Loading...
HomeMy WebLinkAboutStaff Comments4 CITY OP COLLFiGE STATION Horne ofTexar A&M University' T, R N r"TWIT19-011111N January 25, 2013 TO: Ben Dimmitt; via: ben@chiocodesign.com FROM: Jason Schubert, AICP Principal Planner SUBJECT: NAPA FLATS (SP — MINOR/NRA) Thank you for the submittal of your SITE PLAN - COMMERCIAL and NON-RESIDENTIAL ARCHITECTURE STANDARDS application. This project will be distributed to staff next week for their review. cc: Rick Ramsey; via: u51�5 . Case file no. 13-00900017 (SP) Case file no. 13-00900018 (NRA) Planning 6, Development Services P.O. BOX 9960 • 1101 'R':XA3 AVENUE, • COLLF(IF S I'ArtON • 1TNAS • 77g�$, ITT. 979.764.3570 • FAX. 979.704-3496 cstx.gov/devservices (* F4" CITY OF COLLEGE STATION Homr ofT AdM U.ro ,,• MEMORANDUM January 24, 2013 TO: FROM: Jason Schubert, AICP Principal Planner SUBJECT: NAPA FLATS (SP—MINOR/NRA) Thank you for the submittal of your SITE PLAN - COMMERCIAL and NON-RESIDENTIAL ARCHITECTURE STANDARDS application. This project will be distributed to staff next week for their review. cc: Case file no. 13-00900017 (SP) Case file no. 13-00900018 (NRA) Pkxxing &Deve%pmmt Service P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77942 TEL. 979.764.3570 • FAX. 979.764.3496 csa.go idmervims GENERAL ELECTRICAL COMMENTS 1. All electrical is existing and based on previous plans submitted no additional electrical will be required. 2. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 1.30.13 SANITATION 1. Need to show dumpster that they will be using, or a dumpster pad on their site. Reviewed by: Wally Urrutia Date: February 1, 2013 (*/" CITY OF COLLEGE STATION Horn ofT. A4M UahsNry' 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM TO: FROM: Lauren A. Hovde, AICP, Staff Planner SUBJECT: Napa Flats — Minor Site Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: City of College Station Transmittal Letter, Memo providing written responses to all of staff's comments (identify the specific page that each comment was addressed on or the reason for not addressing the comment), Seven (7) complete sets of site civil construction documents for the proposed development with the revised site and landscaping plans attached (one set will be returned to you, please submit additional copies if you want more than one approved set), Two (2) revised site plans, One (1) landscaping plan, One (1) 11x17 grading and erosion control plan, _ Easement Dedication Sheet and required documents (please note that the Site Plan will not be stamped approved until the Blanket Easement, or all other appropriate easements, have been dedicated to the City of College Station). OR Four (4) revised site and one (1) landscaping plan, $ Parkland Dedication fees prior to issuance of a building permit, _ Easement Dedication Sheet and required documents (please note that the Site Plan will not be stamped approved until the Blanket Easement, or all other appropriate easements, have been dedicated to the City of College Station). Plaeeixg&D.4.pm S.v P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77842 TEL. 979.764.3570 • FAX. 979.764.3496 atcgov/Aevsenrices Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please contact Teresa Rogers at 979.764.3570. Attachments: Staff review comments PC: Case file #13-00900017 STAFF REVIEW COMMENTS NO. 1 Project: Napa Flats (Sp - Minor) — 13-00900017 PLANNING 1. Please add the total square footage of all outdoor seating, total land area of the subject lot, property legal description, zoning information for the subject and abutting properties, north arrow, property legal description, and parking calculation that includes the indoor and outdoor restaurant and waiting areas. 2. Building plot note.... 3. Parking agreement 4. Provide a general note on the site plan that all roof and ground -mounted mechanical equipment shall be screened from view or isolated so as not to be visible from any public right-of-way or residential district within 150' of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. 5. Provide a general note on the site plan that states the following: Exterior building and site lighting will meet the standards of Section 7.10 of the Unified Development Ordinance. The light source shall not project below an opaque housing and no fixture shall directly project light horizontally. Fixtures will be mounted in such a manner that the projected cone of light does not cross any property line. 6. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not be made of aware of will constitute a completely new review. Reviewed by: Lauren A. Hovde, AICP, Staff Planner Date: February 1, 2013 ENGINEERING COMMENTS NO. 1 1. Please include a note indicating the minimum, average, and maximum domestic water and sanitary sewer demands. 2. If the building is required to have a fire sprinkler system, a public waterline will need to be extended to the serve the site. An engineer will need to provide a plan & profile drawing as well as a cost estimate for the public waterline. Reviewed by: Erika Bridges Date: 2/4/13 ENGINEERING COMMENTS NO. 2 1. (Repeat) Please include a note indicating the minimum, average, and maximum domestic water and sanitary sewer demands. Based on the provided demands, please label your water meter size. 2. (Repeat) If the building is required to have a fire sprinkler system, a public waterline will need to be extended to the serve the site. An engineer will need to provide a plan & profile drawing as well as a cost estimate for the public waterline. - The fire line and FDC need to be shown on the site plan. - The FDC will need to be located along a fire lane and no more than 150 feet from a fire hydrant. 