2859 3101 3250 3384 3514 Sta 2745 Bank Sta: Left 2745 Right 2797 CROSS SECTION OUTPUT E .G. Elev (ft) Vel Head (ft) W.S. Elev (ft ) Cri t W. S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd . (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) num= Elev 245.2 233.5 224 233.2 233.4 234.9 234.4 237.9 num= n Val .07 41 Sta 1575 2676 2772 2895 3145 3289 3400 3575 3 Sta 2797 Elev 238.7 233.9 224.6 233 233.9 235 235.7 240.3 n Val .085 Sta 1580 2745 2778 2964 3170 3308 3411 3583 Elev 238.6 233.4 225 .4 232.7 234 .2 235 .1 235 .8 240.5 Sta 2152 2757 2797 3002 3226 3347 3433 3651 Lengths: Left Channel Right 560 Coeff Contr. .1 600 622 Profile #PF 1 237.14 0.10 237.03 0.002287 9161.00 1678.55 1.90 13.03 191554.8 587 .61 224.00 1. 85 1.38 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq f t) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr . Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.085 600.00 2255 .52 2255.52 3377.29 941 .01 1. 50 2.40 70618.6 941.02 0.34 0.51 2189.08 457.83 Elev 234.6 225.8 232.4 233 234.7 235.4 235.8 243.4 Expan. . 3 Channel 0.070 622 .00 504.25 504 .25 2221.20 52.00 4.40 9.70 46444 .9 55.79 1. 29 5.68 555.78 45 .14 Right OB 0.085 560.00 2052.85 2052.85 3562.51 685.54 1. 74 2.99 74491.3 686.44 0.43 0.74 3056.08 648.13 Warning: The energy l oss was greater than 1.0 ft (0 .3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 39844 INPUT Description: Station Elevation Data Sta El ev 1000 246 2121 232.4 2278 223.2 2351 231 .9 2588 231.7 2826 2980 3063 228.9 232 .9 234 3380 244.7 Manning's n Values Sta n Val 1000 .085 Sta 1234 2168 2282 2388 2668 2839 2993 3143 Sta 2265 Bank Sta: Left 2265 Right 2317 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Cri t W. S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpt h (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) num= Elev 242.8 232.2 222.9 231.9 231.9 233.5 232.l 235.5 num= n Val .07 41 Sta 1417 2215 2290 2430 2719 2884 3012 3215 3 Sta 2317 El ev 238 232 .6 223.6 231.6 232.5 233.6 233.9 237 n Val .085 Sta 1420 2265 2295 2509 2747 2905 3024 3222 Elev 237.9 232.2 224.7 231 .l 232.9 233.6 234 238.1 Sta 1835 2275 2317 2553 2811 2950 3049 3301 Lengths: Left Channel Right 560 Coeff Contr. .1 600 622 Profile #PF 1 235.75 0.10 235.65 0.002428 9161.00 1539.62 1.99 12.75 185909.3 582.95 222.90 1 .70 1. 45 0.00 El ement Wt. n-Val . Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (l b/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.085 600.00 1613. 71 1613.71 2537.13 654.43 1.57 2.47 51487.4 654 .45 0.37 0.59 2162.43 446.84 Elev 233 224 231.6 231. 4 233.4 233.8 233.9 241.2 Expan. .3 Channel 0.070 622.00 483.74 483.74 2123.85 52.00 4.39 9.30 43100 .5 56.26 1.30 5.72 548.73 44.40 Right OB 0.085 560.00 2508.60 2508.60 4500.02 833.19 1.79 3.01 91321.4 834.80 0.46 0.82 3026.76 638.37 Warning: The energy loss was greater than 1.0 f t (0.3 m). between the current and previous cross section. This may indicate the need for additional c r oss sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 39222 INPUT Description: Station Elevation Sta Elev 1000 243 1695 231 .l 1795 222 1876 230.9 2144 2413 2588 2682 230.l 226 231 231.9 3040 242.9 Data Sta 1145 1724 1799 1917 2234 2427 2602 2771 Manning's n Values Sta n Val Sta 1784 1000 .085 Bank Sta: Left 1784 Right 1837 CROSS SECTION OUTPUT num= Elev 240.4 231.l 221.7 230.6 230.3 232.2 229.8 233.1 num= n Val .07 41 Sta 1259 1753 1807 1965 2292 2479 2623 2853 3 Sta 1837 Elev 237.2 231.2 222.7 230.l 231.l 232.2 232.2 235.5 n Val .085 Lengths: Left Channel 600 622 Profile #PF 1 Sta 1261 1784 1813 2055 2323 2503 2637 2861 Right 560 Elev 237.2 231 .l 224 229. 4 231.5 232.2 232.3 235 .5 Sta 1517 1792 1837 2105 2396 2554 2666 2950 Coeff Contr. .1 Elev 231.5 222.7 230 .7 229.8 232.l 232 .3 232 239.l Expan. .3 E.G. Elev (ft) 234 .30 El ement Left OB Channel Right OB Vel Head (ft) 0.10 Wt. n-Val . 0.085 0.070 0.085 w.s. Elev (f t) 234.20 Reach Len. (ft) 600.00 622.00 560.00 Crit W.S. (f t) Fl ow Area (sq ft) 951.58 468.68 2992.35 E.G. Slope (ft/ft) 0.002564 Area (sq ft) 951.58 468 .68 2992.35 Q Total (cfs) 9161.00 Fl ow (cfs) 1531. 32 2032.85 5596. 83 Top Width (ft) 1412 .60 Top Width (ft) 388.12 53.00 971..48 Vel Total (ft/s) 2.08 Avg. Vel. (ft/s) 1.61 4.34 1.87 Max Chl Dpt h (ft) 12.50 Hydr. Depth (ft) 2.45 8.84 3 .08 Conv. Total (cfs) 180936 .3 Conv. (cfs) 30244.6 40150.2 110541.4 Length Wtd . (ft) 578.00 Wetted Per. (ft) 388.15 57.81 974 .11 Min Ch El (ft) 221.70 Shear (lb/sq ft) 0.39 1.30 0. 49 Alpha 1. 56 Stream Power (lb/ft s) 0.63 5.63 0.92 Fr ctn Loss (ft) 1. 64 Cum Volume (acre-ft) 2144 .77 541.93 2991.40 C & E Loss (ft) 0.00 Cum SA (acres) 439 .66 43.65 626.77 Warning: The energy loss was greater t han 1.0 ft (0.3 m). between the current and previous cross secti on. This may i ndicate t he need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 38600 INPUT Description : Station Elevat ion Data num= 28 Sta Elev Sta Elev Sta El ev Sta El ev Sta Elev 1000 240 1100 236.5 1200 229.9 1303 229.9 1310 221.1 1315 220 .6 1324 221.7 1357 229.9 1400 229 .9 1500 228.7 1600 227.8 1700 228.6 1800 228.8 1900 230.2 1981 230.8 2000 223.2 2016 230.9 2100 230.7 2157 230.7 2195 229 2211 227.5 2235 230.4 2250 230.5 2300 229 .9 2400 230.7 2500 233.4 2600 237 2700 241.l Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .085 1303 .07 1357 .085 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1303 1357 155 166 92.5 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (f t) 232.66 El ement Left OB Channel Right OB Vel Head (ft ) 0.11 Wt. n-Val. 0.085 0.070 0.085 w.s. Elev (f t) 232 .55 Reach Len. (f t) 155.00 166.00 92 .50 Cr it W.S. (f t) Fl ow Area (sq ft) 325.91 433. 11 3299.19 E.G. Slope (ft/ft) 0.003146 Ar ea (sq ft) 325.91 433 .11 3299.19 Q Total (cf s) 9161.00 Fl ow (cfs) 552.91 1940.44 6667.66 Top Width (ft) 1308. 58 Top Width (ft) 143.13 54.00 1111. 46 Vel Total (ft/s) 2 .26 Avg . Vel. (ft /s) 1 .70 4 .48 2 .02 Max Chl Dp th (ft) 11. 95 Hydr . Depth (ft) 2 .28 8 .02 2.97 Conv. Total (cfs) 163318.7 Conv . (cfs) 9857.0 34593 .3 118868.4 Length Wtd. (ft) 113.12 Wetted Per. (ft) 143.21 59 .34 1115. 02 Min Ch El (f t) 220.60 Shear (lb/sq ft) 0 . 45 1 .43 0.58 Alpha 1.45 Stream Power (lb/ft s) 0.76 6.42 1 .17 Fr ctn Loss (ft) 0.35 Cum Volume (acr e-ft) 2135.97 535.49 2950. 96 C & E Loss (ft) 0.00 Cum SA (acres) 436.00 42.89 613.38 CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 38434 INPUT Description: Station Elevation Data num= 35 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 1000 24 0.5 1074 237 .6 1105 236 .4 1122 235.2 1159 232.7 1210 229.6 1318 229 .4 1320 226 .9 1327 220.5 1333 219.9 1342 221 1354 223.9 1376 229.4 1418 229.4 1515 228.3 1613 1985 2194 2394 227.4 230.4 228 .9 230 .6 Manning's n Values Sta n Val 1000 .085 1711 2004 2210 2414 228.2 223.2 227 .5 231.2 num= Sta n Val 1318 . 07 1808 2019 2233 2492 3 Sta 1376 228.4 230.5 230 233.4 n Val .085 1868 2101 2248 2590 229 .2 230.4 230.3 237 1906 2157 2297 2688 Bank Sta: Left 1318 Right 1376 Lengths: Left Channel 155 166 Right 92.5 Coeff Contr. .1 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G . Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) CROSS SECTION REACH: Fema X-sect INPUT Description: Profile #PF 1 232.31 0 .13 232.18 0.003122 9161.00 1281.21 2.30 12.28 163948.3 115. 84 219.90 1. 55 0.36 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: Lick Creek Main RS: 38268 Station Elevation Data num= 35 Sta Elev 1000 241 1220 229.2 1360 1626 1989 2193 2389 220.4 227.1 230 228 .7 230.6 Manning's n Values Sta n Val 1000 .085 Sta 1078 1333 1372 1721 2007 2209 2408 Elev 237.8 228 .9 223.2 227.8 223.2 227.4 231.l num= Sta n Val 1333 . 07 Sta 1110 1335 1394 1817 2023 2232 2484 3 Sta 1394 Elev 236.2 226 228.9 228 230.2 230.l 233.3 n Val .085 Sta 1128 1343 1435 1875 2103 2246 2580 El ev 234.9 219.8 228.9 228.8 230.1 230.2 236.9 Left OB 0.085 155.00 344.25 344 .25 583.70 150.45 1.70 2.29 10446.l 150.53 0. 45 0.76 2134. 78 435.48 Sta 1166 1351 1531 1912 2157 2294 2675 Bank Sta: Left 1333 Right 1394 Lengths: Left Channel 155 166 Right 92.5 Coeff Contr. .1 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) Profile #PF 1 231.94 0.14 231.80 0 . 003116 9161.00 1257.63 2.34 12 .60 164112. 7 118.75 219.20 1.67 0.37 0.00 Element Wt. n-Val. Reach Len. (ft) Fl ow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.085 155.00 370 .10 370.10 635 .88 158.34 1. 72 2 .34 11391.3 158.42 0.45 0 .78 2133 .50 434.93 229.8 230.5 229.8 241 Expan. . 3 Channel 0.070 166.00 483.31 483.31 2234.50 58.00 4.62 8.33 39989.4 62.81 1.50 6.94 533.74 42 .67 Elev 232.3 219.2 227.9 229 .3 230.2 229.7 241 Expan. .3 Channel 0.070 166.00 532.98 532.98 2547.36 61.00 4.78 8.74 45634.l 65.79 1. 58 7.53 531.81 42.45 Right OB 0.085 92 .50 3163.83 3163.83 6342.79 1072.76 2.00 2.95 113512 .7 1076.05 0.57 1.15 2944.09 611. 06 Right OB 0 .085 92.50 3015.26 3015.26 5977.76 1038.28 1. 98 2.90 107087.3 1041. 28 0.56 1.12 2937.53 608.82 CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 38012 INPUT Description: Station Elevation Data Sta Elev 1000 241.5 1229 228.9 1378 1639 1994 2193 2383 219.7 226.7 229.6 228.6 230.5 Manning's n Values Sta n Val 1000 .085 Sta 1081 1348 1391 1732 2011 2218 2472 Sta 1348 Bank Sta: Left 1348 Right 1413 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) num= Elev 237.9 228.4 222.5 227.4 223.2 227.4 231.l num= n Val .07 35 Sta 1115 1351 1413 1825 2026 2230 2476 3 Sta 1413 Elev 236.l 225.l 228.4 227 .6 229.8 229 .9 233.3 n Val .085 Sta 1133 1360 1453 1882 2104 2244 2569 Lengths: Left Channel Right 92.5 155 166 Profile #PF 1 231.57 0.16 231. 41 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs ) Top Width (ft) Avg . Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Elev 234.6 219.2 228.4 228.4 229.8 230 236.9 Sta 1174 1368 1546 1918 2157 2290 2663 Coeff Contr. .1 Left OB 0.085 155.00 386.87 386.87 668.53 165.09 Vel Total (ft/s ) Max Chl Dpth (ft) Conv. Total (cfs ) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 0.003141 9161.00 1289.66 2 .35 12.81 163457.3 121.70 218.60 1.83 0.38 0.00 Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) 1.73 2.34 11928. 4 165.16 0.46 0.79 2132.16 434.35 CROSS SECTION REACH: Fema X-sect INPUT Description: RIVER: Lick Creek Main RS: 37936 Station Elevation Data num= Elev 238 227.9 221.7 227 223.2 227.3 231 35 Sta Elev 1000 242 1239 228.6 1396 219 1652 226.3 1998 229 .3 2192 2378 228.5 230.5 Manning's n Values Sta n Val 1000 .085 Sta 1085 1362 1409 1743 2015 2206 2396 num= Sta n Val 1362 . 07 Sta 1120 1366 1432 1833 2029 2228 2469 3 Sta 1432 Elev 235.9 224.2 227.9 227.2 229 .4 229 .7 233 .3 n Val .085 Sta 1139 1376 1471 1889 2106 2242 2559 Bank Sta: Left 1362 Right 1432 Lengths: Left Channel 155 166 Right 92. 5 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G . Slope (ft/ft) Profile #PF 1 231.19 0.17 231.02 0.003045 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Elev 234.3 218.6 227.9 227.9 229.5 229.9 236.9 Sta 1181 1386 1561 1924 2157 2287 2650 Coeff Contr . .1 Left OB 0.085 155.00 399.35 399.35 Elev 231.9 218.6 227.4 228.9 230 229.6 240.9 Expan. .3 Channel 0 .070 166 .00 585 .42 585.42 2886.63 65.00 4 .93 9 .01 51505.4 69.38 1. 65 8 .16 529.68 42.21 Elev 231.5 217.9 227 228.5 229.7 229.5 240.9 Expan. .3 Channel 0.070 166.00 651.28 651.28 Right OB 0.085 92.50 2917.80 2917 .80 5605.84 1059.57 1 .92 2.75 100023.4 1062.55 0.54 1.03 2931.23 606.60 Right OB 0.085 92.50 2722.43 2722.43 Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) CROSS SECTION REACH : Fema X-sect INPUT Description: 9161.00 1206.06 2.43 13.12 166022.4 124.50 217.90 1.89 0.37 0.00 Fl ow (cfs) Top Width (ft) Avg. Ve l. (ft/s) Hydr. Depth (ft) Conv. (cfs ) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (l b/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: Lick Creek Main RS: 37770 Station Elevation Data num= Elev 238.l 227.4 35 Sta Elev 1 000 242.5 1249 1414 1665 2002 2191 2372 228.3 218.3 226 228 .8 228.3 230.4 Manning's n Values Sta n Val 1000 .085 Sta 1088 1377 1427 1753 2019 2215 2380 Sta 1377 221 226.6 223.2 227.3 230.9 num= n Val .07 Sta 1125 1381 1450 1842 2033 2226 2461 3 Sta 1450 Elev 235.8 223.3 227.4 226 .8 229 229 .6 233.3 n Val .085 Sta 1145 1393 1488 1895 2107 2240 2549 Elev 234.l 217.9 227.4 227.5 229.2 229.7 236.9 676.84 171.41 1.69 2.33 12266.2 171.47 0.44 0.75 2130.76 433 .76 Sta 1189 1404 1577 1930 2157 2284 2638 Bank Sta: Left 1377 Right 1450 Lengths: Left Channel 155 166 Right 92.5 Coeff Contr. .1 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S . Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) CROSS SECTION REACH: Fema X-sect INPUT Description: Profile #PF 1 230.82 0.19 230.63 0.002969 9161.00 1176. 63 2.47 13. 43 168118 . 2 127.34 217.20 1.98 0.37 0.00 Element Wt . n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs ) Top Width (ft) Avg . Vel. (ft/s ) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: Lick Creek Main RS: 37604 Station Elevation Data num= 35 Sta El ev 1000 243 1259 1432 1678 2006 2190 2387 227.9 217.7 225.6 228 .4 228 .2 230.4 Manning's n Values Sta n Val 1000 .085 Sta 1091 1392 1445 1764 2022 2204 2394 Elev 238.3 226 .9 220.3 226.2 223.2 227.2 230.9 num= Sta n Val 1392 . 07 Sta 1129 1396 1469 1850 2036 2225 2453 3 Sta 1469 Elev 235.6 222.4 226.9 226.4 228.7 229.4 233.2 n Val .085 Sta 1150 1409 1506 1902 2108 2238 2539 Elev 233.8 217.3 227 227.l 228.9 229.5 236.8 Left OB 0.085 155.00 414.09 414 .09 692.55 177 .94 1.67 2.33 12709.3 178.00 0 .43 0.72 2129.31 433. 13 Sta 1196 1422 1592 1936 2158 2281 2625 3249.15 70.00 4.99 9.30 58883.5 74.09 1.67 8.34 527.32 41.95 Elev 231.l 217 .2 226.6 228.l 229.5 229.4 240.8 Expan . .3 Channel 0 .070 166.00 704.82 704.82 3563.78 73.00 5.06 9.66 65400.7 77.12 1. 69 8.57 524.74 41.68 Elev 230.7 216.5 226.2 227.6 229.2 229.3 240.8 5235.01 964. 65 1.92 2.82 94872 .7 967. 26 0.54 1.03 2925.25 604.45 Right OB 0.085 92.50 2594.50 2594.50 4904.67 925.69 1. 89 2.80 90008.2 928.06 0.52 0.98 2919.60 602.44 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr . Expan. 1392 1469 155 166 92 .5 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 230.44 Element Left OB Channel Right OB Vel Head (ft) 0.20 Wt. n-Val. 0.085 0.070 0.085 w.s. Elev (ft) 230.24 Reach Len. (ft) 155.00 166.00 92.50 Crit W.S. (ft) Flow Area (sq ft) 439 .99 768.01 2468.70 E.G. Slope (ft/ft) 0.002876 Area (sq ft) 439.99 768.01 2468.70 Q Total (cfs) 9161.00 Flow (cfs) 732.91 3909 .41 4518.68 Top Width (ft) 1165. 66 Top Width (ft) 185.73 77.00 902.93 Vel Total (ft/s ) 2 .49 Avg. Vel. (ft/s) 1. 67 5.09 1. 83 Max Chl Dpth (ft) 13.74 Hydr . Depth (ft) 2.37 9.97 2.73 Conv. Total (cfs) 170814.8 Conv. (cfs) 13665.8 72894.4 84254.6 Length Wtd. (ft) 129.89 Wetted Per. (ft) 185.79 81.23 904.99 Min Ch El (ft) 216.50 Shear (lb/sq ft) 0.43 1. 70 0.49 Alpha 2.08 Stream Power (lb/ft s) 0. 71 8.64 0.90 Frctn Loss (ft) 0.36 Cum Volume (acre-ft) 2127.79 521.93 2914.22 C & E Loss (ft) 0.00 Cum SA (acres) 432.49 41.39 600.50 CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 37438 INPUT Description: Station Elevation Data num: 35 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 243.5 1095 238.4 1134 235.5 1156 233.5 1203 230.3 1259 227.6 1407 226 .4 1412 221.5 1426 216.7 1439 215.8 1450 217 1463 219.5 1488 226.4 1524 226.5 1607 225.8 1691 225.2 1775 225.8 1859 226 1909 226.6 1942 227.2 2010 228 2026 223.2 2043 228.3 2110 228.7 2158 229 2189 228 .l 2213 227.2 2223 229.2 2236 229.4 2277 229.3 2361 230.3 2378 230.8 2445 233.2 2529 236.8 2613 240.7 Manning's n Values num: 3 Sta n Val Sta n Val Sta n Val 1000 .085 1407 .07 1488 .085 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1407 1488 155 166 92.5 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 230.09 El ement Left OB Channel Right OB Vel Head (ft) 0.20 Wt. n-Val. 0.085 0.070 0.085 w.s. Elev (ft) 229.89 Reach Len. (ft) 155.00 166 .00 92.50 Crit W.S. (ft) Flow Area (sq ft) 482.02 831.26 2379.17 E.G. Slope (ft/ft) 0. 002611 Area (sq ft) 482.02 831.26 2379.17 Q Total (cfs) 9161.00 Flow (cfs) 785.75 4121.35 4253.90 Top Width (ft) 1115. 01 Top Width (ft) 195.49 81. 00 838 .52 Vel Total (ft/s) 2.48 Avg. Vel. (ft/s) 1.63 4.96 1.79 Max Chl Dpth (ft) 14.09 Hydr. Depth (ft) 2.47 10 .26 2.84 Conv. Total (cfs) 179269 .9 Conv. (cfs) 15376.2 80649 .9 83243.9 Length Wtd. (ft) 132.54 Wetted Per. (ft) 195.55 85.07 840.23 Min Ch El (ft) 215 .80 Shear (lb/sq ft) 0.40 1.59 0.46 Alpha 2.07 Stream Power (lb/ft s) 0.66 7.90 0.83 Frctn Loss (ft) 0.34 Cum Volume (acre-ft ) 2126.15 518.88 2909.08 C & E Loss (ft) 0.00 Cum SA (acres) 431 .81 41.09 598.65 CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 37272 INPUT Description: Station Elevation Data num: 35 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 1278 1468 1704 2014 2189 2356 244 227.3 216.3 224 .9 227.7 228 230.3 Manning's n Values Sta n Val 1000 .085 1098 1422 1482 1786 2030 2202 2372 238.5 225.9 218 .8 225.4 228.2 227.2 230.7 num= Sta n Val 1422 . 