GENERAL
MINIMUM SUBMITTAL REQUIREMENTS:
*$1
932 Site Plan Application Fee.
350 Non -Residential Architectural Standards Building Review Application Fee (if applicable).
600 (minimum) Development Permit Application / Public Infrastructure Review and Inspection Fee. Fee is
% of acceptable Engineer's Estimate for public infrastructure, $600 minimum (if fee is > $600, the balance is
due prior to the issuance of any plans or development permit).
Application completed in full. This application form provided by the City of College Station must be used
and may not be adjusted or altered.
Fourteen (14) folded copies of site plan.
❑ One (1) folded copy of the landscape plan. NV
One (1 copy of the following for Non -Residential Architectural Standards building review or Northgate
Buil g Review (if applicable).
Building elevations to scale for all buildingsc:i)
VA list of building materials for all facade and screening.
❑ Color samples for all buildings or list colors to be used from the approved color palette.
❑ Electronic copy of Site Plan e-mailed to csuelectdesign@cstx.gov.
M/Two (2) copies of the grading, drainage, and erosion control plans with supporting drainage report.
❑ Two (2) copies of the Public infrastructure plans and supporting documents (if applicable). N�/0'
❑ Traffic Impact Analysis or calculations of projected vehicle trips showing that a TIA is not necessary for the
proposed request (if applicable). 4,0-
❑ The attached Site Plan Non -Residential Architectural Standards Building Review and Northgate Building
Review checklists s applicable) with all items checked off or a brief explanation as to why they are not
check off.
Date of Optional Preapplication or Stormwater Management Conference
NAME OF PROJECT DUTCK G4,yeE 14oar,-.F-oAJ
`< l�fiZ�i �o�/� 4X'V6041V
ADDRESS / 35/ 54.eL etb0o0e A466wAY
ybc GaLLEIP-
5f/f7_-vb^J _y3( 77 VrS
LEGAL DESCRIPTION (Lot, Block, Subdivision)
4.o7' OlVe &Lock pLt
HAAe ��rJt:E 5u?cr✓+-STn�✓
APPLICANT/PROJECT MANAGER'S INFORMATION
(Primary contact for the project):
Name Vgt3AN &o"51-'2uc.Toes .T.
ye- E-mail
SCot/ciL°yrh4rlGonS�iVcforS. �^
Street Address / 0 3 2Q LAKE )eo e?t3
SLJ-Cr # / c7/
City Ho05TZ,-./
State iEXRS
Zip Code 770 ZO
Phone Number Z91- 3-/0- (a68'7
Fax Number
391 51- 4R.A4
PROPERTY OWNER'S INFORMATION:
Name -rwX ln4ze6gS
E-mail
If!,VgrS/ t ,y
- 0O t V fir+). ceM
y
Street Address / 3 5 / BheL RV40oEe2
Fe6WIAM Soury
City eoLLeGE Srs4i- biy
State 719)(45
Zip Code 77845
Phone Number 977 - /P ?Y- 20 2;1
Fax Number
`777 - /043 - 35-Y/
1i11 Pagel 011
ARCHITECT OR ENGINEER'S INFORMATION:
Arrv: Ses4.v &,K
Name Ardt Gofo V--n,+V COX J%le. E-mail bCo�cq, Cc
Street Address NlARtQc&*t' 67ek2 , SurTE .250
City HOVS7oN State 7,FJG49 Zip Code '77s37
Phone Number 7/3'797-Oyr,y Fax Number 7/3--7U-4,7yo
OTHER CONTACTS (Please specify type of contact):
Name
Street Address
City
Phone Number
Current zoning (.. G
State
Fax Number
E-mail
Zip Code
Present use of property C44 /JCAGEQS NAP To--4VC4.v46 A27%* AA-lo SEeyZZiL
Proposed use of property 4Q0. ion/FtL
Number of parking spaces required SuPFxs3 --Number of parking spaces proposed kX40,46 eEe:-viOl
Is there Special Flood Hazard Area (Zone A or Zone AE on FEMA FIRM panels) on the property? r Yes )(No
This information is necessary to help staff identify the appropriate standards to review the application and will be used ti
help determine if the application qualifies for vesting to a previous ordinance. Notwithstanding any assertion made,
vesting is limited to that which is provided in Chapter 245 of the Texas Local Government Code or other applicable law.