3. Fire Line Plan Comments - Provide a detail for the area where the public water connection is proposed. This should show surrounding utilities, easements, right-of-way line, sidewalk, etc. - A profile sketch showing the connection to the existing waterline, depth of connection, valve placement, etc. needs to be submitted. - It appears that the existing waterline is located under the sidewalk. This permit will need to include repair of the sidewalk to match existing sidewalk. Notes and standard details for sidewalk repair must be included. - Please submit a cost estimate for the proposed public fire line, isolation valve, and other repairs in the public ROW. (Please note that if greater than $20,000 a professional engineer must prepare & seal plans.) - Since the waterline connection is proposed within the TxDOT ROW along Texas Ave., please submit a TxDOT Utility Permit Application. (FYI... There is an existing 8" waterline within the parking lot in front of Spec's and Kohl's. If you were able to tie onto that line, TxDOT permits and sidewalk/ROW repair would not be necessary.) - The proposed valve adjacent to the tap will need to be noted as an isolation valve, meaning the line beyond valve to the building will be privately owned and maintained. - Please add note on the plans that the fire suppression line shall have a lockable lid on the isolation valve. The lockable lid shall supply the same protection as the AMP or USA, LL562 Locking Lid at a minimum. An alternate lockable lid shall be approved by College Station Utilities Director or his designee. Reviewed by: Erika Bridges Date: February 22, 2013 (*/" CITY OF COLLEGE STATION Hom ofT. A&M UahsNry' 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM TO: FROM: Jason Schubert, AICP, Principal Planner SUBJECT: Napa Flats (SP - Minor) - Site Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: City of College Station Transmittal Letter _ Two (2) complete sets of site civil construction documents for the proposed development with the revised site plan attached, and Four (4) revised site plans. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Case file #13-00900017 P/aeeixg&D.4.pm Snv . P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77842 TEL. 979.764.3570 • FAX. 979.764.3496 atcgov/Aevsenrices STAFF REVIEW COMMENTS NO. 2 Project: Napa Flats (SP - Minor) - 13-00900017 PLANNING 1. I have no further comments regarding the proposed site plan. 2. 1 have no further comments regarding the proposed building elevations. 3. Please note that any changes made to the plans that have not been requested by the City of College Station must be explained in your next transmittal letter and "bubbled" on your plans. Reviewed by: Jason Schubert Date: February 22, 2013 Page 2 of 2 STAFF REVIEW COMMENTS NO. 2 Project: Napa Flats (SP - Minor) - 13-00900017 PLANNING 1. 1 have no further comments regarding the proposed site plan. 2. 1 have no further comments regarding the proposed building elevations. 3. Please note that any changes made to the plans that have not been requested by the City of College Station must be explained in your next transmittal letter and "bubbled" on your plans. Reviewed by: Jason Schubert Date: February 22, 2013 ENGINEERING COMMENTS NO. 2 1. (Repeat) Please include a note indicating the minimum, average, and maximum domestic water and sanitary sewer demands. Based on the provided demands, please label your water meter size. 2. (Repeat) If the building is required to have a fire sprinkler system, a public waterline will need to be extended to the serve the site. An engineer will need to provide a plan & profile drawing as well as a cost estimate for the public waterline. - The fire line and FDC need to be shown on the site plan. - The FDC will need to be located along a fire lane and no more than 150 feet from a fire hydrant. 3. Fire Line Plan Comments - Provide a detail for the area where the public water connection is proposed. This should show surrounding utilities, easements, right-of-way line, sidewalk, etc. - A profile sketch showing the connection to the existing waterline, depth of connection, valve placement, etc. needs to be submitted. - It appears that the existing waterline is located under the sidewalk. This permit will need to include repair of the sidewalk to match existing sidewalk. Notes and standard details for sidewalk repair must be included. - Please submit a cost estimate for the proposed public fire line, isolation valve, and other repairs in the public ROW. (Please note that if greater than $20,000 a professional engineer must prepare & seal plans.) - Since the waterline connection is proposed within the TxDOT ROW along Texas Ave., please submit a TxDOT Utility Permit Application. (FYI ... There is an existing 8" waterline within the parking lot in front of Spec's and Kohl's. If you were able to tie onto that line, TxDOT permits and sidewalk/ROW repair would