Loading...
HomeMy WebLinkAboutStaff Comments(*/" CITY OF COLLEGE STATION Ho. ofTexx At4M UW.v iry' MEMORANDUM March 19, 2013 TO: Travis Martinek, via email: travis@clarkewyndham.com FROM: Morgan Hester, Staff Planner SUBJECT: INDIAN LAKES PH 12 (FP) - Final Plat Staff reviewed the above -mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by any Monday at 10:00am, your project will be placed on the next available Planning and Zoning Commission meeting held in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24'k36" copy of the revised final plat, Thirteen (13) 11"x17" copies of the revised final plat, _ One (1) copy of the digital file of the final plat on diskette or e-mail to pdsdioitalsubmittaI0,cs1x.00v; and The Mylar original of the revised final plat with the owner and County Judge's signatures (will be required after the County's approval). Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If all comments have not been addressed, your project will not be scheduled for the Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://vvww. cstx. g ov/hom e! n d ex. asp?p aqe=2481 Please note that a Mylar original of the revised final plat will be required after P&Z approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments cc: Kevin McClure, McClure & Browne Engineering/Surveying, Inc., via email: kevinm@mcclurebrowne.com Gary Arnold, Brazos County Planning & Traffic, via fax 775.0453 Case file #13-00900056 P&nxing &Deve%pmmt Services P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77942 TEL. 979.764.3570 • FAX. 979.764.3496 atx.gov/devservims STAFF REVIEW COMMENTS NO. 1 Project: INDIAN LAKES PH 12 (FP) - 13-00900056 PLANNING 1. Please only show what has been designated as Indian Lakes on the Vicinity Map, removing the reserve tracts from other developments. 2. Please note that you, the applicant, are responsible for scheduling the plat for consideration by the County Commissioner's Court and for getting the County Judge's signature on the Mylar after they approve the plat. 3. Please note that any changes made to the plans, which have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not been made aware of will constitute a completely new review. Reviewed by: Morgan Hester Date: March 12, 2013 ENGINEERING COMMENTS NO. 1 Plat 1. Please tie lot corners to the City's horizontal control monument. 2. Add a note that all proposed structures must be no more than 500-ft from a fire hydrant based on the lay of hose along the street. 3. When will the portion of the property between Ph.10 & 12 be platted? Construction Documents 1. Verify that the minimum 4-ft cover is being provided. 2. FYI ... We will be recommending that the plat be conditionally approved pending the infrastructure being constructed or surety provided for it. 3. Should there be a drainage easement on Lots 5 & 8? 4. How will cross -lot drainage be handled? 5. Have the gas company's been contacted regarding construction requirements around pipelines? Provide correspondence indicating requirements. 6. Sh.6 — Please show the gas pipes crossing the waterlines in profile and label the separation distance. 7. Sh.6 — There should be a 3-ft separation distance between the flowline of the ditch and the top of the pipe. 8. Sh.7 — Label the 4x6 reducer on the waterline. 9. Sh.7 — Should the service leads to Lots 8 & 9 be 1.5" services? Reviewed by: Erika Bridges Date: March 18, 2013 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. This project location is outside of CSU certification area. CSU will not provide electric service to this project location. GENERAL ELECTRICAL COMMENTS 1. To discuss any of the above electrical comments please contact Gilbert Martinez at 979.764.6255. Reviewed by: Gilbert Martinez Date: March 18, 2013 CITY OF COLLEGE STATION Hom of T. A&M Uhi rnry' MEMORANDUM April 29, 2013 TO: Travis Martinek, via email: travis@clarkewyndham.com FROM: Morgan Hester, Staff Planner SUBJECT: INDIAN LAKES PH 12 (FP) - Final Plat Staff reviewed the above -mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by any Monday at 10:00am, your project will be placed on the next available Planning and Zoning Commission meeting held in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24'k36" copy of the revised final plat, Thirteen (13) 11"x17" copies of the revised final plat, _ One (1) copy of the digital file of the final plat on diskette or e-mail to pdsdioitalsubmittaI0,cs1x.00v; and The Mylar original of the revised final plat with the owner and County Judge's signatures (will be required after the County's approval). Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If all comments have not been addressed, your project will not be scheduled for the Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://vvww. cstx. g ov/hom e! n d ex. asp?p aqe=2481 Please note that a Mylar original of the revised final plat will be required after P&Z approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments cc: Kevin McClure, McClure & Browne Engineering/Surveying, Inc., via email: kevinm@mcclurebrowne.com Gary Arnold, Brazos County Planning & Traffic, via fax 775.0453 Case file #13-00900056 Planning 6, Dmelopmmf Services P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77942 TEL. 979.764.3570 • FAX. 979.764.3496 csa.gov/Aevservims STAFF REVIEW COMMENTS NO. 2 Project: INDIAN LAKES PH 12 (FP) - 13-00900056 PLANNING 1. Please be aware that this plat is still under review by the County and separate comments may be made. Reviewed by: Morgan Hester Date: April 29, 2013 ENGINEERING COMMENTS NO. 2 1. (Repeat) Verify that the minimum 4-ft cover is being provided. There are still a few locations where the 4-ft minimum cover is not being provided (i.e. WA-1, Sta.4+20 & Sta.7+45). Also, please specify the casing for the WA-2 street crossing and show it extending beyond the ditches. 2. (Repeat) Have the gas company's been contacted regarding construction requirements around pipelines? Provide correspondence indicating requirements. Owner has not provided correspondence yet. 3. FYI ... We will be recommending that the plat be conditionally approved pending the infrastructure being constructed or surety provided for it. Reviewed by: Erika Bridges Date: April 25, 2013