Loading...
HomeMy WebLinkAboutFolderFOR OFFICE USE ONLY P&ZCASENO.: 03-~/7 DATE SUBMITTED: /-;l.S--O°"b SITE PLAN APPLICATION qDC:OS~~S MINIMUM SUBMITTAL REQUIREMENTS 0' $200.00 Site plan application and review fee. B $200.00 Development permit fee. ~ $600.00 Public infrastructure inspection fee, if applicable. (This fee is payable if construction of a public wat~rline, sewerline, sidewalk, street or drainage facilities is involved.) LJ:Y Ten {10) folded copies of site plan. GY A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are not checked off. ~f><:: Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). NAMEOFPROJECT _____________ ~G=r~a~ha=m..:..:......::C~o"-'rn~e~r~P~la=z=a ___________ _ ADDRESS ________________ __;:C~o"-'rn~e~r~o~f~G~ra=h=a"-"'m-'-'--'R=oa=d=-&=-=S~H'-6=-W-'-'--"e=s"'"--tF~r~o~nt=a~g=e~R=o=ad=-~ LEGAL DESCRIPTION --------------=L=ot=s-'1'--6=--=B"'"lo"""'c""'-k'-1'--------------- APPLICANT (Primary Contact for the Project): Name _________ T~e~d_W~h~itm~er'--------E-Mail ______________ _ Street Address ---~-------------=2=50""°'8=-M:.o.=e'-'-rr"""'im..:..::a=c---=-C=ou=r-"--t __________ _ City College Station State TX Zip Code 77845 Phone Number (979) 764-2667 FaxNumber ~l"-b'iJ-1Jo4 PROPERTY OWNER'S INFORMATION: Name _________ T.:....:e=d=-W.:....:....:.;h=itm:..:..=e'-r _______ E-Mail ______________ _ Street Address -----------------=2=50""°'8=-M:.o.=e'-'-rr"-"'im..:..::a=c~C"-'o'--=u"'"'rt'------------ City College Station State TX Zip Code ____ 7_7_8_4_5 ___ _ Phone Number (979) 764-2667 Fax Number b 'f 3 -I 304- ARCHITECT OR ENGINEER'S INFORMATION: {.. Name --------~J~oe~S~ch~u'-lt=z________ E-Mail -----'-"jo=e=Ji'"'-'u=lt=z=@=te=x=c=o~n."-'n=et"----­ Street Address -----------------~1 "'"--70::....:7_G=..:....::ra=h=a'-'-m'--'R-"o=a=d'------------- City ____ __cc::....:o'"""ll=eg.,_e=-=St=a'-'-'-tio=n-'------State ____ T_X ___ _ Zip Code ____ 7_;7~8_4~5 ___ _ PhoneNumber _____ ~(9~7~9~)=69::....:0=--~77'-1'-1'----~ Fax Number.-~~~---~<~9_79~)~~~0~0~9~7-9~r~--~ 1tplf. 7150 OTHER CONTACTS {Please specify type of contact, i.e . project manager, potential buyer, local contact, etc.) Name ___________________ _ E-Mail ______________ _ Street Address ----------------------------------- City ______________ State ________ _ Zip Code _________ _ PhoneNumber ________ Fax Number _____________________ ~ Site Plan Appli cation.doc 7/22/03 1 of 6 CURRsNTZONING ____________ ~C~-2=----------------- PRESENTUSEOFPROPERTY ________ ~V=a=ca=n=t _____________ _ PROPOSED USE OF PROPERTY _______ __::C::..::o'..!..!m-"-m=e::..:..r=ic=al'-------------- VARIANCE(S) REQUESTED AND REASON(S) ___ _:_N=o.:...:..ne;:;___ ____________ _ #OF PARKING SPACES REQUIRED _---'-N--"-/:.....:.A __ # OF PARKING SPACES PROVIDED _ _____:_;N::....:.../A-=---- MULTl-FAMIL Y RESIDENTIAL PARKLAND DEDICATION Total Acreage __ # of Multi-Family Dwelling Units Floodplain Acreage __ x $452 = $ Housing Units __ __ #of acres in floodplain # of 1 Bedroom Units # of acres in detention #of 2 Bedroom Units 1.093 #of acres in greenways #of 3 Bedroom Units --__ date dedication approved by Parks Board #of 4 Bedroom Units COMMERCIAL FOR 2 BEDROOM UNITS ONLY Total Acreage 10.73 __ #Bedrooms= 132 sq . ft. Building Square Feet __ __ #Bedrooms < 132 sq . ft. Floodplain Acreage __ NOTE: Parkland Dedication fee is due prior to the issuance of a Building Permit. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. Signature of Owner, Agent or Applicant= Date S ITE PLAN Cl IECKUST 2 of6 Si te Plan Application.doc 7/22/03 SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION .Application is hereby made for the following development sgecifi.c waterway alterations: Pr;" ~k !Jc-;" cw o1 f ACKNOWLEDGMENTS: IJ10.•"''J(. :f~ro., ....... :h c;..._J p ... .\:i~ic. vJ.,..\v •~ ftJ.__ wh.;f-..,...u-)t'. vvu-'""/J''"'"" .. ;:t f I, __ , design engineer/owner, hereby acknowledge or affirm that: I The information and conclusions contained in the above plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards . Property Owner(st- As a condition of approval of this permit application, I agree to construct the improvements proposed in this application according to these documents and the requirements of Chapter 13 of th Coll e Stati n City Code. CERTIFICATIONS: A. I, , certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the 100-year storm. Engineer Date B. I, , certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended. Engineer Date ~ ~541\.,__ p. s t-h_" l \--i---~~ .... ~~'}'·~h C. I, _\ certify that the alterations or developm~~vei·Gf~ ... permit shall not diminish the flood- carrying capacity of the waterway adjoining orJerQ$sin · p~r.Hl~d site and that such alterations or development are consistent with requireme~~of..tile.. l .. Rf •• 9?.~~e Station City Code, Chapter 13 co cerning encroach nts of fl odways and l~~~~Jl.~.~.~.~.~~ ... J li:P\L\ 65889 :$J _.., -..., z ,...-.;:'\? ~fo-<' .... r~ ~Q.•" l/J, 1 -L--u ..J Engineer •,f &;;~~.1~.p,~~~;.a.:·"""~""~ ..... ,,,.._ ___________ _ \\."-. NAL --.,,~- D. I, , do certify that the proposed alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study. Engineer Date Conditions or comments as part of approval: ------------------------ In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. SITE PLAN CllECKLIST Site 1'1;111.doc 7122103 3 of6 1. 2. 3. SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 10 FOLDED COPIES OF SITE PLAN FOR REVIEW SITE PLAN MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: Sheet size -24" x 36" (minimum). A key map (not necessarily to scale). Title block to include: ~ Name, address, location, and legal description ~ Name, address, and telephone number of applicant ~ Name, address, and telephone number of developer/owner (if differs from applicant) ~ Name, address, and telephone number of architect/engineer (if differs from applicant) ~ Date of submittal ~ Total site area 4. 5. 6. 7. 8. ~ D N/A D N/A D N/A D N/A North arrow. Scale should be largest standard engineering scale possible on sheet. Ownership and current zoning of parcel and all abutting parcels. Existing locations of the following on or adjacent to the subject site: Streets and sidewalks (R.O.W .). Driveways (opposite and adjacent per Driveway Ordinance 1961 ). Buildings. Water courses. Show all easements clearly designating as existing and type (utility, access, etc.). 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if there is none on the site. Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings, and drainage inlets. Meter locations. Topography (2' max or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) Proposed location, type and dimensions of the following.: Phasing. Each phase must be able to stand alone to meet ordinance requirements. The gross square footage of all buildings and structures and the proposed use of each. If different uses are to be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Table A). Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum parking space is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number of parking spaces required by ordinance and provided by proposal. Handicap parking spaces. Slll:l'l./\1 ('lfH 'Kl.ISI 4 or6 ~i ll' "'"II /\ppfll'CJlinn.dtH: 7'22 0.1 NOTE: 0 N/A Parking Islands. Ra ised landscape islands, (6" raised curb) a minimum of 180 sq ft are required at both ends of every parking row (greenspace area contiguous to the end island maybe applied toward th e required 180 sq . ft .). Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be provided. All required islands must be landscaped or set with decorative pavers, or stamped dyed concrete or other decorative materials as approved. [g) Drives. Minimum drive aisle width is 23' with head-in parking or 20' without parking. [g) Curb cuts. For each proposed curb cut (including driveways, streets, alleys , etc.) locate existing cu rb cuts on the same opposite side of the street to determine separation distances between existing and proposed curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance 1961 for driveway location and design requirements.) D N/A Security gates (show swing path and design specs with colors). [g) Sidewalks (both public and private). Sidewalks are required at time of development if property has frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. (Refer to Section 10.2 of the Zoning Ordinance). D N/A Medians. Show any and all traffic medians to be constructed on site. 0 N/A Landscape Reserve. A twenty four foot setback from R.O.W. to curb of parki ng lot is required . Pavement may encroach into this 24' reserve by up to 1134 square feet if streetscape requirement can still be met In no case may the pavement be less than 6' from the property line. [g) Common open spaces sites D N/A Loading docks [g) Detention ponds [g) Guardrails 0 N/A Retaining walls D N/A All required and other types of fences (a 6' privacy fence is required between industrial/commercial and residential developments as well as between multi-family and single family developments). 0 N/A Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from streets or residential areas. Gates are discouraged and visual screening is required . (Minimum 12 x 12 pad required.) [g) Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated by separate instrument list by volume and page. [g) Utilities (noting size and designate as proposed) within or adjacent to the proposed site , including building transformer locations, above ground and underground service connections to buildings. D N/A Meter locations (must be located in public R.O.W. or public utility easement.). [g) Proposed grading (1 ' max for proposed or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) Refer to sheet 2 of the Graham Corner Plaza Plans. [g) Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district other than R-1, R-1 A, or R-2 must be within 300 feet of a fire hydrant as measured along a public street, highway or designated fire lane. D N/A Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by parked cars or a structure. 0 N/A Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement edge of a public street or highway. Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as defined in the Zoning Ordinance Section 9 before a building permit can be issued. D N/A 9. Will building be sprinkled? Yes D No D D N/A 10. 11 . If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted . Wheelstops may be required when cars overhang onto property not owned by the applicant or where there may be conflict with handicap accessible routes or above ground utilities, signs or other conflicts. Show curb and pavement detail. A 6" raised curb is required around all edges of all parts of all paved areas without exception . (To include island, planting areas , access ways, dumpster locations, utility pads, etc.) Curb details may be found in the Zoning Ordinance Section 9 and alternatives to those standards must be approved by the City Engineer. No exception will be made for areas designated as "re served for future parking" Site Plan 1\pplic;1tin11.drn.: 7 22 O~ 5 of 6 0 N/A 12. D D D D D D D D D 0 N/A 13. 14. 15. 16. D N/A 17. D N/A 18. 0 N/A 19. 20. Landscape plans as required in Section 11 of the Zoning Ordinance (See Ordinance # 1638.) The landscaping plan can be shown on a separate sheet if too much information is on the original site plan. If requesting protected tree points, then those trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans such as: required point calculations additional streetscape points required. Streetscape compliance is required on all streets larger than a residential street. calculations for # of street trees required and proposed (proposed street tree points will accrue toward total landscaping points.) proposed new plantings with points earned proposed locations of new plantings screening of parking lots screening of dumpsters, detention ponds, transformers , A/C units, loading docks, propane tanks, utility demarcation point on buildings, or other areas potentially visually offensive. existing landscaping to remain show existing trees to be barricaded and barricade plan. Protected points will only be awarded if barricades are up before the first development permit is issued . Show irrigation system plan . (or provide note on how irrigation system requirement will be met prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and will be sized by city according to irrigation demand submitted by applic_ant and must include backflow prevention protection. Is there any landscaping in TxDOT R.O .W.? If yes , then TxDOT permit must be submitted. Will there be any utilities in TxDOT R.O.W .? If yes , then TxDOT permit must be submitted. Will there be access from a TxDOT R.O.W.? If yes , then TxDOT permit must be submitted. Yes D No ~ Yes D No ~ Yes ~ No D The total number of multi-family buildings and units to be constructed on the proposed project site. The density of dwelling units per acre of the proposed project. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average demands in gallons per minute) and sewer loadings (maximum demands in gallons per day). Are there impact fees associated with this development? Yes ~ No D NOTE: Signs are to be permitted separately. Sit e Plan Application.doc 7/22/03 6 of 6 ~-v DEVELOPMENT PERMIT PERMIT NO. 03-55 Project: Graham Corner Plaza COlll<Ol STATION FOR AREAS INSIDE THE SPECIAL FLOOD HAZARD AREA RE : CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: Graham Corner Plaza Lots 1-6 Block 1 DATE OF ISSUE: 08/07/03 OWNER: Ted Whitmer 2508 Merrimac Court College Station, Texas 77845 TYPE OF DEVELOPMENT: SPECIAL CONDITIONS: Clearing Permit SITE ADDRESS: 4030 State Highway 6 DRAINAGE BASIN: Lick Creek VALID FOR 6 MONTHS CONTRACTOR: All construction must be in compliance with the approved construction plans All trees must be barricaded, as shown on plans, prior to any construction. Any trees not barricaded will not count towards landscaping points. Barricades must be 1' per caliper inch of the tree diameter. Erosion Control per the approved plans must be in place for duration of the project. The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria. If it is determined the prescribed erosion control measures are ineffective to retain all sediment onsite, it is the contractors responsibility to implement measures that will meet City, State and Federal requirements. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used for temporary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetation be returned to its original condition , placement and state. The Owner and/or Contractor shall be responsible for any damage to adjacent properties , city streets or infrastructure due to heavy machinery and/or equipment as well as erosion, siltation or sedimentation resulting from the permitted work. Any trees required to be protected by ordinance or as part of the landscape plan must be completely fenced before any operations of this permit can begin. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction , erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development of an area inside the special flood hazard area. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit application for the above named project and all of the codes and ordinances of the City of Coll e Station that apply. Date Cf~ DEVELOPMENT PERMIT PERMIT NO. 03-55b Project: Graham Corner Plaza COLLl<il !;TATION FOR AREAS INSIDE THE SPECIAL FLOOD HAZARD AREA RE : CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: Graham Corner Plaza Lots 1-6 Block 1 DATE OF ISSUE: 09/16/03 OWNER: Ted Whitmer 2508 Merrimac Court College Station, Texas 77845 TYPE OF DEVELOPMENT: SPECIAL CONDITIONS: SITE ADDRESS: 4030 State Highway 6 DRAINAGE BASIN: Lick Creek VALID FOR 9 MONTHS CONTRACTOR: Full Development Permit -Private Drive and Private Storm Sewer All construction must be in compliance with the approved construction plans All trees must be barricaded, as shown on plans, prior to any construction. Any trees not barricaded will not count towards landscaping points. Barricades must be 1' per caliper inch of the tree diameter. Erosion Control per the approved plans must be in place for duration of the project. The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria. If it is determined the prescribed erosion control measures are ineffective to retain all sediment onsite, it is the contractors responsibility to implement measures that will meet City, State and Federal requirements. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used for temporary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetation be returned to its original condition, placement and state. The Owner and/or Contractor shall be responsible for any damage to adjacent properties, city streets or infrastructure due to heavy machinery and/or equipment as well as erosion, siltation or sedimentation resulting from the permitted work. Any trees required to be protected by ordinance or as part of the landscape plan must be completely fenced before any operations of this permit can begin. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station , measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development of an area inside the special flood hazard area. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit application for the above named project and all of the codes and ordinances of the City of Co e Station th t ply. 1?1-'le -03 Date 7..-/6 ·0 ~ Date (t-~ DEVELOPMENT PERMIT PERMIT NO. 03-55a Project: Graham Corner Plaza COlllGl STATION FOR AREAS INSIDE THE SPECIAL FLOOD HAZARD AREA RE : CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: Graham Corner Plaza Lots 1-6 Block 1 DATE OF ISSUE: 08/18/03 OWNER: Ted Whitmer 2508 Merrimac Court College Station, Texas 77845 TYPE OF DEVELOPMENT: SPECIAL CONDITIONS: SITE ADDRESS: 4030 State Highway 6 DRAINAGE BASIN: Lick Creek VALID FOR 9 MONTHS CONTRACTOR: Full Development Permit All construction must be in compliance with the approved construction plans All trees must be barricaded, as shown on plans, prior to any construction. Any trees not barricaded will not count towards landscaping points. Barricades must be 1' per caliper inch of the tree diameter. Erosion Control per the approved plans must be in place for duration of the project. The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria. If it is determined the prescribed erosion control measures are ineffective to retain all sediment onsite, it is the contractors responsibility to implement measures that will meet City, State and Federal requirements. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used for temporary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetation be returned to its original condition, placement and state. The Owner and/or Contractor shall be responsible for any damage to adjacent properties, city streets or infrastructure due to heavy machinery and/or equipment as well as erosion , siltation or sedimentation resulting from the permitted work. Any trees required to be protected by ordinance or as part of the landscape plan must be completely fenced before any operations of this permit can begin. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction , erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development of an area inside the special flood hazard area. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit application for the above named project and all of the codes and ordinances of the City of College Station that apply. ~ti mma or1r;;,9resen a 1ve ---=/'&if Date g -\ q -03 Owner/ Agent/Contractor Date CONSTRUCTION COST ESTIMATE 27-May-03 WATER AND SANITARY SEWER IMPROVEMENTS GRAHAM CORNER PLAZA COLLEGE STATION, TEXAS Item Estimated Unit Estimated No. Description Quantity Price Cost General Mobilization/layout LS $5,000.00 $5 ,000 2 Site Preparation 0.5 AC $6,000.00 $3 ,000 3 Silt Fence 1,200 LF $2.50 $3 ,000 4 Construction Exit-Rock 25 TONS $50.00 $1 ,250 5 Hydromulch/Hydroseeding 6,000 SY $0.50 $3,000 Subtotal $15,250 Water Lines 6 12" Water PVC CL200 (C909) structural 50 LF $44.00 $2 ,200 7 12" Water PVC CL200 (C909) non-structural 480 LF $32.00 $15,360 8 8" Water PVC CL200 (C909) structural 130 LF $28.00 $3,640 9 . 8" Water PVC CL200 (C909) non-structural 760 LF $22.00 $16,720 10 Connect To Existing Line LS $500.00 $500 11 Replace Concrete Sidewalk -6' wide 150 SF $8.00 $1 ,200 12 12" Gate Valves 2 EA $1,400.00 $2 ,800 13 8" Gate Valves 6 EA $650.00 $3,900 14 24"x 8" Tapping Sleeve & Valves 1 EA $4,500.00 $4,500 15 12" x 8" M.J. Tees 2 EA $550.00 $1 , 100 16 8" M.J. Tees 2 EA $350.00 $700 17 8" x 6" M.J. Tees 2 EA $350.00 $700 18 12" M.J. Bends -45 deg. 2 EA $550.00 $1 , 100 19 8" M.J. Bends -45 deg. 2 EA $350.00 $700 20 8" M.J. Bends -22.5 deg. EA $350.00 $350 21 8" M.J. Bends -11 .25 deg. EA $350.00 $350 22 2" Blow off Assembly 3 EA $450.00 $1,350 23 Fire Hydrant Assembly 2 EA $2 ,200.00 $4,400 Subtotal $61,570 Sanitary Sewer Lines 24 8" SOR 26 Pipe -2241 -Structural 20 LF $38.00 $760 25 8" SOR 26 Pipe -3034 -Structural 530 LF $35.00 $18,550 26 8" SOR 26 Pipe -3034 -Non-Structural 30 LF $24.00 $720 27 6" SOR 26 Pipe -2241 -Structural 20 LF $36.00 $720 28 6" SOR 26 Pipe -3034 -Structural 30 LF $32.00 $960 29 6" SOR 26 Pipe -3034 -Non-Structural 100 LF $22.00 $2 ,200 30 Cement Sand Embedment 40 LF $3.00 $120 31 4' dia. Manholes< 8' 1 