Is this application a continuation of a project that has received prior City platting approval(s) and you are requesting the
application be reviewed under previous ordinance as applicable?
r Yes
06o
yes, provide information regarding the first approved application and any related subsequent applications (provide
iditional sheets if necessary):
Project Name:
City Project Number (in known):
Date / Timeframe when submitted:
1/11 Page 2 of 11
MULTI -FAMILY RESIDENTIAL
Total Acreage
Floodplain Acreage
Housing Units
# of 1 Bedroom Units
# of 2 Bedroom Units
# of 3 Bedroom Units
# of 4 Bedroom Units
FOR 2 BEDROOM UNITS ONLY
# Bedrooms = 132 sq. ft.
PARKLAND DEDICATION
(Fees due prior to the issuance of a Building Permit)
# of Multi -Family Dwelling Units
X$1646=$
# of acres in floodplain
# of acres in detention
# of acres in greenways
Date dedication approved by Parks &
Recreation Advisory Board
COMMERCIAL
Total Acreage
Building Square Feet
# Bedrooms < 132 sq. ft.
Floodplain Acreage
* Projects that were vested prior to January 1, 2008, per Chapter 245 of the Texas Local Government
Code may be assessed a different amount. Please contact city staff for additional information.
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true
and correct.
,.� 46 ' Y
Signature and ti le
SIcT L/.
1104AI& m6e 1- v/,�
U.e,S?N -Ze-
O!>• /S'• �rY
Date
1/11 Page 3 of 11
CERTIFICATIONS REQUIRED FOR ALL DEVELOPMENT
Owner Certification:
1. No work of any kind may start until a permit is issued,
2. The permit may be revoked if any false statements are made herein.
3. If revoked, all work must cease until permit is re -issued.
4. Development shall not be used or occupied until a Certificate of Occupancy is issued.
5. The permit will expire 0 no significant work is progressing within 24 months of issuance,
6. Other permits maybe required to fulfill local, state, and federal requirements. Owner will obtain or show
compliance with all necessary State and Federal Permits prior to construction including NOI and SWPPP.
7, If required, Elevation Certificates will be provided with elevations certified during construction (forms at slab pre -
pour) and post construction.
8. Owner hereby gives consent to City representatives to make reasonable inspections required to verify
compliance.
g. If, stormwater mitigation is required, including detention ponds proposed as part of this project, it shall be
designed and constructed first in the construction sequence of the project.
10, in accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken
to insure that ail debris from construction, erosion, and sedimentation shall not be deposited in city streets, or
existing drainage facilities. Ali development shall be in accordance with the plans and specifications submitted to
and approved by the City Engineer for the above named project, All of the applicable owes and ordinances of the
City of College Station shall apply.
11. The information and conclusions contained in the attached plans and supporting documents will comply with the
current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified
Design Guidelines Technical Specifications, and Standard Details. Al development has been designed in
accordance with all applicable codes and ordinances of the City of College Station and State and Federal
Regulations.
12, Release of plans to (name or firm) is authorized forbidding purposes
only. I understand that final approval and release of plans and development for construction its contingent on
contractor signature on approved Development Permit.
13. I, THE OWNER,'AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS FOR
THE DEVELOPMENT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE, AND
ACCU TE. 1 /
e" Aliylr
Property Ow {s) Date ��—�
Engineer Certification: VVVV
1, The project has been designed to ensure that stormwater mitigation, including detention ponds, proposed as part
of the project will be constructed first in the construction sequence.
2. 1 will obtain or can show compliance with al necessary Local, State and Federal Permits prior to construction
including NOI and SWPPP. Design will not preclude compliance with TPDES: i.e., projects over 10 acres may
require a sedimentation basin.
3. The information and conclusions contained in the attached plans and supporting documents comply with the
current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified
Design Guidelines. Ail development has been designed in accordance with all applicable codes and ordinances
of the City of College Station and State and Federal Regulations.
4, 1, THE ENGINEER, AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS
FOR THE DEVELOPMENT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE, AND
ACCURATE.
Engineer Date
1111 Pegg 4 of 11
CERTIFICATIONS REQUIRED FOR ALL DEVELOPMENT
Owner Certification:
1. No work of.any kind may start until a permit is issued.
2. The permit may be revoked if any false statements are made herein.
3. If revoked, all work must cease until permit is re -issued.
4. Development shall not be used or occupied until a Certificate of Occupancy is issued.
5. The permit will expire If no significant work is progressing within 24 months of issuance.
6. Other permits may be required to fulfill local, state, and federal requirements. Owner will obtain or show
compliance with all necessary State and Federal Permits prior to construction including NOI and SWPPP.
7. If required, Elevation Certificates will be provided with elevations certified during construction (forms at slab pre -
pour) and post construction.
8. Owner hereby gives consent to City representatives to make reasonable inspections required to verify
.compliance.
9. If, stormwater mitigation is required, including detention ponds proposed as part of this project, it shall be
designed and constructed first in the construction sequence of the project.
10. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken
to insure that all debris from construction, erosion, and sedimentation shall not be deposited in city streets, or
existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to
and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the
City of College Station shall apply.
11. The information and conclusions contained in the attached plans and supporting documents will comply with the
current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified
Design Guidelines Technical Specifications, and Standard Details. All development has been designed in
accordance with all applicable codes and ordinances of the City of College Station and State and Federal
Regulations.
12. Release of plans to (name orfirm) is authorized for bidding purposes
only. I understand that final approval and release of plans and development for construction is contingent on
contractor signature on approved Development Permit.
13. I, THE OWNER, AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS FOR
THE DEVELOPMENT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE, AND
ACCURATE.
Property Owner(s) Date
Engineer Certification:
1. The project has been designed to ensure that stormwater mitigation, including detention ponds, proposed as part
of the project will be constructed first in the construction sequence.
2. 1 will obtain or can show compliance with all necessary, Local, State and Federal Permits prior to construction
including NO[ and SWPPP. Design will not preclude compliance with TPDES: i.e., projects over 10 acres may
require a sedimentation basin.
3. The information and Conclusions contained in the attached plans and supporting documents comply with the
current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified
Design Guidelines. All development has been designed in accordance with all applicable codes and ordinances
of the City of College Station and State and Federal Regulations.
4. I, THE ENGINEER, AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS
-FOR THE D VEL PMENT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE, AND
AC,
' lths/P psti� �P� 6-19'-0201,2,
Engin er Date
1111 Page 4 of 11
The following CERTIFICATIONS apply to development in Special Flood Hazard Areas.
Required for Site Plans, Final Plats, Construction Plans, Fill / Grading Permits, and Clearing Only
Perm its:*
A. I, certify, as demonstrated in the attached drainage study, that the
alterations or development covered by this permit, shall not:
(i) increase the Base Flood elevation;
(ii) create additional areas of Special Flood Hazard Area;
(iii) decrease the conveyance capacity to that part of the Special Flood Hazard Area that is not in the floodway
and where the velocity of flow in the Base Flood event is greater than one foot per second. This area can
also be approximated to be either areas within 100 feet of the boundary of the regulatory floodway or
areas where the depth of from the BFE to natural ground is 18 inches or greater;
(iv) reduce the Base Flood water storage volume to the part of the Special Flood Hazard Area that is beyond
the floodway and conveyance area where the velocity of flow in the Base Flood is equal to and less than
one foot per second without acceptable compensation as set forth in the City of College Station Code of
Ordinances, Chapter 13 concerning encroachment into the Special Flood Hazard Area; nor
(v) increase Base Flood velocities.
beyond those areas exempted by ordinance in Section 5.11.3a of Chapter 13 Code of Ordinances.
Engineer Date
Initial
71 * If a platting -status exemption to this requirement is asserted, provide written justification under separate
letter in lieu of certification.
Required for Site Plans, Final Plats, Construction Plans, and Fill / Grading Permits:
M
certify to the following:
(i) that any nonresidential or multi -family structure on or proposed to be on this site as part of this application is
designed to prevent damage to the structure or its contents as a result of flooding from the 100-year storm.
Engineer Date
Additional certification for Floodway Encroachments:
C. I, , certify that the construction, improvement, or fill covered by this
permit shall not increase the base flood elevation. I will apply for a variance to the Zoning Board of Adjustments.
Engineer
Date
1111 Page 5 011
Required for all projects proposing structures in Special Flood Hazard Area (Elevation Certificate
required).
Residential Structures:
D. I, , certify that all new construction or any substantial improvement
of any residential structure shall have the lowest floor, including all utilities, ductwork and any basement, at an
elevation at least one foot above the Base Flood Elevation, Required Elevation Certificates will be provided with
elevations certified during construction (forms at slab pre -pour) and post construction.
Engineer / Surveyor
Commercial Structures:
E. I,
Date
certify that all new construction or any substantial improvement
of any commercial, industrial, or other non-residential structure are designed to have the lowest floor, including all
utilities, ductwork and basements, elevated at least one foot above the Base Flood Elevation
Engineer / Surveyor Date
OR
I, , certify that the structure with its attendant utility, ductwork,
basement and sanitary facilities is designed to be flood -proofed so that the structure and utilities, ductwork,
basement and sanitary facilities are designed to be watertight and impermeable to the intrusion of water in all
areas below the Base Flood Elevation, and shall resist the structural loads and buoyancy effects from the
hydrostatic and hydrodynamic conditions.
Required Elevation Certificates will be provided with elevations certified during construction (forms at slab pre -
pour) and post construction.
Engineer / Surveyor
Conditions or comments as part of approval:
Date