Loading...
HomeMy WebLinkAboutFolder, FOR OFFICE USE ONl P&Z CASE NO.: () 0 A TE SUBMITrED:~~t.11- FINAL PLAT APPLICATION (check one) Minor _Amending v" Final _Vacating _Replat The following items must be submitted by an established filing deadline date for P & Z Conunission consideration. MINIMUM SUBMITTAL REQUIREMENTS: _L Filing Fee of $200.00. _L Development Permit Application Fee of $100.00 (if applicable). ~ Infrilst.ructure Inspection Fee of $300.00 {applicable if any public infrastructure is being constructed.). _f_ Application completed in full. _L_ Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.) -Ji/__ One (1) copy of the approved Preliminary Plat and/or one (1) Master Plan (if applicable). ~Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. ~ A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. _./_Two (2)copies of public infrastructure plans associated with .~ plat (if applicable). APPLICATION DATA -\ME OF SUBDIVISION 5k, t:Dtt2t $J,Ji11t~'o-I\ 1 ]).,ab(.. 3 .~ECIFIED LOCATION OF PROPOSED SUBDIVISION S>..J:h ~ 6~~ yr~r-;.t.EJ 1 .R a.7f-~f ~o.U. \k')l,,,""'1 " I No\'-!h ~f 9~blL Crttk ~ S: APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name 1!.Xl.on Ge.nfr'J Co(\ ir~? ... \Joe SchJh. e.E I Jl ' I { f g_J I I Street Address j101 Gv-4.baW\-Rc1 ./ City (pV:O 2t 9-Vt State 1°X Zip Code ]12;245 E-Mail Address JDt.uli.vJ.f-~@ fekl.Drt .. n('f Phone Number lf 1'f ... b 10 ... T7 \I Fax Number -4-q~11+-.,,,,__,ltL-1'1-'<-0_-~tf-'-J '[...._.1,___ _____ _ PROPER1Y OWNER'S INFORMATION: Name Jo\v\lzWl Tuvt'7fovJ? Ivie.-· Street Address ll\oo C.owH-.i.eru.1 1 ~. City __.,G_,._o ...... k"'--'-¥mM=--------- State JX Zip Code :J{p0?ft E-Mail Address ----------- Phone Number q ( 5 · ~i..$ -14 zA Fax Number 115 .,,,,(p 1..5 _. ":412 ARCIIlTECT OR ENGINEER'S INFORMATION: Name f~"' ... Jot 5c.Ju,Jh... p.e. Street Address IM 6..-~'JU. 7 City {.oUe'f f:tJ..'17:::><] State f 'f. Zip Code 112'45 E-Mail Address j~ sJiu.ih@. f tuort. n.t f Phone Number j1q ~1D-]1 rl Fax Number °/Jq,,.. {plfO -C/?Cf Z FINAL PLAT APPLICATION FNLPAPP.DOC Jnsm l ofJ -.. TOTAL ACRES OF SUBDIVISION l2 .ZS R-0-W ACREAGE 2 · 2..2.. TOTAL# OF LOTS _ _.4_...I __ TUMBER OF LOTS BY ZONING DISTRICT 4-( I &\'P? I I AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DI-STRICT: o:z..31 R'~ / 1 1 __ FLOODPLAIN ACREAGE 0 . 0 PARKLAND DEDICATION ACREAGE OR FEE AMOUNT ---------- A STATEMENT ADDRESSING ANY DIFFERENCES BE1WEEN 1HE FINAL PLAT AND APPROVED MASTER DEVELOPMENT PLAN AND/OR PRELIMINARY PLAT (IF APPLICABLE): A REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME_N_,_:f Pt _____ _ REQUESTEDOVERSIZEPARTICIPATION---4:::..ff..!...------------------- TOTAL LINEAR FOOTAGE OF PROPOSED: 111.S I STREETS 1010' SIDEWALKS ,,_ 73 I SANITARY SEWER LINES l'f l1 1 WATERLINES o CHANNELS --~..,---176' STORM SEWERS --~O~_BIKE LANES I PATIIS NOTE: DIGITAL COPY OF PLAT (IF APPLICABLE) MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attache( hereto are true, correct and complete. The undersigned hereby requests approval by the City. of College Statio1 of the above identified final plat. 3-z_o-ol Date FINAL PLAT APPLICATION 2 of) VNT PA PP l'VV' , M< ""° 't!)rrr-tl.:6-0-("' '1 :3o ~ SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION ~plication is hereby made for the following development specific sitelwateIWay alterations: S4 &i'4,·'6\W1 ~b1a stn.t.~ ~%'tr1A.cli'e-vt ACKNOWLEDGMENTS: I, j 0 r;_ _,b h ti/ be r.J , design engineer/owner, hereby acknowledge or affinn that: - The information and conclusions contained in the above plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a con · · of approval of this permit application, I agree to construct the improvements proposed in this application according to and the req · ments of Chapter 13 of the College Station ity Code. CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.) A I, , certify that any nonresidential structure on or proposed to be on this site as part of this application is design.~,ted to prevent damage to the structure or its contents as a result of flooding from the 100 year stonn. Engineer Date I, , certify that the finished floor elevation of the lowest floor, including any ..ement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Haz.ard Study and maps, as amended. Engineer Date c. I, Joserk ? r sc.W -r~ , certify that the alterations or development covered by this permit shall not diminish the flood-canying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning encroachments of lloodways and oflloodway ~ \~P-~ 1-zo .. of Engineer r Date D. I, ~~ P. $ c..k.\. h , do certify that the proposed alterations do not raise the level of the 100 year flood above elevatio establis in the latest Federal Insurance Administration Flood Haz.ard Study. Engineer Date Conditions or comments as part of approval:----------------------------- .xordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris rrom construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. FINAL PLAT APPLICATION 3 of3 Jnrl.JJ DA.DD TV'\I"" "lMC:/00 I «~ DEVELOPMENT PERMIT PERMIT NO. 03-(01 )00028 Project: STONE FOREST PH 3 C.Olll<il STATION FOR AREAS OUTSIDE THE SPECIAL FLOOD HAZARD AREA RE: CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: STONEFORESTPHASE3 DATE OF ISSUE: 03/28/03 OWNER: JOHNSON INVESTMENTS INC P 0 BOX 800 COLEMAN , TX 76834 TYPE OF DEVELOPMENT: SPECIAL CONDITIONS: SITE ADDRESS: 300 GREENS PRAIRIE ROAD DRAINAGE BASIN: Lick Creek VALID FOR 9 MONTHS CONTRACTOR: TEX CON Full Development Permit All construction must be in compliance with the approved construction plans All trees must be barricaded, as shown on plans, prior to any construction . Any trees not barricaded will not count towards landscaping points. Barricades must be 1' per caliper inch of the tree diameter. The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria. If it is determined the prescribed erosion control measures are ineffective to retain all sediment onsite, it is the contractors responsibility to implement measures that will meet City, State and Federal requirements. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used for temporary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetation be returned to its original condition , placement and state. The Owner and/or Contractor shall be responsible for any damage to adjacent properties, city streets or infrastructure due to heavy machinery and/or equipment as well as erosion, siltation or sedimentation resulting from the permitted work. Any trees required to be protected by ordinance or as part of the landscape plan must be completely fenced before any operations of this permit can begin. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction , erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development of an area outside the special flood hazard area. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit application for the above named project and all of the codes and ordinances of the City of College Station that apply. Date 2 / '31311 0 3 r·· Date ·' ·,'· AE·PA 0 . : Dear Operator: U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA) NATIONAL POLLUTANT DISCHARGE ELJMINATJON SYSTEM (NPDES) STORM WATER. NOTICE OF INTENT CENTER TXR10MX15 &EPA 12/0612000 The EPA has processed your Notice of Intent (NOI) application for the facility noted below. Thls facility is authorized to discharge storm water associated with construction activity u.nder the terms and conditions impesed by the EPA's NP-DES Storm Water Construction Permit. The facility permit number is listed above and the active date of pennit coverage is 1119/2000. EPA's construction permit requires certain pollution prevention and control measures. Among the conditions and requirements of this permit, you must prepare and implement a pollution prevention plan (PPP) that is tailored to your construction site. As a facility authorized to discharge under this storm water construction permit, all terms and conditions must be complied with to maintain coverage and avoid possible penalties. .. • en CD :::J r+ CD '< .. -l m >< (") 0 :z (0 -.J (0 Cll (0 0 (0 -.J (0 -.J ;;:: ID , ' I\) CD ,, FACllJTY: OPERATOR: \ b STONEGA TE SUBDIVISION TEXCON GENERAL CONTRACTORS ~~ w 200 GREENS PRAlRlE RD 1707 GRAHAM RD \~ CD COLLEGE ST A TION, TX COLLEGE ST A TION, TX ;:. ~ ~-·. ·~· ~· ~-~· . .-.;N ___ ,_,.;,._,,.,'"-1-7l45--.. ~~-'""'---'"'-'"-···;..>~C•«""'-'-•'--~~"-·; ..... ~~---;-,,,.~~'--···-"·"·-~;-~.,".~'--'~;.~; .. _,~--~, .. ~.---··;--· . -· ;118.~----~--· . ·,,....,,..'-.>.;-'-'-'-'-'~'·"--~;-~.·-r·'~·--····-;, .... ~ •.. ; ......... ,,;.,,._v_••W·'·-*-·-·,. ~ To obtain a oopy of the EPA's storm water construction permit terms and conditions to which you are now held accountable, please call the EPA Office of Water Resource Center at (202) 260-7786. If you have general questions concerning the storm water program, please call the EPA Region 06 contact: Brent Larsen, (214) 665-7523. If you have questions about this form, contact the Notice of Intent Center at (301) 495-4145. -u ID (Q CD I\) --1\) J.E. STEVENS CO . 9156253672 P.02 • J.E. STEVENS COMPANY .~ l February 14, 2002 Mr. Ted Mayo Assistant City Engineer P.O. Box 9960 College Station, Texas 77842 Re: Stone Forest Dear Mr. Mayo, "SERVING YOUR PERSONAL AND BUSINESS NEEDS" : JOE & JANET JOHNSON tWJ/J ~ ~,_,,. .. ,a.a/,' ~..u'm.us; ~--T6~N 915-62!5·2124 We as developers of Stone Forest have been cont~cted by Joe Schultz with Texcon to update you on the status of Phase II. We appji d for Phase H permit in March 2001, in retrospect this was done too early. We had so ma y problems getting Phase I permit approved that we anticipated the same problems Ith phase II. We did not have any problems with Phase II permit but the weather delayed us f6ur months in completing phase I. Phase II is over 60% completed. Underground water, sewer1:nd storm drainage systems are totally completed. · I Due to 9-11 many projects were put on hold to e ~aluate what the economic impact might be. We postponed further development of Phase II un !I the first quarter of 2002 to see if 9-11 would effect the real estate sales in the Brya :-College Station area. We felt the impact of 9-11 for several months as did other de ietopers and real tors in your area . We I. have contacted Texcon and have stated we would 1ke Phase II to be completed . I by May 15th. They have informed us that we co Id have this project completed in 60-75 days. ' We are dedicated to Stone Forest and the city of pllege Station to complete this subdivision as soon as possible and make this one of the pretti '.st developmenrs in your area. We \\-ill finish all landscaping and fences as promised to mutually benefit the residents of Stone Forest and Pebble Creek. Please call us at 979-229-0310 if y ~ have any questions. ~~~ Joe Johnson J cc: Texcon Joe Schultz .. . .J.t:.. :::>lt:.Vt:.NS CU. '51156253672 P.01 F DATE: J.-/ t/-tJ :L. TO:_Al;t . J..to( Jttc o FROM:~:c"\'1.-> i-vu..c:.t Cf I 5-b J. .) --3 h 'l J,. -· TOTAL NU!vIBER OF PAGES: DOCUMENTS: ( , ~ ... CONSTRUCTION COST ESTIMATE 19-Apr-O 1 STONE FOREST SUBDIVISION COLLEGE STATION, TE XAS PHASE 3 -41 LOTS Item Estimated Unit Estimated No. Description Quantity Price Cost Sitework Mobilization/Layout (entire phase three) LS $5,000.00 $5,000.00 2 Erosion Control/Seeding LS $6,000.00 $6 ,000.00 3 Site Preparation 2.5 AC $7,000.00 $17,500.00 4 Topsoil Stripping & Replacement 1, 170 CY $4.00 $4,680.00 5 Excavation/Grading 3,510 CY $3.00 $10 ,530.00 6 Lime Stabilized Subgrade 6,800 SY $3.00 $20,400.00 7 Concrete Laydown Curb 3,590 LF $7.00 $25 , 130.00 8 Base Material -6" depth 5,400 SY $6.00 $32,400.00 9 Asphalt Paving - 1 1 /2" depth 5,400 SY $4.75 $25,650.00 10 Concrete Aprons 550 SF $5.00 $2 ,750.00 11 Sidewalks 4,340 SF $2 .75 $11 ,935.00 12 ADA Ramps 2 EA $400.00 ~800.00 Subtotal $162,775.00 Storm Drainage 13 Drainage Pipe -18" RCP -structural 0 LF $36.00 $0.00 14 Drainage Pipe -18" RCP -non-structural 290 LF $26.00 $7,540.00 15 Drainage Pipe -24" RCP -structural 165 LF $42.00 $6,930.00 16 Drainage Pipe -24" RCP -non-structural 315 LF $32.00 $10,080.00 17 Inlets 5' wide/junction boxes 1 EA $2,250.00 $2,250.00 18 Inlets 1 O' wide 2 EA $2 ,800.00 ~5,600 .00 Subtotal $32,400.00 Water Lines 19 6" Water PVC CL200 (C900) structural 125 LF $24.00 $3,000.00 20 6" Water PVC CL200 (C900) non-structural 215 LF $18.00 $3,870.00 21 8" Water PVC CL200 (C900) structural 1,220 LF $28.00 $34,160.00 22 8" Water PVC CL200 (C900) non-structural 370 LF $20.00 $7,400.00 23 Gate Valves -6" 1 EA $550.00 $550.00 24 Gate Valves -8" 3 EA $600.00 $1,800.00 25 M.J. Bends/Reducers -8" 8 EA $300.00 $2,400.00 26 M.J. Tees -8" 4 EA $300.00 $1,200.00 27 Tapping Sleeve & Valve 18" x 8" 1 EA $12,000.00 $12,000.00 28 Water Services 20 EA $700.00 $14,000.00 29 Water Tie-in at existing stub out 4 EA $500.00 $2,000.00 30 2" Blow off Assembly EA $400.00 $400.00 31 Fire Hydrant Assembly 2 EA $2,000.00 ~4,000.00 Subtotal $86,780.00 Page 1 of 2 ' ' Sanitary Sewer Lines 32 8" SOR 26 Pipe -structura l 65 LF $28 .00 $1 ,820.00 33 8" SOR 26 Pipe -non-structu ral 425 LF $22 .00 $9,350.00 34 8" ASTM 2261 pressure pipe -stru ctural 40 LF $32.00 $1,280.00 35 8" ASTM 2261 pressure pipe -non-struct 0 LF $24.00 $0.00 36 6" SOR 26 Pipe -structura l 160 LF $24.00 $3,840.00 37 6" SOR 26 Pipe -non-stru ctu ral 1,000 LF $18.00 $18,000.00 38 Sewer Services 23 EA $600.00 $13,800.00 39 Manholes -average depth 1 O' 6 EA $2,000.00 $12,000.00 40 Sewer Tie-in at existing 2 EA $400.00 ~800.00 Subtotal $60,890.00 Total Sitework $162,775.00 Total Storm Drainage $32,400.00 Total Water $86,780.00 Total Sanitary Sewer ~60,890 .00 TOT AL CONSTRUCTION I $342,845.oo I Engineering and Surveying @ 