07 1139 1427 1506 1867 2043 2221 2437 3 Sta 1506 235.3 220 .6 225.9 225.6 227 .9 229 233.2 n Val .085 1162 1442 1541 1916 2111 2233 2519 233.3 216 226 226.2 228 .4 229.2 236.8 1211 1457 1623 1948 2158 2274 2600 Bank Sta: Left 1422 Right 1506 Lengths: Left Channel 155 166 Right 92.5 Coeff Contr. .1 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) CROSS SECTION REACH: Fema X-sect INPUT Description: Profile #PF 1 229.74 0.22 229.52 0.002553 9161.00 1077.55 2.55 14.32 181305.2 134.57 215.20 2.16 0.32 0.01 Element Wt. n-Val . Reach Len . (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: Lick Creek Main RS: 37106 Station Elevation Data num= 35 Sta Elev 1000 244.5 1288 1485 1717 2019 2188 2350 227 215.7 224.5 227.3 227.8 230.2 Manning's n Values Sta n Val 1000 .085 Sta 1102 1437 1500 1796 2034 2201 2366 Elev 238.6 225.4 218.l 225 223.2 227.l 230.7 num= Sta n Val 1437 . 07 Sta 1144 1442 1525 1875 2046 2220 2429 3 Sta 1525 Elev 235.2 219.8 225.4 225.4 227.6 228.9 233.2 n Val .085 Sta 1167 1459 1559 1923 2113 2231 2508 Elev 233 215.4 225 .5 225 .8 228 .l 229 236.7 Left OB 0.085 155.00 484.95 484.95 769.59 201.33 1. 59 2. 41 15231.0 201 .38 0.38 0.61 2124.43 431.10 Sta 1218 1475 1638 1954 2158 2271 2588 Bank Sta: Left 1437 Right 1525 Lengths: Left Channel 155 166 Right 92.5 Coeff Contr. .1 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Profile #PF 1 229.42 0.20 229.22 0.002190 9161. 00 1053.83 2.46 14.72 195739.9 135. 50 214 .50 2.12 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Left OB 0.085 155.00 519.08 519.08 773 .41 211.1 7 1.49 2.46 16525.2 211. 22 0.34 0.50 229.9 215.2 225.3 226.8 228.7 229.2 240.7 Expan. .3 Channel 0.070 166.00 899.99 899.99 4537.78 84.00 5.04 10. 71 89807 .l 88.30 1.62 8.19 515.58 40.78 Elev 229.5 214.5 224.9 226.3 228.5 229 .1 240.6 Expan. . 3 Channel 0.070 166.00 971 . 75 971. 75 4634.21 88.00 4.77 11. 04 99017.5 92.40 1.44 6.86 Right OB 0.085 92.50 2205.10 2205.10 3853.63 792.21 1.75 2.78 76267.2 792.37 0.44 0.78 2904.21 596.92 Right OB 0.085 92.50 2230.42 2230.42 3753.38 754.65 1.68 2. 96 80197.1 756.12 0. 40 0.68 Frctn Loss (ft) c & E Loss (ft) CROSS SECTION REACH: Fema X-sect INPUT Description: 0.27 0.01 Cum Volume (acre-ft) Cum SA (acres) RIVER: Lick Creek Main RS: 36940 Station Elevation Data num= 35 Sta Elev 1000 245 1298 226.6 1503 215 1730 224.1 2023 226.9 2187 2345 227.7 230.2 Manning's n Values Sta n Val 1000 .085 Sta 1105 1452 1518 1807 2037 2199 2360 Elev 238.8 224.9 217.3 224.6 223.2 227.l 230.6 num= Sta n Val 1452 . 07 Sta 1149 1457 1544 1884 2050 2218 2421 3 Sta 1544 Elev 235 218.9 224.9 224.8 227.2 228.7 233.l n Val .085 Sta 1173 1475 1577 1930 2114 2229 2498 Bank Sta: Left 1452 Right 1544 Lengths: Left Channel Right 92.5 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) 155 166 Profile #PF 1 229.14 0.18 228.97 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs ) Wetted Per. (ft) Elev 232.7 214.8 225 225.3 227.8 228.9 236.7 2122.65 430.37 Sta 1226 1493 1653 1961 2158 2268 2575 Coeff Contr. .1 Left OB 0.085 155.00 575.68 575.68 809.79 222.12 Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 0.001819 9161 .00 1024 .52 2 .36 15 .17 214783.7 136.47 213 .80 2.07 0 .23 0.00 Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) 1. 41 2.59 18985.8 222.17 0.29 0.41 2120.70 429.60 CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 36774 INPUT Description: Station Elevation Sta Elev 1000 245.3 1308 226.3 1521 1743 2027 2186 2339 214.3 223.8 226.5 227.6 230.1 Data Sta 1109 1466 1536 1818 2041 2198 2354 Manning 's n Values Sta n Val Sta 1466 1000 .085 Bank Sta: Left 1466 Right 1562 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) num= Elev 238.9 224 .5 216 .6 224.2 223.2 227 230.6 num= n Val .07 35 Sta 1154 1473 1562 1892 2053 2216 2414 3 Sta 1562 Elev 234.9 218 224.5 224.4 226.8 228.5 233.l n Val .085 Lengths: Left Channel 155 166 Profile #PF 1 228.91 0.16 Element Wt. n-Val. Sta 1179 1492 1594 1937 2116 2227 2488 Right 92.5 El ev 232.4 214.l 224.5 224.9 227.5 228.7 236.7 Sta 1233 1510 1669 1967 2158 2265 2563 Coeff Contr. .1 Left OB 0.085 512.02 40.45 Elev 229.1 213.8 224.5 225.9 228.2 229 240.6 Expan. . 3 Channel 0.070 166.00 1059.74 1059 .74 4736.08 92.00 4.47 11. 52 111039. 4 96.63 1.25 5.57 508.15 40 .11 Elev 228.6 213 .l 224.1 225.5 228 228.9 240.5 Expan. . 3 Channel 0.070 2899.50 595.27 Right OB 0.085 92.50 2250.39 2250.39 3615.14 710.40 1.61 3.17 84758.5 711. 60 0.36 0.58 2894.74 593.72 Right OB 0 .085 W.S. Elev (ft) Crit W.S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft ) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) CROSS SECTION REACH: Fema X-sect INPUT Description: 228.75 0.001542 9161.00 1005.29 2.27 15.65 233295.4 136.97 213.10 2.04 0.19 0 .01 Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (f t/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft ) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: Lick Creek Main RS: 36608 Station El evation Data num= Elev 239 224 215.9 223 223.2 227 230 .5 35 Sta Elev 1000 246 1318 226 1539 213.7 1756 2031 2186 2333 223 .4 226.l 227.4 230.l Manning's n Values Sta n Val 1000 .085 Sta 1112 1481 1554 1828 2045 2197 2348 num= Sta n Val 1481 . 07 Sta 1159 1488 1581 1900 2056 2214 2406 3 Sta 1581 Elev 234.7 217.1 224 224 226.5 228.4 233.l n Val .085 Sta 1184 1509 1612 1944 2117 2225 2478 El ev 232.2 213.5 224 224.5 227.2 228.6 236.7 155.00 626.57 626.57 826.65 235 .11 1. 32 2.67 21051.5 235.16 0.26 0.34 2118. 56 428.78 Sta 1241 1528 1684 1973 2158 2261 2550 Bank Sta: Left 1481 Right 1581 Lengths: Left Channel 155 166 Right 92.5 Coeff Contr. .1 CROSS SECTION OUTPUT E .G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E .G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Tot al (cfs) Length Wtd. (ft) Min Ch El (ft) Al pha Frctn Loss (ft) c & E Loss (ft) CROSS SECTION REACH: Fema X-sect INPUT Description: Profile #PF 1 228. 72 0.14 228.58 0 .001231 9161.00 988.15 2 .12 16.18 261066.7 137 .82 212 .40 1.97 0.16 0 .00 Element Wt. n-Val. Reach Len . (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv . (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RI VER : Lick Creek Main RS : 36442 Station Elevation Data num= 35 Sta Elev 1000 246.5 1327 225. 7 1557 213 1769 223 2035 225.7 2185 2328 227.3 230 Sta 1116 1496 1573 1839 2049 2196 2342 Elev 239 .l 223.5 215 .l 223.5 223.2 226.9 230.4 Sta 1164 1503 1599 1909 2060 2213 2398 Elev 234. 6 216.2 223.5 223.7 226.l 228.2 233 Sta 1190 1525 1629 1951 2118 2223 2468 Elev 231.9 212.9 223 .5 224 226.9 228 .4 236.6 Left OB 0.085 155.00 697.96 697.96 859.38 245.38 1.23 2.84 24490.3 245.44 0 .22 0.27 2116. 20 427.93 Sta 1248 1546 1699 1979 2158 2258 2538 166.00 1144 .59 1144.59 4833.05 96 .00 4.22 11.92 123079.2 100.39 1.10 4.63 503 .95 39.75 Elev 228 .2 212.4 223.7 225.l 227.7 228.8 240.4 Expan. . 3 Channel 0.070 166.00 1242.37 1242.37 4817.66 100.00 3.88 12.42 137292 .0 104.59 0.91 3.54 499.40 39.37 Elev 227.8 211. 8 223.2 224.6 227.5 228 .7 240.4 92.50 2271. 67 2271. 67 3501.30 674.18 1.54 3.37 89164.7 675.21 0.32 0.50 2889.94 592.25 Right OB 0.085 92.50 2377.08 2377.08 3483.95 642.77 1.47 3.70 99284.4 643.66 0.28 0 .42 2885.01 590 .85 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .085 1496 .07 1599 .085 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. 14 96 1599 155 166 92.5 .1 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 228.56 Element Left OB Vel Head (ft) 0 .13 Wt. n-Val. 0.085 w.s. Elev (ft) 228 .43 Reach Len. (ft) 155 .00 Crit W.S. (ft) Flow Area (sq ft) 782.73 E.G. Slope (ft/ft) 0.001040 Area (sq ft) 782.73 Q Total (cfs) 9161. 00 Flow (cfs) 927 .05 Top Width (ft) 987.38 Top Width (ft) 256.91 Vel Total (ft/s) 2.03 Avg. Vel. (ft/s) 1.18 Max Chl Dpth (ft) 16.63 Hydr. Depth (ft) 3.05 Conv. Total (cfs) 284129.0 Conv . (cfs) 28752.4 Length Wtd . (ft) 139.08 Wetted Per. (ft) 256 .97 Min Ch El (ft) 211. BO Shear (lb/sq ft) 0 .20 Alpha 1. 98 Stream Power (lb/ft s) 0 .23 Frctn Loss (ft) 0 .13 Cum Volume (acre-ft) 2113. 57 C & E Loss (ft) 0.00 Cum SA (acres) 427 .04 CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect INPUT Description: Station Elevat ion Data Sta Elev Sta 1000 247 1119 1337 225.3 1511 1575 212.3 1591 1782 222.7 1850 2039 225.3 2052 2184 227.2 2195 2322 230 2336 Manning's n Values Sta n Val Sta 1000 .085 1511 Bank Sta: Left 1511 Right 1618 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dp th (ft) Conv. Total (cfs) Length Wt d . (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) RS : 36276 num= 35 El ev Sta Elev Sta El ev Sta 239.3 1169 234.4 1196 231.6 1255 223 1518 215.4 1542 212.3 1564 214 .4 1618 223 1647 223 1715 223 .1 1917 223.3 1958 223 .6 1985 223.2 2063 225.7 2120 226 .6 2158 226.9 2211 228 2221 228.2 2255 230.4 2390 233 2457 236 .6 2525 num= 3 n Val Sta n Val .07 1618 .085 Lengths: Left Channel 155 166 Ri ght 92 .5 Coeff Contr. .1 Profile #PF 1 228.42 0 .11 228.31 0.000855 9161.00 988 . 13 1. 91 17.21 313302.7 139 .92 211. 10 1.96 0 .11 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (f t) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.085 155.00 890.37 890.37 1011.17 268.78 1.14 3.31 34581.5 268.86 0.18 0.20 2110.59 426.10 CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 36110 INPUT Expan. .3 Channel 0.070 166.00 1346. 86 1346.86 4959.95 103 .00 3.68 13.08 153833.3 107.91 0.81 2.98 494. 47 38.99 Elev 227.4 211.1 222.B 224.2 227.2 228.6 240.3 Expan. .3 Channel 0 .070 166.00 1457.77 1457.77 5003.53 107.00 3.43 13.62 171118. 7 112.10 0.69 2.38 489.12 38.59 Right OB 0 .085 92.50 2386 .02 2386.02 3274.00 627.47 1.37 3.80 101543.4 628.16 0.25 0.34 2879.95 589 .50 Right OB 0.085 92.50 2446.22 2446.22 3146.31 612.35 1.29 3.99 107602.5 612.87 0 .21 0 .27 2874 .82 588.19 Description: Station Elevation Sta Elev 1000 247.5 1347 225 1593 211 .6 1795 222.3 2044 2183 2317 224 .9 227 229.9 Manning's n Values Sta n Val 1000 .085 Data Sta 1123 1526 1609 1860 2056 2194 2330 num= Elev 239.4 222.5 213 . 7 222.7 223.2 226 .9 230 .3 num= Sta n Val 1526 . 07 35 Sta 1174 1534 1637 1926 2066 2209 2382 3 Sta 1637 Elev 234.3 214.4 222.5 222.9 225.3 227.9 233 n Val .085 Sta 1202 1558 1665 1965 212 1 2219 2447 Bank Sta: Left 1526 Right 1637 Lengths: Left Channel Right 92.5 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) 155 166 Profile #PF 1 228.31 0.10 228.21 Element Wt. n-Val. Reach Len . (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Elev 231.4 211. 6 222.5 223.2 226 .3 228.1 236.6 Sta 1263 1581 1730 1991 2158 2252 2513 Coeff Contr. .1 Left OB 0.085 155.00 994.60 994.60 Vel Total (ft/s ) Max Chl Dpth (ft) Conv . Total (cfs) Length Wtd . (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) 0.000700 9161.00 982.01 1.80 17.81 346266.9 140.58 210.40 1. 93 0.09 0.00 Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) 1071. 20 279.80 1. 08 3.55 40489.2 279 .88 0 .16 0.17 2107.24 425.12 CROSS SECTION REACH : Fema X-sect INPUT Description: RIVER: Lick Creek Main RS: 35944 Station Elevation Data num= Elev 239.5 35 Sta Elev 1000 248 1357 224.7 1611 211 1808 2048 2182 2311 221.9 224 .5 226.9 229.9 Manning's n Values Sta n Val 1000 .085 Sta 1126 1541 1627 1871 2060 2192 2324 222 212.9 222.3 223.2 226.8 230.2 num= Sta n Val 1541 .07 Sta 1178 1549 1655 1934 2070 2208 2374 3 Sta 1655 Elev 234.l 213. 5 222 222.5 225 227.7 233 n Val .085 Sta 1207 1575 1682 1972 2123 2217 2437 Bank Sta: Left 1541 Right 1655 Lengths: Left Channel Right 92 .5 CROSS SECTION OUTPUT E .G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s ) Max Chl Dpth (ft) Conv. Total (cfs) 155 166 Profile #PF 1 228.22 0.09 228. 13 0.000577 9161.00 982 .75 1.70 18.43 381355. 9 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Elev 231.l 211 222 222.7 226 227.9 236 .5 Sta 1270 1599 1745 1997 2159 2248 2500 Coeff Contr. .1 Left OB 0.085 155.00 1111. 94 1111. 94 1137.32 292.43 1.02 3.80 47344.5 Elev 227 210.4 222.4 223.8 227 228.5 240.3 Expan. .3 Channel 0 .070 166 .00 1577.70 1577.70 5044 .85 111. 00 3 .20 14.21 190685 .l 116 . 13 0.59 1. 90 483.34 38.17 Elev 226.6 209.7 222 223.3 226.8 228.4 240 .2 Expan. . 3 Channel 0.070 166.00 1694.03 1694.03 5061.14 114. 00 2.99 14.86 210686.2 Right OB 0 .085 92.50 2511. 32 2511. 32 3044.95 591.21 1.21 4 .25 115092.7 591.62 0.19 0.22 2869.55 586.91 Right OB 0.085 92 .50 2590.85 2590 .85 2962.54 576.32 1.14 4.50 123325.2 Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) CROSS SECTION REACH: Fema X-sect INPUT Description: Station Elevation Sta Elev 1000 248.5 1367 224.4 1629 210.3 1821 221 .6 2052 2182 2306 224.l 226.8 229.8 Manning's n Values Sta n Val 1000 .085 141. 28 209.70 1.90 0.07 0.00 Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: Lick Creek Main RS: 35778 Data Sta 1130 1555 1645 1882 2064 2191 2318 num= El ev 239.6 221. 5 212.2 221.9 223.2 226.8 230.2 num= Sta n Val 1555 . 07 35 Sta 1183 1564 1674 1942 2073 2206 2366 3 Sta 1674 Elev 234 212.7 221.5 222 .l 224.6 227.5 232.9 n Val .085 Sta 1213 1591 1700 1979 2124 2215 2427 El ev 230 .8 210 .4 221 .6 222.3 225.7 227 .7 236.5 292.53 0.14 0.14 2103.49 424.11 Sta 1278 1617 1761 2003 2159 2245 2488 Bank Sta: Left 1555 Right 1674 Lengths: Left Channel 155 166 Right 92.5 Coeff Contr. .1 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (f t) Alpha Frctn Loss (ft) c & E Loss (ft) 228.14 0.07 228.06 0. 000475 9161. 00 981. 57 1.60 19.06 420419.0 142.10 209.00 1. 88 0.06 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq f t) Flow (cfs ) Top Width (ft) Avg. Vel. (ft /s) Hydr . Depth (ft) Conv. (cfs) Wetted Per. (ft ) Shear (lb/sq ft ) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 35612 INPUT Description: Station Elevation Data num= Elev 239.8 Sta Elev Sta 1000 249 1133 1376 1647 1834 2056 2181 2300 224 209.6 221 .2 223.7 226.6 229 .8 Manning's n Values Sta n Val 1000 .085 1570 1664 1892 2067 2190 2312 221 211. 5 221. 5 223.2 226.7 230.l num= Sta n Val 1570 . 07 35 Sta 1188 1579 1693 1951 2077 2204 2358 3 Sta 1693 Elev 233 .8 211. 8 221 221.7 224.2 227.4 232.9 n Val .085 Sta 1219 1608 1718 1986 2125 2213 2417 Elev 230.5 209.7 221.l 221.9 225 .4 227.6 236.5 Left OB 0.085 155.00 1232 .11 1232 .11 1194. 53 303.35 0.97 4.06 54819 .5 303.45 0.12 0.12 2099.32 423.05 Sta 1285 1635 1776 2009 2159 2242 2475 Bank Sta: Left 1570 Right 1693 Lengths: Left Channel 155 166 Right 92.5 Coeff Contr. .1 CROSS SECTION OUTPUT Profile #PF 1 119. 45 0.51 1. 53 477 .10 37.74 Elev 226.2 209 221.5 222.9 226.5 228.3 240.2 Expan. .3 Channel 0.070 166.00 1837.27 1837.27 5116. 72 119. 00 2.78 15 .44 234818.0 124 .36 0 .44 1 .22 470.37 37 .30 Elev 225.8 208 .4 221.l 222 .5 226.3 228 .2 240.l Expan. . 3 576.62 0.16 0.19 2864.14 585.67 Right OB 0.085 92 .50 2651.44 2651.44 2849.75 559.22 1.07 4.74 130781.6 559.43 0.14 0.15 2858.57 584.46 E.G. Elev (ft) 228 .08 Element Left OB Channel Right OB Vel Head (ft) 0.07 Wt. n-Val. 0.085 0.070 0.085 w.s. Elev (ft) 228.01 Reach Len. (ft) 155.00 166.00 92.50 Crit W.S. (ft) Flow Area (sq ft ) 1386.30 1982.95 2708 .42 E.G. Slope (ft/ft) 0.000389 Area (sq ft) 1386.30 1982.95 2708.42 Q Total (cfs) 9161.00 Flow (cfs) 1280.86 5143.05 2737.09 Top Width (ft) 978.86 Top Width (ft) 316.04 123.00 539.83 Vel Total (ft/s) 1.51 Avg. Vel. (ft/s) 0.92 2.59 1 .01 Max Chl Dpth (ft) 19.61 Hydr. Depth (ft) 4.39 16.12 5 .02 Conv. Total (cfs) 464350.3 Conv. (cfs) 64924 .0 260689 .6 138736.7 Length Wtd. (ft) 142.77 Wetted Per. (ft) 316.16 128.66 539.97 Min Ch El (ft) 208.40 Shear (lb/sq ft) 0 .11 0.37 0.12 Alpha 1. 85 Stream Power (lb/ft s) 0.10 0.97 0.12 Frctn Loss (ft) 0.05 Cum Volume (acre-ft) 2094.66 463.10 2852.88 C & E Loss (ft) 0.00 Cum SA (acres) 421. 94 36.84 583.30 CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 35446 INPUT Description: Station Elevation Data num= 35 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 249. 5 1137 239.9 1193 233.7 1224 230.3 1293 225.4 1386 223.7 1585 220.5 1595 210.9 1624 209.l 1652 207.7 1665 209 1682 210.7 1711 220.5 1735 220.6 1791 220.7 1847 220.8 1903 221.1 1959 221.3 1993 221.4 2015 222.l 2060 223.3 2071 223.2 2080 223.9 2127 225.l 2159 226 2180 226.5 2189 226.7 2202 227.2 2211 227.4 2239 228.2 2295 229.7 2306 230.1 2351 232.9 2407 236.5 2463 240.l Manning's n Va l ues num= 3 Sta n Val Sta n Val Sta n Val 1000 .085 1585 .07 1711 .085 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1585 1711 155 166 92.5 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 228.02 Element Left OB Channel Right OB Vel Head (ft) 0.06 Wt. n-Val. 0.085 0.070 0.085 w.s . Elev (ft) 227.96 Reach Len. (ft) 155.00 166.00 92.50 Crit W.S. (ft) Flow Area (sq ft) 1530.93 2112. 94 2766.49 E.G. Slope (ft/ft) 0.000326 Area (sq ft) 1530.93 2112 . 94 2766.49 Q Total (cfs) 9161.00 Flow (cfs) 1348.82 5150 .78 2661.40 Top Width (ft) 973.88 Top Width (ft) 328 . 11 126 .00 519.76 Vel Total (ft/s ) 1. 43 Avg. Vel. (ft/s) 0.88 2.44 0.96 Max Chl Dpth (ft) 20.26 Hydr. Depth (ft) 4.67 16.77 5 .32 Conv. Total (cfs) 507410.3 Conv. (cfs) 74708.4 285292.0 147409.9 Length Wtd. (ft) 143.42 Wetted Per. (ft) 328.25 131. 71 519.87 Min Ch El (ft) 207.70 Shear (lb/sq ft) 0.09 0.33 0.11 Alpha 1.82 Stream Power (lb/ft s) 0.08 0.80 0.10 Frctn Loss (ft) 0.04 Cum Volume (acre-ft) 2089.47 455.29 2847 .07 C & E Loss (ft) 0.00 Cum SA (acres) 420.80 36.36 582.17 CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 35280 INPUT Description: Station Elevation Data num= 12 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 250 1140 240 1230 235 1300 225 1600 220 1610 210 1670 207 1700 210 1730 220 2000 221 2300 230 2450 240 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .085 1600 .07 1730 .085 Bank Sta : Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1600 1730 700 1080 1050 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G . Elev (ft) 227.98 Element Left OB Channel Right OB Vel Head (ft) 0.05 Wt. n-Val. 0.085 0 .070 0.085 w.s. Elev (ft) 227.93 Reach Len. (ft) 700.00 1080.00 1050.00 Crit W.S. (ft) Flow Area (sq ft) 1657.95 2265.45 2804.80 E.G. Slope (ft/ft) 0.000273 Area (sq ft) 1657.95 2265.45 2804.80 Q Total (cfs) 9161.00 Flow (cfs) 1430.46 5178.41 2552 .13 Top Width (ft) 951.37 Top Width (ft) 320.49 130. 