HomeMy WebLinkAboutStaff Comments(*/" CITY OF COLLEGE STATION Home ofT=AcW Oniwnity• MEMORANDUM May 30, 2013 TO: Travis Martinek, Smiling Mallard Development, Ltd.; via email: travis@clarkewyndham.com FROM: Morgan Hester, Staff Planner SUBJECT: INDIAN LAKES PH 16 (PP) -Preliminary Plat Staff reviewed the above -mentioned preliminary plat as requested. All of Staffs comments have been addressed and your project will be placed on the June 6, 2013 Planning and Zoning Commission meeting at 7:00p at City Hall, located at 1101 Texas Avenue South, College Station, Texas. The agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://www.cstx.gov/pz If you have any questions or need additional information, please call me at 979.764.3570. cc: Kevin McClure, McClure & Browne Engineering/Surveying, Inc., via email: kevinm@mcclurebrown.com Gary Arnold, Brazos County Planning & Traffic, via fax 775.0453 Case file #13-00900065 Pkxxixg &Deve%pmmt Services P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77942 TEL. 979.764.3570 • FAX. 979.764.3496 a tc.govidevservims (*/" CITY OF COLLEGE STATION Ho. ofTz A4M UW.v iry' MEMORANDUM April 16, 2013 TO: Travis Martinek, Smiling Mallard Development, Ltd.; via email: travis@clarkewyndham.com FROM: Morgan Hester, Staff Planner SUBJECT: Indian Lakes Ph 16 - Preliminary Plat Staff reviewed the above -mentioned preliminary plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. Once all comments have been addressed and the following information submitted by 10:00 a.m. on any Monday, your project will be placed on the next available Planning and Zoning Commission meeting: One (1) 24'k36' copy of the revised preliminary plat, Thirteen (13) 11"x17" copies of the revised preliminary plat, One (1) copy of the digital file of the preliminary plat on diskette or e-mail to AsdioitalsubmittalO,cstx. goy Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. If all comments have not been addressed your project will not be scheduled for a Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. htto://www. cstx. q oy/DZ If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments cc: Kevin McClure, McClure & Browne Engineering/Surveying, Inc., via email: kevinm@mcclurebrown.com Gary Arnold, Brazos County Planning & Traffic, via fax 775.0453 Case file #13-00900065 P/aeeixg&D.4.pm Snv . P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77942 TEL. 979.764.3570 • FAX. 979.764.3496 atcgov/Aevsenrices Staff Review Comments — No. 1 Indian Lakes Ph 16 PP—13-00900065 PLANNING 1. Pease add the missing line label on Mesa Verde to ensure that the boundaries close. 2. Please revise the 'Location Within Indian Lakes' map to show the actual boundaries of Indian Lakes Subdivision so that it reflects what is shown in the 'Vicinity Map'. 3. Please provide the lot and block information of the abutting Indian Lakes Subdivision and Deer Park Subdivision properties. 4. Please remove all Certificates from the plat as this is preliminary and they are not required until the Final Plat. 5. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not been made aware of will constitute a completely new review. Review by: Morgan Hester Date: April 11, 2013 ENGINEERING COMMENTS NO. 1 1. Please show all required PLIES including the 10-ft rear lot PLIES. 2. Please show the 10-ft rear lot PLIES on the adjacent Phase 2 lots. 3. The fire hydrants can be near the intersection of two waterlines, but cannot be at the intersection as shown. Please revise. 4. Please label the waterline sizes on the culdesacs. 5. Please add a note indicating that all structures must be within 500-ft of a fire hydrant as measured along the right-of-way. 6. Please provide a letter from Wellborn SLID indicating their intent to serve this phase and verifying capacity. Reviewed by: Erika Bridges Date: April 15, 2013 ADDRESSING 1. Please propose a new street name for Apache Creek Cove and Black Hawk Cove . The names, or a similar street name, already exists in College Station, Bryan, and/or the County. Please go to the following web site for a list of street names that already exist, and therefore, cannot be used. http://www.brazos9l l.dst.tx.us/msag/ Reviewed by: Michael Reeves (Brazos County 911) Date: April 11, 2013 COUNTY COMMENTS 1. Reference the correct date and version of FEMA Flood Insurance Rate Map in Note 2. 2. Depict all P.LI.E.'s which are described in Note 4 on the plat drawing. Also depict 25' building setback from each street (this includes side lot setback to Mesa Verde Drive for Lots 1, 4, 5, 8). 3. Provide Public Drainage Easement for Maintenance of Cross -Culvert Channels (size will vary depending on channel and number of proposed conduits) (See pencil mark-up). 4. Provide Cross -Culvert at Apache Cove and a separate Cross -Culvert for those flows under Mesa Verde Drive. (Red -Lined) 5. Provide all Approval's from City of College Station. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 3 6. Schedule a Pre -Design Conference between Developer, Consultant and County Engineer staff prior to development of Construction Plans. Reviewed by: Alan Munger, PE and Gary Arnold Date: April 15, 2013 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. This project location is outside of CSU certification area. CSU will not provide electric service to this project location. GENERAL ELECTRICAL COMMENTS 1. To discuss any of the above electrical comments please contact Gilbert Martinez at 979.764.6255. Reviewed by: Gilbert Martinez SANITATION 1. Sanitation is ok with this project. Reviewed by: Wally Urrutia Date: April 11, 2013 Date: April 15, 2013 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3 of 3 (* F"" CITY OF COLLEGE STATION Home of Te Ae4M UW.v iry' MEMORANDUM May 20, 2013 TO: Travis Martinek, Smiling travis@clarkewyndham.com FROM: Morgan Hester, Staff Planner Mallard Development, Ltd.; via email: SUBJECT: INDIAN LAKES PH 16 (PP) -Preliminary Plat Staff reviewed the above -mentioned preliminary plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. Once all comments have been addressed and the following information submitted by 10:00 a.m. on any Monday, your project will be placed on the next available Planning and Zoning Commission meeting: Memo transmittal showing both Staff's comments and applicant's response, One (1) 24" x 36" copy of the revised Preliminary Plat, Thirteen (13) 11" x 17" copies of the revised Preliminary Plat. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. If all comments have not been addressed your project will not be scheduled for a Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. htto://www. cstx. q oy/DZ If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments cc: Kevin McClure, McClure & Browne Engineering/Surveying, Inc., via email: kevinm@mcclurebrown.com Gary Arnold, Brazos County Planning & Traffic, via fax 775.0453 Case file #13-00900065 PLm.ixg&Developm Services P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77942 TEL. 979.764.3570 • FAX. 979.764.3496 csa.gov/Aevservices STAFF REVIEW COMMENTS NO. 2 Project: INDIAN LAKES PH 16 (PP) - 13-00900065 PLANNING The boundaries for this plat do not close. Please revise. Per Michael Reeves, Brazos County 911, if Yuma Crossing is being used in another phase, Yuma Cove cannot be used. Reviewed by: Morgan Hester Date: May 14, 2013 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next toansmittal lette, and "bubbled' on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new temew. 2 of 2