6% $20,570.70 Contingency@ 5% $17,142.25 TOTAL I $380,557.951 Page 2 of 2 ~-'1 COLllGl STATION DEVELOPMENT PERMIT PERMIT NO. 100028 DP-STONE FOREST SUBDIVISION PH 3 FOR AREAS OUTSIDE THE SPECIAL FLOOD HAZARD AREA RE: CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: STONE FOREST PHASE 3 DATE OF ISSUE: April 27, 2001 OWNER: JOHNSON INVESTMENTS INC P 0 BOX 800 COLEMAN, TX 76834 TYPE OF DEVELOPMENT: SPECIAL CONDITIONS: SITE ADDRESS: 300 GREENS PRAIRIE RD DRAINAGE BASIN: LICK CREEK VALID FOR 12 MONTHS CONTRACTOR: TEXCON, INC. SINGLE-FAMILY RESIDENTIAL AND INFRASTRUCTURE All construction must be in compliance with the approved construction plans All trees must be barricaded, as shown on plans, prior to any construction. Any trees not barricaded will not count towards landscaping points. Barricades must be l ' per caliper inch of the tree diameter. If it is determined that the presribed erosion control are not effective, it is the responsibility of the Contractor to effectively correct the problem. The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used for temporary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetation be returned to its original condition, placement and state. The Owner and/or Contractor shall be responsible for any damage to adjacent properties, city streets or infrastructure due to heavy machinery and/or equipment as well as erosion, siltation or sedimentation resulting from the permitted work. Any trees required to be protected by ordinance or as part of the landscape plan must be completely fenced before any operations of this permit can begin. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development of an area outside the special flood hazard area. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit 1pplication for the above named project and all of the codes and ordinances of the City of College Station that apply. Date I \Iler/ Agent/Contractor Date • STAFF REVIEW COMMENTS NO. 1 Project: DP-STONE FOREST SUBDIVISION PH 3-DEVELOPMENT PERMIT (1- 100028) ENGINEERING 1. Sheet 4: Please plot the HGL for the 10-yr and 100-yr flows on profile view of storm sewer. Reviewed by: Spencer Thompson Date: April 11, 2001 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans . Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Staff Review Comments Page 1of1 TEX, CON General Contractors Div. of CDS Enterprises, Inc. 1707 Graham Rd. • College Station, TX 77845 • 979-690-7711 • Fax: 979-690-9797 April 19, 2001 Bridgette George Asst. Development Coordinator City of College Station 1101 Texas Avenue South College Station, TX 77842 RE: Stone Forest Subdivision, Phase 3 -College Station, Texas Dear Ms. George: Attached are ten (10) copies of the revised final plat, the Mylar original and five (5) sets of the construction documents marked "Issued for Construction." Also attached are 2 sealed copies of the Design Report for the Proposed Sanitary Sewer Line Improvements and 2 sealed copies of the revised Engineer's Cost Estimate. Quantities for the 6" and 8" sewer pipe (non-structural backfill) were revised to reflect the correction of an error found on Plan Sheet 7. Sewer line S-6 was incorrectly labeled as an 8" line instead of a 6" line. Sheet 7 has also been revised to reflect this correction. If you have any questions or need additional information, please do not hesitate to give me a call at (979) 690-7711. Sincerely Yours, Joe Schultz, P .E. Civil Engineer Attachments ~-v COLLEGE STATION DEVELOPMENT PERMIT PERMIT NO. 100028 DP-STONE FOREST SUBDIVISION PH 3 FOR AREAS OUTSIDE THE SPECIAL FLOOD HAZARD AREA RE: CHAPTER 13 OF THE COLLEGE ST A TION CITY CODE SITE LEGAL DESCRIPTION: STONE FOREST PHASE 3 DATE OF ISSUE: April 3, 2002 OWNER: JOHNSON INVESTMENTS INC P 0 BOX 800 COLEMAN, TX 76834 TYPE OF DEVELOPMENT: SPECIAL CONDITIONS: SITE ADDRESS: 300 GREENS PRAIRIE RD DRAINAGE BASIN: LICK CREEK VALID FOR 6 MONTHS CONTRACTOR: TEXCON, INC. SINGLE-FAMILY RESIDENTIAL AND INFRASTRUCTURE CLEARING AND GRADING All construction must be in compliance with the approved construction plans All trees must be barricaded, as shown on plans, prior to any construction. Any trees not barricaded will not count towards landscaping points. Barricades must be l' per caliper inch of the tree diameter. If it is detemuned that the presribed erosion control are not effective, it is the responsibility of the Contractor to effectively correct the problem. The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used for temporary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetation be returned to its original condition, placement and state. The Owner and/or Contractor shall be responsible for any damage to adjacent properties, city streets or infrastructure due to heavy machinery and/or equipment as well as erosion, siltation or sedimentation resulting from the permitted work. Any trees required to be protected by ordinance or as part of the landscape plan must be completely fenced before any operations of this pernlit can begin. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development of an area outside the special flood hazard area. All development shall be in accordance with the plans and specifications subnlitted to and approved by the City Engineer in the development permit application for the above named project and all of the codes and ordinances of the City of College Station that apply. Date ' Design Report Proposed Sanitary Sewer Line Improvements for Stone Forest Subdivision Phase 3 College Station, Texas April 2001 Prepared By: TEXCON General Contractors 1707 Graham Road College Station, Texas 77845 (979) 690-7711 1.0 INTRODUCTION & DESCRIPTION The purpose of this report is to provide a description of the proposed sanitary sewer to be constructed with the Stone Forest Subdivision, Phase 3, and to provide the criteria used in the design of this sanitary sewer system. The project will include the construction of approximately 1,654 feet of sanitary sewer lin e. The line will tie into the lines constructed during Phase 1 and 2, and service the proposed development of the Phase 3. 2.0 SANITARY SEWER-Design Flow and Pipe Size Calculations The proposed sewer line is to be constructed of 6" and 8" diameter SDR-26, PVC pipe which meets the requirements of ASTM-D3034. The proposed manholes are 4' di ameter manholes, and vary from 8' to 14' in depth, with sewer line slopes ranging from 0.50% to 1.92%. The maximum distance between manholes is less than 500 feet, as required by the Texas Natural Conservation Commission (TNRCC). The minimum allowable slopes for 8" and 6" pipes per TNRCC requirements are 0.33% and 0.50% respectively. All construction shall meet the current City of College Station Standard Specifications for Sanitary Sewer Construction. The sewer line information is summarized in Table 1. 