00 500.89 Vel Total (ft/s) 1. 36 Avg. Vel. (ft/s) 0.86 2 .29 0.91 Max Chl Dpth (ft) 20.93 Hydr. Depth (ft) 5.17 17.43 5.60 Conv. Total (cfs) 554922.1 Conv. (cfs) 86649.0 313679.3 154593.8 Length Wtd. (ft) 978.53 Wetted Per. (ft) 320.74 135.99 500.99 Min Ch El (ft) 207.00 Shear (lb/sq ft) 0.09 0.28 0 .10 Alpha 1.78 Stream Power (lb/ft s) 0.08 0.65 0.09 Frctn Loss (ft) 0.54 Cum Volume (acre-ft) 2083.80 446 .95 2841 .15 C & E Loss (ft) 0.01 Cum SA (acres) 419.64 35 .88 581.09 Warning: The conveyance r atio (upstream conveyance divided by downstream conveyance) is less than 0.7 or great er than 1.4. This may indi cate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 34200 INPUT Description: Station Elevation Data num= 30 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 250.2 1100 246.8 1200 238.1 1300 231.7 1400 223.3 1415 222.1 1437 215.2 1454 222.5 1500 222 1600 222.3 1622 211.4 1626 210.9 1629 211.7 1645 220.8 1700 221.6 1749 21 9.6 1757 214 1764 219.6 1 800 220.5 1832 219.6 1875 222.1 1900 226.9 1944 237.1 2000 238.9 2100 241.1 2200 242.3 2300 241.5 2400 239.9 2500 239.8 2850 240 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1600 .07 1645 .085 Bank Sta: Left Right Lengths: Left Channel Right Coe f f Contr. Expan. 1600 1645 570 614 520 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 227.43 Element Left OB Channel Right OB Vel Head (ft) 0 .13 Wt. n-Val. 0 .075 0.070 0.085 w.s. Elev (f t) 227.30 Reach Len. (ft) 570 .00 614.00 520.00 Crit W.S. (ft) Flow Area (sq ft ) 1244. 72 519 .16 1661.20 E.G. Slope (ft/ft) 0.001674 Area (sq ft) 1244.72 519 .16 1661.20 Q Total (cfs) 9161.00 Flow (cfs) 2938.77 2143.02 4079.21 Top Width (ft) 549.29 Top Width (ft) 247 .58 45.00 256 . 71 Vel Total (ft/s) 2.67 Avg. Vel. (ft/s) 2.36 4.13 2.46 Max Chl Dpth (ft) 16.40 Hydr. Depth (ft) 5.03 11. 54 6.47 Conv. Total (cfs) 223934.4 Conv. (cfs) 71836. 3 52384.6 99713. 5 Length Wtd. (ft) 557.97 Wetted Per . (ft) 250.36 50.09 261.09 Min Ch El (ft) 210.90 Shear (lb/sq ft) 0.52 1. 08 0.66 Alpha 1.18 Stream Power (lb/ft s) 1. 23 4.47 1.63 Fr ctn Loss (ft) 1. 00 Cum Volume (acre-ft) 2060.47 412.43 2787.33 C & E Loss (ft) 0.00 Cum SA (acres) 415 .08 33.71 571. 96 Warning : The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 33586 INPUT Description: Station Elevation Data Sta Elev 1000 245.6 1373 222.2 1467 221 .l 1590 1711 1793 1960 2258 2475 210.7 219 219 234.3 236 .7 235.8 Manning's n Values Sta n Val 1000 .075 Sta 1093 1387 1560 1594 1719 1836 2059 2269 2526 Sta 1560 Bank Sta: Left 1560 Right 1608 CROSS SECTION OUTPUT E .G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) num= Elev 242.6 221. 3 221 .3 212.5 214.5 221 236.4 236.6 235.9 num= n Val .07 43 Sta 1140 1408 1571 1608 1726 1857 2063 2357 2804 3 Sta 1608 Elev 239 215.7 219 .l 219.8 219 224.2 236.4 235 .6 238 n Val .085 Sta 1187 1420 1583 1651 1754 1861 2159 2372 Elev 235 220.2 210.4 220 .4 219.6 224 .8 237.l 235.6 Sta 1280 1424 1587 1662 1761 1904 2166 2456 Lengths: Left Channel Right 520 Coeff Contr. .1 570 614 Profile #PF 1 226.42 0.14 226.28 0.001940 9161.00 551.66 2.79 16.28 207991.6 559.98 210.00 1.18 1.12 0.00 Element Wt. n-Val. Reach Len. (ft ) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel . (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.075 570.00 1146. 62 1146.62 2801.28 242.80 2.44 4 .72 63600.2 244.77 0 .57 1.39 2044.83 411. 87 Elev 229 221. 6 210 220.6 219.7 232.9 237.1 235.7 Expan. . 3 Channel 0.070 614 .00 517.91 517.91 2204 .50 48.00 4 .26 10 .79 50051.0 53.32 1.18 5.01 405.12 33.05 Right OB 0.085 520.00 1613. 74 1613. 74 4155.23 260.86 2.57 6.19 94340.4 263.88 0.74 1. 91 2767.78 568.87 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 32972 INPUT Description: Station Elevation Sta Elev 1000 241 1347 221.2 1433 1551 1673 1755 1920 2216 2431 220.2 209.6 218.4 218.4 229.8 231.9 231.7 Data Sta 1007 1360 1520 1556 1681 1797 2019 2225 2482 Manning's n Values Sta n Val Sta 1520 1000 .075 Bank Sta: Left 1520 Right 1570 CROSS SECTION OUTPUT num= Elev 238.4 220.4 220.2 211 .1 215 219.8 231.7 231.9 231.9 num= n Val .07 43 Sta 1130 1379 1531 1570 1688 1818 2022 2314 2758 3 Sta 1570 Elev 235.5 216.3 213.8 218.8 218.4 222.2 231.7 231.5 236 n Val .085 Lengths: Left Channel 570 614 Profile #PF 1 Sta 1173 1390 1543 1613 1715 1822 2117 2329 Right 520 Elev 232 219.6 209.4 219.5 218.8 222 .7 232 231.3 Sta 1260 1393 1548 1624 1723 1865 2124 2413 Coeff Contr . .1 Elev 226.4 220.6 209 219.6 218.9 228.7 231.9 231.6 Expan. . 3 E.G. Elev (ft) Vel Head (ft) W.S . Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s ) Max Chl Dpth (ft ) Conv. Total (cfs ) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) 225.30 0.17 225 .13 0 .002048 9161.00 558.24 2.89 16 .13 202453.9 563.65 209.00 1. 32 1. 24 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s ) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft ) Stream Power (lb/ft s ) Cum Volume (acre-ft) Cum SA (acres) Left OB 0 .075 570.00 1027.22 1027 .22 2427.43 238.80 2.36 4.30 53645.l 240.03 0 .55 1.29 2030 .61 408.72 Channel 0.070 614.00 595.50 595.50 2806.94 50.00 4.71 11.91 62032.2 54 .78 1. 39 6 .55 397.27 32.36 Right OB 0.085 520.00 1551 .94 1551.94 3926.63 269 .44 2 .53 5 .76 86776.6 271.30 0.73 1 .85 2748.88 565.70 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and prev ious cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 32358 INPUT Description: Station Elevation Data Sta Elev 1000 236 .5 1320 1400 1512 1635 1726 1880 2174 2387 220.l 219 .3 208 .6 217.8 217.7 225.2 227.l 227.7 Manning's n Values Sta n Val 1000 .075 Sta 1080 1332 1480 1517 1642 1758 1978 2184 2430 Sta 1480 Bank Sta: Left 1480 Right 1533 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S . Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft ) Q Total (cfs) Top Width (ft) Vel Total (ft/s ) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft ) num= Elev 234 .2 219.6 219. 2 209.7 215.5 218.7 227 227.2 227.9 num= n Val .07 43 Sta 1120 1350 1491 1533 1649 1778 1981 2272 2712 3 Sta 1533 Elev 232 216 .8 210.9 217 .7 217.8 220.2 227 226.9 234 n Val .085 Sta 1160 1360 1504 1575 1677 1782 2076 2286 Elev 228.9 219 208.4 218.5 218.l 220.5 226.8 227 Sta 1240 1363 1508 1587 1684 1825 2083 2369 Lengths: Left Channel Right 520 Coeff Contr. .1 570 614 Profile #PF 1 224.06 0 .21 223.86 0.002362 9161.00 579.60 3.02 15.76 188508.9 567.75 208 .10 1. 46 1.64 0 .01 Element Wt. n-Val . Reach Len . (ft) Flow Area (sq ft) Area (sq ft ) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per . (ft) Shear (lb/sq ft) Stream Power (lb/ft s ) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.075 570.00 909 .33 909.33 2110 . 06 242.40 2 .32 3.75 43419 .4 243.04 0.55 1.28 2017.94 405.57 Elev 223.7 219.7 208.l 218.5 218.l 224.6 226.7 227 .6 Expan. .3 Channel 0 .070 614.00 642.03 642 .03 3287.03 53.00 5 .12 12 .11 67638 .4 58 .07 1. 63 8.35 388.55 31. 63 Right OB 0.085 520.00 1478.86 1478.86 3763.91 284.20 2.55 5.20 77451.2 285.19 0.76 1.95 2730.79 562 .40 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections . CROSS SECTION REACH: Fema X-sect INPUT RIVER: Lick Creek Main RS: 31744 Description: Station Elevation Data num= 43 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 231.9 1073 230 1110 228.5 1147 225.9 1220 221.l 1293 219.l 1304 218.8 1320 217.3 1330 218 .4 1333 218.7 1367 218.5 1440 218.l 1452 208.8 1465 207 .3 1469 207.l 1473 207.6 1479 208.4 1495 216.7 1538 217.5 1549 217.5 1596 217 .2 1604 216.l 1611 217.2 1638 217.3 1646 217.4 1677 217.l 1719 217.5 1739 218.3 1743 218.4 1786 220.4 1840 220.7 1937 222.3 1941 222.3 2035 221. 6 2041 221.6 2132 222.4 2142 222.4 2229 222.6 2243 222.7 2326 223.5 2344 223.6 2394 224 2666 232 Manning 's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1440 .07 1495 .085 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan . 1440 1495 570 614 520 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 222.41 Element Left OB Channel Right OB Vel Head (ft) 0.31 Wt. n-Val. 0.075 0.070 0.085 w.s. Elev (ft) 222.11 Reach Len. (ft ) 570 .00 614.00 520.00 Crit W.S. (ft) Flow Area (sq ft) 703.86 642.74 1486. 71 E.G. Slope (ft/ft) 0 .003618 Area (sq ft) 703.86 642.74 1486. 71 Q Total (cfs) 9161.00 Flow (cfs) 1740.45 3971.33 3449.22 Top Width (ft) 851 .83 Top Width (ft) 235.29 55.00 561.54 Vel Total (ft/s) 3.23 Avg. Vel. (ft/s) 2.47 6.18 2.32 Max Chl Dpth (ft) 15.01 Hydr. Depth (ft) 2.99 11. 69 2.65 Conv. Total (cfs) 152298.l Conv. (cfs) 28934.3 66021.8 57341.9 Length Wtd. (ft) 558.03 Wetted Per. (ft) 235 .50 60.38 561.79 Min Ch El (ft) 207.10 Shear (lb/sq ft ) 0 .68 2 .40 0.60 Alpha 1.89 Stream Power (lb/ft s) 1 .67 14 .86 1.39 Frctn Loss (ft) 1.42 Cum Volume (acre-ft) 2007 .38 379.50 2713. 09 C & E Loss (ft) 0.06 Cum SA (acres) 402.45 30.87 557.35 Warning: Divided flow computed for this cross-section. Warning: The energy loss was greater than 1 .0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 31130 INPUT Description: Station Elevation Data num= 20 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 227.3 1100 225 1200 218 .4 1300 217 .8 1400 217.1 1412 206.7 1430 206.2 1440 207 1458 215.7 1500 216.5 1600 216.6 1700 216 .3 1800 216.l 1900 217.6 2000 216.4 2100 217 .7 2200 218.4 2300 219.6 2350 220 2620 230 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .075 1430 .07 1458 .085 Bank Sta: Left Right Lengths: Left Channel Right Coe ff Contr. Expan. 1430 1458 400 610 540 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E .G. Elev (ft) 220 .92 Element Left OB Channel Right OB Vel Head (ft) 0 .09 Wt. n-Val. 0.075 0.070 0.085 w.s. Elev (ft) 220.83 Reach Len. (ft) 400.00 610.00 540.00 Crit W.S. (ft) Flow Area (sq ft) 1022.77 313.05 3212.00 E.G. Slope (ft/ft) 0.001892 Area (sq ft) 1022.77 313.05 3212.00 Q Total (cfs) 9161.00 Flow (cfs) 2137.58 1379.68 5643.74 Top Width (ft) 1209 .39 Top Width (ft) 266.88 28.00 914.51 Vel Total (ft/s ) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) 2.01 14.63 210587.6 522.76 206.20 1.44 0.91 0.00 Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) 2 .09 3.83 49137 .4 270.85 0 .45 0.93 1996.08 399.16 CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 30520 INPUT Description: Station Elevation Sta Elev 884 227 .8 1242 216.2 Data 1520 216.4 1638 1689 1898 2177 2602 206.2 215.8 215.8 215 .9 221. 7 Manning's n Values Sta n Val 884 .085 Sta 1014 1271 1564 1640 1725 1929 2265 Sta 1600 Bank Sta: Left 1600 Right 1657 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) num= Elev 224.5 216 .8 216.2 208.6 216 215.7 216.3 num= n Val .07 36 Sta 1083 1421 1600 1649 1750 1968 2323 3 Sta 1657 Elev 223.4 216 .8 216.2 211. 2 215.8 215.6 217.7 n Val .085 Sta 1177 1435 1611 1657 1817 2041 2378 Elev 218 216.8 207 215 216 215.3 218.6 Sta 1228 1492 1627 1674 1828 2153 2490 Lengths: Left Channel Right 540 Coeff Contr. .1 400 610 Profile #PF 1 220.01 0.10 219.92 0.001606 9161.00 1347.49 1.87 14.82 228565.8 518.03 205.10 1. 77 1.12 0.01 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft ) Cum SA (acres) Left OB 0.085 400.00 1407.07 1407.07 2088.12 456.38 1. 48 3.08 52098.4 456.47 0.31 0.46 1984.93 395.84 4.41 11.18 31715.3 30.02 1. 23 5.43 372.76 30 .29 Elev 216.3 216.6 205 .1 215.7 216 216.l 219 .9 Expan. .3 Channel 0.070 610.00 640.06 640.06 2558.39 57.00 4.00 11. 23 63831 .5 62 .86 1.02 4.08 366.09 29 .69 1.76 3.51 129734.8 914 .58 0.41 0.73 2685.05 548 .54 Right OB 0.085 540.00 2844.20 2844.20 4514.49 834. 11 1.59 3.41 112635. 9 834.16 0.34 0.54 2647.51 537.70 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER : Lick Creek Main RS: 29910 INPUT Description: Station Elevat ion Data Sta Elev Sta 768 228 956 1284 1696 1836 1892 2123 2433 2804 214 215.8 205.3 215.4 215.2 214.4 223.8 1326 1748 1843 1919 2158 2531 num= Elev 223.4 215 215.2 207.4 215.5 215.1 216.3 36 Sta 1026 1542 1800 1848 1969 2201 2595 Elev 221.8 215.8 215.4 210.5 215.1 215 218 .2 Sta 1190 1592 1810 1 857 2033 2282 2659 Elev 216.5 216 207.2 214 .3 215.4 214.5 219.4 Sta 1263 1644 1824 1875 2046 2407 2780 Elev 213.8 215.6 204.1 215.4 215.4 214.7 221.4 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 768 .085 1800 .07 1857 .085 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1800 1857 400 610 540 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 218.89 Element Left OB Channel Right OB Vel Head (f t) 0.15 Wt . n-Val. 0.085 0.070 0.085 w.s. Elev (ft) 218.74 Reach Len. (ft) 400.00 610.00 540.00 Crit W.S. (ft) Fl ow Area (sq ft) 2142.73 619.01 2590.34 E .G. Slope (ft/ft) 0.002744 Area (sq ft) 2142.73 619.01 2590.34 Q Total (cfs) 12741.00 Flow (cfs) 4219.67 3181.65 5339.69 Top Width (ft) 1503 .31 Top Width (ft) 679.38 57.00 766.92 Vel Total (ft/s) 2.38 Avg. Vel. (f t/s) 1.97 5.14 2.06 Max Chl Dpth (ft) 14.64 Hydr. Depth (ft) 3.15 10.86 3 .38 Conv. Total (cfs) 243215.5 Conv. (cfs) 80550.1 60735.1 101930.3 Length Wtd. (ft) 501.43 Wetted Per. (ft) 679.49 62.29 767.01 Min Ch El (ft) 204 .10 Shear (lb/sq ft) 0.54 1. 70 0.58 Alpha 1.70 Stream Power (lb/ft s) 1. 06 8.75 1.19 Frctn Loss (ft) 1 .31 Cum Volume (acre-ft) 1968.63 357 .27 2613. 82 C & E Loss (ft) 0.01 Cum SA (acres) 390.63 28.89 527.78 Warning: The energy loss was g r eater than 1 .0 ft (0.3 m). between the curren t and previous cross section. This may indicate the need for additional c r oss sections. CROSS SECTION RI VER: Lick Creek Main REACH: Fema X-sect RS: 29300 INPUT Description : Station Elevation Data num= 36 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 652 228.9 897 222 .3 989 220.2 1203 214.3 1299 211. 2 1326 211. 8 1380 213 .3 1663 214.8 1728 215.1 1795 214.7 1864 214.6 1932 214.2 2000 214. 5 2009 207 .5 2022 203 2034 204.5 2041 206.3 2045 209.9 2056 213 .7 2077 215.2 2094 215 2114 215 2179 214.4 2250 214 .8 2264 214.8 2349 214.6 2387 214.5 2434 214. 4 2523 213 . 6 2660 213 .2 2688 212.9 2796 216.2 2867 218 .8 2933 220 .3 3069 222.9 3206 225.8 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 652 .085 2000 .07 2056 .085 Bank Sta: Left Right Lengths: Left Cha nnel Right Coeff Contr. Expan. 2000 2056 400 610 540 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 217 .57 El ement Left OB Channel Right OB Vel Head (ft) 0 .11 Wt. n -Val. 0.085 0 .070 0.085 w.s. Elev (ft) 217.45 Reach Len. (ft) 400.00 610.00 540.00 Crit W.S. (ft) Flow Area (sq ft) 2967.30 565.19 2378.09 E.G. Slope (ft/ft) 0.002508 Area (sq ft) 2967.30 565.19 2378.09 Q Total (cfs) 12741.00 Flow (cfs) 5706.05 2636.26 4398.70 Top Width (ft) 1741.66 Top Width (ft) 911. 41 56.00 774.25 Vel Total (f t/s) 2.16 Avg. Vel. (ft/s) 1 .92 4.66 1. 85 Max Chl Dpth (ft) 14.45 Hydr. Depth (ft) 3.26 10.09 3.07 Conv. Total (cfs) 254406 .6 Conv. (cfs) 113935.8 52639.6 87831.2 Length Wtd. (ft) 482.40 Wetted Per. (ft) 911. 54 61. 50 774.39 Min Ch El (ft) 203.00 Shear (lb/sq ft) 0.51 1. 44 0.48 Alpha 1.58 Stream Power (l b/ft s) 0.98 6. 71 0.89 Frctn Loss (ft) 0 .96 Cum Volume (acre-ft) 1945.17 348 .98 2583.03 C & E Loss (ft) 0.01 Cum SA (acres) 383.32 28.10 518.22 CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 28690 INPUT Description: Station Elevation Data num= 36 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 536 229.5 839 221.l 952 218 .6 1217 212.2 1334 208.6 1368 209 .5 1435 211 .7 1784 213.8 1864 214.3 1948 213.7 2032 213.6 2116 213.l 2200 213. 7 2208 207.8 2219 202 2232 203.6 2240 205 .l 2245 209.2 2256 213 2278 214 .9 2297 214.6 2318 214.4 2390 213. 7 2467 214.2 2482 214.3 2574 214 2616 213. 9 2667 213.7 2764 212.8 2913 211.8 2944 211.5 3062 216.1 3130 219 .4 3211 221.l 3359 224.5 3508 227.9 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 536 .085 2200 .07 2256 .085 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 2200 2256 400 610 540 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 216.59 Element Left OB Channel Right OB Vel Head (f t) 0.07 Wt. n-Val. 0.085 0.070 0.085 w.s . Elev (ft) 216.53 Reach Len. (ft) 400 .00 610.00 540.00 Crit W.S. (ft) Flow Area (sq ft) 4253.69 556.47 2431.14 E.G. Slope (ft/ft) 0.001627 Area (sq ft) 4253.69 556.47 2431.14 Q Total (cfs) 12741.00 Flow (cfs) 7123. 93 2064.27 3552 .80 Top Width (ft) 2032.86 Top Width (ft) 1162.10 56.00 814.76 Vel Total (f t/s) 1. 76 Avg. Vel. (ft/s) 1.67 3. 71 1 .46 Max Chl Dpth (ft) 14.53 Hydr. Depth (ft) 3.66 9.94 2 .98 Conv. Total (cfs) 315839.3 Conv. (cfs) 176596.6 51171.5 88071. 2 Length Wtd. (ft) 464.81 Wetted Per. (ft) 1162.27 61.72 814.97 Min Ch El (ft) 202.00 Shear (lb/sq ft) 0.37 0.92 0.30 Alpha 1. 42 Stream Power (lb/ft s) 0.62 3.40 0 .44 Frctn Loss (ft) 0. 48 Cum Volume (acre-ft) 1912.01 341.13 2553.22 C & E Loss (ft) 0.01 Cum SA (acres) 373.80 27.32 508 .37 War ning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections . CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect INPUT Description: Station Elevation Data Sta Elev Sta 420 230 780 2000 213.4 2100 2416 200.9 2438 2500 214.2 2600 3200 210 3410 Manning's n Values Sta n Val 420 .085 Bank Sta: Left 2400 Sta 2400 Right 2455 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) RS: 28080 num= 23 El ev Sta Elev Sta 220 1230 210 1370 212 .8 2200 212 .7 2300 203.9 2444 208.5 2455 213 2700 213.7 2800 220 3810 230 num= 3 n Val Sta n Val .07 2455 .085 Lengths: Left Channel Right 515 825 870 Prof ile #PF 1 216.10 0.03 216 .07 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft ) Elev Sta 206 1490 212.l 2400 212.3 2479 213 .4 2900 Coeff Contr. .1 Left OB 0.085 825 .00 6515.33 Elev 210 212.8 214 .6 213 .1 Expan . . 