HomeMy WebLinkAboutStaff CommentsCITY OF COLLEGE STATION
Nome of To A&M University'
MEMORANDUM
DATE: September 12, 2013
TO: Adam Wallace, via e-mail: adamCa2atmsurveving.com✓
FROM: Jason Schubert, AICP, Principal Planner
SUBJECT: WEST PARK LOTS 9R&IOR BLK 6 (FP -MINOR)
Thank you for the submittal of your FINAL PLAT -MINOR OR AMENDING application. This
project will be distributed to staff next week for their review
PC: Donald Keith Sewell, via e-mail: keithno agshacks.com f
P&DS Project No. 13-00900192
,Planning & Development Services
P.O. BOX q)60 • 11011'EXAS AVENUE • COLLEGE STA110N •'TEXAS • 17842
CITY OF COLLEGE STATION
Home of Texas A&M University'
MEMORANDUM
DATE: September 23, 2013
TO: Adam Wallace, via e-mail:
FROM
SUBJECT:
Morgan Hester, Staff Planner
WEST PARK LOTS 9R & 101
Staff reviewed the above -mentioned final plat as requested. The following page is a list of staff
review comments detailing items that need to be addressed:
One (1) 24"x36" copy of the revised final plat;
Parkland Dedication in the amount of $1,261 must be submitted prior to the filing
of the final plat.
After Staff approval, the following will be required:
One (1) Mylar original of the revised final plat; and
One (1) copy of the digital file of the final plat on diskette or e-mail to:
pdsd ig italsubm ittal (a)cstx. gov.
Please note that this application will expire in 90 days from the date of this memo, if the
applicant has not provided written response comments and revised documents to the
Administrator that seek to address the staff review comments contained herein.
Please note that a Mylar original of the revised final plat will be required after Staff approval and
prior to the filing of the plat. If you have any questions or need additional information, please call
me at 979.764.3570.
Attachments: Staff Review Comments
CC: Donald Keith Sewell, via e-mail: keith(aagshacks.comv_'_*�
P&DS Project No. 13-00900192
Planning 6, Development Services
P.O. BOX 9960 • I I W TF„XAS AVENUE • COLLEGE STATION • TEXAS • 7 7811
TEI,. 979 e 64.3570 - FAX. 979.76i.3°496
cstx.gov/devservices
STAFF REVIEW COMMENTS NO. 1
Project: West Park Lots 9R &10 Block 6 (FP -Minor)
(13-00900192)
PLANNING
1. Please revise the title block to show that this is the Final Plat of Lots 9R and 10R, Block 6
West Park Addition Being a Minor Replat of 7' of Lot 8, Lots 9 & 10, Block 6 West Park
Addition.
2. As this is a Minor Plat, please remove the Certificate of Planning & Zoning and add the
Certificate of City Planner:
I, , City Planner of the City of College Station, Texas, hereby certify that this
Subdivision Plat conforms to the requirements of the Subdivision Regulations of the City of
College Station.
City Planner
City of College Station
3. Please move Note 8 in the Survey Notes box.
4. Please revise the title of the original to `Original Plat'.
5. Please note that any changes made to the plans, that have not been requested by the City
of College Station, must be explained in your next transmittal letter and "bubbled" on your
plans. Any additional changes on these plans that the City has not been made aware of will
constitute a completely new review.
6. Please note that you may be required to submit paid tax certificates if they are not current
prior to the filing of your plat.
Reviewed by: Morgan Hester
ENGINEERING COMMENTS NO. 1
Date: September 17, 2013
1. Please add a 10' public utility easement along the rear of the lots.
2. The metes and bounds description does not match the calls on the plat. Please revise.
3. Please remove the improvements from the original plat side. FYI- the sanitary sewer is
located in the rear alley and the water is located in Grove Street.
4. Please change the label in the survey legend from utility easement to public utility
easement.
Reviewed by: Danielle Singh Date: September 23, 2013
ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION
1. SITE PLAN/PLAT: Developer will provide CSU with a digital, AutoCAD dwg format, version
of plat and / or site plan as soon as it is available. Email to: wdavisCcDcstx.gov
2. LOAD DATA: The developer will provide load data to CSU as soon as it is available. This
information is critical for CSU to accurately determine the size and number of transformers,
and other equipment, required to provide service to the project. Failure to provide load data
will result in construction delays and, due to clearance requirements, could affect the final
building footprint. Delivery time for transformers and other equipment not in stock is
approximate 26 weeks.
3. EASEMENTS: Developer provides temporary blanket easement for construction purposes
and upon completion of project must provide descriptive easements for electric infrastructure
as designed by CSU.
4. If easements are existing, the developer will be responsible for locating easements on site to
insure that electrical infrastructure is installed within easement boundaries.
5. The following easements will be required:
• 10' PUE along Grove Street
• 5' PUE along all side exterior and side interior lot lines
• 10' PUE along the back lot line, parallel to the 15' alley.
GENERAL ELECTRICAL COMMENTS
1. Developer installs conduit per CSU specs and design.
2. CSU will provide drawings for electrical installation.
3. Developer provides 30' of rigid or IMC conduit for each riser conduit. CSU installs riser.
4. Developer will intercept existing conduit at designated transformers or other existing devices
and extend as required.
5. If conduit does not exist at designated transformer or other existing devices, developer will
furnish and install conduit as shown on CSU electrical layout.
6. Developer pours electric device pads or footings, i.e. transformers, pull boxes, or other
device, per CSU specs and design.
7. Developer installs pull boxes and secondary pedestals per CSU specs and design, Pull
boxes and secondary pedestals provided by CSU.
8. Final site plan must show all proposed electrical facilities necessary to provide electrical
service, i.e. transformers, pull boxes, or switchgears, all meter locations, and conduit routing
as designed by CSU.
9. To discuss any of the above electrical comments please contact or Weldon Davis at
979.764.5027.
Reviewed by: Weldon Davis Date: September 17, 2013
SANITATION
1. Sanitation is ok with this project.
Reviewed by: Wally Urrutia Date: September 20, 2013
CITY OF COLLEGE STATION
Home ofTcxAdaM UxLye tyI
MEMORANDUM
October 24, 2013 / w 1��\A
TO: Adam Wallace, via email: adam@aTmSurveying.com ✓ ` `
FROM: Morgan Hester, Staff Planner
SUBJECT: WEST PARK LOTS 9R$10R BLK 6 (FP -MINOR) - Final Plat
Staff has approved the above -mentioned final plat as requested. Please be aware that as a
condition of the approval, all existing structures encroaching into any setbacks must be moved
or removed prior to the filing of the plat.
The following page is a list of items that need to be addressed:
One (1) 24"x36" mylar of the revised final plat;
Parkland Dedication in the amount of $1,261 must be submitted prior to the filing
of the final plat; and
One (1) copy of the digital file of the final plat on diskette or e-mail to
pdsdig italsubmittal(@cstx.gov.
Please note that this application will expire in 90 days from the date of this memo, if the
applicant has not provided written response comments and revised documents to the
Administrator that seek to address the staff review comments contained herein.
If you have any questions or need additional information, please call me at 979.764.3570.
J�C
cc: Donald Keith Sewell, via e-mail: keithAagshacks.com ✓ ��
Case file #13-00900192
Planning drDe elapir tServices
P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77842
TEL. 979.764.3570 • FAR 979.764.3496
cstx.gov/devservices