EA $2,000.00 $2,000 32 4' dia. Manholes 8-1 O' 2 EA $2,400.00 $4,800 33 EA $2,550.00 $2,550 34 EA $5 ,500.00 $5,500 35 EA $600.00 $600 Subtotal $39,480 General $15,250 Total Water $61,570 Total Sanitary Sewer $39,480 TOTAL CONSTRUCTION! $116,3001 Engineering $6,500 TOTAL! $122,8001 CONSTRUCTION COST ESTIMATE 27-May-03 WATER AND SANITARY SEWER IMPROVEMENTS GRAHAM CORNER PLAZA COLLEGE STATION, TEXAS Item Estimated Unit Estimated No. Description Quantity Price Cost General 1 Mobilization/Layout 1 LS $5,000.00 $5,000 2 Site Preparation 0.5 AC $6,000.00 $3 ,000 3 Silt Fence 1,200 LF $2 .50 $3,000 4 Construction Exit-Rock 25 TONS $50.00 $1 ,250 5 Hydromulch/Hydroseeding 6,000 SY $0 .50 $3,000 Subtotal $15,250 Water Lines 6 12" Water PVC CL200 (C909) structural 50 LF $44.00 $2 ,200 7 12" Water PVC CL200 (C909) non-structural 480 LF $32.00 $15,360 8 8" Water PVC CL200 (C909) structural 130 LF $28.00 $3,640 9 8" Water PVC CL200 (C909) non-structural 760 LF $22 .00 $16,720 10 Connect To Existing Line 1 LS $500.00 $500 11 Replace Concrete Sidewalk -6' wide 150 SF $8 .00 $1 ,200 12 12" Gate Valves 2 EA $1 ,400.00 $2,800 13 8" Gate Valves 6 EA $650.00 $3,900 14 24"x 8" Tapping Sleeve & Valves EA $4,500.00 $4,500 15 12" x 8" M.J. Tees 2 EA $550.00 $1 , 100 16 8" M.J. Tees 2 EA $350.00 $700 17 8" x 6" M.J. Tees 2 EA $350.00 $700 18 12" M.J. Bends -45 deg. 2 EA $550.00 $1 , 100 19 8" M.J. Bends -45 deg. 2 EA $350.00 $700 20 8" M.J. Bends -22.5 deg. EA $350.00 $350 21 8" M.J. Bends -11.25 deg. 1 EA $350.00 $350 22 2" Blow off Assembly 3 EA $450.00 $1 ,350 23 Fire Hydrant Assembly 2 EA $2,200.00 $4,400 Subtotal $61,570 Sanitary Sewer Lines 24 8" SOR 26 Pipe -2241 -Structural 20 LF $38.00 $760 25 8" SOR 26 Pipe -3034 -Structural 530 LF $35.00 $18,550 26 8" SOR 26 Pipe -3034 -Non-Structural 30 LF $24.00 $720 27 6" SOR 26 Pipe -2241 -Structural 20 LF $36 .00 $720 28 6" SOR 26 Pipe -3034 -Structural 30 LF $32 .00 $960 29 6" SOR 26 Pipe -3034 -Non-Structural 100 LF $22 .00 $2,200 30 Cement Sand Embedment 40 LF $3 .00 $120 31 4' dia. Manholes < 8' 1 EA $2,000.00 $2,000 32 4' dia. Manholes 8-10' 2 EA $2,400.00 $4,800 33 4' dia. Manholes 8-1 O' wl watertight lid EA $2,550.00 $2,550 34 6' dia.Manhole 14-16' over exist line w/watertight lid EA $5,500.00 $5,500 35 Manhole Drop _,,,,,,,, EA $600.00 $600 --i\:. OF I ,, Subtotal $39,480 -~"" .......... t:-r. ' '~ ... ·· * ··.:IS' •• '· .. ... * ,, 'I!*: ··~ General $15,250 i............. . ................ ill Total Water $61,570 l ... m~.~r. . ... ~ .~ ..... 1 ,~. • Q:-Total Sanitary Sewer $39,480 1). 9 o··!iJI TOTAL CONSTRUCTIONj $116,3001 (:-00•.C}iSTt~«;.·~~ ~ Ss ••••••· N * Engineering $6,500 \\ 10N t,~. '<-'.,.._:::" TOTALJ $122,800j '"-~:~.l .. :. :;.~:"~'it. .. $,.z_7 ,03 TCEQ Office Use Only Notice of Intent (NOi) for Storm Water Discharges ----- -Associated with Construction Activity under the ·~ ~ TPDES Construction General Permit (TXR150000) TPDES Permit Number TXR1 5·:__·:__·:__·:__··-NO GIN Number: · · • · · · · · · · · · · · · · TCEQ For help completing this application. read lhe TXR 150000 NOi Instructions (TCE0-20022-lnslruclions). A. Construction Site Operator Customer Reference Number: CN _________ _ Name: C Mailing Address t 1v1 b v:.:vh?UYl J<.ood Country Mailing lnformati n if outside USA ) Territory: _________ Country ode: Postal Code: ___ _ Phone Number '1 1C, 0 -I\ Extension Fax Number {_q71 )b?O -9 71 7 E-mail Address I n-fv e ±e.xeo 1'\, V\eJ Type of Operator: 0 Individual 0 Sole Proprietorship -D.B.A. 0 Partnership (;8l.Corporation 0 Federal Government 0 State Government 0 County Government 0 City Government 0 Other:--------------------- Independent Operator? ~Yes 0 No Number of Employees 0 0-20 0 21-100 0 101-250 0 251-500 0 501 or higher Federal Tax ID 1 42.-. Lf-~4-'flff State Franchise Tax ID Number l]ALJtfj f<j(,.,11 DUNS Number: B. Name: __ -'-""'-"'-=>~-'--~ll-<:'4'-"1,-.i.e::::.i_~~~~~~~v-~.S:::_ _______ ~-~-----------~ Mailing Address City Col k.qe Sil:l-/-1CVl State li Zip Code J 7B4S- Country Mailing Information (if outside USA) Territory: Country eode: Postal Code: __ _ C. Project I Site Information 0 New 0 No Change Regulated Entity Reference Number: RN _________ _ Name G y-a__~ =tA Mailing Address: 2-State l_L Zip Code "719-/tS- Physical Address: a_ llt;ity: , ~ounty: k a 1:;0'::> Zip Code (]SjS" Location Access Description: 00 fil '2 West fuvvh:~,°be...J<d @Gv:a ~rYI k_d Latitude:~•~ •iflllei· N Longitude:~• Jld.' '1iJ3 W Degrees (0 ). Minutes('). and Seconds (") Latitude: Longitude: -Decimal Form Standard lnd~strial Cl ~sific~tio.~ (SIC) code Jfd23_ Also. describe the construction activity at this site (do not repeat the SIC code) · · ;ti · o w..x, ~ Co r6-trucl E' va::U _co V\fA fU..-W ~ D. Contact -lf).he TCE? ~eds _additional inf?rmation regarding this application, who s_hould_ be contacted? Name: UL<'~ Jm\-th -0oe. S~l..i.-l±::t. Title J?,r124~cl WkAX'\~eX Phone Number: cffo -ldJD;1 :1 \ \ Extension ?a~ Number: 17'1 '"' <-l 0 -q7q ] E-mail Address: E. Payment Information -Check I Money Order Number: Name on Check I Money Order: F. Certification I certify under penalty or law lhal this document was prepared under my direction or supervision in accordance with a system designed lo assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry or the person or persons who manage the system. or those persons directly responsible for gathering the information. the information submitted is. lo the best or my knowledge and belier. true. accurate. and complete. I am aware there are significant penalties for submitting false information. including the possibility of fine and imprisonment for knowing violations. Construction Site Operator: Prefix: m~~ First: Ca:;('e,...\ Middle: \) • Last: £m1_ _ SLmx: Titte:_1/~<4~e~~~'~J~e.A.~~F~----------- Signature: ~~ tY-d Date: _/_~_?_~_~_o_°3 _______ _ If you have questions on how to fill out this form or about the storm water program. please contact us at (512) 239-4671. Individuals are entitled lo request and review their personal information that the agency gath ers on its forms. They may also have any errors in their information corrected. To review such information, contact us at (512) 239-3282. TCE0-200/2 (05103) The completed NOi must be mailed to the following address . Use the attached document to submit the $100 application fee. Please note that the NOi and application fee are submitted separately to different addresses. Texas Commission on Environm ental Quality Storm Water & General Permits Team ; MC -228 P.O. Box 13087 Austin, Texas 787 11 -3087 Page 1 of ; Drainage Report for Graham Corner Plaza College Station, Texas July 2003 Developer: Ted Whi tn1er 2508 Merrimac Court College Station, Texas 77845 (979) 764-2667 Prepared By: TEXCON Genera] Contractors 1707 Graham Road College Station, Texas 77845 . (9 79) 690-7711 ' EVIEWED FO cn••o• '~ .,,... ... A G 0 7 2C03 COL&..cuc :> 1 "'1 • ENGINEERING CERTIFICATION 1, Joseph P. Schul tz, Licensed Professional Engineer No. 65889, State of Texas, certify that this repo rt for the drainage desi gn for th e Graham Corn er Plaza in College Station, Texas, was prepared by me in accordance with the provisions of the City of Coll ege Station Drainage Policy and Design Standards fo r the owners hereof, with the exception that storm water runoff detention is not be ing required for this project since the site discharges directly into an existing drainage and im ii1ediately into the l 00- year floodplain li mits. Jose~}lk TABLE OF CONTENTS GRAHAM CORNER PLAZA CERTIFICATIO ................................................................................................................................................................. I TABLE OF CONTENTS ....................................................................................................................................................... 