3 Channel 0.070 870.00 569.90 Right OB 0 .085 515.00 2894.68 E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 0.000713 12741.00 2370.69 1.28 15.17 477089.l 734.49 200.90 1. 24 0 .71 0.00 Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per . (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) 6515 .33 8307.74 1443.19 1.28 4.51 311084. 7 1443.40 0.20 0.26 1862 .57 361.84 CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 27210 INPUT Description: Station Elevation Sta Elev 410 230 1189 1563 1706 1860 2046 2106 2275 2668 210.6 212.2 212.6 212.1 204.3 212.l 213 211.4 Manning's n Values Sta n Val 410 .085 Data Sta 708 1227 1642 1708 1870 2056 2134 2310 2977 num= Elev 222.1 210 .8 212.3 212.3 212 .l 201.7 213. 4 213.2 210 num= Sta n Val 2034 . 07 45 Sta 922 1288 1652 1819 1947 2063 2144 2392 3222 3 Sta 2106 Elev 217.l 211 210.7 212 .2 211.9 200 213 .4 213.l 215 n Val .085 Sta 1074 1307 1668 1829 1952 2087 2158 2509 3323 Elev 213. 7 210.7 212.5 212.3 211.9 205.l 213. 3 212.4 216.l Sta 1178 1435 1691 1847 2034 2094 2231 2626 3690 Bank Sta: Left 2034 Right 2106 Lengths: Left Channel Right 515 Coeff Contr. .1 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) 825 870 Profile #PF 1 215.39 0.07 215.32 0. 001394 12741.00 2250.02 1.63 15.32 341212.7 686.15 200.00 1.58 0.91 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/ sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.085 825.00 3492.73 3492.73 5133.85 1032.49 1. 47 3.38 137487.9 1033.66 0.29 0.43 1767.80 338.40 CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 26340 INPUT Description: Station Elevation Sta Elev 400 230 1200 211. l 1400 211 . 7 1600 211.6 1756 211.9 3150 210 Manning's n Values Data Sta 800 1300 1500 1668 1800 3570 num= Elev 220 212 .2 211. 7 213 . 6 212.3 220 num= 27 Sta 1000 1362 1508 1685 1900 3 Elev 215.6 211 .8 211. 9 200 .6 212.9 Sta 1038 1370 1522 1700 2000 Elev 214 208 204.4 199.7 213.2 Sta 1100 1376 1532 1710 2400 569.90 1427 .79 55.00 2.51 10.36 53464.0 61.34 0.41 1.04 333.24 26.54 Elev 211 211 . l 212.5 208.6 213.2 208.4 213. 2 211. 7 225 Expan. . 3 Channel 0.070 870.00 730.75 730.75 2589.46 72.00 3.54 10.15 69347.4 77.31 0.82 2.92 320.25 25 .27 Elev 211.3 211. 9 211. 5 199.1 210 2894.68 3005.47 872 .49 1.04 3.32 112540. 5 872.78 0.15 0.15 2520.21 497.92 Right OB 0.085 515.00 3589.76 3589.76 5017.70 1145.53 1.40 3.13 134377.4 1145.62 0.27 0 .38 2481. 87 485.99 Sta 400 n Val .08 Sta 1668 Bank Sta: Left 1668 Right 1756 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) n Val .065 Sta 1756 n Val .085 Lengths: Left Channel Right 1283.3 1850 1473.3 Profile #PF 1 214.48 0.07 214.40 0.001260 12741.00 2306.43 1. 62 15.30 358928.6 1529 .37 199 .10 1.83 2.10 0.00 Element Wt. n-Val. Reach Len. (ft) Fl ow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per . (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Coeff Contr. .1 Left OB 0 .080 1283.30 1739.52 1739.52 2220.31 639.55 1.28 2.72 62548.7 645.81 0.21 0.27 1718.25 322.56 Expan. . 3 Channel 0.065 1850 .00 897.42 897.42 3272 .82 88.00 3.65 10.20 92199.0 94.19 0.75 2.73 303.99 23.68 Right OB 0.085 1473.30 5245.79 5245.79 7247.87 1578.88 1. 38 3.32 204180.9 1578.95 0 .26 0.36 2429.64 469.88 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections . CROSS SECTION REACH: Fema X-sect INPUT Description: Station Elevation Sta Elev 400 226.7 1071 1137 1335 1471 1615 1760 1830 2012 2393 2811 211. 7 208.l 209.2 209.4 209.4 210.2 197 210.3 208.9 208.4 Manning's n Val ues Sta n Val 400 .08 RIVER: Lick Creek Main RS: 24490 Data Sta 839 1084 1162 1387 1497 1631 1791 1842 2080 2497 3235 num= Elev 217.3 209.5 209.4 209.5 209.3 204.4 210 .8 200.4 210.5 208.5 209.2 num= Sta n Val 1791 .065 53 Sta 910 1092 1168 1420 1505 1642 1807 1871 2110 2501 3607 3 Sta 1871 Elev 215.9 211.1 209 209.4 209.3 209.2 199.3 209.8 210.6 208.5 216.7 n Val .085 Sta 995 1100 1250 1455 1590 1675 1809 1914 2184 2602 Elev 214.7 210.9 209 209.3 209.3 209.3 198.8 210 210 .3 208 .4 Sta 1058 1129 1278 1464 1607 1716 1820 1975 2289 2706 Bank Sta: Left 1791 Right 1871 Lengths: Left Channel 1283.3 1850 Right 1473.3 Coef f Contr. .1 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) Profile #PF 1 212.38 0 .09 212.29 0.001510 12741.00 2330.12 1. 71 15.29 327922 .8 1508.79 197.00 1.92 2.15 0.00 El ement Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.080 1283.30 2158.23 2158.23 3190.96 732.80 1.48 2.95 82127 .7 735.98 0.28 0. 41 1660.83 302.35 Elev 212.3 210.3 208.9 207 209.3 209 .4 197.8 210.l 209.6 208 .5 Expan. . 3 Channel 0.065 1850.00 816.78 816.78 3258.56 80.00 3.99 10.21 83867 .6 85.80 0.90 3.58 267.59 20 .11 Right OB 0.085 1473.30 4492.43 4492.43 6291.47 1517.31 1.40 2.96 161927.4 1517.35 0.28 0.39 2264.96 417.52 Warning: The energy loss was greater than 1.0 ft (0 .3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 22640 INPUT Description: Station Elevation Sta Elev 400 223.3 1131 208 .3 1202 1417 1565 1723 1880 1949 2123 2497 2905 203.6 206.7 206 .8 207 207.7 195 207.7 206.9 206.9 Manning's n Values Sta n Val 400 .07 Data Sta 878 1145 1230 1475 1594 1740 1914 1960 2190 2599 3321 Sta 1914 Bank Sta: Left 1914 Right 1985 CROSS SECTION OUTPUT E.G. Elev (f t) Vel Head (ft) w.s. Elev (ft) Crit W.S . (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s} Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Al pha Frctn Loss (ft) c & E Loss (ft) num= Elev 214.5 204.4 207.3 206.8 206.8 204.5 208 197.9 207.8 206.9 208.5 num= n Val .06 53 Sta 955 1153 1236 1510 1602 1752 1928 1985 2219 2602 3723 3 Sta 1985 Elev 213.2 207.9 207.2 206.7 206.8 206.9 198.l 207.6 208 206 .9 213.3 n Val .07 Sta 104 7 1162 1325 1549 1695 1787 1931 2027 2292 2701 Elev 212.5 207.9 206.9 206.8 206.8 207 197.1 207.6 208 206.7 Sta 1116 1194 1355 1558 1713 1833 1941 2088 2394 2803 Lengths: Left Channel Right 1473.3 Coeff Contr. .1 1283.3 1850 Profile #PF 1 210 .23 0.09 210.14 0.001349 12741 .00 2363.45 1.80 15.14 346955.8 1485.86 195.00 1.75 2.46 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (l b/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.070 1283 .30 2600.57 2600 .57 4367.85 819. 11 1.68 3.17 118942. 8 822.26 0.27 0.45 1590.73 279.49 Elev 209.l 207.7 206.8 205.6 206.9 207 .2 195.9 207.6 207.4 207.l Expan. .3 Channel 0.060 1850.00 726.14 726 .14 2957.33 71. 00 4.07 10.23 80532.3 76.62 0.80 3.25 234.83 16.90 Right OB 0.070 1473.30 3736.17 3736.17 5415.82 1473 .35 1.45 2.54 147480.7 1473.37 0.21 0 .31 2125.80 366.95 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect INPUT Description: Station Elevation Sta Elev 400 220 1214 204.7 1500 204 .2 2000 205.2 2100 205 .5 2600 204 .9 3800 210 Manning's n Values Sta n Val 400 .07 RIVER: Lick Creek Main RS: 20790 Data Sta 1000 1258 1600 2037 2200 2700 Sta 2037 num= Elev 210.5 205.2 204 .l 205.2 205 205 .4 num= n Val .06 31 Sta 1100 1267 1700 2052 2300 2800 3 Sta 2100 Elev 210.3 199.1 204.4 195.5 205.2 205.l n Val .07 Sta 1190 1297 1800 2069 2400 2900 El ev 204.9 205.2 204.4 192.9 205.7 205.6 Sta 1205 1400 1900 2078 2500 3000 Elev 199.3 204 .8 204.7 195.5 205.2 205.3 Bank Sta: Left 2037 Right 2100 CROSS SECTION OUTPUT E.G . Elev (ft) Vel Head (ft) W.S . Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft ) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) Lengths: Left Channel Right 575 575 605 Profile #PF 1 207 .77 0.13 207 .64 206 .37 0.002071 12730.00 2254 .09 2.12 14.74 279728.9 581.19 192 .90 1. 83 1.10 0.01 El ement Wt. n-Val. Reach Len . (ft) Flow Area (sq ft) Area (sq ft ) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Coeff Contr. .1 Left OB 0.070 575.00 2795.69 2795.69 5759.22 892.68 2.06 3.13 126553 .l 897.76 0 .40 0.83 1511 . 25 254.27 Expan. .3 Channel 0.060 605.00 615.91 615.91 2998.74 63.00 4.87 9.78 65894.3 68.59 1.16 5.65 206.33 14.06 Right OB 0.070 575 .00 2592.88 2592 .88 3972 .04 1298.41 1 .53 2 .00 87281.6 1298.43 0.26 0.40 2018.77 320.07 Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 20185 INPUT Description: Station Elevation Sta Elev 540 220 1238 206.6 1538 203.4 1785 203.l 2048 203.7 2285 2457 2500 2840 3066 3519 203.8 196.8 204.l 203.9 203.5 205.6 Manning's n Values Sta n Val 540 .07 Data Sta 636 1354 1548 1819 2052 2312 2460 2590 2850 3127 3933 num= Elev 214 .3 206.3 200.4 202.9 203.7 204.2 195.8 203.2 203.9 203.6 208.7 num= Sta n Val 2444 . 055 53 Sta 821 1459 1583 1873 2136 2399 2470 2613 2948 3179 4425 3 Sta 2500 Elev 212.l 203 .4 203.4 202 .7 203.3 204 .l 194.6 203.2 203.7 204 215 n Val .07 Sta 864 1476 1698 1936 2168 2401 2478 2726 2953 3293 Elev 210.8 200.6 203 202.7 203 .2 204.l 194 203.5 203.7 204 .4 Sta 908 1487 1703 1961 2224 2444 2484 2769 3037 3406 Bank Sta: Left 2444 Right 2500 Lengths: Left Channel Right 575 Coeff Contr. .l CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (f t) Vel Total (ft/s) Max Chl Dpth (ft ) Conv. Total (cfs ) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 575 605 Profile #PF 1 206.66 0 .09 206.56 0.001731 12730.00 2395 .85 1.91 12.56 305928 .6 578.86 194.00 1. 67 0.49 0.02 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft ) Stream Power (lb/ft s ) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.070 575.00 3504.05 3504.05 6346 .89 1192 .10 1.81 2. 94 152529.0 1193. 28 0.32 0.57 1469.67 240 .51 Elev 209 .5 203 .3 203 202 .7 203 203.8 196.4 203.6 203 .6 205.2 Expan. .3 Channel 0 .055 605 .00 4 93. 19 493.19 2252.18 56.00 4.57 8.81 54124 .7 60.24 0.88 4. 04 198 .62 13.23 Right OB 0.070 575.00 2666.28 2666 .28 4130 .93 1147.75 1.55 2.32 99274.9 1147. 76 0.25 0.39 1984.06 303.93 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is l ess than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 19580 INPUT Description: Station Elevation Sta Elev 680 220 2000 201 .l 2500 2865 3200 4500 202.2 196.4 201 .9 210 Data Sta 790 2100 2600 2879 3300 5030 Manning's n Values Sta n Val 680 .07 Sta 2851 Bank Sta: Left 2851 Right 2900 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Cri t W. S. (ft) E.G. Slope (ft/ft) Q Total (cfs ) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs ) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) num: Elev 210 201.8 201.5 195.3 202.l 220 num: n Val .055 27 Sta 1000 2200 2700 2887 3400 3 Sta 2900 Elev 208 201. 2 203 .6 195.l 202 .l n Val .07 Sta 1050 2300 2800 2900 3500 El ev 206 201.3 203 202.6 202.2 Sta 1100 2400 2851 3000 3600 Lengths: Left Channel Right 1300 Coeff Contr. .1 1650 1650 Profile #PF 1 206.14 0.03 206.12 0.000507 12730.00 3010.70 1.16 11. 02 565086.3 1534.91 195 .10 1 .20 0 .55 0 .00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cf s) Top Width (ft) Avg . Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s ) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.070 1650.00 6661.06 6661 .06 7609.40 1803.95 1.14 3 .69 337782 .3 1804 .05 0.12 0 .13 1402 .58 220.74 CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 17930 INPUT Description: Station Elevation Sta Elev 840 214.8 1116 1600 1973 2207 2458 2486 2759 3021 3440 3907 202.3 199.8 199.4 200.l 199 1 93.5 200.3 200.4 202.7 206.7 Manning's n Values Sta n Val 840 . 07 Data Sta 922 1144 1752 2047 2271 2467 2497 2846 3089 3556 4024 Sta 2458 Bank Sta: Left 2458 Right 2497 CROSS SECTION OUTPUT num: Elev 208.2 201.3 199.6 199.4 199.8 194.3 200.5 200.2 200.5 204 208.2 num: n Val .055 55 Sta 927 1153 1824 2055 2345 2472 2584 2855 3108 3673 4141 3 Sta 2497 Elev 208.1 201 199.4 199.5 200.7 193.l 199.7 200.2 200.5 204.5 210.5 n Val .07 Lengths : Left Channel 1650 1650 Profile #PF 1 Sta 992 1296 1898 2122 2359 2477 2621 2934 3206 3790 4258 Right 1300 Elev 205.2 200.5 199.7 200.5 200.6 192.6 199.7 200.3 201 .3 205 .7 212.6 Sta 1078 1448 1903 2196 2420 2482 2738 2972 3323 3895 4375 Coeff Contr. .l Elev 204 203.l 202 .4 201. 3 202 .1 Expan. .3 Channel 0.055 1650.00 419.63 419.63 1023.79 49.00 2.44 8 .56 45446.0 52.29 0.25 0.62 192 .29 12.50 Elev 203.7 201.l 199 .6 200.2 199 .8 192.2 200 .3 200.3 202.5 206.6 214.7 Expan. .3 Right OB 0.070 1300. 00 3847.26 3847.26 4096.81 1157.75 l. 06 3.32 181858.0 1157.78 0.11 0.11 1941.07 288. 71 E.G. Elev (ft) Vel Head (ft ) W.S. Elev (ft) Cr it W.S. (ft) E.G. Slope (ft/ft) Q Total (cf s) Top Width (ft ) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) CROSS SECTION REACH : Fema X-sect INPUT Descr iption: 205.59 0.02 205.58 0.000265 12730.00 2794.31 0.99 13.38 782698.2 1519.56 192.20 1.16 0 .31 0 .00 El ement Wt. n-Val . Reach Len. (ft) Flow Area (sq ft) Area (sq ft ) Flow (cfs) Top Width (ft) Avg. Vel . (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb /sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) RIVER: Lick Creek Main RS: 16280 Left OB 0.070 1650 .00 7480.04 7480.04 7624.34 1474.42 1. 02 5.07 468778.8 1474.53 0.08 0 .09 1134. 75 158.65 Station Elevation Data num= 33 Sta Elev 1000 209.7 1400 199. 4 1900 198 .2 2081 2500 3000 3500 190.2 198.5 201.3 205.9 Manning's n Values Sta n Val 1000 .07 Sta 1057 1500 2000 2094 2600 3100 3600 Elev 206.3 197.5 197.8 198 .4 198.8 201. 2 207.7 num= Sta n Val 2065 .055 Sta 1100 1600 2065 2200 2700 3200 3700 3 Sta 2094 Elev 201.3 197.8 195.7 198 199.5 202.5 209.4 n Val .07 Sta 1200 1700 2072 2300 2800 3300 El ev 198.l 197.5 190.4 198.8 200 .8 203 .2 Sta 1300 1800 2077 2400 2900 3400 Bank Sta: Left 2065 Right 2094 Lengths: Left Channel 482.5 500 Right 485 Coeff Contr. .1 CROSS SECTION OUTPUT E.G. Elev (ft ) Vel Head (ft ) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft ) Alpha Frctn Loss (ft) C & E Loss (ft) CROSS SECTION REACH: Fema X-sect INPUT Description: Profile #PF 1 205.29 0.01 205.27 0.000158 12730.00 2405.63 0.90 16.07 1011354 . 9 484.75 189.20 1.12 0.06 0.00 Element Wt. n-Val . Reach Len. (ft ) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs ) Wetted Per. (ft) Shear (lb/sq ft ) Stream Power (lb/ft s) Cum Vol ume (acre-ft) Cum SA (acres) RIVER: Lick Creek Main RS : 15780 Left OB 0.070 482.50 7031.79 7031.79 6898.25 999.16 0.98 7.04 548042.5 999.51 0.07 0.07 859 .91 111. 80 Station Elevation Data num= Elev 36 Sta Elev 1000 209.8 1446 200.2 1846 197 .9 2200 189.6 2463 197.l 3017 199.9 Sta 1064 1558 1893 2200 2574 3127 207 198.3 197.6 188.l 197 199.6 Sta 1112 1610 2005 2214 2685 3238 Elev 203 198.2 197.4 189.2 197 .4 200.8 Sta 1223 1670 2116 2236 2795 3314 Elev 200.2 198.3 196.3 196.3 197.9 200 .9 Sta 1335 1781 2189 2353 2906 3349 Channel 0.055 1650.00 414.45 414 .45 830.21 39.00 2.00 10.63 51045.0 42.58 0.16 0.32 176.49 10.83 Elev 197.7 197.6 189 .2 198.3 200 203.7 Expan. . 3 Channel 0 .055 500 .00 367.84 367.84 619.01 29.00 1. 68 12 .68 49178 .6 33.42 0 .11 0.18 161.67 9.55 Elev 199.4 197.9 194.3 196.3 198.7 201 Right OB 0.070 1300.00 4997 .11 4997. 11 4275.46 1280.89 0.86 3 .90 262874 .4 1280.92 0.06 0.06 1809.10 252.32 Right OB 0.070 485.00 6757.49 6757.49 5212 .73 1377.46 0.77 4.91 414133.8 1377.52 0.05 0.04 1633 .69 212.65 3459 202.4 3570 203 .3 3681 204.1 3791 206.l 3902 207 .9 4013 209.6 Manning 's n Val ues num= 3 Sta n Val Sta n Val Sta n Va l 1000 .065 2189 .05 2236 .065 Bank Sta: Left Right Lengths: Lef t Channel Right Coef f Contr. Expan . 2189 2236 482.5 500 485 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E .G. Elev (ft ) 205.23 El ement Left OB Channel Right OB Vel Head (ft ) 0.01 Wt. n-Val. 0.065 0.050 0.065 w.s. Elev (f t) 205.22 Reach Len. (ft) 482.50 500.00 485.00 Crit W.S. (f t) Fl ow Area (sq ft) 7219.46 652.08 8523.09 E.G. Sl ope (f t /ft ) 0.000096 Area (sq ft) 7219.46 652 .08 8523.09 Q Total (cfs) 12730.00 Flow (cfs) 5642.03 1040.87 6047.11 Top Width (f t) 2656.94 Top Width (ft) 1103. 59 47.00 1506 .35 Vel Total (f t/s) 0.78 Avg. Vel. (ft/s) 0.78 1. 60 0. 71 Max Chl Dpth (ft) 17.12 Hydr. Depth (ft) 6 .54 13.87 5 .66 Conv. Total (cfs) 1302358.9 Conv . (cfs) 577214.8 106487.0 618657.1 Length Wtd. (ft) 485 .45 Wetted Per . (ft) 1103.77 50.62 1506.40 Min Ch El (f t) 188.10 Shear (lb/sq ft) 0.04 0.08 0.03 Alpha 1.19 Stream Power (lb/ft s) 0.03 0.12 0.02 Frctn Loss (ft) 0.04 Cum Volume (acre-ft) 780.98 155 .82 1548.63 C & E Loss (f t) 0.00 Cum SA (acres) 100.15 9.11 196.60 CROSS SECTION RI VER: Lick Creek Main REACH: Fema X-sect RS: 15280 INPUT Description: Station Elevation Data num= 36 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 209.9 1070 207.6 1123 204 .7 1246 202.2 1370 201.1 1493 201 1616 199.2 1673 198.8 1739 198.8 1863 198 .4 1934 198.3 1986 197.7 2109 196.5 2232 194. 9 2313 192.8 2328 188.7 2339 187.1 2348 188.2 2377 194.2 2506 194 . 5 2627 195.5 2748 195.7 2869 198 .3 2991 197 3112 197.9 3233 199 3355 199.1 3476 200.3 3559 200 .6 3597 200.8 3719 202.3 3840 203.4 3961 204.5 4082 206 .4 4204 208.1 4325 209.7 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .065 2313 .05 2377 .065 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 2313 2377 482.5 500 485 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 205.19 El ement Left OB Channel Right OB Vel Head (ft) 0.01 Wt . n -Val. 0.065 0.050 0 .065 w.s. Elev (ft ) 205.18 Reach Len. (f t) 482.50 500.00 485.00 Crit W.S. (ft ) Flow Area (sq ft) 7307 .76 969 .57 10304.38 E.G. Slope (ft/ft ) 0.000069 Area (sq ft) 7307 .76 969.57 10304 .38 Q Total (cf s) 12730.00 Flow (cfs) 4614.94 1440 .31 6674.75 Top Width (f t) 2889.88 Top Width (ft) 1198. 