not be necessary.) - The proposed valve adjacent to the tap will need to be noted as an isolation valve, meaning the line beyond valve to the building will be privately owned and maintained. - Please add note on the plans that lockable lid on the isolation valve. protection as the AMP or USA, LL56 2 Reviewed by: Erika Bridges Date: February 22, 2013 CITY Oh COI.UGL STATION Home ofTexol A&M Unioershp` 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM February 6, 2013 TO: Ben Dimmitt via email: ben@chiocodesign.com FROM: Lauren A. Hovde, AICP, Staff Planner SUBJECT: Napa Flats — Minor Site Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: City of College Station Transmittal Letter; Memo providing written responses to all of staff's comments (identify the specific page that each comment was addressed on or the reason for not addressing the comment); Seven (7) complete sets of site civil construction documents for the proposed development with the revised site and landscaping plans attached (one set will be returned to you, please submit additional copies if you want more than one approved set); Two (2) revised site plans. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please contact Teresa Rogers at 979.764.3570. Attachments: Staff review comments PC: Rick Ramsey via postal mail Case file #13-00900017 Planning d Development Services P.O. BOX9960 • 1101 'r'EXAS AVENUE • COLLEGE STAEION - TEXAS • 77842 TEL 979.764.3570 • PAX. 979.764.349E cstx.gov/devservices STAFF REVIEW COMMENTS NO. 1 Project: Napa Flats (SP - Minor)—13-00900017 PLANNING 1. Please add the total square footage of all outdoor seating, total land area of the subject lot, property legal description, zoning information for the subject and abutting properties, north arrow, property legal description, and parking calculation that includes the indoor and outdoor restaurant and waiting areas. 2. Please add a note that this site is with the Culpepper Plaza building plot when considering landscaping, signage, and Non -Residential Architectural Standards. 3. Provide a general note on the site plan that all roof and ground -mounted mechanical equipment shall be screened from view or isolated so as not to be visible from any public right-of-way or residential district within 150' of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. 4. Provide a general note on the site plan that states the following: Exterior building and site lighting will meet the standards of Section 7.10 of the Unified Development Ordinance. The light source shall not project below an opaque housing and no fixture shall directly project light horizontally. Fixtures will be mounted in such a manner that the projected cone of light does not cross any property line. 5. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not be made of aware of will constitute a completely new review. Reviewed by: Lauren A. Hovde, AICP, Staff Planner Date: February 1, 2013 ENGINEERING COMMENTS NO. 1 1. Please include a note indicating the minimum, average, and maximum domestic water and sanitary sewer demands. 2. If the building is required to have a fire sprinkler system, a public waterline will need to be extended to the serve the site. An engineer will need to provide a plan & profile drawing as well as a cost estimate for the public waterline. Reviewed by: Erika Bridges Date: February 4, 2013 GENERAL ELECTRICAL COMMENTS 1. All electrical is existing and based on previous plans submitted no additional electrical will be required. 2. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: January 30, 2013 SANITATION 1. Need to show dumpster that they will be using, or a dumpster pad on their site. Reviewed by: Wally Urrutia Date: February 1, 2013 (* 01F,41 CITY OF COLLEGE STATION Home of Te A6M Uxivmiiy- 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM February 6, 2013 TO: Ben Dimmitt via email: ben@chiocodesign.com FROM: Lauren A. Hovde, AICP, Staff Planner SUBJECT: Napa Flats— Minor Site Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: City of College Station Transmittal Letter, Memo providing written responses to all of staffs comments (identify the specific page that each comment was addressed on or the reason for not addressing the comment), Seven (7) complete sets of site civil construction documents for the proposed development with the revised site and landscaping plans attached (one set will be returned to you, please submit additional copies if you want more than one approved set), Two (2) revised site plans. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please contact Teresa Rogers at 979.764.3570. Attachments: Staff review comments PC: Rick Ramsey via postal mail Case file #13-00900017 Planing &Deve%pmmt Services P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77842 TEL. 979.764.3570 • FAX. 979.764.3496 csa.gov/Aevservims STAFF REVIEW COMMENTS NO. 1 Project: Napa Flats (SP - Minor) — 13-00900017 PLANNING 1. Please add the total square footage of all outdoor seating, total land area of the subject lot, property legal description, zoning information for the subject and abutting properties, north arrow, property legal description, and parking calculation that includes the indoor and outdoor restaurant and waiting areas. 2. Please add a note that this site is with the Culpepper Plaza building plot when considering landscaping, signage, and Non -Residential Architectural Standards. 3. Provide a general note on the site plan that all roof and ground -mounted mechanical equipment shall be screened from view or isolated so as not to be visible from any public right-of-way or residential district within 150' of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. 4. Provide a general note on the site plan that states the following: Exterior building and site lighting will meet the standards of Section 7.10 of the Unified Development Ordinance. The light source shall not project below an opaque housing and no fixture shall directly project light horizontally. Fixtures will be mounted in such a manner that the projected cone of light does not cross any property line. 5. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not be made of aware of will constitute a completely new review. Reviewed by: Lauren A. Hovde, AICP, Staff Planner Date: February 1, 2013 ENGINEERING COMMENTS NO. 1 1. Please include a note indicating the minimum, average, and maximum domestic water and sanitary sewer demands. 2. If the building is required to have a fire sprinkler system, a public waterline will need to be extended to the serve the site. An engineer will need to provide a plan & profile drawing as well as a cost estimate for the public waterline. Reviewed by: Erika Bridges Date: February 4, 2013 GENERAL ELECTRICAL COMMENTS 1. All electrical is existing and based on previous plans submitted no additional electrical will be required. 2. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido SANITATION 1. Need to show dumpster that they will Reviewed by: Wally Urrutia Date: January 30, 2013 be using, or a dumpster pad on their site. Date: February 1, 2013 (*/" CITY OF COLLEGE STATION Nome ofTe Ae4M UW.v iry' 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM February 22, 2013 TO: Ben Dimmitt, Chioco Design, via: ben(r),chiocodesign.com FROM: Jason Schubert, AICP, Principal Planner SUBJECT: Napa Flats(SP- Minor) - Site Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: City of College Station Transmittal Letter Two (2) complete sets of site civil construction documents for the proposed development with the revised site plan attached, and Four (4) revised site plans. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Rick Ramsey, via: rick.ramsevQbrixmoor.com Case file #13-00900017 Nm.ixg eb D.4.pmens Services P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77842 TEL. 979.764.3570 • FAX. 979.764.3496 a tcgmidevsenrices STAFF REVIEW COMMENTS NO. 2 Project: Napa Flats (SP - Minor) - 13-00900017 PLANNING 1. I have no further comments regarding the proposed site plan. 2. 1 have no further comments regarding the proposed building elevations. 3. Please note that any changes made to the plans that have not been requested by the City of College Station must be explained in your next transmittal letter and "bubbled" on your plans. Reviewed by: Jason Schubert Date: February 22, 2013 ENGINEERING COMMENTS NO. 2 1. (Repeat) Please include a note indicating the minimum, average, and maximum domestic water and sanitary sewer demands. Based on the provided demands, please label your water meter size. 2. (Repeat) If the building is required to have a fire sprinkler system, a public waterline will need to be extended to the serve the site. An engineer will need to provide a plan & profile drawing as well as a cost estimate for the public waterline. - The fire line and FDC need to be shown on the site plan. - The FDC will need to be located along a fire lane and no more than 150 feet from a fire hydrant. 3. Fire Line Plan Comments - Provide a detail for the area where the public water connection is proposed. This should show surrounding utilities, easements, right-of-way line, sidewalk, etc. - A profile sketch showing the connection to the existing waterline, depth of connection, valve placement, etc. needs to be submitted. - It appears that the existing waterline is located under the sidewalk. This permit will need to include repair of the sidewalk to match existing sidewalk. Notes and standard details for sidewalk repair must be included. - Please submit a cost estimate for the proposed public fire line, isolation valve, and other repairs in the public ROW. (Please note that if greater than $20,000 a professional engineer must prepare & seal plans.) - Since the waterline connection is proposed within the TxDOT ROW along Texas Ave., please submit a TxDOT Utility Permit Application. (FYI... There is an existing 8" waterline within the parking lot in front of Spec's and Kohl's. If you were able to tie onto that line, TxDOT permits and sidewalk/ROW repair would not be necessary.) - The proposed valve adjacent to the tap will need to be noted as an isolation valve, meaning the line beyond valve to the building will be privately owned and maintained. - Please add note on the plans that the fire suppression line shall have a lockable lid on the isolation valve. The lockable lid shall supply the same protection as the AMP or USA, LL562 Locking Lid at a minimum. An alternate lockable lid shall be approved by College Station Utilities Director or his designee. Reviewed by: Erika Bridges Date: February 22, 2013