3.0 DETERMINATION OF PEAK FLOW VALVES The peak flows were based on using a daily use of 300 gallons per day for each dwelling unit. The design peak flow is determined by multiplying the average daily flow by 1.5, which results in the adjusted daily flow. This value is then multiplied by 3.0 to determine the peak hourly flow. The velocities for the lines were calculated using Manning's Equation. According to the TNRCC, the minimum velocity for sewer systems flowing full is 2.0 feet per second. As shown in Table 1, the minimum anticipated flow velocities for the proposed sewer lines at 50% full meet this requirement. The flow for 100% full will not be less than the flow for 50% full; therefore, the TNRCC requirement is met. The TNRCC requires that the maximum velocity for sewer systems flow full not exceed 10 feet per second. The values in Table 1 are well below this maximum velocity. TABLE 1 -SEWER LINE FLOW DAT A 0 Manhole No. of Units From Cumulative Average Percent 50% Full z Size Length Slope Peak Flow Cl> Number Dwelling Unit Merging Dwelling Daily Flow Full Flow c :.J From To (in) (ft) (%) Services lines Units (gpm) (cfs) (cfs) (%) (cfs) '? 303 301 6 290.4 0.75 9 -9 1.87 0.0042 0.0188 13.4 0.2430 Cl) O'> rh 304 302 6 289.1 0.50 9 -9 1.87 0.0042 0.0188 14.8 0.1984 0 '7 305 302 6 236.0 1.80 4 -4 0.83 0.0019 0.0084 7.4 0.3764 Cl) 300 Exist devel 6 328.8 1.75 11 -11 2.29 0.0051 0.0230 12.1 0.3711 Te1l'4> Plug 201 6 114.3 1.75 3 ,, -. 14 2.92 0.0065 0.0292 13.5 0.3711 CD rh 201 118 8 199.7 1.50 7 -21 4.37 0.0097 0.0438 11.8 0.7400 118 117 8 96.2 2.00 0 26 (S-7) 47 9.79 0.0218 0.0981 16.3 0.8545 117 105 8 119.0 1.00 3 -50 10.42 0.0232 0.1044 19.9 0.6042 Shaded areas are information that has been previously submitted, and is included for informational purposes only. 302 301 8 323.6 1.92 5 9(5·9),4(5·10) 18 3.75 0.0084 0.0376 10.4 0.8372 301 Exist devel 8 185.5 1.50 2 9(S-8) 29 6.04 0.0135 0.0606 13.3 0.7400 M rh Tellll Plug 113 8 202.1 1.50 2 -31 6.46 0.0144 0.0647 14.2 0.7400 113 112 8 399.6 1.50 5 -36 7.50 0.0167 0.0752 15.3 0.7400 112 103 8 87.3 1.50 2 = 38 7.92 0.0176 0.0793 15.7 0.7400 n =0.013 Refer to construction drawings for manhole locations. 4.0 CONCLUSIONS It is our determination based on the criteria and data developed that the proposed sewer line will provide sufficient capacity for the anticipated wastewater flows generated by this development. 2 __ .... ,,,,, --'\s OF I \\ -:''\ 'r ••••••••••• E:-t ,, ,J' ~ •• •• * ··.:15' •• , * .. •• * '· , *: .. *.., f············· .. ····················'I. l .. A9.~.~I'.tl .. r~ .. ~~.~.Y.~E .... J \1;· .. ~ 65889 0 /41~ •,~··f.91sre.~~··· ~ J ~~~ 4rl~-Ol Velocity (fps) 2.5 2.0 3.8 3.8 3.8 4.2 4.9 3.5 4.8 4.2 4.2 4.2 4.2 I CONSTRUCTION COST ESTIMATE 23-Mar-O 1 STONE FOREST SUBDIVISION COLLEGE STATION, TEXAS PHASE 3 -41 LOTS Item Estimated Unit Estimated No. Description Quantity Price Cost Sitework Mobilization/Layout (entire phase three) LS $5,000.00 $5,000.00 2 Erosion Control/Seeding 1 LS $6,000.00 $6,000.00 3 Site Preparation 2.5 AC $7,000.00 $17,500.00 4 Topsoil Stripping & Replacement 1, 170 CY $4.00 $4,680.00 5 Excavation/Grading 3,510 CY $3.00 $10,530.00 6 Lime Stabilized Subgrade 6,800 SY $3.00 $20,400.00 7 Concrete Laydown Curb 3,590 LF $7.00 $25,130.00 8 Base Material -6" depth 5,400 SY $6.00 $32,400.00 9 Asphalt Paving -1 1 /2" depth 5,400 SY $4.75 $25,650.00 10 Concrete Aprons 550 SF $5.00 $2,750.00 11 Sidewalks 4,340 SF $2.75 $11 ,935.00 12 ADA Ramps 2 EA $400.00 ~800.00 Subtotal $162,775.00 Storm Drainage 13 Drainage Pipe -18" RCP -structural 0 LF $36.00 $0.00 14 Drainage Pipe -18" RCP -non-structural 290 LF $26.00 $7,540.00 15 Drainage Pipe -24" RCP -structural 165 LF $42.00 $6,930.00 16 Drainage Pipe -24" RCP -non-structural 315 LF $32.00 $10,080.00 17 Inlets 5' wide/junction boxes EA $2,250.00 $2,250.00 18 Inlets 10' wide 2 EA $2,800.00 ~5,600.00 Subtotal $32,400.00 Water lines 19 6" Water PVC CL200 (C900) structural 125 LF $24.00 $3,000.00 20 6" Water PVC CL200 (C900) non-structural 215 LF $18.00 $3,870.00 21 8" Water PVC CL200 (C900) structural 1,220 LF $28.00 $34, 160.00 22 8" Water PVC CL200 (C900) non-structural 370 LF $20.00 $7,400.00 23 Gate Valves -6" 1 EA $550.00 $550.00 24 Gate Valves -8" 3 EA $600.00 $1 ,800.00 25 M.J. Bends/Reducers -8" 8 EA $300.00 $2,400.00 26 M.J. Tees -8" 4 EA $300.00 $1,200.00 27 Tapping Sleeve & Valve 18" x 8" 1 EA $12,000.00 $12,000.00 28 Water Services 20 EA $700.00 $14,000.00 29 Water Tie-in at existing stub out 4 EA $500.00 $2,000.00 30 2" Blow off Assembly EA $400.00 $400.00 31 Fire Hydrant Assembly 2 EA $2,000.00 ~4,000.00 Subtotal $86,780.00 Sanitary Sewer Lines 32 8" SOR 26 Pipe -structural 65 LF $28.00 $1,820.00 33 8" SOR 26 Pipe -non-structural 750 LF $22.00 $16,500.00 34 8" ASTM 2261 pressure pipe -structural 40 LF $32.00 $1 ,280.00 35 8" ASTM 2261 pressure pipe -non -struct. 0 LF $24.00 $0.00 36 6" SOR 26 Pipe -structural 160 LF $24.00 $3,840.00 37 6" SOR 26 Pipe -non-structural 670 LF $18.00 $12,060.00 38 Sewer Services 23 EA $600.00 $13,800.00 39 Manholes -average depth 1 O' 6 EA $2,000.00 $12,000.00 40 Sewer Tie-in at existing 2 EA $400.00 ~800.00 Subtotal $62,100.00 Total Sitework $162,775.00 Total Storm Drainage $32,400.00 Total Water $86,780.00 Total Sanitary Sewer 62 100.00 TOT AL CONSTRUCTION $344,055.00 Engineering and Surveying @ 6% $20,643.30 Contingency@ 5% $17,202.75 TOTALj $381,901.051 Drainage Report for R~VIEWeb FOR l co~_APf. f A~ APR 11 200 COLLEGE STATIO ENGINEERING FILE Stone Forest Subdivision, Phase 3 College Station, Texas April 2001 D eveloper: Johnson Investments, Inc. 1400 Commercial A venue Coleman, Texas 76834 (915) 625-2124 Prepared By: TEXCON General Contractors 1707 Graham Road College Station, Texas 77845 (979) 690-7711 CERTIFICATION I, Joseph P. Schultz, Licensed Professional Engineer No. 65889, State of Texas, certify that this report for the drainage design for the Stone Forest Subdivision, Phase 3, was prepared by me in accordance with the provisions of the City of College Station Drainage Policy and Design Standards for the owners hereof. ~''''''' --~~OF /~ \\ ... -<._i>-•••••••••• ..+--<? '• Fe.; .. ··· * ·· ... IS' •, "* .. ·. * , "*: ·•l ~·································· ~ 1 .. A9.~.~r.tl .. ~~ .. ~~~.~.~E .... J '~~-·~ 65889 Q /! J 1fa'<'-"0·f.G1srE.~~··0· Y ''''&,s ......... ~ ., \~: .. ,,~~~~t--r ... :: .. TABLE OF CONTENTS DRAINAGE REPORT STONE FOREST SUBDIVISION, PHASE 3 CERTIFICATION ......................................................................................................................................................... 1 TABLE OF CONTENTS ............................................................................................................................................... 2 LIST OF TABLES ......................................................................................................................................................... 