73 64.00 1627.15 Ve l Total (f t/s) 0.69 Avg. Vel . (ft/s) 0.63 1.49 0.65 Max Chl Dpth (ft) 18.08 Hydr. Depth (ft) 6.10 15.15 6.33 Conv. Total (cfs) 1537724.1 Conv. (cfs) 557463.3 173982.1 806278.6 Length Wtd. (ft) 486 .04 Wetted Per. (ft) 1198. 83 65 .35 1627.23 Min Ch El (ft ) 187.10 Shear (lb/sq ft) 0.03 0.06 0.03 Alpha 1. 31 Stream Power (lb/ft s) 0.02 0.09 0.02 Frctn Loss (ft) 0.03 Cum Volume (acr e-ft) 700.52 146.51 1443.81 C & E Loss (ft) 0.00 Cum SA (acres) 87.40 8 .47 179.16 CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 14780 INPUT Description: Station Elevat ion Data num= 36 Sta Elev Sta Elev Sta Elev Sta El ev Sta Elev 1000 209.9 1077 208.3 1135 206.3 1270 204.3 1405 202.8 1539 201.9 1674 200 1737 199.4 1809 199.3 1944 198.8 2022 198 .6 2079 197.7 2214 195.7 2349 193.4 2436 191.4 2456 187.9 2469 186.1 2481 187.2 2519 192.l 2658 192.8 2790 193.8 2922 194.4 3054 195.2 3186 196.l 3318 197 3450 198 .l 3582 198.7 3714 199.8 3805 200.3 3846 200 .7 3978 202.2 4110 203.5 4242 204.9 4374 206.6 4500 208.2 4638 209 .9 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .065 2436 .05 2519 .065 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 2436 2519 482.5 500 485 .1 .3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 205.16 Element Left OB Channel Right OB Vel Head (ft) 0.01 Wt. n-Val. 0.065 0.050 0 .065 w.s . Elev (ft) 205.15 Reach Len. (ft) 482.50 500.00 485.00 Crit W.S. (ft) Flow Area (sq ft) 7353.53 1357.18 12795.90 E.G. Slope (ft/ft) 0.000044 Area (sq ft) 7353.53 1357.18 12795.90 Q Total (cfs) 12730.00 Flow (cfs) 3686.16 1 712. 86 7330.98 Top Width (ft) 3049.19 Top Width (ft) 1223.56 83.00 1742.63 Vel Total (ft/s) 0.59 Avg . Vel. (ft/s) 0.50 1.26 0.57 Max Chl Dpth (ft) 19.05 Hydr. Depth (ft) 6 .01 16.35 7.34 Conv. Total (cfs) 1918910.8 Conv. (cfs) 555648 .7 258196.0 1105066 .1 Length Wtd. (ft) 486 .44 Wetted Per. (ft) 1223.66 83.79 1742.68 Min Ch El (ft) 186 .10 Shear (lb/sq ft) 0 .02 0.04 0.02 Alpha 1.36 Stream Power (lb/ft s) 0 .01 0.06 0.01 Frctn Loss (ft) 0.02 Cum Volume (acre-ft) 619 .32 133 .16 1315. 21 C & E Loss (ft) 0.00 Cum SA (acres) 73.99 7.63 160.40 CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 14280 INPUT Description: Station Elevation Data num= 8 Sta El ev Sta Elev Sta Elev Sta Elev Sta Elev 1000 210 1800 200 2110 199 2560 190 2600 185 2660 190 4050 200 4950 210 Manning 's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .065 2560 .05 2660 .065 Bank Sta: Left Right Lengths : Left Channel Right Coef f Contr. Expan. 2560 2660 300 375 450 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 205.14 El ement Left OB Channel Right OB Vel Head (ft) 0.01 Wt. n-Val. 0.065 0.050 0.065 w.s. Elev (ft) 205.14 Reach Len. (ft) 300.00 375.00 450.00 Crit W.S. (ft) Flow Area (sq ft) 7589.59 1763.69 15277 .80 E.G. Slope (ft/ft) 0.000029 Area (sq ft) 7589.59 1763.69 15277.80 Q Total (cfs) 12730.00 Flow (cfs) 3222.15 1890.84 7617.02 Top Width (ft) 3123.28 Top Width (ft) 1170. 95 100.00 1852.32 Vel Total (ft/s) 0.52 Avg. Vel. (ft/s ) 0.42 1.07 0.50 Max Chl Dpth (ft) 20 .14 Hydr. Depth (ft) 6.48 17.64 8.25 Conv . Total (cfs) 2382713.5 Conv. (cfs) 603098.9 353913.7 1425701.0 Length Wtd. (ft) 417.84 Wetted Per. (ft) 1171.08 100.52 1852.39 Min Ch El (ft) 185 .00 Shear (lb/sq ft) 0.01 0.03 0.01 Alpha 1 .37 Stream Power (lb/ft s) 0.00 0.03 0.01 Frctn Loss (ft) 0.02 Cum Volume (acre-ft) 536 .56 115. 25 1158. 93 C & E Loss (ft ) 0.00 Cum SA (acres) 60.73 6.58 140. 38 CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 13905 INPUT Description: Station Elevation Data num= 30 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 206.l 1100 201 .4 1200 196 .7 1239 194.6 1300 194.8 1335 199 1335 188.9 1335.7 187.l 1336. 1 186.3 1337.4 185.7 1339 185.4 1340.6 185.7 1341. 9 186 .3 1342. 3 187.l 1343 188.9 1343 199 1400 198.l 1500 191.8 1600 191.4 1700 191.6 1810 191 .9 1900 192.5 2000 193 .l 2100 193.4 2200 193 2300 194.3 2400 194.8 2500 194.4 2600 200.l 4300 210 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .06 1335 .OS 1343 .06 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1335 1343 1 1 1 . 3 .3 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1335 198.6 1343 4300 195.4 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (f t) 205 .13 Element Left OB Channel Right OB Vel Head (ft) 0 .01 Wt. n-Val. 0.060 0.050 0.060 w.s. Elev (ft) 205.12 Reach Len. (ft) 1. 00 1. 00 1. 00 Crit W.S. (ft) 195.41 Flow Area (sq ft) 2046.81 151.04 16556.26 E.G. Slope (ft/ft) 0 .000050 Area (sq ft) 2046 .81 151.04 16556.26 Q Total (cfs) 12730.00 Flow (cfs) 1246 .78 89.20 11394 . 02 Top Width (ft) 2441 .13 Top Width (ft) 314.14 8.00 2118. 99 Vel Total (ft/s) 0.68 Avg. Vel. (ft/s) 0.61 0.59 0.69 Max Chl Dpth (ft) 19.72 Hydr. Depth (ft) 6.52 18.88 7.81 Conv. Total (cfs) 1803539.l Conv. (cfs) 176639.1 12637.7 1614262.3 Length Wtd. (ft ) 1. 00 Wetted Per. (ft) 314.65 31.97 2119.39 Min Ch El (ft) 185.40 Shear (lb/sq ft) 0.02 0.01 0.02 Alpha 1. 00 Stream Power (l b /ft s) 0.01 0.01 0.02 Frctn Loss (ft) 0.00 Cum Volume (acre-ft) 503.38 107.01 994.49 C & E Loss (ft) 0.00 Cum SA (acres) 55.61 6 .11 119. 87 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1 .4 . This may indicate the need for additional cross sections. Warning: The parabolic search method failed to converge on critical depth . The program will try the cross section slice/secant method to find critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 13904 INPUT Description: Station Elevation Data num= 30 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 206.l 1100 201. 4 1200 196.7 1239 198.6 1300 198.8 1335 199 1335 189 1335. 7 188 1336. 1 187.2 1337.4 186.6 1339 186.3 1340. 6 186 .6 1341.9 187 1342. 3 188 1343 189.8 1343 199 1400 198.1 1500 195 .8 1600 195.4 1700 195 .6 1800 195.9 1900 196.5 2000 197.1 2100 198.4 2200 197.9 2300 197.3 Manning's n Values Sta n Val 1000 .025 2400 Sta 1339 Bank Sta: Left 1339 Right 1400 CROSS SECTION OUTPUT E .G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) 198.8 num= n Val .02 2500 3 Sta 1400 198.4 n Val .025 2600 Lengths: Left Channel Right 47 Profile #PF 1 205.13 0.01 205 .11 198.43 0.000024 12730 .00 2439.59 47 47 El ement Wt. n-Val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) 200 .l 4300 Coeff Contr. .3 Left OB 0.025 47 .00 1724.47 1724.47 1498.87 Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) C & E Loss (ft) 0.92 18 .81 2624644.8 47 .00 186.30 1. 01 Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) 317.98 0.87 5.42 309033.l 329.39 0.01 0 .01 503.34 55.60 CULVERT REACH: Fema X-sect INPUT Description: Bridge #1 RIVER: Lick Creek Main RS: 13880 .5 Distance from Upstream XS 0 Deck/Roadway Width 47 Weir Coefficient 2.6 Bridge Deck/Roadway Skew Upstream Deck/Roadway Coordinates num= 28 Sta Hi Cord Lo Cord 1000 206 .l Sta Hi Cord Lo Cord 1100 201. 4 Sta Hi Cord Lo Cord 1200 196.7 1239 198.6 1335.7 1339 1342. 3 1500 1800 2100 2400 199 199 199 195.8 195.9 197.4 198.8 4300 210 1300 198. 8 1336.l 1340.6 1343 1600 1900 2200 2500 199 199 199 195.4 196 . 5 197.9 199.4 Upstream Bridge Cross Section Data Station Elevation Data num= 30 Sta 1200 1335.7 Sta Elev Sta Elev 1000 206.l 1100 201.4 1335 199 1335 189 1339 1343 1800 2300 186.3 1340.6 199 1400 195.9 1900 197.3 2400 Manning's n Val ues Sta n Val Sta 1339 1000 .025 Bank Sta: Lef t 1339 Right 1400 186. 6 1341. 9 198.1 1500 196.5 2000 198.8 2500 num= n Val .02 3 Sta 1400 Coeff Contr. .3 Downstream Deck/Roadway Coordinates num= 28 1335 199 Elev 196.7 188 1337.4 1341. 9 1400 1700 2000 2300 2600 Sta 1239 1336.l 187 1342.3 195. 8 1600 197.1 2100 198.4 2600 n Val .025 Expan. .3 199 199 198.l 195.6 197.l 198.3 200.1 Elev 198.6 187.2 188 195.4 198.4 200.l Sta 1300 1337.4 1343 1700 2200 4300 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 210 Expan. .3 Channel 0.020 47.00 446.08 446.08 541.22 61.00 1. 21 7.31 111588 . 2 72.20 0.01 0.01 107.00 6 .11 Elev 198.8 186.6 189.8 195.6 197.9 210 Right OB 0.025 47.00 11670. 86 11670. 86 10689.91 2060.62 0 .92 5.66 2204023.5 2060 .70 0 .01 0.01 994.17 119 .82 1000 206.l 1100 201 1239 198.6 1300 198 .8 1335.7 199 1336. 1 199 1339 199 1340.6 199 1342.3 199 1343 199 1500 195.8 1600 195.4 1800 195.9 1900 196.5 2100 197.4 2200 197.9 2400 198.8 2500 199.4 4300 210 Downstream Bridge Cross Section Data Station Elevation Data num= 30 Sta Elev Sta Elev Sta Elev 1000 206 .l 1100 201.4 1200 196.7 1335 199 1335 188.9 1335 . 7 187.l 1339 185.4 1340.6 185.7 1341.9 186.3 1343 199 1400 198.l 1500 195.8 1800 195.9 1900 196.5 2000 197.l 2300 197.3 2400 198.8 2500 198.4 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .025 1335 .02 1343 .025 Bank Sta: Left Right Coeff Contr. Expan. 1335 1343 Upstream Embankment side slope Downstream Embankment side slope .3 Maximum allowable submergence for weir flow Elevation at which weir flow begins Energy head used in spillway design Spillway height used in design . 3 1200 196.7 1335 199 1337.4 199 1341.9 199 1400 198 .1 1700 195.6 2000 197 .l 2300 198 .3 2600 200.1 Sta Elev Sta Elev 1239 198 .6 1300 198.8 1336 .1 186 1337.4 185.7 1342.3 187 .l 1343 188.9 1600 195 .4 1700 195 .6 2100 198 .4 2200 197.9 2600 200.l 4300 210 0 horiz. to 1.0 vertical 0 horiz. to 1.0 vertical .95 Weir crest shape Broad Crested Number of Culverts 1 Culvert Name Shape Rock Pra Circular Rise 8 Span Metal Pipe Cul vert conform to s l ope U.S. EG FHWA Chart # 2 -Corrugated FHWA Scale # 2 -Mitered to Solution Criteria = Highest Culvert Upstrm Dist Length 0 47 n Value .022 Entrance Loss Coef . 6 Exit Loss Coef 1 Upstream Elevation 186.3 Centerline Station 1339 Downstream Elevation = 185 .4 Centerline Station 1339 CULVERT OUTPUT Profile #PF 1 Cul vert ID : Rock Pra Culv Q (cfs) 0.84 Culv Vel In (ft/s) 0.02 # Barrels 1 Culv Vel Out (ft/s) 0.02 Q Barrel (cfs) 0.84 Culv Inv El Up (ft) 186.30 E.G. us . (ft) 205.13 Culv Inv El Dn (ft) 185.40 w.s. us. (ft ) 205 .11 Culv Frctn Ls (ft) 0.00 Delta EG (ft ) 0.00 Culv Ext Lss (ft) Delta ws (ft ) 0.00 Culv Ent Lss (ft) 0.00 E.G. I C (ft) 205.14 Q Weir (cfs) 14262.53 E.G. oc (ft) 205.13 Weir Sta Lft (ft) 1020.74 Culvert Control Outlet Weir Sta Rgt (ft) 3462.90 Culv WS In (ft) 194.30 Weir Submerg 1. 00 Culv ws Out (ft) 193.40 Weir Max Depth (ft) 9.73 Culv Nml Depth (ft) Weir Avg Depth (ft) 5 .56 Culv Crt Depth (ft) 0.22 Wr Flw Area (sq ft) 13578.56 Culv Ful Lngh (ft) 47 .00 Min Top Rd (ft) 195.40 Warning: During subcritical analysis, while trying to calculate culvert and weir flow, the program could not get a balance of energy within the specified tolerance and number of trials . The program used the solution with the minimum error. Warning: The weir over culvert is submerged. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect INPUT Description: Station Elevation Data Sta Elev Sta 1000 206 .l 1100 1335 199 1335 1339 185 .4 1340.6 1343 199 1800 195.9 2300 197.3 Manning's n Values Sta n Val 1000 .025 1400 1900 2400 Sta 1335 Bank Sta: Left 1335 Right 1343 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) w.s. Elev (ft) Cri t W. S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Al pha Frctn Loss (ft) c & E Loss (ft) RS: 13857 num= Elev 201.4 188 .9 185.7 198.1 196.5 198.8 num= n Val .02 30 Sta 1200 1335.7 1341. 9 1500 2000 2500 3 Sta 1343 Elev 196 . 7 187 .1 186.3 195.8 197.l 198 .4 n Val .025 Sta Elev Sta 1239 198.6 1300 1336 .1 186 1337.4 1342 . 3 187.l 1343 1600 195.4 1700 2100 198.4 2200 2600 200.1 4300 Lengths: Left Channel 1 1 Right 1 Coeff Contr. .3 Profile #PF 1 205.13 0.01 205.11 0.000024 12730.00 2439.63 0.92 19 .71 2609744.3 l. 00 185 .40 l. 00 0.00 0.00 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs ) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft ) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.025 l. 00 1652.36 1652.36 1448.66 313.98 0.88 5.26 296986.4 314.22 0.01 0.01 501.51 55.26 Elev 198.8 185.7 188.9 195.6 197.9 210 Expan. .3 Channel 0.020 l. 00 151.23 151.23 153.87 8.00 l. 02 18 .90 31544.3 32.15 0.01 0.01 106.68 6.08 Right OB 0 .025 l. 00 12045.24 12045.24 11127 .47 2117.65 0.92 5.69 2281213.5 2117.74 0.01 0.01 981. 38 117. 57 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections . CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 13856 INPUT Description: Station Elevation Data num= 30 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 206.l 1100 201 1200 196.7 1239 194.6 1300 194 1335 199 1335 188 .9 1335.7 187.l 1336.1 186 .3 1337.4 185.7 1339 185.4 1340.6 185.7 1341.9 186.3 1342. 3 187.l 1343 188.9 1343 199 1400 198.l 1500 191.8 1600 191 .4 1700 191.6 1800 191. 9 1900 192.5 2000 193 .l 2100 193 .4 2200 193.9 2300 194.3 2400 194.8 2500 194.4 2600 200.l 4300 210 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .06 1335 .05 1343 .06 Bank Sta: Left Right Lengths: Left Channel Right Coef f Contr. Expan. 1335 1343 100 976 100 . 3 . 3 Ineffective Flow num= 2 Sta L Sta R Elev Sta L Sta R Elev 1000 1335 190.5 1343 4300 195.4 CROSS SECTION OUTPUT Profile #PF 1 E .G. Elev (ft) 205.12 Element Left OB Channel Right OB Vel Head (ft) 0.01 Wt . n-Val . 0.060 0 .050 0.060 w.s. Elev (ft) 205.12 Reach Len. (ft) 100.00 976.00 100 .00 Crit W.S. (ft) 195.41 Flow Area (sq ft) 2123.24 151.01 16453.94 E.G. Slope (ft/ft) 0.000050 Area (sq ft) 2123 .24 151.01 16453.94 Q Total (cfs) 12730.00 Flow (cfs) 1324. 93 89. 46 11315. 61 Top Width (ft) 2442.06 Top Width (ft) 315.71 8.00 2118. 35 Vel Total (ft/s) 0.68 Avg. Vel. (ft/s) 0.62 0.59 0.69 Max Chl Dpth (ft) 19.72 Hydr. Depth (ft) 6.73 18.88 7.77 Conv. Total (cfs) 1797732 .4 Conv. (cfs) 187107.4 12633.6 1597991. 4 Length Wtd. (ft) 159.24 Wetted Per. (ft) 316.32 31.97 2118. 75 Min Ch El (ft) 185.40 Shear (lb/sq ft) 0.02 0.01 0 .02 Alpha 1. 00 Stream Power (lb/ft s) 0.01 0.01 0.02 Frctn Loss (ft) 0 .01 Cum Volume (acre-ft) 501.47 106.67 981.05 C & E Loss (ft) 0.00 Cum SA (acres) 55.26 6.08 11 7. 52 Warning: The parabolic search method fai l ed to converge on critical depth. The program will try the cross section slice/secant method to find critical depth. CROSS SECTION RIVER: Lick Creek Main REACH: Fema X-sect RS: 12880 INPUT Description: Station Elevation Data num= 24 Sta El ev Sta Elev Sta Elev Sta Elev Sta Elev 1000 203.6 1100 199.4 1200 199 1243 199.7 1300 198.5 1400 195.4 1500 193.6 1600 194.8 1700 195.4 1800 195.3 1900 194.5 1929 192.7 1940 184.9 1951 181.9 1962 183.5 1971 194.6 2000 195.9 2100 194.7 2200 195.5 2300 196 2400 197.3 2500 197.8 2600 197.9 4320 210 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .065 1900 .05 1971 .065 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1900 1971 1550 2065 1250 .1 . 3 CROSS SECTION OUTPUT Profile #PF 1 E.G. Elev (ft) 205.11 Element Left OB Channel Right OB Vel Head (ft) 0.01 Wt. n-Val. 0.065 0.050 0.065 w.s. Elev (ft) 205.10 Reach Len. (ft) 1550.00 2065.00 1250.00 Crit W.S. (ft) Flow Area (sq ft) 7501 .87 1142.56 9214.95 E .G. Slope (ft/ft) 0.000066 Area (sq ft) 7501.87 1142. 56 9214.95 Q Total (cfs) 12730.00 Flow (cfs) 5718. 77 1632.19 5379.04 Top Width (ft) 2623.88 Top Width (ft) 900.00 71. 00 1652 .88 Vel Total (ft/s) 0.71 Avg. Vel. (ft/s) 0.76 1. 43 0.58 Max Chl Dpth (ft) 23.20 Hydr. Depth (ft) 8.34 16.09 5.58 Conv. Total (cfs) 1567422.0 Conv. (cfs) 704141.9 200969.1 662311.0 Length Wtd . (ft) 1447.93 Wetted Per. (ft) 901.69 79.35 1652.96 Min Ch El (ft) 181.90 Shear (lb/sq ft) 0.03 0.06 0.02 Alpha 1.31 Stream Power (lb/ft s) 0.03 0.08 0.01 Frctn Loss (ft) 0.07 Cum Volume (acre-ft) 490.42 92.18 951.58 C & E Loss (ft) 0.00 Cum SA (acres) 53.86 5.19 113. 19 Warning: The cross-section end points had to be extended vertically for the computed water surface. CROSS SECTION REACH: Fema X-sect INPUT RIVER: Lick Creek Main RS: 10815 Description : Station Elevation Data Sta El ev 1000 204.5 1246 1491 1637 1778 1814 2023 2214 2388 2856 3408 3960 196.5 193 .3 193 .3 187.9 193 193.2 193.4 192 .2 197 .l 199.9 203.8 Manning's n Val ues Sta n Val 1000 . 07 Sta 1084 1253 1506 1675 1785 1840 2083 2232 2414 2966 3518 Sta 1759 Bank Sta: Left 1759 Right 1814 CROSS SECTION OUTPUT E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E.G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Mi n Ch El (ft) Al pha Frctn Loss (ft) C & E Loss (ft) num= Elev 200.8 196.4 193.4 193.5 183.8 193 . 9 193 .3 191.5 194.3 197 .9 200.9 num= n Val .065 56 Sta 1123 1337 1590 1737 1793 1862 2119 2252 2523 3077 3629 3 Sta 1814 Elev 200 194 .8 193 .2 193.6 182.1 193 .4 193.3 193.7 195 198.2 201.7 n Val .08 Sta 1169 1368 1608 1759 1803 1931 2193 2297 2635 3187 3739 Elev 198 .7 194.5 193.1 193 183 .5 192.8 193.8 194.2 194.8 198.6 202 .4 Sta 1205 1422 1620 1776 1804 1973 2206 2304 2745 3298 3850 Lengths: Left Channel Right 1250 Coeff Contr. .l 1550 2065 Profil e #PF 1 205.04 0.00 205.03 0.000040 12730.00 2960 .00 0 .52 22 .93 2001526.6 1373.40 182.10 1.14 0.03 0.00 Element Wt. n-Val . Reach Len. (ft) Flow Area (sq ft) Area (sq ft ) Flow (cfs ) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq f t) Str eam Power (l b/ft s) Cum Volume (acre-ft) Cum SA (acres) Left OB 0.070 1550 .00 6930.09 6930 .09 4084 .08 759 .00 0.59 9.13 642135 .9 759.89 0.02 0.01 233 .66 24.34 Elev 198.1 193.4 191. 6 188.1 183 .9 193 193.6 194 .2 195.6 199.3 203.1 Expan. .3 Channel 0 .065 2065.00 1000.72 1000.72 942.62 55.00 0.94 18.19 148206.6 60.69 0.04 0 .04 41 .38 2 .20 Right OB 0.080 1250.00 16648.19 16648.19 7703.31 2146.00 0. 46 7.76 1211184. 