Loading...
HomeMy WebLinkAboutGradation ReportSchultz Engineering, LLC Office: 979.764.3900 Fax:979.764.3910 December 31, 2014 Kevin Ferrer Graduate Civil Engineer City of College Station 1101 Texas Avenue College Station, TX 77840 Re: CASTLEGATE H SEC 204 (FP)—13-00900198 Dear Mr. Ferrer: Attached are test results for the lime stabilized subgrade for a portion of W. S. Phillips Parkway in Section 204 of the above referenced subdivision. The lime stabilized subgrade did not meet the pH requirement of 12.4 as shown on report Al141070.0005. The Plasticity Index, PI, of the samples was 18 or less for the samples taken at Stations 27+50, 30+50, and 33+50. Report .0007 shows the thickness of the lime stabilized subgrade at these locations to be 1.25" to 2" greater than the required thickness of 8". The additional thickness reduced the amount of lime in the soil thereby also reducing the pH. Based on the thickness and PI of the lime stabilized subgrade and since reinforced concrete pavement is being used for this street, it is my recommendation to accept the lime stabilized subgrade at Stations 27+50, 30+50, and 33+50 with the condition that the subgrade meet the required moisture and density. The subgrade at Station 24+50 is being remixed and will be tested after the mixing to see if the pH and PI meet the specifications. If you have any questions, please do not hesitate to call. Very truly yours, Schultz Engineering, LLC. Attachments P.O. Box 11995 • College Station, Texas 77842 sch ultzengineeringl Ic. com GRADATION REPORT ReportNumber: A1141070.0005 lrerracon Service Date: 12/24/14 6198 Imperial Loop Report Date: 12/30/14 Revision 2 - PI results College Station, TX 77845 979-846-3767 Reg No: F-3272 Client Project 3-D Development Castlegate Section 204 Attn: Wallace Phillips Victoria Avenue / Castlegate 4490 Castlegate Dr College Station, TX 77845 College Station, TX 77845 ProiectNumber: A1141070 On December 23, 2014, a Terracon Consultants, Inc., representative was present at the above referenced project to obtain 4 samples of lime -treated material and returned to the laboratory. The samples are being prepared for Plasticity Index, pH, and Optimum Moisture and Density Relationship. Results of the tests performed will be shown on Report Nos. A I141070.0005A and A 1141070.0005B. A Terracon Consultants, Inc., representative also secured 4 samples of pulver-mixed, lime -treated soil for testing to determine the gradation. The tests were performed on site in accordance with applicable ASTM procedures and the results are shown below. Test # Location % Passing 1-3/4" % Passing 3/4" % Passing #4 pH PI W.S. Phillip Parkway 1 Station 33+50 100 96 69 12.2* 8 2 Station30+50 100 100 74 12.3* 7 3 Station27+50 100 100 68 12.1* 15 4 Station 24+50 100 100 61 11.0* 37* Specification Reauirements: P/."Sieve: Minimum 100%Passing '31"Sieve: Minimum 85%Passing # 4 Sieve: Minimum 60%Pa tsing pH: Minimum of12.4 PI Range: 7-18 *Does not meet specifications Services: Terracon Rep.: Mohammed Mobeen Reported To: Contractor: Start/Stop: 1430-1530 Report Distribution: (1) 3-D Development, Wallace Phillips (1) 3-D Developmom, Dusty Phillips l (l) City of College Station TX, Danielle CiCityo£College Station TX, Israel Reviewed By: Koine Singh Koite (p Schultz Engineering LLC, Joe Schultz (1) Terracon Consultants, Inc., Mark Ma k E.Domak, P.E. Domak Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. C170001, I0-16-13, Rev.10 Page 1 of 1 DEPTH CHECKS REPORT Report Number: A1141070.0007 Service Date: 12/31/14 6198 Imperial Loop Report Date: 12/31/14 College Station, TX 77845 979-846-3767 Reg No: F-3272 Client Project 3-D Development Castlegate Section 204 Attn: Wallace Phillips Victoria Avenue/Castlegate 4490 Castlegate Dr College Station, TX 77845 College Station, TX 77845 ProiectNumber: A1141070 On December 31, 2014, a Terracon Consultants, Inc., representative was present at the above -referenced project to perform lime depth checks on W.S. Phillips Parkway. Results of the tests performed are shown below. TEST LOCATION W.S. Phillips Parkway (1) Station 23+50, right of centerline (2) Station 25+50, centerline (3) Station 27+50, left of centerline (4) Station 29+50, right of centerline (5) Station 31+50, centerline (6) Station 33+50, left of centerline THICKNESS (INCHES) Measurement to the Nearest''/T 9 8 '/z 9 '/z 9 '/a 9 10 Services: Traveled to the project site to provide testing/observation services as requested. Terracon Rep.: Mohammed Mobeen Start/Stop: 0715-0815 Reported To: Contractor: Report Distribution: q (1)3-D Development, Wallace Phillips (1)3-D Development Dusty Phillips /+ (1) City of College Station TX, Danielle (1) City of College Station TX, Israel Reviewed By: j 9 Singh Koite (1) Schulu Engineering LLC, Joe Schultz (1) Terzacon Consultants, I e., Mark Mark E.Domak, P.E. Domak Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CT000t, 10-16-13,Rev.10 Page I of 1