3 INTRODUCTION .......................................................................................................................................................... 4 GENERAL LOCATION AND DESCRIPTION ......................................................................................................... 4 FLOOD HAZARD INFORMATION ........................................................................................................................... 4 DEVELOPMENT DRAINAGE PATTERNS .............................................................................................................. 4 DRAINAGE DESIGN CRITERIA ............................................................................................................................... 5 STORM WATER RUNOFF DETERMINATION ...................................................................................................... 5 DETENTION FACILITY DESIGN ............................................................................................................................. 6 STORM SEWER DESIGN ........................................................................................................................................... 6 CONCLUSIONS ............................................................................................................................................................ 7 APPENDIX A ................................................................................................................................................................. 8 Storm Sewer Inlet Design Calculations APPENDIX B ............................................................................................................................................................... 10 Storm Sewer Pipe Design Calculations EXHIBIT B ................................................................................................................................................................... 20 Post-Development Drainage Areas -Storm Sewer Design 2 LIST OF TABLES TABLE 1 -Rainfall Intensity & Time of Concentration Calculations .................................................... 5 TABLE 2 -Post-Development Runoff Information -Storm Sewer System ............................................ 6 3 DRAINAGE REPORT STONE FOREST SUBDIVISION, PHASE 3 INTRODUCTION The purpose of this report is to provide the hydrological effects of the construction of the Stone Forest Subdivision, Phase 3, and to show that the proposed storm drainage system meets the requirements set forth by the City of College Station to control storm water runoff in such a manner so as to have no offsite or downstream impact. GENERAL LOCATION AND DESCRIPTION The project is located on a 4 7.42 acre tract located east of State Highway 6 along the south side of Greens Prairie Road in College Station, Texas. Phase 3 is made up of 12.28 acres. This report primarily addresses the storm sewer drainage for Phase 3; however, information concerning Phases 1 & 2 has been included for clarification. For information regarding the pre-development conditions and the detention facility for this subdivision, refer to the Drainage Report for Phase 1, dated October 2000. For information regarding Phase 2, refer to the Drainage Report for Phase 2, dated February 2001. The site is wooded with the vegetation primarily consisting of oak trees and yaupons. The existing ground elevations range from elevation 260 to elevation 310. The general location of the project site is shown on the vicinity map in Exhibit B. FLOOD HAZARD INFORMATION The project site is located in the Spring Creek branch of the Lick Creek Drainage Basin. The site is located in a Zone X Area according to the Flood Insurance Rate Map prepared by the Federal Emergency Management Agency (FEMA) for Brazos County, Texas and incorporated areas dated July 2, 1992, panel number 48041C0205-C. Zone X Areas are determined to be outside of the 500-year floodplain. DEVELOPMENT DRAINAGE PATTERNS The storm water runoff from the site prior to development flows in two general directions. The majority of the project site flows toward the north and northeast into the drainage ditch in the Greens Prairie Road right-of-way. The southern comer of the acreage flows to the south onto the adjacent property. Refer to the Drainage Report for Phase 1, Exhibit A for the pre-development drainage areas. After development, a majority of the storm water runoff from the site will be captured by the proposed detention pond at the north end of the acreage. Information pertaining to this detention pond is summarized in the Drainage Report for Phase 1. The post-development drainage area boundaries used for the storm sewer design are shown in Exhibit B. The post-development runoff will be controlled and released at or below the pre-development peak runoff rates for the design storm event by detaining the runoff in the detention pond. The design criteria and results of the detention pond design are included in the Drainage Report for Phase 1. 4 DRAINAGE DESIGN CRITERIA The des ign parameters for the storm sewer are as follows: • The Rational Method is utilized to determine peak storm water runoff rates for the storm sewer design. • Design Storm Frequency Storm Sewer system 10 and 100-year storm events • Runoff Coefficients -Rational Equation Post-development (single family residential) c = 0.55 • Rainfall Intensity values for Brazos County for a minimum time of concentration of 10 minutes can be found in Table 1. Where a longer time of concentration was necessary, it is noted in the respective table, and the intensities are calculated with the higher values where required STORM WATER RUNOFF DETERMINATION The peak runoff values were determined in accordance with the criteria presented in the previous section for the 5, 10, 25 , 50, and 100-year storm events. The runoff coefficients are based on the future development of this tract. The drainage areas for post-development are shown in Exhibit B. Post-development runoff conditions are summarized in Table 2. TABLE 1 -Rainfall Intensity & Time of Concentration Calculations The Rational Method: Q=CIA Q = Flow (cfs) A = Area (acres) C = Runoff Coeff. I = Rainfall Intensity (in/hr) Rainfall Intensity Values (in/hr) Storm t.:= Event 10min Is 7.693 110 8.635 125 9.861 lso 11.148 1100 11 .639 Brazos County: 5 y_ear storm 10 y_ear storm b = 76 b = 80 d = 8.5 d = 8.5 e = 0.785 e = 0.763 I= b I (t.:+d)e I = Rainfall Intensity (in/hr) t.: = U(V*60) tc; =Time of concentration (min) L = Length (ft) V =Velocity (ft/sec) 25 y_ear storm 50 y_ear storm b = 89 b = 98 d = 8.5 d = 8.5 e = 0.754 e = 0.745 (Data taken from State Department of Hiqhway_s and Public Transportation Hy_draulic Manual , page 2-16) s 100 y_ear storm b = 96 d = 8.0 e = 0.730 