1 2147.63 0.02 0.01 580.50 58.68 Warning: The cross-section end points had to be extended vertically for the computed water sur face . Warning: The conveyance ratio (upstream conveyance di v i ded by downstream conveyance) is less than 0 .7 or greater than 1.4. This may i ndi cate the need for additional cross sections. CROSS SECTION REACH: Fema X-sect RIVER: Lick Creek Main RS: 8750 INPUT Description: Station Elevation Sta Elev 1000 205.4 1495 1626 1800 2053 2500 3000 3500 190 183.3 190.9 189.8 190.5 193.8 197 Data Sta 1100 1505 1634 1910 2100 2600 3100 3600 Manning's n Values Sta n Val Sta 1618 1000 . 07 Bank Sta: Left 1618 Right 1656 CROSS SECTION OUTPUT num= Elev 200.8 187.9 182.3 190.8 190.6 192.8 194.l 197.7 num= n Val .065 37 Sta 1200 1519 1643 2000 2200 2700 3200 3 Sta 1656 Elev 194.3 191. 2 183.6 190.4 190.5 193.4 195.3 n Val .08 Lengths: Left Channel 0 0 Profile #PF 1 Sta 1300 1600 1656 2019 2300 2800 3300 Ri ght 0 El ev 194.2 192.4 191.3 189.4 191 193 .3 195.9 Sta 1400 1618 1700 2035 2400 2900 3400 Coeff Contr . .1 Elev 192.l 191.5 191.l 185.5 189.9 193 .l 196.5 Expan. .3 E.G. Elev (ft) Vel Head (ft) W.S. Elev (ft) Crit W.S. (ft) E .G. Slope (ft/ft) Q Total (cfs) Top Width (ft) Vel Total (ft/s) Max Chl Dpth (ft) Conv. Total (cfs) Length Wtd. (ft) Min Ch El (ft) Alpha Frctn Loss (ft) c & E Loss (ft) 205.00 0.00 205.00 192 .62 0.000017 12730.00 2591.30 0.41 22.70 3073778.3 182.30 1. 02 SUMMARY OF MANNING'S N VALUES River:N.F. Lick Creek n7 Reach n8 N.F . Main N.F . Main N.F. Main N.F. Main N.F . Main N.F. Main N.F . Main N.F. Main N.F. Main N.F. Main N.F . Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main .014 N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F . Main N.F. Main N.F. Main N.F . Main N.F . Main N.F. Main N.F . Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F . Main N.F. Main N.F. Main N.F . Main N.F. Main N.F. Main N.F. Main .04 River Sta. n9 68770 68410 68025 67680 67300 67075 67060 67050 67049 66980 66970 66940 66850 66550 66300 66216 66215 .04 66150 66105 66090 66075 66037 66000 65980 65970 65969 65950 65700 65500 65250 65050 64800 64500 64395 64158 63920 63870 63770 63470 63220 62721 62720 61960 Element Wt. n-Val. Reach Len. (ft) Flow Area (sq ft ) Area (sq ft) Flow (cfs) Top Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) nl .075 .075 .075 .075 .075 .075 .075 .075 Culvert .075 .075 .075 .075 .075 .075 .06 .06 .06 .04 .04 .04 Culvert .04 .04 .065 .075 .075 .075 .075 .075 .075 .07 .06 .06 Culvert .06 .07 .07 .07 .07 .07 .07 .07 n2 .055 .055 .055 .055 .055 .055 .055 .055 .055 .055 .055 .055 .055 .055 .04 .06 .018 .014 .014 .014 .014 .014 .02 .04 .04 .055 .055 .055 .055 .OS .04 .04 .04 .055 .06 .065 .065 .065 .065 .065 n3 Left OB 0.070 6202.89 6202.89 2558.70 609.30 0.41 10.18 617821.1 610.29 0.01 0.00 .075 .075 .075 .075 .075 .075 .075 .075 .075 .075 .075 .075 .075 .06 .04 .04 .04 .04 .04 .04 .04 .014 .065 .075 .075 .075 .075 .075 .075 .07 .06 .06 .06 .07 .07 .075 .075 .075 .075 .075 n4 .014 Channel 0.065 745.00 745.00 467.06 38.00 0 .63 19.61 112775.8 43.72 0.02 0.01 nS .014 Right OB 0.080 23810.30 23810.30 9704.25 1944.00 0. 41 12.25 2343181.5 1952.36 0.01 0.01 n 6 .014 N.F. Main N.F. Main River:S.F. LICK CREEK Reach AlexBranch AlexBranch AlexBranch AlexBranch AlexBranch AlexBranch west field west field west field west field west field west field west field west field west field west field west field west field west field west field west field west field west field S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main 61200 59900 River Sta. 8867. 8845. 8766. 8744. 8536. 8277. 11228. 10978. 10758. 10628. 10518. 10338. 10208. 10138. 10058. 10018. 9688. 9568. 9458. 9343. 9088. 8750. 8354. 7993. 7815. 7612. 7435. 7137. 6825. 6784. 6762. 6730. 6698. 6675. 6632. 6612. 6423. 6266. 6175. 6050. 5943. 5827. 5616. 5320. 5200. 5050. 4930. 4810. 4580. 4310. 3860. 3665. 3610. 3596. 3567. 3538. 3520. 3467. 3410. 3200. 2880. 2560. 2540. nl .07 .07 .1 . l .1 .1 .1 .1 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 Culvert .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .025 .025 Culvert .025 .025 .08 .08 .08 .08 .08 .08 n2 .065 .065 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .04 .03 .014 .014 .014 .025 .03 .03 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .018 .018 .018 .018 .05 .05 .05 .05 .05 . 013 n3 .075 .07 .1 .1 .1 .l .1 .1 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .08 .025 .025 .025 .025 .08 .08 .08 .08 .08 .08 S.F. Main S.F. Main S.F. Main S.F. Main River:Lick Creek Main Reach Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema x-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect 2375. 2210. 2050. 1060 River Sta. 58600 57300 56000 54700 53400 52666 51932 51198 50464 49730 49120 48510 47900 46940 45980 45020 43850 42680 42584 42583 42540 42539 42440 41710 41088 40466 39844 39222 38600 38434 38268 38012 37936 37770 37604 37438 37272 37106 36940 36774 36608 36442 36276 36110 35944 35778 35612 35446 35280 34200 33586 32972 32358 31744 31130 30520 29910 29300 28690 28080 27210 Culvert .08 .08 .08 nl .07 .085 .085 .085 .07 .085 .085 .085 .085 .085 .085 .085 .06 .06 .06 .06 .075 .05 .015 Bridge .015 .05 .075 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .075 .075 .075 .075 .075 .075 .085 .085 .085 .085 .085 .085 n2 . 013 .05 .05 .065 .065 .065 .065 .065 .065 .065 .065 .065 .065 .065 .065 .055 .055 .055 .055 .06 .045 .02 .02 .045 .055 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 .07 n3 .08 .08 .08 .07 .085 .085 .085 .075 .085 .085 .085 .085 .085 .085 .085 .09 .09 .09 .09 .09 .05 .015 .015 .05 .075 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 .085 Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect 26340 24490 22640 20790 20185 19580 17930 16280 15780 15280 14780 14280 13905 13904 13880.5 13857 13856 12880 10815 8750 SUMMARY OF REACH LENGTHS River: N.F. Lick Creek Reach N.F. Main N.F. Main N.F. Main N.F . Main N.F. Main N.F. Main N.F . Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main River Sta. 68770 68410 68025 67680 67300 67075 67060 67050 67049 66980 66970 66940 66850 66550 66300 66216 66215 66150 66105 66090 66075 66037 66000 65980 65970 65969 65950 65700 65500 65250 65050 64800 64500 64395 64158 63920 63870 63770 63470 63220 62721 .08 .08 .07 .07 .07 .07 .07 .07 .065 .065 .065 .065 .06 .025 Culvert .025 .06 .065 .07 .07 .065 .065 .06 .06 .055 .055 .055 .055 .05 .05 .05 .05 .05 .02 .02 .05 .05 .065 .065 Left Channel 160 360 210 385 220 345 230 380 315 225 15 15 10 10 70 70 Culvert 10 10 20 70 100 90 150 300 280 250 84 84 1 1 65 65 90 45 30 15 40 15 75 75 Culvert 20 20 10 10 1 1 19 19 200 250 180 200 250 250 210 200 250 250 270 300 80 100 475 475 Culvert 90 50 100 100 300 300 250 250 499 499 1 1 .085 .085 .07 .07 .07 .07 .07 .07 .065 .065 .065 .065 .06 .025 .025 .06 .065 .08 .08 Right 400 235 240 300 65 15 10 70 10 40 25 300 220 84 1 5 5 5 5 75 20 10 1 19 300 220 250 1 90 230 330 120 475 30 90 250 250 499 1 N.F. Main N.F. Main N.F. Main N.F. Main 62720 61960 61200 59900 River: S.F. LICK CREEK Reach AlexBranch AlexBranch AlexBranch AlexBranch AlexBranch AlexBranch west field west field west field west field west field west field west field west field west field westfield west field westfield westf ield west field west field west field west field S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main River Sta. 8867. 8845. 8766. 8744. 8536. 8277. 11228. 10978. 10758. 10628. 10518. 10338. 10208. 10138. 10058. 10018. 9688. 9568. 9458. 9343. 9088. 8750. 8354. 7993. 7815. 7612. 7435. 7137. 6825. 6784. 6762. 6730. 6698. 6675. 6632. 6612. 6423. 6266. 6175. 6050. 5943. 5827. 5616. 5320. 5200. 5050. 4930. 4810. 4580. 4310. 3860. 3665. 3610. 3596. 3567. 3538. 3520. 3467. 3410. 3200. 2880. 650 650 1050 1050 760 760 1300 1300 Left Channel 22 22 65 79 20 22 150 208 190 259 0 0 250 215 200 220 155 130 80 110 150 180 140 130 50 70 60 80 40 40 200 330 80 120 120 110 80 115 270 256 345 338 380 396 0 0 120 178 90 203 135 177 200 298 121 121 41 41 24 24 64 64 Culvert 23 23 43 43 20 20 189 189 157 157 91 91 115 115 135 107 110 116 170 211 100 296 70 120 200 100 238 210 150 180 300 100 170 340 450 450 110 110 30 80 14 14 61 61 Culvert 18 18 50 50 57 57 210 210 330 330 350 350 575 575 1083.3 1083.3 Right 22 110 20 180 208 0 280 220 100 120 140 110 105 60 40 160 140 160 96 210 225 380 0 175 175 135 200 121 41 24 64 23 43 20 189 157 91 115 180 95 130 225 180 150 130 250 200 270 450 110 55 14 61 18 50 57 210 330 350 S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main 2560. 2540. 2375. 2210. 2050. 1060 River: Lick Creek Main Reach Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect River Sta. 58600 57300 56000 54700 53400 52666 51932 51198 50464 49730 49120 48510 47900 46940 45980 45020 43850 42680 42584 42583 42540 42539 42440 41710 41088 40466 39844 39222 38600 38434 38268 38012 37936 37770 37604 37438 37272 37106 36940 36774 36608 36442 36276 36110 35944 35778 35612 35446 35280 34200 33586 32972 32358 31744 31130 30520 29910 29300 28690 50 302 Culvert 160 810 0 50 302 160 890 0 Left Channel 1050 1300 1050 1300 1050 1300 1050 1300 460 734 460 734 460 734 460 734 460 734 266.7 610 266.7 610 266.7 610 783.3 960 783.3 960 783.3 960 Bridge 900 1170 900 1170 96 96 44 44 1 99 500 600 600 600 600 600 155 155 155 155 155 155 155 155 155 155 155 155 155 155 155 155 155 155 155 155 700 570 570 570 570 570 400 400 400 400 400 1 99 730 622 622 622 622 622 166 166 166 166 166 166 166 166 166 166 166 166 166 166 166 166 166 166 166 166 1080 614 614 614 614 614 610 610 610 610 610 50 302 160 700 0 Right 1083.3 1083 1083 1083 480 480 480 480 480 516 516.7 516.7 696.7 696.7 696 .7 750 730 96 44 1 99 900 560 560 560 560 560 92.5 92.5 92.5 92.5 92 .5 92.5 92.5 92 .5 92 .5 92.5 92.5 92.5 92.5 92.5 92.5 92.5 92.5 92.5 92.5 92.5 1050 520 520 520 520 520 540 540 540 540 540 Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect 28080 27210 26340 24490 22640 20790 20185 19580 17930 16280 15780 15280 14780 14280 13905 13904 13880.5 13857 13856 12880 10815 8750 825 825 1283.3 1283.3 1283.3 575 575 1650 1650 482.5 482.5 482 .5 482.5 300 1 47 Culvert 1 100 1550 1550 0 SUMMARY OF CONTRACTION AND EXPANSION COEFFICIENTS River: N.F. Lick Creek 870 870 1850 1850 1850 605 605 1650 1650 500 500 500 500 375 1 47 1 976 2065 2065 0 Reach River Sta. Contr. Expan. N.F . Main N.F . Main N.F . Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F . Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main 68770 68410 68025 67680 67300 67075 67060 67050 67049 66980 66970 66940 66850 66550 66300 66216 66215 66150 66105 66090 66075 66037 66000 65980 65970 65969 65950 65700 65500 65250 65050 64800 64500 64395 64158 63920 63870 63770 63470 .1 .1 .1 .1 .1 .3 .3 .3 Culvert .3 .3 .3 .1 .1 .1 .1 .1 .1 . 3 . 3 . 3 Culvert . 3 . 3 . 3 . 3 .3 .1 .1 .1 .1 .1 .3 .3 Culvert .3 .1 .1 .1 . 3 . 3 . 3 . 3 . 3 .5 .5 . 5 . 5 .5 .5 .3 .3 .3 .3 .3 .3 .5 .5 .5 .5 .5 .5 . 5 . 5 . 3 . 3 . 3 . 3 . 3 . 5 . 5 . 5 . 3 . 3 .3 515 515 1473.3 1473.3 1473.3 575 575 1300 1300 485 485 485 485 450 1 47 1 100 1250 1250 0 N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main N.F. Main 63220 62721 62720 61960 61200 59900 River: S.F. LICK CREEK Reach AlexBranch AlexBranch AlexBranch AlexBranch AlexBranch AlexBranch westf ield westfield westf ield westf ield westfield westfield westfield west field westf ield westf ield westf ield westfield west field west field westfield westfield westf ield S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main River Sta. 8867. 8845. 8766. 8744. 8536. 8277. 11228. 10978. 10758. 10628. 10518. 10338. 10208. 10138. 10058. 10018. 9688. 9568. 9458. 9343. 9088. 8750. 8354. 7993. 7815. 7612. 7435. 7137. 6825. 6784. 6762. 6730. 6698. 6675. 6632. 6612. 6423. 6266. 6175. 6050. 5943. 5827. 5616. 5320. 5200. 5050. 4930. 4810. 4580. 4310. 3860. 3665. 3610. 3596. 3567. 3538. 3520. 3467. 3410. .1 .1 .1 .1 .1 .1 Contr. .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .3 .3 Culvert .3 .3 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .3 .3 Culvert .3 .3 .1 .1 .3 .3 .3 .3 .3 .3 Expan. .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .5 .5 .5 .5 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .5 .5 .5 .5 .3 .3 S.F. Main S.F. Main S.F. Main S.F. Main S.F. Main S .F. Main S.F. Main S.F. Main 3200. 2880. 2560 . 2540 . 2375 . 2210. 2050. 1060 River: Lick Creek Main Reach Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect River Sta. 58600 57300 56000 54700 53400 52666 51932 51198 50464 49730 49120 48510 47900 46940 45980 45020 43850 42680 42584 42583 42540 42539 42440 41710 41088 40466 39844 39222 38600 38434 38268 38012 37936 37770 37604 37438 37272 37106 36940 36774 36608 36442 36276 36110 35944 35778 35612 35446 35280 34200 33586 32972 32358 31744 31130 30520 29910 .1 .1 . 3 .3 Culvert .3 .1 .1 Contr . Bridge .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 . 4 .4 .4 .4 .4 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 . 3 . 3 . 5 .5 .5 .3 .3 Expan. .3 .3 .3 .3 .3 .3 .3 .3 . 3 . 3 . 3 . 3 .3 .3 .3 .3 .3 .6 . 6 . 6 . 6 . 6 . 3 . 3 . 3 . 3 . 3 . 3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 . 3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect Fema X-sect 29300 .1 28690 .1 28080 .1 27210 .1 26340 .1 24490 .1 22640 .1 20790 .1 20185 .1 19580 .1 17930 .1 16280 .1 15780 .1 15280 .1 14780 .1 14280 .1 13905 .3 13904 .3 13880.5 Culvert 13857 .3 13856 .3 12880 .1 10815 .1 8750 .1 Profile Output Table -Standard Table 1 . 3 . 3 . 3 . 3 . 3 .3 .3 . 3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 .3 River Reach River Sta Q Total Min Ch El W.S. Elev Crit W.S. E .G. Elev E.G. Slope Vel Chnl (ft) (ft/ft) N.F . Lick Creek 272.38 0.000471 N.F. Lick Creek 273.09 0.000884 N.F. Lick Creek 274.29 0.005358 N.F. Lick Creek 276.75 0.002946 N.F. Lick Creek 276.79 0.003980 N.F. Lick Creek 278.81 0.004114 (ft/s) N.F. Main 2.14 N.F. Main 2.70 N.F. Main 5.31 N.F. Main 3.53 N.F. Main 4.86 N.F. Main 4.57 N.F. Lick Creek N.F. Main 281.04 0.015563 9.23 N.F. Lick Creek 282.38 0.002099 N.F. Lick Creek 282 .62 0.002595 N.F. Lick Creek 283.03 0.002245 N.F. Lick Creek N.F. Lick Creek 284.87 0.000774 N.F. Lick Creek 285.01 0.000958 N.F. Lick Creek 285.48 0.002453 N.F. Lick Creek 286.32 0.004396 N.F. Lick Creek 286.98 0.002384 N.F . Lick Creek 287.70 0.003156 N.F . Lick Creek 288.13 0.001516 N.F. Lick Creek 288.63 0.001880 N.F. Lick Creek N.F. Main 3.94 N.F. Main 4.69 N.F. Main 6.85 N.F. Main N.F. Main 4.30 N.F. Main 4.01 N.F. Main 5.21 N.F. Main 6.02 N.F. Main 4.61 N.F. Main 5.57 N.F. Main 3.61 N.F. Main 5.42 N.F. Main Flow Area Top Width Froude # Chl (cfs) (ft) (ft) (ft) (sq ft) 59900 2249.23 61200 1618.37 61960 895.08 62720 1227.35 62721 1003.03 63220 776.75 63470 525.17 63770 1152 . 80 63870 966.74 63920 336.09 64158 64395 460.80 64500 1166. 93 64800 776.31 65050 580. 71 65250 878.03 65500 746.00 65700 788.26 65950 802 .14 65969 (ft) 968.60 506 .06 479.53 574.44 598 .20 271 . 57 361.99 504 .69 398.99 382.23 413.57 478 .33 298.00 263.41 364.56 357.41 238.73 428.85 2301.00 2301.00 2301 .00 2301.00 2301.00 2301.00 2301.00 2301.00 2301.00 2301.00 Cul vert 1980.00 1980.00 1980.00 1980.00 1980.00 1980.00 1980.00 1980.00 1980.00 259.90 0.12 262.00 0.16 265.30 0.37 268.50 0.26 268.50 0.34 272 .40 0.34 272. 80 0.66 273 .20 0.26 273.30 0.32 273.40 0.42 274 .85 0.25 276.00 0.27 276.90 0.35 277.60 0.42 278.20 0.31 278 .90 0.36 279.50 0.25 280.00 0.38 280.10 272. 36 273 .05 274. 11 276.68 276.60 278 .62 280.32 282.27 282.45 282.30 284.58 284.90 285.26 285.92 286.81 287.41 287.97 288.31 288 .60 280.32 278.58 278.93 283 .52 288. 71 0.000391 N.F . Lick Creek 288.72 0.000109 N.F . Lick Creek 288.72 0.000065 N.F . Lick Creek 288.89 0.000250 N.F. Lick Creek N.F . Lick Creek 289 .28 0.000200 N.F. Lick Creek 289.34 0 .000084 N.F. Lick Creek 289.39 0.000119 N.F. Lick Creek 289.42 0.000347 N.F. Lick Creek 289.44 0.000166 N.F. Lick Creek 289.45 0 .001165 N.F. Lick Creek 289.59 0.002664 N.F. Lick Creek 290.23 0.002413 N.F. Lick Creek 291.00 0.002944 N.F. Lick Creek 291.16 0.002926 N.F. Lick Creek 291 .28 0.001912 2.89 N.F. Main 3.06 N.F. Main 3.25 N.F. Main 5.64 N.F. Main N.F. Main 5.15 N.F. Main 3 .66 N.F. Main 4.41 N.F. Main 4.86 N.F. Main 4.15 N.F. Main 3.89 N.F. Main 4 .01 N.F. Main 4.12 N.F. Main 5.57 N.F. Main 5.53 N.F. Main 4.11 N.F. Lick Creek N.F. Main 291.30 0.000991 3.34 N.F. Lick Creek N.F. Main N.F. Lick Creek N.F. Main 292.07 0.000326 2.17 N.F. Lick Creek 292 .09 0.001027 N.F. Lick Creek 292 .10 0.001068 N.F. Lick Creek 292.42 0.002323 N.F. Lick Creek 293 .14 0.002376 N.F. Lick Creek 293 .75 0.002015 N.F. Lick Creek 294.30 0.001449 N.F. Lick Creek 294.75 0.001179 S.F. LICK CREEK 272.53 0.000648 S .F. LICK CREEK 273.10 0.000698 S.F. LICK CREEK 273.39 0.000216 S.F. LICK CREEK S .F. LICK CREEK 274.26 0. 000132 S.F. LICK CREEK 274.37 0.000739 S.F. LICK CREEK 274.78 0.001991 S.F. LICK CREEK 275.59 0.002562 S.F. LICK CREEK 276.06 0 .001817 S .F. LICK CREEK 276.15 0.001185 S.F. LICK CREEK 276.26 0 .000272 N.F. Main 3.34 N.F. Main 3.33 N.F. Main 5 .35 N.F. Main 5.01 N.F. Main 4. 04 N.F. Main 2.98 N.F. Main 2.81 S.F. Main 3 .06 S.F. Main 3.35 S .F. Main 6.04 S.F. Main S.F. Main 4.89 S.F. Main 3.18 S.F. Main 4 .56 S.F. Main 5.41 S.F. Main 4 .29 S.F. Main 3 .51 S.F. Main 5.65 S.F. LICK CREEK S.F. Main 1142.58 65970 1137.34 65980 1059.69 66000 615.31 66037 66075 782. 77 66090 872. 