2 LIST OF TABLES .................................................................................................................................................................. 2 INTRODUCTIO .................................................................................................................................................................. 3 GENERAL LOCA TIO AND DESCRIPTIO ................................................................................................................. 3 FLOOD HAZARD INFORMATlON ................................................................................................................................... 3 DEVELOPMENT DRAINAGE PATTERJ"lS ...................................................................................................................... 3 DRAI AGE DESIGN CRITERIA ....................................................................................................................................... 3 STORM WATER RUNOFF DETERMINATION .............................................................................................................. 4 STORM SE\VER CULVERT DESIGN ............................................................................................................................... 5 STORM SE\VER PIPE & INLET DESIG ........................................................................................................................ 5 CO CLUSIONS ..................................................................................................................................................................... 6 APPENDIX A ......................................................................................................................................................................... 7 Ca/c11/atio11s EXI-IIBIT A ........................................................................................................................................................................... 19 Time of Co 11ce11tratio11 Flow Patlr & Drai11age Area Map EXI-IIBlT B ........................................................................................................................................................................... 21 Pre-a11d Post-Developme11t Drainage Area Map EXI-IIBIT C ........................................................................................................................................................................... 23 Gradi11g Pfau LIST OFT ABLES TABLE l -Rainfall Intensity & Runoff Data .......................................................................................... 4 TABLE 2 -Time of Concentration (tc) Equations .................................................................................. 5 DRAINAGE REPORT GRAHAM CORNER PLAZA INTRODUCTION T he purpose of this report is to provide the hydro logical effects o f the construction of the infrastructure for the Graham Corn er Plaza proj ect, and to show that th e sto rm water runoff w ill be controlled in such a mann er so as to have minimal offsite or dow nstream im pact. GENERAL LOCATION AND DESCRIPTION T he proj ect is located on 10.73 acres lo cated in Col1 ege Stati on, Texas. Most of the site is open land with grass. A l.093 acre portion along the North Fork of Lick Creek is being ded icated to the City of College Station as greenway. This area is primarily wooded . The existing ground elevations range from elevation 276 to elevati o n 288. The general location of the project site is shown on th e vicinity map in Ex hi bit A. FLOOD HAZARD INFORMATION The project site is located in the Lick Creek Dra in age Basin . The site is located in a Zone X Area according to the Flood Insurance Rate Map (FIRM) prepared by the Federal Emergency Management Agency for Brazos County, Texas and incorporated areas dated Feb ruary 9, 2000, panel number 48041 C020 l D. Zone X Areas are dete1mined to be outside of the 500-yr fl oodplain. This site is not within the limit of study fo r the FIRM. However, the approx imate 100-year floodplain limits and the floodway were previously determined by Robertson Engineering fo r the City of College Stati on, and these limits were included on the Final Plat for th e project. T his floodplain area is also shown on Ex hibit A. Most of the floodplain area and all of the flood way for this tract is located in the Green ways Dedication Area. DEVELOPMENT DRAINAGE PATTERNS The storn1 water runoff from the site fl ows into the North Fo rk of Lick C reek. The runoff from this development will be discharged into the creek and the 100-year floodplain; therefore, no detention is required fo r this project. The drainage area boundaries are shown on Exhibit A. DRAINAGE DESIGN CRITERI A The design parameters fo r the storm sewer are as fo ll ows: • The Rational Method is utilized to determine peak storm water runoff rates fo r the sto1111 sewer design. • Design Storm Frequency Sto1111 cu lverts Sto1111 sewer system 25-year sto rm event I 0 and I 00-year s torms event s • Runoff Coefficients Undeveloped areas Developed areas Open space areas Impervious surfaces c = 0.30 c = 0.85 c = 0.40 c = 0.90 • Rainfall Intensity equations and valu es for Brazos County can be found in Table l . • Time of Concentration, tc -Calculations fo r are based on the method found in the TR- 55 publication. Refer to Appendix A for the equations and calculations. The drainage mnoff flow paths used for calculating the times of concentration for the design of Culvert No. l are shown in Exhibit B. For smaller drainage areas, a minimum tc of I 0 minutes is used to detem1ine the rainfall intensity values. STORM WATER RUNOFF DETERMINATION The peak runoff values were detem1ined in accordance with the criteria presented in the previous section for the l 0-, 25-and 100-year storm events. The runoff coefficients are based on the development of this tract. The drainage areas are shown in Ex hibit A. Runoff conditions are summarized in Table l. The time of concentration equations are shown in Table 2. TABLE 1 -Rainfall Intensity & Runoff Data Area c Area# (acres) c, C2 C3 Crotal A, A2 Al Total Area A 0.73 5.26 1.04 7.03 0.9 0.3 0.8 0.43 101 2.36 2.36 0.40 0.40 102 1.20 1.20 0.40 0.40 201 2.36 2.36 0.85 0.85 202 1.20 1.20 0.85 0.85 ---------203 0.23 0.23 0.90 0.90 ---------------··---204 0.23 0.23 0.90 0.90 -------------205 0.09 0.09 0.90 0.90 ---------206 0.10 0.10 0.90 0.90 -------------207 1.07 1.07 0.85 0.85 The Rational Method: Q=CIA I = b I (!c+d)0 Q = Flow (cfs) le= Time of concentration (min) A = Area (acres) C = Runoff Coeff. I = Rainfall Intensity (in/hr) Brazos County: 10 year storm b = 80 d = 8.5 e = 0.763 25 year storm b = 89 d = 8.5 e = 0.75 100 year storm b = 96 d = 8.0 e = 0.730 le (min) 17.8 10 10 10 10 10 -10 -10 -10 10 10 year storm 110 0 10 (in/hr) (cfs) 6.602 19.96 8.635 8.15 8.635 4.14 8.635 17.32 8.635 8.81 ----8.635 1.79 ----8.635 1.79 ----8.635 0.70 ----8.635 0.78 ----8.635 7.85 tc = L/(V*60) L = Length (ft) 25 year storm l2s 0 2s (in/hr) (cfs) 7.564 22.86 9.861 9.31 9.861 4.73 9.861 19.78 9.861 10.06 ----9.861 2.04 ----9.86 1 2.04 ---9.861 0.80 -9.86 1 0.89 --9.861 8.97 V = Velocity (ftfsec) 100 year storm 1100 0100 (in/hr) (cfs) 8.949 27.05 11.639 10.99 11.639 5.59 11.639 23.35 11.639 11 .87 ---11.639 2.41 11.639 2.41 11.639 0.94 11.639 1.05 l 1.639 10.59 TABLE 2 -Time of Concentration (tc) Equations Th e time of concentration was deterlllined using methods found in TR -55, ''Urb an Hydrology for Small Watersheds." The equations are as follows.· Time of Concentration: For Shallow Concentrated Flow: Tc = Tr(shccl llow) + T1(co11cc11lra1cd sheer llow) where: T, =Travel Time, minutes T, = L I (60*\1) where: T1 =travel time, minutes V =Velocity, fps (See Fig 3-l, App. E) L = flow length, feet Refer to Appendix A for calculations. STORM SEWER CULVERT DESIGN A storm sewer culvert is proposed at the State Highway 6 West Frontage Road driveway for this development. This culvert wi ll be designed for the 25-year storm event, and it w ill also pass the 100-year storm event without overtopping the driveway. Refer to Appendix A for the culvert calculator data sheets for the 25-and 100-year stom1 events. STORM SEWER PIPE & INLET DESIGN This project consists of the construction of the private driveway and storm sewer system and the public water and sanitary sewer lines for this development. No buildings or structures are proposed at this time. The private stom1 sewer system is designed to col lect the developed condition runoff from Lots 1, 2, 4 & 5, and discharge it into the North Fork of Lick Creek. Lots 3 & 6 will have separate storm sewer systems that wi ll discharge directly into the creek. The private driveway and the sto1m sewer curb inlets were designed for the existing conditions of the property. The storm sewer pipe system is designed for the future developed condition of the property. Pipes 1 & 2 will be constructed with the ends plugged until development of Lo ts 1, 4 or 5. Inlets and additional stom1 sewer piping will be required when the development plan for each lot is prepared. A drainage report shall be prepared for each lot before it is developed in order to verify that the calculated runoff values used in this report are not exceeded. As previously stated, the storm water runoff from this site will be collected by the proposed stonn sewer system and then flo w directly into the North Fork of Lick Creek. The storm sewer piping for this project has been selected to be Reinforced Concrete Pipe (RCP) meeting the requirements of ASTM C-76, Class III pipe meeting the requirements of ASTM C-789. The curb inl ets will be cast-in-place concrete. Appendix A presents a summary of the stom1 sewer inlet design parameters and calculations. The inlets were desi gned based on a l 0-year design storm . As per College Station guidelines, the capaciti es of inl ets in sump were reduced by I 0% to allow for clogging. [nlets were located to maintain a gutter !:low depth of 6" or less. This design depth will prevent th e spread of water from overtoppi ng th e curb of the road for th e 10-year sto1111 event. Refer to Appendix A for a summary of th e gutter !:low depths. The runoff intercepted by the proposed stonn sewer inlets was calculated using the fo llowing equations. The depth of Oow in the gutter was detem1ined by using the Straight Crown Flow equation. The capacities for the inlets in sump (inlets l & 2) were calculated using the inl ets in Sumps, Weir Flow equation with a maximum allowable depth o f 7" (5" gu tter !:low plus 2" gutter depression). These equations and the resulting data are also summari zed in Appendix A. There are no inlets on grade proposed for this development. Appendix A contains a summary of the stonn sewer pipe design parameters and calculations. All pipes are 18" in diameter or larger. The pipes for th e storm sewer system were designed based on the IO-year storm event, and th ey will also pass the 100-year storm event. Based on th e depth of !:low in the street determined for the 100-year storm event, this runoff will be contained within the street ri ght-of-way until it enters th e sto1111 sewer system. The velocity of !:low in the storm sewer pipe system is not lower than 2.5 feet per second, and it does not exceed LS feet per second. As the data shows, even during low !:low conditions, the velocity in the pipes will exceed 2.5 feet per second and prevent sediment build-up in the pipes. The maximum flow in the storn1 sewer pipe system wi ll occur in Pipe No. 4. The maximum velocity for the pipe system in this development will be 8.9 feet per second and w ill occur in Pipe No. 4. A concrete headwall is proposed for the end of Pipe 4 to dissipate the energy of the discharge and control erosion. Appendix A contains a summary of the pipe calc ulations as well as a summary of th e !:lows th rough th e storm sewer system for the l 0 and 100-year events. A grading plan for this site is provided as Exhibit C. The private driveway is designed so that it is above the base l:lood elevation for the North Fork of Lick Creek. The sit e will be graded so that if there is any flow that exceeds the capacity of the stonn sewer system it would flow over the private driveway curb and immediately enter the floodplain area. The outlet of Pipe 4 is below the Base Flood Elevation so there will be a tail water effect on the discharge of Pipe 4. However, due to the close proximity of this site to the stream channel and its location in the watershed, the peak runoff from this site will occur much sooner than the peak runoff for the stream . Therefore, the tailwater condition should have little effect on the capacity of the sto1m sewer pipe. As stated previously, the area adjacent to Storm Inlet 2 has been designed to allow excess runoff to flow directly into the l:loodpl ain area if the stom1 sewer pipes cannot carry the entire runoff from the site. This will limit the depth of water in the private drive during these circumstances. CONCLUSIONS The construction of this project will increase the storm water runoff from this site. However, the runoff will be carried through the proposed sto1111 sewer system and immed iately into th e l 00-year l:loodplain. The increased flow in this tributary should not have a signi ft cant impact on the surrounding property. No flood damage to downstream or adjacent landowners is ex pected as a result of thi s development. APPENDIX A Calculations 7 Graham Corner Plaza Existing Inlet A Bypass Calculations The Rational Method: Q =CIA Q = Flow (cfs) C = Runoff Coeff. I = Rainfall Intensity (in/hr) A = Area (acres) Area Inlet I I Total # A, A1 (acres) A o 74 1 0.24 1 o.98 c, 0.9 Top of curb= 1" lower than centerline of road Transverse (Crown) slope (fVft) = 0.0200 Straight Crown Flow (Solved to find actual depth of flow, y): Q = 0.56 • (z/n) • S112 • ys13 c:> Y ={QI [0.56 • (z/n) • S112]}31s (Eqn from C. of C.S. Design Standards, page 30; Design Procedures for Stra ight Crowns) n = Roughness Coefficient= 0.018 z = Reciprocal of crown slope = 50 S = StreeUGutter Slope (fVft) y = Depth of flow at inlet (ft) c 010 a,. 0100 s Y10 Y2s Y100 C2 Crotal (cfs) (cfs) (cfs) (ftlft) (ft) I (in) (ft) I (in) (ft) I 0.4 0.78 6.580 7.514 8.869 0.0050 o.348 I 4.17 o.366 I 4.39 o.389 I (in) 4.67 Capacity of Inlets on grade: Oc = 0.7 • (1/(H1 -H2)] • [H1 s12_ H2s12] Oc = Flow capacity of inlet (cfs) H1 =a+ y H2 = a= gutter depression (2" Standard; 4" Recessed) y = Depth of flow in approach gutter (ft) Standard Inlet length l = 15', a = 2" = 0.167' Oc10 Oc1oeypass Oc,. Oc2seypass Oc100 (cfs) (cfs) (cfs) (cfs) (cfs) 5.40 1.18 5.62 1.90 5.91 Oc1oOBypass (cfs) 2.95 Time of Concentration Calculations Drainage Area for Proposed Culvert No. 1 Flow along Pavement Segment #1: Flow length = 370' = L Slope = 0.8% For paved surface at 0.8%, Velocity V = 1.8 fps (see Fig. 3-1) T1 = L/(60*V) = 370' I (60* 1.8) = 3.4 minutes Flow along Pavement Segment #2: Flow length = 6 15 ' = L Slope = 1.2% For paved surface at 1.2%, Velocity V =2.2 fps (Fig 3-1) = 6 l 5' I ( 60*2.2) = 4. 7 minutes Flow along Pavement Segment #3: Flow length = 565' = L Slope = l.0% For paved surface at l .0%, Velocity V =2.0 fps (Fig 3-1) ~ = 565 ' I (60*2.0) = 4.7 minutes Flow thru Ditch Segment #4: (Refer to attached channel calcul ations) Trapezoidal channel with 1 :5 sides, Bottom width = 24" Flow length = 690' = L Slope= 0.45% (Note: slope & length estimated from topography.) n = 0.035 Area = 7.03 acres (Drainage Area A) Q25 = 22.86 cfs (using tc = l 7.8 minutes, C = 0.43) Upstream bypass from Existing Inlet A = l .90 cfs Total Q25 = 24.8 cfs From Manning's data, Velocity, V = 2.3 fps t1 = 300 sec= 5.0 minutes Tc= 3.4 + 4.7 + 4.7 + 5.0 = 17.8 minutes +-' 4--+-' 4- <lJ 0.. 0 V'I <lJ V'I I... :::J 0 u I... QJ .µ <I ::i: . 50 - . 20 - .10 .06 .04 - .02 - .01 -J I J I .005 I I J j j 0 .:..<u L-0' ~ <u ~ Q.,;-1 -::::i I I I I j I 2 J ' J j ' u ' I 4 I I , ' I !I j ,, I ' .I ..I I 6 j IJ r I J J J I I I I Ave ra ge ve l oc i t y, f t/sec J J ' , , . J , I I , I I 10 I FiKU~ :1-l.-,\veral(e vrlocitic!I ft'r C:"il im alinl( lrJvcl time for ~h allow conccntr.:ilrd now. (210· V[-TR-S5. Second Ed .. .June t98(i) -c 20 -; ' 1. ! ~ ' Ditch for Tc Calculations.txt channel calculator Given Input Data: Shape .......................... . Solving for .................... . Fl owrate ....................... . slope .......................... . Manning's n .................... . Height ......................... . Bottom width ................... . Left slope ..................... . Right slope .................... . computed Results: Depth .......................... . velocity ....................... . Full Fl owrate .................. . Fl ow area ...................... . Flow perimeter ................. . Hydraulic radius ............... . Top width ...................... . Area ........................... . Perimeter ...................... . Percent full ................... . Trapezoidal Depth of Flow 24.9000 cfs 0.0045 ft/ft 0.0350 24.0000 in 24.0000 in 0.2000 ft/ft (V/H) 0.2000 ft/ft (V/H) 15.4741 in 2.2858 fps 71. 5805 cfs 10.8932 ft2 181. 8058 in 8. 6280 fo 178. 7413 in 24.0000 ft2 268.7529 in 64.4755 % Page 1 Graham Corner Plaza Pipe & C I C I u vert alcu at1ons Inlet Outlet 10-year storm 100-year storm Pipe# Size Length Slope 0 100 Invert Elev Invert Elev 0 10 V 10 Travel Time, tn 0 V100 Travel Time, tnoo % Full % Full (in) (ft) (%) (ft) (ft) (cfs) (fps) (sec) (min) (cfs) (fps) (sec) (min) 1 18 45 .3 1.20 282.54 282.00 7.85 6.6 63.7 7 0.11 10.59 6.9 81 .2 7 0.11 -----------· --------------·-------2 30 191 .5 0.70 277.62 276.28 25.17 7.2 67.0 27 0.44 33.93 7.3 89.8 26 0.44 ---------------------------- - 3 36 25.5 0.70 275.78 275.60 36.47 7.9 61 .9 3 0.05 49.16 8.3 77.7 3 0.05 ----------4 36 80.3 0.80 275.50 274.86 39 03 8.5 61 .9 9 0.16 52.61 8.9 77.8 9 0.15 Culvert Data 25-year storm 100-year storm 2x24 48.0 0.50 282.14 281.90 24.80 39 -12 0.21 30.00 4.8 -10 0.17 Culvert No. 1 Top of Road= 284.85 Headwater = 284.36 Headwater= 284.59 In let 1 Pipe 2 0 10 Areas 101, 102, 203, 205 = 14.78 0 10 Area 201 , 207 = 25.17 0 25 Areas 101, 102, 203, 205 = 16 .88 0 25 Are a 201 , 207 = 28.75 0 100 Areas 101 , 102, 203, 205 = 19.93 0 100 Area 201 , 207 = 33.93 Inlet 2 Pipe 3 0 10 Areas 204, 206 = 2.56 0 10 Areas 201 , 202, 203, 205, 207 = 36A7 025 Areas 204, 206 = 2.93 0 25 Areas 20 1, 202, 203, 205, 207 = 41.65 0 100 Areas 204, 206 = 3.46 0 100 Areas 201 , 202, 203, 205, 207 = 49.16 ~ Pipe 4 0 10 Area 207 = 7.85 0 10 Areas 201 thru 207 = 39.03 0 25 Area 207 = 8.97 0 25 Areas 201 thru 207 = 44.58 0 100 Area 207 = 10.59 0 100 Areas 20 1 thru 207 = 52 .61 Culvert No. 1 0 2s Area A, Bypass from Inlet A = 24.8 0 100 Area A, Bypass from Inlet A = 30.0 Pipe 1 -10 Year Storm Manning Pipe Calculator Given Input Data: Shape .......................... . Solving for .................... . Diameter ....................... . Flowrate ....................... . Slope .......................... . Manning' s n .................... . Computed Results: Depth .......................... . Area .......................... , . Wetted Area .................... . Wetted Perimeter ............... . Perimeter ...................... . Velocity ....................... . Hydraulic Radius ............... . Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Circular Depth of Flow 18.0000 in 7.8500 cfs 0.0120 ft/ft 0.0140 11.4659 in 1.7671 ft2 1.1879 ft2 33.2699 in 56.5487 in 6.6083 fps 5.1415 in 63.6992 % 10.6850 cfs 6.0465 fps Pipe 1 -100 Year Storm Manning Pipe Calculator Given Input Data: Shape .......................... . Solving for .................... . Diameter ....................... . Flowrate ....................... . Slope .......................... . Manning's n .................... . Computed Results: Depth .......................... . Area ........................... . Wetted Area .................... . We tted Perimeter ............... . Perimeter ...................... . Velocity ....................... . Hydraulic Radius ............... . Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Graham Corner Plaza Col lege Station, Texas Circular Depth of Flow 18.0000 in 10.5900 cfs 0.0120 ft/ft 0. 0140 14.6100 in 1.7671 ft2 1.5363 ft2 40.3883 in 56.5487 in 6.8931 fps 5.4775 in 81.1667 % 10.6850 cfs 6.0465 fps Pipe 2 -10 Year Storm Manning Pipe Calculator Given Input Data : Shape .......................... . Solving for .............. .' ..... . Diameter ....................... . Flowrate ....................... . Slope .......................... . Manning's n .................... . Computed Results: Depth .......................... . Area ....................... · · · .· · Wetted Area .................... . Wetted Perimeter ............... . Perimeter ...................... . Velocity ....................... . Hydraulic Radius ............... . Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Circular Depth of Flow 30.0000 in 25.1700 cfs 0.0070 ft/ft 0 .0140 20.1101 in 4 .9087 ft2 3 .4980 ft2 57.5529 in 94 .2478 in 7.1955 fps 8.7522 in 67.0336 % 31.8662 cfs 6 .4917 fps Pipe 2 -100 Year Storm Manning Pipe Calculator Given Input Data: Shape .......................... . Solving for .................... . Diameter ....................... . Flowrate ....................... . Slope .......................... . Manning ' s n .................... . Computed Results: Dept h .......................... . Area ........................... . Wetted Area .................... . Wetted Perimeter ............... . Perimeter ...................... . Ve locity ....................... . Hydraulic Radius ............... . Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Graham Corner Plaza College Stat ion, Te~as Circular Depth of Flow 30 .0000 in 33.9300 cfs 0 .0070 ft/ft 0. 0140 26 .9374 in 4.9087 ft2 4.6454 ft2 74.7349 in 94.2478 in 7.3040 fps 8.9508 i n 89.7912 % 31.8662 cfs 6.4917 fps Pipe 3 -10 Year Storm Manning Pipe Calculator Given Input Data: Shape . . . . . . . . . . . . . . . ...... . Solving for . . . . . . . . . ...... . Diameter ................... . Flowrate ....................... . Slope .......................... . Manning's n .. Computed Results: Depth ....... . Area ........ . Wetted Area ..... . Wetted Perimeter Perimeter ...... . Velocity .. Hydraulic Radius Percent Full .... Full flow Flowrate Ful l flow vel ocity Circular Depth of Flow 36.0000 in 36.4700 cfs 0.0070 ft/ft 0.0140 22 .2742 in 7.0686 ft2 4.5927 ft2 65.1795 in 113. 0973 in 7.9408 fps 10.1466 in 61 .8728 % 51.8179 cfs 7.3307 fps Pipe 3 -100 Year Storm Manning Pipe Calculator Given Input Data: Shape ....... . Sol ving for ..... . Diameter . . . . . . . . . . ..... . Flowrate ................... . Slope .......................... . Manning's n ..... Computed Results: Depth .......... . Area ............... . Wetted Area .... . Wetted Perimeter Perimeter . . . . . . . . ..... . Ve l ocity . . . . . . . . . ......... . Hydraulic Radius ...... . Percent Full . . . . . ..... . Full flow Flowrate ......... . Full flow velocity ......... . Gr aham Corner Plaza Co ll e g e S tati o n, Te xas Circular Depth of Flow 36.0000 in 49.1600 cfs 0.0070 ft/ft 0. 0140 27.9742 in 7.0686 ft2 5.8936 ft2 77 .6919 in 113.0973 in 8.3412 fps 10.9237 in 77 .7062 % 51.8179 cfs 7.3307 fps Pipe 4 -10 Year Storm Manning Pipe Calculator Given Input Data: Shape .............. . Solving for ........ . Diameter .......... . Flowrate ........ . Slope ........ . Manning 's n .. . Computed Results : Depth ....... . Area ........ . Wetted Area .. Wetted Perimeter .. Perimeter ...... . Velocity ........ . Hydraulic Radius . Percent Full ..... Full flow Flowrate Full flow velocity Circular Depth of Flow 36.0000 in 39.0300 cfs 0.0080 ft/ft 0 .0140 22.2902 in 7.0686 ft2 4.5966 ft2 65.2126 in 113.0973 in 8.4910 fps 10.1501 in 61.9174 % 55.3957 cfs 7.8369 fps Pipe 4 -100 Year Storm Manning Pipe Calculator Given Input Data: Shape .............. . Solving for ........ . Diameter ...... . Flowrate ................ . Slope ........... . Manni ng's n ... . Computed Results: Depth ....... . Area ........ . Wetted Area .. Wetted Perimeter .......... . Perimeter ............... . Velocity ....................... . Hydraulic Radius .......... . Percent Full ............. . Full flow Flowrate ..... . Full flow velocity ....... . Gra ham Co rner Plaza Co ll ege Stc1tion, Te:-:as Circular Depth of Flow 36.0000 in 52.6100 cfs 0.0080 ft/ft 0. 0140 28.0020 i n 7.0686 ft2 5.8994 ft2 77.7587 in 113. 0973 in 8.9179 fps 10.9250 in 77.7834 % 55.3957 cfs 7.8369 fps Culvert 1 -25 Year Storm Culvert Calculator Entered Data: Shape ..... . Number of Barrels Solving for . . .............. . Chart Number . . . . . . ............ . Scale Number ..... Chart Description Scal e Description Ov ertopping ..... . Flowrate ........ . Manning's n ........... . Roadway Elevati on ..... . Inl et Elevation ....... . Outlet Elevation Diameter ...... . Length ....... . Entrance Lo ss . Tailwater ... Computed Results: Headwater ............ . Slope ........... . Velocity ............. . Circ ular 2 Headwater 1 3 CONCRETE PIPE CULVERT; NO BEVELED RING ENTRANCE GROOVE END ENTRANCE. PIPE PROJECTING FROM FILL Off 24 .8000 cf s 0.0140 284.8500 ft 282. 1400 ft 281.9000 ft 24.0000 in 48.0000 ft 0.2000 2.0000 ft 284.3570 ft Outlet Control 0 .0050 ft/ft 3 .9470 fps Culvert 1 -100 Year St orm Culvert Calculator Entered Data: Shape ............ . Number of Barrels . Solving for ...... . Chart Number ..... . Scale Number .... . Chart Description Scale Description Overtopping ............ . Flowrate ........ . Manning's n ..... . Roadway Elevation Inlet Elevation . Outlet Elev ation Diameter . . . . . . . ....... . Length ......................... . Entrance Loss .. Tailwater ..... . Compu ted Results: Headwater Slope ...... . Velocity ..... . Graham Corner Plaza Co llege Station, Texa s Circular 2 Headwater 1 3 CONCRETE PIPE CULVERT ; NO BEVELED RING ENTRANCE GROOVE END ENTRANCE , PIPE PROJECTING FROM FILL Off 30.0000 cfs 0 .0140 284.8500 ft 282.1400 ft 28 1 .9000 ft 24 .0000 in 48.0000 ft 0 .2000 2.0000 ft 284.5919 ft Inlet Co ntrol 0.0050 ft/ft 4.774 6 fps Graham Corner Plaza Inlet Length Calculations Inlet# 1 2 Inlets 1 & 2 Inlets In Sump Length Flow from A c a,o Ocarry over Area# (acres) (cfs) (cfs) from inlet# 101, 102 3.56 0.4 12.30 -15' -203, 205 0.32 0.90 2.49 - 5' 204 0.23 0.9 1.79 -------·------206 0.10 0.9 0.78 - 20' Total Length 0 100 = 23.38 cfs Y100 = 0.533 ft= 6.40 in Transverse (Crown) slope (ft/ft) = 0.0200 Straight Crown Flow (Solved to find actual depth of flow, y): Q = 0.56 • (z/n) • S112 • y8'3 Q y ={Q I [0.56 * (z/n) * S112]}318 n = Roughness Coefficient = 0.013 S = StreeVGutter Slope (ft/ft) y = Depth of flow at inlet (ft) Capacity of Inlets on grade: Oc = 0.7 * [1/(H1 -H2)] * [H1 512-H2 512] Oc = Flow capacity of inlet (cfs) H, =a+ y H2 = a = gutter depression (2" Standard; 4" Recessed) y = Depth of flow in approach gutter (ft) 10 year storm 100 year storm C Total Or o1a1+10•;. (cfs) (cfs) 12.30 13.53 -- 2.49 2.74 1.79 1.97 -------0.78 0.85 Y 10-.actual gutter depth L10-Req'd* L10-ac1ual 0100 O carry over (ft) (in) (ft) (ft) (cfs) (cfs) from inlet# 0.311 3.73 16.57 -------12.18 15 ----- 0.171 2.05 3.35 - 0.151 1.81 2.11 5 2.41 -------------0.110 1.33 1.05 - *using y,....~ = 7" = 0.583' z = Reciprocal of crown slope 50 Inlets in sumps, Weir Flow: L = Q I (3 • y312) Q y = (Q I 3L)213 L = Length of inlet opening (ft) Q = Flow at inlet (cfs) y =total depth of flow on inlet (ft) max y for inlet in sump= 7" = 0.583' OTotal O rotal•10% (cfs) (cfs) 16.57 18.23 3.35 3.69 2.41 2.65 ------1.05 1.15 Y 100-inlet (ft) (in) 0.619 7.43 0.401 4.81 EXHIBIT A Time of Concentration Flow Path & Drainage Area Map l l) EXHIBIT B Pre-and Post-Development Drainage Area Map 21 EXHIBIT C Grading Plan