TABLE 2 -Post-Development Runoff Information -Storm Sewer System Area c Os 010 025 Oso Area# (acres) tc A1 Ai C1 C2 Crotal Total (min) (cfs) (cfs) (cfs) (cfs) 201 4.22 0 4 .22 0.55 0 0.55 10 17.86 20.04 22.89 25.87 202 0.32 0 0.32 0.55 0 0.55 10 1.35 1.52 1.74 1.96 203 1.45 0 1.45 0.55 0 0.55 10 6.14 6.89 7.86 8.89 204 0.37 0 0.37 0.55 0 0.55 10 1.57 1.76 2.01 2.27 205 2.10 0 2.10 0.55 0 0.55 10 8.89 9.97 11 .39 12.88 206 1.77 0 1.77 0.55 0 0.55 10 7.49 8.41 9.60 10.85 207 1.27 0 1.27 0.55 0 0.55 10 5.37 6.03 6.89 7.79 207A 0.86 0 0.86 0.55 0 0.55 10 3.64 4.08 4.66 5.27 208 0.55 0 0.55 0.55 0 0.55 10 2.33 2.61 2.98 3.37 209 0.93 0 0.93 0.55 0 0.55 10 3.93 4.42 5.04 5.70 210 0.72 0 0.72 0.55 0 0.55 10 3.05 3.42 3.90 4.41 211 1.00 0 1.00 0.55 0 0.55 10 4.23 4.75 5.42 6.13 212 0.59 0 0.59 0.55 0 0.55 10 2.50 2.80 3.20 3.62 213 1.96 0 1.96 0.55 0 0.55 10 8.29 9.31 10.63 12.02 214 1.12 0 1.12 0.55 0 0.55 10 4.74 5.32 6.07 6.87 215 2.12 0 2.12 0.55 0 0.55 10 8.97 10.07 11 .50 13.00 216 0.50 0 0.50 0.55 0 0.55 10 2.12 2.37 2.71 3.07 217 1.50 0 1.50 0.55 0 0.55 10 6.35 7.12 8.14 9.20 218 2.25 0 2.25 0.55 0 0.55 10 9.52 10.69 12.20 13.80 219 1.26 0 1.26 0.55 0 0.55 10 5.33 5.98 6.83 7.73 220 2.35 0 2.35 0.55 0 0.55 10 9.94 11 .16 12.75 14.41 221 0.95 0 0.95 0.55 0 0.55 10 4.02 4.51 5.15 5.82 222 1.25 0 1.25 0.55 0 0.55 10 5.29 5.94 6.78 7.66 223 0.28 0 0.28 0.55 0 0.55 10 1.18 1.33 1.52 1.72 224 0.22 0 0.22 0.55 0 0.55 10 0.93 1.04 1.19 1.35 225 0.56 0 0.56 0.55 0 0.55 10 2.37 2.66 3.04 3.43 226 0.73 0 0.73 0.55 0 0.55 10 3.09 3.47 3.96 4.48 227 2.22 0 2.22 0.55 0 0 .55 10 9.39 10.54 12.04 13.61 228 1.27 0 1.27 0.55 0 0.55 10 5.37 6.03 6.89 7.79 229 1.39 0 1.39 0.55 0 0.55 10 5.88 6.60 7.54 8.52 230 0.23 0 0.23 0.55 0 0 .55 10 0.97 1.09 1.25 1 .41 231 0.99 0 0.99 0.55 0 0.55 10 4.19 4.70 5.37 6.07 232 0.84 0 0.84 0.55 0 0.55 10 3.55 3.99 4.56 5.15 233 2.49 0 2.49 0.55 0 0.55 10 10.54 11.83 13.50 15.27 234 1.78 0 1.78 0.55 0 0.55 10 7.53 8.45 9.65 10.91 235 1.70 0 1.70 0.55 0 0.55 10 7.19 8.07 9.22 10.42 236 5.56 0 5.56 0.55 0 0.55 10 23.53 26.41 30.15 34.09 DETENTION FACILITY DESIGN Information regarding the detention facility design can be found in the Drainage Report for Phase 1, dated October 2000. STORM SEWER DESIGN The storm sewer piping for this project has been selected to be Reinforced Concrete Pipe (RCP) meeting the requirements of ASTM C-76, Class III pipe. The curb inlets and junction boxes will be cast-in-place concrete. 6 0100 (cfs) 27.01 2.05 9.28 2.37 13.44 11 .33 8.13 5.51 3.52 5.95 4.61 6.40 3.78 12.55 7.17 13.57 3.20 9.60 14.40 8.07 15.04 6.08 8.00 1.79 1.41 3.58 4.67 14.21 8.13 8.90 1.47 6.34 5.38 15.94 11 .39 10.88 35.59 Appendix A presents a summary of the storm sewer inlet design parameters and calculations. The inlets were designed based on a 10-year design storm. As per College Station guidelines, the capacities of inlets in sump were reduced by 10% to allow for clogging. Inlets were located to maintain a gutter flow depth of 5" or less, which will prevent the spread of water from reaching the crown of the road for the 10-year storm event. The runoff intercepted by the proposed storm sewer inlets was calculated using the following equations. The depth of flow in the gutter was determined by using the Straight Crown Flow equation. The flows intercepted by Inlets 8, 9, 10, 14, 15, 17, 18 & 21 were calculated by using the Capacity of Inlets On Grade equation. The capacities for the inlets in sumps (Inlets 1-7, 11-13, 16, 19, 20 & 22) were calculated using the Inlets in Sumps, Weir Flow equation with a maximum allowable depth of 7" (5" gutter flow plus 2" gutter depression). These equations and the resulting data are summarized in Appendix A. Inlets 1-7, 14-19, & 21 were constructed during Phase 1 of this subdivision. Inlets 8, 9, 11 , 12 & 13 were constructed during Phase 2 of this subdivision. Inlets 10, 20 & 22 will be constructed during Phase 3 of this subdivision. The area between the right-of-way and the curb line of the streets will be filled as necessary to provide a minimum of 6" of freeboard above the curb line. This will ensure that the runoff from the 100-year storm event will remain within the street right-of-way. Appendix B presents a summary of the storm sewer pipe design parameters and calculations. All pipes are 18" in diameter or larger. For pipes with 18" and 24" diameters, the cross-sectional area is reduced by 25%, as per College Station requirements. A summary of how this was achieved is shown in Appendix Bas well. The pipes for the storm sewer system were designed based on the 10-year storm event; however, all will also pass the 100-year storm event without any headwater. As required by College Station, the velocity of flow in the storm sewer pipe system is not lower than 2.5 feet per second, and it does not exceed 15 feet per second. As the data shows, even during low flow conditions, the velocity in the pipes will exceed 2.5 feet per second and prevent sediment build-up in the pipes. The maximum flow in the storm sewer pipe system will occur in Pipe 9. Appendix B contains a summary of the Manning pipe calculations as well as flow diagrams mapping the flows through the storm sewer system for the 10 and 100-year events. The maximum velocity for the pipe system will be 14.83 feet per second and will occur in Pipes 21 & 22. The maximum velocity for Phase 3 is 14.1 feet per second in Pipe 5. The pipes in Phase 3 include Pipes 5, 6 & 25. Pipes 5 and 25 will be tied into existing pipes placed during construction for Phases 1 & 2. The hydraulic grade lines (HGL) for the 10-and 100-year storm events have been shown on the plan/profile sheets of the construction documents. CONCLUSIONS The construction of this project will significantly increase the storm water runoff from this site. However, the detention pond (constructed during Phase 1) will adequately reduce the peak post-development runoff to less than the pre-development runoff for the design storm event. No flood damage to downstream landowners is expected as a result of this development. 7 APPENDIX A Storm Sewer Inlet Design Calculations 8 Stone Forest Subdivision Inlet Length Calculations Inlets In Sump Inlet# Length & Type Flow from Area# '1 10' Standard 202 203 '2 5' Standard 209 '3 10· Standard 208 213 '4 10' Standard 204 205 '5 1 o· Standard 206 '6 5' Standard 214 '7 15' Standard 207A ·11 10' Standard 221 ~ '12 5' Standard 223 226 '13 5' Standard 224 225 '16 1 O' Standard 210 211 '19 10' Standard 216 217 20 5' Standard 230 231 22 10' Standard 228 232 A c Q,, Q. • .,,_w (acres) (els) (els) from Inlet# 0.32 0.55 1.52 1.45 0.55 6.89 0.93 0.55 ~ 0.55 0.55 2.61 1.96 0.55 9.31 0.37 0.55 1.76 2.10 0.55 9.97 1.77 0.55 8.41 1.12 0.55 5.32 0.00 8 0.86 0.55 4.08 5.93 21 0.95 0.55 4.51 1.25 0.55 5.94 0.28 0.55 1.33 0.73 0.55 3.47 0.22 0.55 1.04 0.56 0.55 2.66 0.72 0.55 3.42 1.00 0.55 4.75 0.50 0.55 2.37 1.50 0.55 7.12 0.23 0.55 1.09 0.99 0.55 4.70 1.27 0.55 6.03 0.84 0.55 3.99 1 O year storm Orot.1 Orot.1•10".llo Y10-.i L1D.fl9q'cf L10-.ct...i o, .. (els) (els) (fl) (In) (fl) (fl) (els) 1.52 1.67 0.176 2.11 6.92 10 2.05 6.89 7.58 0.311 3.73 9.28 4.42 4.86 0.263 3.15 5.95 -3.64 5 2.61 2.87 0.216 2.59 3.52 -9.82 10 9.31 10.24 0.348 4.17 12.55 1.76 1.93 0.186 2.23 9.66 10 2.37 9.97 10.97 0.357 4.28 13.44 8.41 9.25 0.335 4.02 6.92 10 11.33 5.32 5.85 0.282 3.38 4.38 5 7.17 10.01 11.01 0.357 4.29 8.25 15 5.51 4.51 4.96 0.265 3.18 8.61 10 6.08 5.94 6.53 0.294 3.52 8.00 1.33 1.46 0.168 2.01 3.95 5 ~ 3.47 3.81 0.240 2.88 4.67 1.04 1.15 0.153 1.84 3.05 5 1.41 I---2.66 2.93 0.217 2.61 3.58 3.42 3.76 0.239 2.87 6.73 10 4.61 4.75 5.22 0.270 3.24 6.40 2.37 2.61 0.208 2.50 7.82 10 3.20 7.12 7.84 0.315 3.77 9.60 1.09 1.20 0.156 1.87 1.47 4.77 5 I---4.70 5.17 0.269 3.23 6.34 6.03 6.63 0.296 3.55 8.25 10 8.13 ~ 3.99 4.39 0.253 3.04 5.38 'These inlets have been constructed dunng Phase 1 & 2, and are 1nduded for mformatt0nal purposes only. *u#'fly-•7"•0.583' Inlets On Grade 10 year storm Inlet# Length & Type Flow from y,. Q,_,_ Ocap1ur.d Q,,,pou Q.•"Y••w Qbyp--total <leap.cot al 0 10-Total Area# (ft) (in) (ft) (els) (els) (els) fromlnllll# (els) (els) (els) '8 10' Recessed 219 0.314 3.77 0.61 6.06 -0.08 0.00 6.08 6.06 '9 1 O' Recessed 220 0.420 5.04 0.69 6.87 4.29 2.03 10 6.32 6.87 13.19 10 1 O' Recessed 227 0.386 4.63 0.68 6.78 2.03 2.03 6.78 8.82 '14 1 o· Recessed 218 0.388 4.66 0.68 6.81 3.88 3.88 6.81 10.69 '15 10· Recessed 229 0.324 3.89 0.62 6.18 0.43 0.43 6.18 6.60 '17 5'Recessed 212 0.242 2.91 0.54 2.70 0.10 0.10 2.70 2.80 '18 15' Recessed 215 0.449 5.39 0.68 10.26 -5.57 4.30 14, 15 0.00 14.56 14.56 ·21 10· Recessed 207 0.462 5.55 0.64 6.42 -0.39 6.32 9 5.93 6.81 12.74 'These inlets have been constructed dunng Phase 1 & 2, and are included for 1nformat1onal purposes only. Transverse (Crown) slope (fVft) = 0.033 Straight Crown Flow (Solved to find actual depth of flow. y): o = o.56 • (zln) • s112 • y"' Q y = {Q / [0.56 • (zln) • s'"n"' n = Roughness Coefficient = z = Reciprocal of crown slope= S = StreeVGutter Slope (fVft) y = Depth of flow at inlet (ft) Capacity of Inlets on grade: Oe = 0.7 • [11(H1-H2)] • [H,'12-H2 512] Oe =Flow capacity of inlet (els) H, =a+ y O.Q18 30 H2 =a= gutter depression (2" Standard; 4" Recessed) y = Depth of flow in approach gutter (fl) Inlets In sumps, Weir Flow: L=Q /(3'y312) Q y=(Q /3L)213 L = Length of inlet opening (ft) Q = Flow at inlet (cfs) y = total depth of flow on inlet (ft) max y for inlet in sump= 7" = 0.583' Y100 (ft) (in) 0.349 4.19 0.488 5.86 0.431 5.18 0.434 5.21 0.362 4.35 0.271 3.25 0.531 6.37 0.552 6.62 100 year storm <l,;.")'0¥ .. o, .... Orotal+tn Y100 (els) from Inlet ti (els) (els) (fl) (In) 2.05 ~ 0.557 6.68 9.28 10.21 5.95 6.55 ----0.575 6.91 3.52 3.87 0.703 8.43 12.55 13.80 2.37 2.61 0.695 8.34 13.44 14.79 11.33 12.46 0.557 6.68 1.64 8 8.81 9.69 0.747 8.97 13.62 21 19.13 21.04 0.602 7.23 - 6.08 6.69 0.644 7.72 ----8.00 8.80 1.79 1.97 0.608 7.30 ----4.67 5.14 1.41 1.55 0.512 6.14 --------3.58 3.94 4.61 5.07 0.546 6.55 6.40 7.04 3.20 3.52 0.604 7.25 ----9.60 10.56 1.47 1.62 0.690 8.28 --------6.34 6.97 8.13 8.94 0.626 7.51 --------5.38 5.91 100 year storm Q,_,_ Ocaptur.cf a bypton Q. • .,,_w Cbyp-toca1 °"•p-total 0 100-Total s l~ual (fl) (els) (els) (els) from Inlet# (els) (els) (els) (ft/ft) (fl) 0.64 6.42 1.64 1.64 6.42 8.07 0.0200 10 -----rn-,_ ------0.74 7.69 4.64 10 12.33 7.35 19.68 0.0200 10 0.72 7.25 4.64 4.64 7.25 '----:;1.89 0.0141 10 0.73 7.28 7.12 7.12 7.28 14.40 0.0200 10 0.66 6.55 2.35 2.35 6.55 ~ 0.0200 10 0.57 2.83 0.94 0.94 2.83 3]8 0.0170 5 0.73 10.97 -10.54 11.76 ~ 1.22 21.51 22.73 0.0170 15 0.68 6.83 1.30 12.33 9 13.62 6.83 2D.46 0.0112 10 APPENDIXB Storm Sewer Pipe Design Calculations 10 Stone Forest Subdivision Pipe Calculations Slope Upstream Pipe# Size Length Elev (in) (ft) (%) (ft) 5 24 100.6 3.50 290.45 6 24 370.5 2.00 298.31 ---25 18 287.0 1.75 302.24 Downstrearr Elev *Actual Flow (ft) (cfs) 286.93 15.81 290.90 10.02 297.22 6.78 1 O year storm 100 year storm *Actual Flow V100 Design Flow V10 Travel Time, tT1o Design Flow %Full %Full (cfs) (fps) (sec) (min) (cfs) (cfs) (fps) 25.53 13.3 58.7 8 0.13 21 .3 34.43 14.1 72.5 16.18 9.7 52.6 38 0.64 13.5 21.82 10.3 63.7 10.95 8.2 70.7 35 0.58 7.25 11.71 8.3 74.7 *These values reflect the actual fl ow for the 18" & 24" pipes. The design flow for these pipe sizes reflects a 25% reducti on in pipe area. (Refer to attached calculation for specific information.) Refer to the Drainage Report for Phase 1 or Phase 2 for information on other pipes in this storm sewer system. Travel Time, tT1oo (sec) (min) 7 0.12 36 0.60 35 0.58 City of College Station requirement to Reduce Cross-Sectional Area of 18" & 24" Pipes by 25% Using Mannings Equation from page 48 of the College Station Drainage Policy & Design Standards Manual: Q = 1.49/n *A* R213 * S112 Q =Flow Capacity (cfs) 18" Pipe: Pipe size (inches) = 18 Wetted Perimeter WP, (ft)= 4.71 Cross-Sectional Area A, (tt2) = 1.766 Reduced Area AR, (ft2) = 1.325 Hydraulic Radius R =A/WP, (ft)= 0.375 Reduced Hydr Radius RR= AR/Wp, (ft)= 0.281 Roughness Coefficient n = 0.014 Friction Slope of Conduit St. (ft/ft) = 0.01 Example Calculation: Slope Flow Capacity Reduced Flow Capacity % Difference s Q Oreduced Oreduced/Q 0.005 6.91 4.28 0.619 0.006 7.57 4.69 0.619 0.007 8.18 5.06 0.619 24" Pipe: Pipe size (inches) = 24 Wetted Perimeter WP, (ft)= 6.28 Cross-Sectional Area A, (tt2) = 3.14 Reduced Area AR, (tt2) = 2.355 Hydraulic Radius R =A/WP, (ft)= 0.5 Reduced Hydr Radius RR= AR/Wp, (ft)= 0.375 Roughness Coefficient n = 0.014 Friction Slope of Conduit S1, (ft/ft) = 0.01 Example Calculation: Slope Flow Capacity Reduced Flow Capacity % Difference s Q Oreduced Oreduced/Q 0.005 14.89 9.22 0.619 0.006 16.31 10.1 0.619 0.007 17.61 10.9 0.619 Conclusion: Multiply actual Q in 18" & 24" pipes by 1.615 to reflect a 25% reduction in the cross-sectional area called for on page 47, paragraph 5 of the College Station Drainage Policy & Design Standards manual. 12- Stone Forest Subdivision Pipe Flow Diagram 010 {cfs) Shaded areas were constructed during Phase 1 & 2 development. Inlet 22 I 10.02 J, Pipe 6 I 10.02 J, Inlet 20 I 5.79 J, I Inlet 1 I 8.41 I l Pipe 5 I 15.81 J, II Pipe 8 I 8.41 II Inlet 19 I 9.49 J, Pipe 4 I 25.30 J, Inlet 18 I 14.56 J, Pipe 3 I 39.86 J, Inlet 17 I 2.70 J, Pipe 2 I 42.56 J, Inlet 16 I 8.17 J, II Pipe 1 I 50.73 II Inlet 8 I 6.06 J, Pipe 24 I 6.06 Inlet 10 I 6.78 J, Pipe 25 I 6.78 Inlet 15 I 6.18 J, Pipe 14 I 6.18 _J, Inlet 14 I 6.81 J, Pipe 13 I 12.99 J, June Box 1 J, Pipe 12 I 12.99 J, June Box 2 J, Pipe 11 I 12.99 Stone Forest Subdivision Pipe Flow Diagram 010 (cfs) Shaded areas were constructed during Phase 1 & 2 development. -7 Inlet 21 I 6.81 -7 -7 1' _J, 1' J, Pipe 22 I 45.47 1' J, 1' J, June Box 5 -7 1' _J, 1' J, J, Pipe 21 I 45.47 Inlet 9 I 6.87 1' J, 1' J, Inlet 7 I 10.01 Pipe 23 I 19.71 -7 1' _J, 1' Pipe 20 I 55.48 _J, 1' Inlet 6 I 5.32 J, 1' Pipe 19 I 60.80 _J, 1' Inlet 4 I 11. 73 June Box 4 J, J, 1' Pipe 17 I 11 . 73 Pipe 18 I 60.80 J, Inlet 5 I 8.41 J, Pipe 16 I 80.94 J, June Box 3 J, Pipe 15 I 80.94 Inlet 3 I 11 .92 J, Pipe 1 O I 105.85 J, Inlet 2 I 4.42 -lt II Pipe 9 I 110.21 Ii Inlet 13 I 3.70 _J, Pipe 30 I 3.70 J, Inlet 12 I 4.80 _J, Pipe 29 I 8.50 J, June Box 7 _J, Pipe 28 I 8.50 _J, Inlet 11 I 10.45 J, Pipe 27 I 18.95 _J, June Box 6 J, Pipe 26 I 18.95 Stone Forest Subdivision Pipe Flow Diagram Q100 (cfs) Shaded areas were constructed during Phase 1 & 2 development. ~-------' Inlet 22 I 13.51 J, Pipe 6 I 13.51 J, Inlet 20 I 7.81 J, Pipe 5 I 21.32 J, Inlet 19 I 12.80 J, Pipe 4 I 34 .12 J, lnlet18 I 21.51 J, Pipe 3 I 55.63 J, Inlet 17 I 2.83 J, Pipe 2 I 58.46 J, Inlet 16 I 11.01 J, II Pipe 1 I 69.47 II I Inlet 1 111.33 I II Pipe 8 I 11 .33 II Inlet 8 I 6.42 J, Pipe 24 I 6.42 Inlet 10 I 7.25 J, Pipe 25 I 7.25 Inlet 15 I 6.55 J, Pipe 14 I 6.55 J, Inlet 14 I 7.28 J, Pipe 13 I 13.83 J, June Box 1 J, Pipe 12 I 13.83 J, June Box 2 J, Pipe 11 I 13.83 Stone Forest Subdivision Pipe Flow Diagram 0 100 (cfs) Shaded areas were constructed during Phase 1 & 2 development. -? Inlet 21 I 6.83 -? -? 1' J, 1' J, Pipe 22 I 53.38 1' J, 1' J, June Box 5 -? 1' J, 1' J, J, Pipe 21 I 53.38 Inlet 9 I 7 .35 1' J, 1' J, Inlet? I 19.13 Pipe 23 I 21.02 -? 1' J, 1' Pipe 20 I 72.51 J, 1' Inlet 6 I 8.81 J, 1' Pipe 19 I 81 .32 J, 1' Inlet 4 I 15.81 June Box 4 J, J, 1' Pipe 17 I 15.81 Pipe18 I 81 .32 J, Inlet 5 I 11 .33 J, Pipe 16 j 108.46 J, June Box 3 J, Pipe 15 I 108.46 Inlet 3 I 16.07 J, Pipe 10 I 138.36 J, Inlet 2 I 5.95 J, II Pipe 9 I 144.31 II t(p Inlet 13 I 4.99 J, Pipe 30 I 4.99 J, Inlet 12 I 6.46 J, Pipe 29 I 11 .45 J, June Box 7 J, Pipe 28 I 11 .45 J, Inlet 11 I 14.08 J, Pipe 27 I 25.53 J, June Box 6 J, Pipe 26 I 25.53 Pipe 5 -10 Year Storm Manning Pipe Calculator Given Input Data : Shape .......................... . Solv ing for .................... . Diameter ....................... . Flowrate ....................... . Slope .......................... . Manning's n .................... . Computed Results: Depth .......................... . Area ........................... . Wetted Area .................... . Wetted Perimeter ............... . Perimeter ...................... . Velocity ....................... . Hy draulic Radiu s ............... . Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Circular Depth of Flow 24.0000 in 25.5300 cfs 0 .0350 ft/ft 0. 0140 14.0896 in 452 .3893 in2 276.0894 in2 41.8996 in 75.3982 in 13.3157 fps 6.5893 in 58.7065 % 39.2996 cfs 12.5094 fps Pipe 5 -100 Year Storm Manning Pipe Calcu lator Given Input Data : Shape .......................... . Solving for .................... . Diamet er ....................... . Flowrate ....................... . Slope .......................... . Manning' s n .................... . Computed Results : Depth .......................... . Area ........................... . Wetted Area .................... . Wetted Perimeter ............... . Perimeter ...................... . Velocity ....................... . Hydraulic Radius ............... . Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Stone Forest Subdivision, Phase 3 College Station, Texas 11 Circular Depth of Flow 24.0000 in 34.4300 cfs 0.0350 ft/ft 0. 0140 17.4095 in 452.3893 in2 351.4810 in2 48.9228 in 75.3982 in 14.1058 fps 7.1844 in 72.5396 % 39.2996 cfs 12.5094 fps Pipe 6 -10 Year Storm Manning Pipe Calculator Given Input Data: Shape .......................... . Solving for .................... . Diameter ....................... . Flowrate ....................... . Slope .......................... . Manning's n .................... . Computed Results: Depth .......................... . Area ........................... . Wetted Area .................... . Wetted Perimeter ............... . Perimeter ...................... . Velocity ....................... . Hy draulic Radius ............... . Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Circular Depth of Flow 24.0000 in 16.1800 cfs 0.0200 ft/ft 0 . 0140 12.6273 in 452.3893 in2 241.2437 in2 38 .9543 in 75.3982 in 9.6580 fps 6 .1930 in 52.6139 % 29.7077 cfs 9.4563 fps Pipe 6 -100 Year Storm Manning Pipe Calculator Given Input Data: Shape .......................... . Solving for .................... . Diameter ....................... . Flowrate ....................... . Slope .......................... . Manning ' s n .................... . Computed Results: Depth .......................... . Area ........................... . Wetted Area .................... . Wetted Perimeter ............... . Perimeter ...................... . Velocity ....................... . Hydraulic Radius ............... . Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Stone Forest Subdivision, Phase 3 College Station, Texas ,, Circular Depth of Flow 24.0000 in 21.8200 cfs 0.0200 ft/ft 0. 0140 15.2852 in 452.3893 in2 304.0424 in2 44.3544 in 75.3982 in 10.3343 fps 6.8548 in 63.6882 % 29 .7077 cfs 9.4563 fps Pipe 25 -10 Year Storm Manning Pipe Calculator Given Input Data: Shape .......................... . Solving for .................... . Diameter ....................... . Flowrate ....................... . Slope .......................... . Manning ' s n .................... . Computed Results: Depth .......................... . Area ........................... . Wetted Area .................... . Wetted Perimeter ............... . Perimeter ...................... . Velocity ....................... . Hydraulic Rad ius ............... . Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Circular Depth of Flow 18.0000 in 10.9500 cfs 0.0175 ft/ft 0. 0140 12.7318 in 254.4690 in2 192.4287 in2 35.9702 in 56.5487 in 8.1942 fps 5.3497 in 70.7321 % 12.9034 cfs 7.3018 fps Pipe 25 -100 Year St orm Manning Pipe Calculator Given Input Data: Shape .......................... . Solving for .................... . Diameter ....................... . Flowrate ....................... . Slope .......................... . Manning ' s n .................... . Computed Results: Depth .......................... . Area ........................... . Wetted Area .................... . Wetted Perimet er ............... . Perimeter ...................... . Velocity ....................... . Hydraulic Radius ............... . Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Stone Forest Subdivision, Phase 3 College Station, Texas \~ Circular Depth of Flow 18.0000 in 11.7100 cfs 0.0175 ft/ft 0 . 0140 13. 4446 in 254.4690 in2 203.8551 in2 37.5715 in 56.5487 in 8.2718 fps 5.4258 in 74.6924 % 12.9034 cfs 7.3018 fps EXHIBITB Post-Development Drainage Areas -Storm Sewer Design 20