77 66105 647.46 66150 488.12 66215 638.15 66216 649.35 66300 703.89 66550 658.64 66850 845.20 66940 832 .27 66970 990.00 66980 1285.73 67049 67050 1860.40 67060 1434 .53 67075 1439.07 67300 848.63 67680 888.47 68025 878 .90 68410 974.08 68770 1101.84 1060 1338.30 2050. 1524.35 2210 . 380.14 2375. 2540. 414.42 2560. 1574 .30 2880. 1098.75 3200. 693.67 3410. 1051.10 3467. 995.65 3520. 686.08 3538. 542.12 1980 .00 538.34 1980 .00 541.15 1980 .00 477.40 466.08 289.02 Culvert 1980 .00 1980.00 1980.00 193.27 1980 .00 167.28 236.20 239.89 298.60 390.61 342.94 307.82 368.06 621.15 808.12 803.87 809.00 1980 .00 1980.00 1980.00 1980.00 1980 .00 1980.00 1980.00 1980.00 Culvert 1980.00 1980.00 1980.00 1980.00 291. 33 1980.00 329.06 1980.00 332.76 1980.00 336.32 424.07 353.43 513.69 32.00 32.00 1980.00 2297.00 2297.00 2297 .00 Culvert 2025.00 2025.00 552.03 2025.00 413.25 2025.00 275.26 2025 .00 339.87 2025.00 311.39 2025.00 218.98 2025.00 0.18 280.10 0.19 280.13 0.20 280.20 0.35 280.50 0.31 280.60 0.23 280.80 0.28 281.00 0.36 281.40 0.32 281.40 0.29 282.00 0.32 282.50 0.31 282.50 0.36 283.00 0.36 282.50 0.28 280.34 0 .20 280.70 0.12 282.50 0.21 282.50 0.21 283.80 0.33 285 .00 0.32 287.00 0.29 288 .50 0.24 288.80 0.22 261. 00 0.19 262.65 0 .19 260.94 0.31 260 .94 0.24 263.78 0 .19 264.95 0.27 265.63 0 .34 266 .68 0.27 267.03 0.24 267.36 0.34 267.48 288.59 288.59 288 .43 288.92 289.15 289.10 289.06 289.19 289.23 289.40 290.01 290.81 290 .99 291 .17 291.21 292.02 292.01 292.03 292.24 292 .99 293.60 294 .20 294.66 272.43 272 . 99 272.82 273.89 274 .30 274.67 275.26 275.96 276.02 275.96 275.64 283.52 283.56 284.45 284.73 284.25 284.94 289 .60 290 .20 266 .35 265 .93 272. 51 276.60 0.000852 S.F. LICK CREEK S.F. LICK CREEK 277.41 0.000174 S.F. LICK CREEK 277.43 0.000091 S.F. LICK CREEK 277.47 0.002401 S.F. LICK CREEK 277 .80 0 .003021 S.F. LICK CREEK 279 .43 0 .004316 7.88 S .F . Main S.F . Main 3.99 S.F. Main 3.50 S.F. Main 4.90 S.F. Main 5.75 S .F. Main 6.09 S.F. LICK CREEK S.F. Main 280.14 0.002382 4.67 S.F . LICK CREEK S.F. Main 280.45 0 .001007 S.F. LICK CREEK 280.70 0. 001181 S.F. LICK CREEK 281.19 0. 007249 S.F. LICK CREEK 281. 71 0.002132 S.F. LICK CREEK 281.91 0.001700 S.F. LICK CREEK 282.30 0.001687 S.F. LICK CREEK 282.78 0.003171 S.F. LICK CREEK 283.10 0.002535 S.F. LICK CREEK 283.51 0.003920 S.F. LICK CREEK 283. 71 0.000778 S.F . LICK CREEK 283.78 0.000621 3.23 S.F. Main 3.29 S .F. Main 7.05 S .F. Main 4.38 S .F. Main 3.35 S .F. Main 3.91 S.F. Main 5.66 S .F. Main 5.30 S .F . Main 5.36 S.F. Main 2.77 S.F. Main 2.33 S .F. LICK CREEK S.F. Main 283 .97 0.002088 S .F. LICK CREEK 284.35 0.001612 S .F. LICK CREEK 284.38 0.001231 S .F. LICK CREEK 285.28 0.003380 S.F. LICK CREEK 286.87 0.002686 4.06 S.F. Main 5.47 S.F. Main 5.13 S.F. Main 11.09 S.F. Main 14.09 S.F. LICK CREEK S.F. Main S .F . LICK CREEK S .F. Main 287.22 0.000293 5 .76 S.F. LICK CREEK 287.31 0.000065 S.F. LICK CREEK 287.32 0.000174 S.F. LICK CREEK 287.35 0.000238 S.F. LICK CREEK 287.45 0.000665 S.F. LICK CREEK 287.57 0.001005 S.F. LICK CREEK 287.70 0.000923 S.F. LICK CREEK 287.81 0.000667 S.F. LICK CREEK 287.98 0.000520 S.F. LICK CREEK 288.36 0.001859 S.F. LICK CREEK 288.75 0.000955 S.F. LICK CREEK 289.01 0.001049 S.F. Main 3. 71 S.F. Main 2.21 S .F. Main 1.70 S.F. Main 2.23 S.F. Main 3.10 S.F. Main 2.13 S .F. Main 2.17 westfield 1.94 west field 4 .27 west field 2.91 west field 2.44 256.94 3567. 3596. 919.58 3610. 1193. 27 3665. 892.19 3860. 768.44 4310. 836.87 4580. 1026.12 4810. 1351.02 4930. 1033.21 5050. 657.16 5200. 761.81 5320. 934.01 5616. 1026.85 5827. 656.09 5943. 703.64 6050. 554.74 6175. 1181.74 6266. 1069.52 6423. 804.72 6612. 956.29 6632. 1005.74 6675. 182.60 6698. 143 .69 6730. 6762. 639.85 6784. 1258.28 6825 . 11 72 . 03 7137. 986.49 7435. 1122. 81 7612. 1010.75 7815. 1194.56 7993. 1256.33 8354. 877.20 8750. 685.54 9088. 819.47 9343. 653.85 230.75 315.37 295.04 282.64 300.97 357.81 Cul vert 2025.00 2025.00 2025.00 2025 .00 2025.00 2025.00 395.68 2025 .00 406.48 2025.00 364.15 2025.00 286.37 2025.00 256.40 2025.00 291. 93 2025.00 366.72 2025.00 281.14 2025.00 236.66 2025.00 276.07 2025.00 406.38 2025.00 357.67 2025.00 328.51 2025.00 457.95 2025.00 459.58 178.31 23.28 440 .02 2025.00 2025.00 Culvert 1352.00 1352.00 461.46 1352.00 449.95 1352.00 375.19 1352.00 388.18 1352.00 379.06 1352.00 486.81 1352.00 457.46 1352.00 314.43 1352.00 270.00 1352. 00 262.01 1352. 00 218.28 0.49 267.60 0.23 267.97 0 .20 268.70 0. 30 268.93 0.38 271.28 0.43 271.50 0 .30 271.81 0.21 273.64 0.24 273.37 0.48 273.00 0 .32 275.00 0.28 275.00 0.28 275.00 0.40 275.00 0.36 276.50 0.43 277.00 0 .20 277.00 0.17 277.00 0.31 278.00 0.45 277.00 0.40 277 .50 0 .81 277.50 1. 00 277.68 0.34 277.72 0.21 278.00 0.15 279.00 0.13 279.90 0 .17 281.00 0.22 281.00 0.20 281.00 0.17 281.00 0 .16 281.00 0.30 282 .00 0.22 283 .00 0.21 277 .25 272.63 277.35 273.08 277.32 277.52 279.25 280.02 280.40 280.58 280 .93 281.51 281.80 282.19 282.42 282.81 283.12 283.63 283.70 283.78 284.06 284. 11 283.37 282.59 283.79 283.79 286.75 282.45 287 .13 281.58 287.26 287.31 287 .41 287.51 287.67 287.78 287.93 288.21 288.67 288.92 S.F. LICK CREEK 289.20 0.002369 S.F. LICK CREEK 289.71 0.006054 S.F. LICK CREEK 290.36 0.004631 S .F. LICK CREEK 291.34 0.002883 S.F. LICK CREEK 292.03 0. 011320 S.F. LICK CREEK 292.29 0.000812 S.F. LICK CREEK 292.71 0.011614 S.F. LICK CREEK 293 .58 0 .003803 S.F. LICK CREEK 294.14 0. 002915 S.F. LICK CREEK 2 94. 3 9 0.001822 S.F. LICK CREEK 294.86 0 .006043 S.F. LICK CREEK 296.44 0.008578 S.F. LICK CREEK 297.79 0.004330 S.F. LICK CREEK 287.96 0.000098 S.F. LICK CREEK 288.00 0.000339 S.F. LICK CREEK 288.15 0.001698 S.F. LICK CREEK 288.19 0.001615 S.F. LICK CREEK 288.50 0 .008394 S.F. LICK CREEK 288 .67 0.006532 Lick Creek Main 205.00 0.000017 Lick Creek Main 205.04 0.000040 Lick Creek Main 205.11 0.000066 Lick Creek Main 205.12 0.000050 Lick Creek Main 205.13 0.000024 Lick Creek Main Lick Creek Main 205.13 0.000024 Lick Creek Main 205.13 0.000050 Lick Creek Main 205.14 0.000029 Lick Creek Main 205.16 0.000044 Lick Creek Main 205.19 0.000069 Lick Creek Main 205.23 0.000096 Lick Creek Main 205.29 0.000158 Lick Creek Main 205.59 0.000265 Lick Creek Main 206 .14 0.000507 Lick Creek Main 206.66 0.001731 Lick Creek Main 207.77 0.002071 westfield 3.91 westfield 6.47 westfield 6.21 westfiel d 4. 94 westfield 10.34 westf ield 2.58 westfield 9.37 westfield 5.70 westfield 5.32 westfield 3.97 westf ield 5.77 westf ield 5.52 westf ield 5.32 AlexBranch 0.77 AlexBranch 1.11 AlexBranch 2.27 AlexBranch 2.23 AlexBranch 4.31 AlexBranch 3.86 Fema X-sect 0.63 Fema X-sect 0.94 Fema X-sect 1.43 Fema X-sect 0.59 Fema X-sect 1. 02 Fema X-sect Fema X-sect 1 .21 Fema X-sect 0.59 Fema X-sect 1.07 Fema X-sect 1.26 Fema X-sect 1. 49 Fema X-sect 1 .60 Fema X-sect 1. 68 Fema X-sect 2.00 Fema X-sect 2.44 Fema X-sect 4.57 Fema X-sect 4 .87 9458. 509.34 9568. 304.12 9688. 358.90 10018. 583.74 10058. 254.96 10138. 645.43 10208. 241 .62 10338. 462.37 10518. 470.83 10628. 516.48 10758. 317.14 10978. 244.82 11228. 482.16 8277. 433.04 8536. 272.60 8744. 128.83 8766. 130.96 8845. 67.96 8867. 76.77 8750 30758.19 10815 24579.00 12880 17859.37 13856 18728.19 13857 13848.83 13880.5 13904 13841 .42 13905 18754. 11 14280 24631.08 14780 21506.61 15280 18581. 71 15780 16394.63 16280 14157.12 17930 12891.61 19580 10927.96 20185 6663.52 20790 6004.49 1352.00 171.13 1352.00 119. 61 1352 . 00 119. 24 1352 .00 283.49 1352. 00 122.46 1352.00 197.03 1352.00 105.94 1352.00 211.47 1352.00 181.11 1352.00 168 .46 1352.00 146.53 1352.00 84.34 1352.00 221.19 292.00 128.81 292.00 104.80 292.00 53.69 292 .00 55.64 292 .00 35.82 292 .00 42.04 12730.00 2591.30 12730.00 2960.00 12730.00 2623.88 12730.00 2442.06 12730.00 2439.63 Culvert 12730.00 2439.59 12730.00 2441.13 12730.00 3123.28 12730.00 3049.19 12730.00 2889.88 12730.00 2656.94 12730.00 2405.63 12730.00 2794.31 12730.00 3010.70 12730.00 2395.85 12730.00 2254.09 283.00 0.33 284.00 0.52 284.00 0.46 284.00 0.36 284.00 0.72 286.00 0.20 286 .00 0 . 72 286.00 0.41 286.00 0.37 288.00 0.29 288.00 0.51 290.00 0.57 292.00 0.44 281.00 0 .07 281.90 0 .11 283.00 0 .25 283.00 0.24 285.00 0.53 285.00 0.47 182.30 0.02 182.10 0.04 181.90 0.06 185 .40 0.02 185.40 0.04 186.30 0.08 185 .40 0.02 185.00 0.04 186.10 0.06 187 .10 0.07 188 .10 0 .08 189.20 0.08 192.20 0 .11 195.10 0.15 194.00 0 .27 192.90 0.27 289.03 289.18 289.95 291.12 290.87 292.20 291.70 293.25 293.85 294.21 294.41 295.96 297.53 287.95 287.98 288.07 288. 11 288.21 288.44 205.00 205.03 205.10 205.12 205.11 205. 11 205.12 205.14 205.15 205.18 205.22 205.27 205.58 206.12 206.56 207.64 290.87 192.62 195.41 198.43 195 .41 206 .37 Lick Creek Main 210.23 0.001349 Lick Creek Main 212.38 0.001510 Lick Creek Main 214.48 0.001260 Lick Creek Main 215.39 0.001394 Lick Creek Main 216.10 0.000713 Lick Creek Main 216.59 0.001627 Lick Creek Main 217 .57 0.002508 Lick Creek Main 218 .89 0 .002744 Lick Creek Main 220 .01 0 .001606 Lick Creek Main 220.92 0.001892 Lick Creek Main 222 .41 0.003618 Lick Creek Main 224.06 0 .002362 Lick Creek Main 225.30 0.002048 Lick Creek Main 226.42 0.001940 Lick Creek Main 227.43 0.001674 Lick Creek Main 227 .98 0.000273 Lick Creek Main 228.02 0.000326 Lick Creek Main 228.08 0.000389 Lick Creek Main 228 .14 0 .000475 Lick Creek Main 228 .22 0.000577 Lick Creek Main 228.31 0.000700 Lick Creek Main 228.42 0.000855 Lick Creek Main 228 .56 0 .001040 Lick Creek Main 228.72 0.001231 Lick Creek Main 228.91 0.001542 Lick Creek Main 229 .14 0 .001819 Lick Creek Main 229.42 0 .002190 Lick Creek Main 229 .74 0 .002553 Lick Creek Main 230 .09 0 .002611 Lick Creek Main 230 .44 0.002876 Lick Creek Main 230.82 0.002969 Lick Creek Main 231 .19 0.003045 Lick Creek Main 231.57 0.003141 Lick Creek Main 231.94 0 .003116 Lick Creek Main 232 .31 0 .003122 Lick Creek Main Fema X-sect 4 .07 Fema X-sect 3.99 Fema X-sect 3.65 Fema X-sect 3.54 Fema X-sect 2.51 Fema X-sect 3. 71 Fema X-sect 4.66 Fema X-sect 5 .14 Fema X-sect 4.00 Fema X-sect 4.41 Fema X-sect 6 .18 Fema X-sect 5 .12 Fema X-sect 4.71 Fema X-sect 4.26 Fema X-sect 4.13 Fema X-sect 2.29 Fema X-sect 2 .44 Fema X-sect 2.59 Fema X-sect 2 .78 Fema X-sect 2.99 Fema X-sect 3.20 Fema X-sect 3.43 Fema X-sect 3.68 Fema X-sect 3.88 Fema X-sect 4.22 Fema X-sect 4.47 Fema X-sect 4.77 Fema X-sect 5.04 Fema X-sect 4.96 Fema X-sect 5 .09 Fema X-sect 5.06 Fema X-sect 4.99 Fema X-sect 4 .93 Fema X-sect 4.78 Fema X-sect 4 .62 Fema X-sect 22640 7062.88 24490 7467 .44 26340 7882.73 27210 7813 .24 28080 9979.92 28690 7241.30 29300 5910.57 29910 5352.08 30520 4891.33 31130 4547.82 31744 2833.31 32358 3030.22 32972 3174.67 33586 3278.27 34200 3425.07 35280 6728 . 20 35446 6410 .37 35612 6077.67 35778 5720 .82 35944 5396 .82 36110 5083.61 36276 4794.36 36442 4515 .61 36608 4317.41 36774 4042.82 36940 3885 .82 37106 3721.26 37272 3590.04 37438 3692.45 37604 3676 .69 37770 3713.41 37936 3773 .07 38012 3890.09 38268 3918.34 38434 3991 .40 38600 12741.00 2363.45 12741.00 2330 .12 12741.00 2306.43 12741.00 2250.02 12741.00 2370.69 12741.00 2032 .86 12741.00 1741.66 12741 .00 1503.31 9161. 00 1347.49 9161.00 1209.39 9161 .00 851. 83 9161. 00 579.60 9161 .00 558.24 9161.00 551.66 9161.00 549.29 9161.00 951.37 9161.00 973.88 9161.00 978.86 9161.00 981.57 9161.00 982.75 9161 .00 982.01 9161.00 988.13 9161.00 987.38 9161 .00 988.15 9161.00 1005.29 9161 .00 1024.52 9161 .00 1053.83 9161.00 1077.55 9161.00 1115. 01 9161.00 1165.66 9161.00 1176.63 9161.00 1206.06 9161.00 1289.66 9161.00 1257.63 9161.00 1281 .21 9161.00 195 .00 0 .22 1 97.00 0 .22 1 99.10 0.20 200.00 0.20 200.90 0 .14 202.00 0.21 203.00 0 .26 204.10 0.27 205.10 0.21 206.20 0.23 207.10 0.32 208.10 0.26 209.00 0.24 210.00 0.23 210. 90 0.21 207.00 0.10 207.70 0.10 208.40 0 .11 209.00 0.12 209.70 0.14 210.40 0.15 211.10 0.16 211. 80 0.18 212.40 0 .19 213.10 0 .22 213 . 80 0.23 214 .50 0.25 215.20 0.27 215.80 0 .27 216.50 0 .28 217.20 0.29 217.90 0 .29 218.60 0 .29 219.20 0 .28 219.90 0.28 220.60 210.14 212.29 214.40 21 5.32 216.07 216.53 217 .45 218 .74 219.92 220.83 222 .11 223.86 225.13 226.28 227.30 227.93 227.96 228.01 228.06 228.13 228.21 228.31 228.43 228.58 228.75 228.97 229.22 229.52 229.89 230.24 230.63 231.02 231.41 231.80 232.18 232.55 232.66 0 .003146 Lick Creek Main 234.30 0.002564 Lick Creek Main 235.75 0.002428 Lick Creek Main 237.14 0.002287 Lick Creek Main 238.48 0.002242 Lick Creek Main 239.80 0.002201 Lick Creek Main 242.83 0.006326 Lick Creek Main 243.33 0.003808 Lick Creek Main 243.33 0.000740 Lick Creek Main Lick Creek Main 243.58 0.000691 Lick Creek Main 244.01 0.000108 Lick Creek Main 244.26 0.000947 Lick Creek Main 245.06 0.000666 Lick Creek Main 246.55 0 .006454 Lick Creek Main 249.51 0.002108 Lick Creek Main 250.72 0.001110 Lick Creek Main 251.51 0.002241 Lick Creek Main 252.73 0.002877 Lick Creek Main 253.81 0.002242 Lick Creek Main 255.39 0.004138 Lick Creek Main 257.56 0.003899 Lick Creek Main 259.58 0.003488 Lick Creek Main 261.51 0.003488 Lick Creek Main 263.28 0.002927 Lick Creek Main 265.84 0.001789 Lick Creek Main 267.78 0.001669 Lick Creek Main 269 .59 0.001555 Lick Creek Main 271.20 0.001351 4.48 Fema X-sect 4.34 Fema X-sect 4.39 Fema X-sect 4.40 Fema X-sect 4.44 Fema X-sect 4.45 Fema X-sect 8.61 Fema X-sect 8.43 Fema X-sect 8.37 Fema X-sect Fema X-sect 8.17 Fema X-sect 1.63 Fema X-sect 3.41 Fema X-sect 2.89 Fema X-sect 8.52 Fema X-sect 5.53 Fema X-sect 3.92 Fema X-sect 4.66 Fema X-sect 5.03 Fema X-sect 4.27 Fema X-sect 5.83 Fema X-sect 5.92 Fema X-sect 5.78 Fema X-sect 5.87 Fema X-sect 5.44 Fema X-sect 4.45 Fema X-sect 4.30 Fema X-sect 4 .14 Fema X-sect 3.81 ERRORS WARNINGS AND NOTES 4058.20 39222 4412.61 39844 4606.05 40466 4812.62 41088 5043.98 41710 5345.18 42440 1064.46 42539 1087.01 42540 1094.75 42583 42584 1121.21 42680 8886 .83 43850 5070.79 45020 3461.23 45980 1046.38 46940 1908 .19 47900 2995.67 48510 2376.73 49120 2192.92 49730 2956.32 50464 2216.73 51198 2228.31 51932 2173.40 52666 2110.08 53400 1993.23 54700 2741.37 56000 2875 .72 57300 2913.04 58600 2808.50 1308. 58 9161.00 1412.60 9161.00 1539.62 9161.00 1678.55 9161. 00 1885.62 9161 .00 2185.76 9161.00 1386 .11 9161.00 125.48 9161.00 125. 82 131.96 Bridge 9161.00 9161 .00 1684.42 9161 .00 1211 .42 5324 .00 1030.94 5324.00 323.21 5324.00 481.23 5324.00 691.78 5324.00 643.93 5324.00 630.66 5324.00 1041.43 5324.00 881.10 5324.00 855.18 4905.00 892.00 4905 .00 839.22 4905.00 797.36 4905.00 939.08 4905 .00 1003.60 4905.00 949.85 4905.00 1005.91 Errors Warnings and Notes for Plan : Lick Cr 2000 RS: 67300 0.28 221. 70 0.26 222.90 0.25 224.00 0 .25 225.20 0 .25 226.30 0.25 228.00 0 .53 229.20 0 .50 229.20 0.50 229.20 0.48 228.00 0.09 229 .80 0.19 231 .60 0.16 233.70 0 .51 235.90 0.31 238.00 0.22 239.60 0.27 241.10 0.29 242.70 0 .25 244.10 0 .34 245.50 0.33 246.80 0.32 248.20 0.31 249.60 0.29 251.70 0.23 253.70 0.22 255.80 0.22 257.90 0.20 Profile: PF 1 234.20 235.65 237.03 238.37 239.70 241.68 238 .85 242.22 238.50 242.24 238.57 242.54 238.56 243.99 244.18 245.01 245.84 249.26 250.63 251 .37 252 .57 253. 72 255.21 257.37 259.38 261. 30 263.09 265 .73 267.68 269.50 271.12 River: N.F. Lick Creek Reach: N.F. Main Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. conveyance divided by downstream conveyance) is less This may indicate the need for River: N.F. Lick Creek Reach: N.F. Main additional cross sections. RS: 67060 Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. RS: 67050 Profile: PF 1 River: N.F. Lick Creek Reach : N.F. Main Warning:The parabolic search method try the cross section failed to converge on critical depth. The program will slice/secant method to find River: N.F . Lick Creek Reach: N.F. Main critical depth. RS : 66980 Profile: PF 1 Warning:Multiple water surfaces were found that could balance the energy equation. The program selected the water surface whose main channel velocity head was the closest to the previously computed cross section. River: N.F. Lick Creek Reach: N.F. Main Warning:The conveyance ratio (upstream than 0 .7 or greater than 1.4. This may indicate the need for River: N.F. Lick Creek Reach: N.F. Main Warning:The conveyance ratio (upstream than 0.7 or greater than 1 .4. This may indicate the need for River: N.F . Lick Creek Reach: N.F. Main Warning:The conveyance ratio {upstream than 0.7 or greater than 1 .4. This may indicate the need for River: N.F. Lick Creek Reach: N.F. Main Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: N.F. Lick Creek Reach: N.F. Main Warning:The conveyance ratio {upstream than 0.7 or greater than 1.4. This may indicate the need for River : N.F. Lick Creek Reach: N.F. Main RS: 66300 Profile: PF 1 conveyance divided by downstream conveyance) is less additional cross sections. RS: 66216 Profile: PF 1 conveyance divided by downstream conveyance) is less additional cross sections. RS: 66215 Profile: PF 1 conveyance divided by downstream conveyance) is less additional cross sections. RS: 66150 Profile: PF 1 conveyance divided by downstream conveyance) is less additional cross sections. RS: 66090 Profile: PF 1 conveyance divided by downstream conveyance) is less additional cross sections. RS: 66000 Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1 .4. This may indicate the need for River: N.F . Lick Creek Reach: N.F. Main Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: N.F. Lick Creek Reach: N.F. Main Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. additional cross sections. RS: 65970 Profile: PF 1 conveyance divided by downstream additional cross sections. RS: 65969 Profile: PF 1 conveyance divided by downstream additional cross sections. RS: 65700 Profile: PF 1 conveyance) is less conveyance) is less This may indicate the need for River: N.F. Lick Creek Reach: N.F. Main Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 o r greater than 1.4 . This may indicate the need for River: N.F. Lick Creek Reach: N.F. Main additional cross sections. RS: 64800 Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4 . This may indicate the need for additional cross sections . River: N.F. Lick Creek Reach: N.F. Main RS: 63920 Profile: PF 1 Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. River: N.F . Lick Creek Reach: N.F. Main RS: 63770 Profile: PF 1 Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need f or additional cross sections. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections . River: N.F. Lick Creek Reach: N.F. Main RS: 63470 Profile: PF 1 Warning:The energy equation could not be balanced within the specified number of iterations. The program selected the water surface that had the least amount of error between computed and assumed values. Warning:The velocity head has changed by more than 0 .5 ft (0.15 m). This may indicate the need for additional cross sections. warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections . Warning:The energy l oss was greater than 1 .0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. River: N.F. Lick Creek Reach: N.F. Main RS: 63220 Profile: PF 1 Warning:The energy loss was greater than 1 .0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: N.F. Lick Creek Reach: N.F. Main RS: 62720 Profile: PF 1 Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: N.F . Lick Creek Reach: N.F. Main RS: 61960 Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: N.F. Lick Creek Reach: N.F. Main RS: 59900 Profil e: PF 1 Warning:Divided flow computed for this cross-section . Warning:The energy loss was greater than 1 .0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: S.F. LICK CREEK Reach: AlexBranch RS: 8845. Profile: PF 1 Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: S.F. LICK CREEK Reach: AlexBranch Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: S .F. LICK CREEK Reach: AlexBranch Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: S .F. LICK CREEK Reach: AlexBranch Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: S.F. LICK CREEK Reach: westfield conveyance divided by downstream additional cross sections. RS: 8744. Profile: PF 1 conveyance divided by downstream additional cross sections. RS: 8536. Profile: PF 1 conveyance divided by downstream additional cross sections. RS: 8277. Profile: PF 1 conveyance divided by downstream additional cross sections. RS: 11228. Profile: PF 1 conveyance) is less conveyance) is less conveyance) is less conveyance ) is less Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section . This may indicate the need for additional cross sections. River: S.F. LICK CREEK Reach: westfield RS: 10978 . Profile: PF 1 Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Ri ver: S.F. LICK CREEK Reach: westfield RS: 10758. Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indi cate the need for additional cross sections. River: S.F. LICK CREEK Reach: westfield RS: 10338. Profile: PF 1 Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. River: S .F. LICK CREEK Reach: westfield RS: 10208. Profile: PF 1 Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. River : S.F. LICK CREEK Reach: westfield RS: 10138. Profile: PF 1 Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning:The conveyance ratio (upstream than 0.7 or greater than 1 .4. conveyance divided by downstream conveyance) is less This may indicate the need for River: S.F. LICK CREEK Reach: westfield additional cross sections. RS: 10058. Profile: PF 1 Warning:The energy equation could not be balanced within the specified number of iterations. The program selected the water surface that had the least amount of error between computed and assumed values. Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections . Warning:The conveyance ratio (upstream conveyance divided by downstream conv eyanc e ) is less than 0.7 or greater than 1 .4 . This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. River: S.F. LICK CREEK Reach: westfield RS: 9568. Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conv eyance) is less than 0 .7 or greater than 1.4. This may indicate the need for River: S.F. LICK CREEK Reach: westfield Warning:The conveyance ratio (upstream than 0 .7 or greater than 1 .4 . This may indicate the need for River : S .F. LICK CREEK Reach: westfield Warning:The conveyance ratio (upstream than 0.7 or greater than 1 .4 . additional cross sections. RS : 9458. Profile : PF 1 conveyance divided by downstream additional cross sections. RS: 8750 . Profile: PF 1 conveyance divided by downstream additional cross sections. RS: 7435 . Profile: PF 1 conv eyance) is less conveyance) is less This may indicate the need for River: S.F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. additional cross sections. RS: 6825 . Profile: PF 1 This may indicate the need for River: S.F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4 . additional cross sections. RS: 6784. Profile: PF 1 This may indicate the need for River: S.F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1 .4. This may indicate the need for River: S .F. LICK CREEK Reach : S.F. Main additional cross sections. RS: 6698. Profile : PF 1 Warning :The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning:The energy l oss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, energy was used. River: S.F. LICK CREEK Reach: S.F. Main RS: 6675 . Profile: PF 1 Warning:The velocity head has changed by more than 0 .5 ft (0.15 m). This may indicate the need for additional cross sections. Warning:The c onveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: S.F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: S .F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream conveyance additional RS: 6423. conveyance additional RS: 6175. conveyance divided by downstream conveyanc e) is less cross sections. Profile: PF 1 divided by downstream conveyance) is less cross sections. Profile: PF 1 divided by downstream conveyance) is less than 0.7 or greater than 1 .4. This may ind icate the need for River: S.F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream than 0.7 or greater than 1 .4. This may indicate the need for River: S.F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: S.F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. additiona l RS: S200. conveyance additional RS: SOSO. conveyance additional RS: 4810. conveyance cross sections. Prof ile: PF 1 divided by downstream cross sections. Profile: PF 1 divided by downstream cross sections. Profil e: PF 1 divided by downstream This may indicate the need for additional cross sections. River: S.F. LICK CREEK Reach: S.F. Main RS: 4310. Profile: PF 1 conveyance) is less conveyance) is less conveyance) is less Warning:The energy l oss was greater than 1.0 ft (0 .3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: S.F. LICK CREEK Reach: S.F. Main RS: 366S. Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. River: S.F. LICK CREEK Reach: S.F. Main RS: 3S38. Profile : PF 1 Warning:The velocity head has changed by more than O.S ft (O.lS m). This may indicate the need for additional cross sections. Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4 . This may indicate the need for River : S.F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream than 0 .7 or greater than 1.4. This may indicate the need for River: S.F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: S.F. LICK CREEK Reach: S.F. Main Warning:The conveyance ratio (upstream than 0 .7 or greater than 1.4. This may i ndicat e the need for River: S.F. LICK CREEK Reach: S .F . Main Warning:The conveyance r atio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: S.F. LICK CREEK Reach: S.F. Main conveyance additional RS: 3S20. conveyance additional RS: 2880. conveyance additional RS: 2S60. conveyance additional RS: 2210. conveyance additional RS: 1060 divided by downstream conveyance) is less cross sections. Profile: PF 1 divided by downstream conveyance) is less cross sections. Profile: PF 1 divided by downstream conveyance) is less cross sect ions. Profile: PF 1 divided by downstream conveyance) is less cross sections. Profile: PF 1 divided by downstream conveyance) is less cross sections. Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less t han 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: S8600 Warning:The energy l oss was greater than 1.0 ft (0.3 cross section . This may indicate the need for additional cross sections. River: Lick Cr eek Main Reach: Fema X-sect RS: S7300 Warning:The energy l oss was greater than 1.0 ft (0.3 cross section . This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: S6000 Warning:The energy l oss was greater than 1.0 f t (0.3 cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: S4700 Warning :The energy l oss was greater than 1.0 ft (0.3 cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: S3400 Warning:The energy l oss was greater than 1.0 ft (0.3 cross section. This may indicate the need for additional cross sections . Pr ofile: m). between Profile: m). between Profile: m). b etween Profile: m). between Profile: m). between PF 1 the current and previous PF 1 the current and previous PF 1 the current and previous PF 1 the current and previous PF 1 the current and previous River: Lick Creek Main Reach: Fema X-sect RS: 52666 Profile: PF 1 Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 51932 Profile: PF 1 Warning:Divided flow computed for this cross-section . Warning:The energy loss was greater than 1.0 ft (0.3 m). between cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS : 51198 Profile: Warning :Divided flow computed for this cross-section. Warning:The energy loss was greater than 1.0 ft (0.3 m). between cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 50464 Profile: Warning:Divided flow computed for this cross-section. Warning :The energy loss was greater than 1.0 ft (0.3 m). between cross section . This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 49730 Profile: Warning:The energy loss was greater than 1.0 ft (0.3 m). between cross section. This may indicate the need for additional cross sections. the PF 1 the PF 1 the PF 1 the River: Lick Creek Main Reach: Fema X-sect RS: 49120 Profile: PF 1 current and previous current and previous current and previous current and previous Warning:The energy l oss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 47900 Profile: PF 1 Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 46940 Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 45980 Profile: PF 1 Warning:The velocity head has changed by more than 0.5 ft (0 .15 m). This may indicate the need for additional cross sections. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4 . This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1 .0 ft (0 .3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 45020 Profile: PF 1 Warning:Divided flow computed for this cross-section. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 43850 Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1.4. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 42680 Profile: PF 1 Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections . Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: Lick Creek Main Reach: Fema X-sect conveyance divided by downstream conveyance) is less additional cross sections. RS : 42584 Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1 .4 . This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 42583 Profile: PF 1 Note: Yarnell answer is not valid if the water surface is above the low chord or if there is weir flow. The Yarnel l answer has been disregarded. River: Lick Creek Main Reach: Fema X-sect RS: 42540 Profile: PF 1 Warning:The conveyance ratio {upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 42440 Profile: PF 1 Warning:The velocity head has changed by more than 0 .5 ft (0.15 m). This may indicate the need for additional cross sections. Warning:The conveyance ratio {upstream conveyance divided by downstream conveyance) is less than 0 .7 or greater than 1 .4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 41710 Warning:The energy l oss was greater than 1.0 ft (0.3 cross section . This may indicate the need for additional cross sections . River: Lick Creek Main Reach: Fema X-sect RS: 41088 Warning:The energy loss was greater than 1.0 ft (0.3 cross section . This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 40466 Warning:The energy loss was greater than 1.0 ft (0.3 cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 39844 Warning:The energy l oss was greater than 1.0 ft (0.3 cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 39222 Warning :The energy l oss was greater than 1.0 ft (0.3 cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 35280 Profile: m). between Profile: m). between Profile: m). between Profil e: m). between Profile : m). between Profile: PF 1 the current and previous PF 1 the current and previous PF 1 the current and previous PF 1 the current and previous PF 1 the current and previous PF 1 Warning:The conveyance ratio {upstream than 0.7 or greater than 1 .4. conveyance divided by downstream conveyance) is less This may indicate the need for River: Lick Creek Main Reach: Fema X-sect additional cross sections. RS: 34200 Profile: PF 1 Warning:The energy l oss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 33586 Warning:The energy l oss was greater than 1.0 ft (0 .3 cross section . This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 32972 Warning :The energy l oss was greater than 1.0 ft (0.3 cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 32358 Warning:The energy l oss was greater than 1.0 ft (0.3 cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 31744 Warning :Divided flow computed for this cross-section. m). m). m). Profile: PF 1 between the current and previous Profile : PF 1 between the current and previous Profile: PF 1 between the current and previous Profile: PF 1 Warning:The energy l oss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 30520 Profile: PF 1 Warning:The energy l oss was greater than 1.0 ft (0.3 m). between the current and previous cross secti on. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 29910 Profile: PF 1 Warning:The energy l oss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 28690 Profile: PF 1 Warning:The conveyance ratio {upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 26340 Profile : PF 1 Warning:The energy l oss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections . River: Lick Creek Main Reach: Fema X-sect RS: 24490 Warning:The energy loss was greater than 1 .0 ft (0.3 cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 22640 Warning:The energy loss was greater than 1.0 ft (0.3 cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 20790 Warning:The energy loss was greater than 1.0 ft (0 .3 cross section. This may indicate the need for additional cross sections. River: Lick Creek Main Reach: Fema X-sect RS: 20185 Profile: m) . between Profile: m) . between Profile: m). between Profile: PF 1 the current and previous PF 1 the current and previous PF 1 the current and previous PF 1 Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. conveyance divided by downstream conveyance) is less This may indicate the need for River: Lick Creek Main Reach: Fema X-sect additional cross sections. RS: 13905 Profile: PF 1 Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The parabolic search method failed to converge on critical depth. The program will try the cross section slice/secant method to find critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used . River: Lick Creek Main Reach: Fema X-sect RS: 13880.5 Profile: PF 1 Warning:During subcritical analysis, while trying to calculate culvert and weir flow, the program could not get a balance of energy within the specified tolerance and number of trials. The program used the solution with the minimum error. Warning:The weir over culvert is submerged. River: Lick Creek Main Reach: Fema X-sect RS: 13857 Profile: PF 1 Warning:The conveyance ratio (upstream than 0.7 or greater than 1.4. This may indicate the need for River: Lick Creek Main Reach: Fema X-sect conveyance divided by downstream conveyance) is less additional cross sections. RS: 13856 Profile: PF 1 Warning:The parabolic search method failed to converge on critical depth. The program will try the cross section slice/secant method to find critical depth. River: Lick Creek Main Reach: Fema X-sect RS: 12880 Profile: PF 1 Warning:The cross-section end points had to be extended vertically for the computed water surface. River: Lick Creek Main Reach: Fema X-sect RS: 10815 Profile: PF 1 Warning:The cross-section end points had to be extended vertically for the computed water surface. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections .