HomeMy WebLinkAboutStaff Comments( /" CITY OF COTI J1 GL STATION Hone ofTexas AcW University" September 27, 2012 Planning & Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM TO: Rabon Metcalf, RME Consulting Engineers; via email: rabon@rmengineer.com FROM: Morgan Hester, Staff Planner SUBJECT: CREEK MEADOWS SEC 4 PH 3A & 4 (FP) - Final Plat Staff reviewed the above -mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted, your project will be placed on the next available Planning and Zoning Commission meeting held in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24"x36" copy of the revised final plat; Thirteen (13) 11'k17" copies of the revised final plat; One (1) Mylar original of the revised final plat (required after P&Z approval); and One (1) copy of the digital file of the final plat on diskette or e-mail to: pdsdigitalsubmittal(cDcstx.gov. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://www.csb(.gov/pz Please note that a Mylar original of the revised final plat will be required after P&Z approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments cc: Randy Lowry, Creek Meadows Partners, LP; via email: chris@oldhamgoodwin.com Case file #12-00500192 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 1 of 4 STAFF REVIEW COMMENTS NO. 1 Project: CREEK MEADOWS SEC 4 PH 3A & 4 (FP) - 12-00500192 PLANNING 1. As previously discussed, these phases exceed the capacity of the existing lift station. Lift station improvements need to be included with this plat or the application for Section 3 Phase 1 needs to be withdrawn so the capacity is not exceeded. There are two options to continue without immediately expanding the lift station: 1) withdraw the Section 3 Phase 1 application so that these phases replace the capacity taken by it, or 2) provide on separate letterhead that the lift station improvements will need to occur with or prior Section 3 Phase 1 being able to proceed to the Planning & Zoning Commission for approval. 2. Please note that as stated on staff comment memos, a 90-day expiration applies to inactive projects. Though this has occurred with the Section 3 Phase 1 application, staff is willing to renew the 90-day expiration for the project but it will expire on December 31, 2012 if progress has not been made on revising the construction documents or moving the project forward. 3. Please update the Certificate of Ownership to include the final sentence reading "All such dedications shall be in fee simple unless expressly provided otherwise." 4. Please update the Approval of Planning and Zoning certificate to read "Certificate of Planning and Zoning Commission". 5. Please provide the number of lots that are proposed in these phases in the title block. 6. Please update the following lot information according to Brazos CAD: • Adjoiner Lot #5 is owned by Sarah and Chris Foster; • Tom Townsend's lot, located to the northwest of Phase 4 is 1.5 acres; • The lot abutting Tom Townsend's lot is currently owned by Cemetery Free Will Workers and is 0.78 acres, • The lot shown to be owned by Matron Grays is currently owned by Byron Grays. • The lot abutting Phase 3A & 4 to the west is currently owned by Brazos County and is 3.698 acres. Reviewed by: Morgan Hester ENGINEERING Date: September 13, 2012 Final Plat 1. It looks like additional private drainage easements may be needed for cross -lot drainage along the rear of lots 52-63 and lots 46-49. 2. Please show lot corners tied to City horizontal control monuments. 3. The private drainage easement along the rear of lots 32-41 should be labeled as a 20-ft. 4. FYI ... All public infrastructure is required to be built or surety provided for it prior to this plat being scheduled for a P&Z meeting. 5. FYI ... Since Phases 3A and 4 are being reviewed and permitted together, they will need to be constructed and completed together as well. Separate Letters of Completion will not be issued. Construction Documents 1. Please submit a Letter of Acknowledgment. 2. FYI... Additional Development Permit Fee in the amount of 1 % of the total public infrastructure cost will be required. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 4 3. The title on each sheet needs to reference Section 4, Phase 3A & 4. 4. Since there are more than 30 lots off of a single access point, a secondary emergency access is necessary. FYI ... A temporary emergency access easement needs to be dedicated prior to final plat approval. 5. GN-01 — The street sign details are not legible. 6. Please include all 2012 City Standard Details. 7. EC-01 — The hydro -seeding note is a bit confusing. Are all areas supposed to be hydro - seeded or only the shaded areas? Please also reference our hydro -seeding spec. 8. GP-01 —Note #4 should reference these current sections. 9. GP-01 — How will cross -lot drainage be handled? Please provide a detail of proposed swale or private storm. If a swale is proposed, how will obstructions be prevented from being built to block drainage? 10. ST-01 — It looks like there should also be ramps on the east side of Lowry Meadow Ln. for pedestrians crossing the street at that intersection. 11. ST-01 — At existing Junction Box #5, please label the flowlines in and out. 12. ST-02 — Please provide a detail for the 3 reflective warning signs on Shallow Creek Ct. 13. ST-02 — All RCP with less than 2-ft of cover needs to be Class IV. 14. ST-02 — Please use City Standard Details for sidewalk ramps. 15. ST-02 — Along Quartz Creek Ct. the ramp note references Cow Creek Ct. 16. W-01/02 —Waterline material needs to be C900. 17. W-01 — Why are water services at cul-de-sac arched? Please verify that this will not have a negative effect on water service to those homes. 18. W-01 — Please indicate how far the nearest fire hydrant is in the adjacent section. 19. S-01 — Please provide an outside drop at MH #108 and label the service flowlines. 20. S-01 — At Water/Sewer crossings, please reference special TCEQ requirements. 21. S-02 — At MH #110, label the service flowline and verify that an external drop is not needed. 22. Sanitary Sewer Report — On pages 3, 4, & 6, please update to reference the correct section and phase. 23. Drainage Report — Please verify that the maximum ponding is not being exceeded at Inlet A15. 24. Drainage Report — Please provide velocities in the streets. 25. Drainage Report — Please verify that sump inlet capacities were reduced by 10% to account for clogging. Reviewed by: Erika Bridges Date: September 26, 2012 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION This project location is outside of CSU certification area. CSU will not provide electric service to this project location. GENERAL ELECTRICAL 1. To discuss any of the above electrical comments please contact Gilbert Martinez at 979.764.6255 Reviewed by: Gilbert Martinez Date: September 12, 2012 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3 of 4 SANITATION 1. Sanitation is ok with this project. Reviewed by: Wally Urrutia Date: September 12, 2012 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 4 of 4 (_ 4IW4� CITY OF COI7.F.GF. STATION Home ofTe A&M Unio ity' 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM January 2, 2013 TO: Rabon Metcalf, RME Consulting Engineers; via email: rabon@rmengineer.com FROM: Morgan Hester, Staff Planner SUBJECT: CREEK MEADOWS SEC 4 PH 3A & 4 (FP) - Final Plat Staff reviewed the above -mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted, your project will be placed on the next available Planning and Zoning Commission meeting held in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24"x36" copy of the revised final plat; Thirteen (13) 11 "x17" copies of the revised final plat; One (1) Mylar original of the revised final plat (required after P&Z approval); and One (1) copy of the digital file of the final plat on diskette or e-mail to: pdsdigitalsubmittal(cDcstx.gov. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://www.csb(.gov/pz Please note that a Mylar original of the revised final plat will be required after P&Z approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments cc: Randy Lowry, Creek Meadows Partners, LP; via email: chris@oldhamgoodwin.com Case file #12-00500192 STAFF REVIEW COMMENTS NO. 2 Project: CREEK MEADOWS SEC 4 PH 3A & 4 (FP) - 12-00500192 PLANNING Repeat: As previously discussed, these phases exceed the capacity of the existing lift station. Lift station improvements need to be included with this plat or the application for Section 3 Phase 1 needs to be withdrawn so the capacity is not exceeded. There are two options to continue without immediately expanding the lift station: 1) withdraw the Section 3 Phase 1 application so that these phases replace the capacity taken by it, or 2) provide on separate letterhead that the lift station improvements will need to occur with or prior Section 3 Phase 1 being able to proceed to the Planning & Zoning Commission for approval. Reviewed by: Morgan Hester ENGINEERING Final Plat Date: December 27. 2012 1. (Repeat) It looks like additional private drainage easements may be needed for cross -lot drainage along the rear of lots 52-63 and lots 46-49. It is not clear whether or not the 20-ft PUE at the rear of Lots 46-48 is also a Private Drainage Easement. 2. (Repeat) The private drainage easement along the rear of lots 32-41 should be labeled as a 20-ft. 3. (Repeat) FYI ... All public infrastructure is required to be built or surety provided for it prior to this plat being scheduled for a P&Z meeting. 4. (Repeat) FYI ... Since Phases 3A and 4 are being reviewed and permitted together, they will need to be constructed and completed together as well. Separate Letters of Completion will not be issued. Construction Documents 1. (Repeat) Please submit a Letter of Acknowledgment. 2. (Repeat) FYI... Additional Development Permit Fee in the public infrastructure cost will be required. 3. (Repeat) The title on each sheet needs to reference Section 4. (Repeat) Since there are more than 30 lots off of a single amount of 1 % of the total 4, Phase 3A & 4. access point, a secondary emergency access is necessary. FYI ... A temporary emergency needs to be dedicated prior to final plat approval. access easement 5. (Repeat) GN-01 — The street sign details are not legible. 6. (Repeat) Please include all 2012 City Standard Details. 7. (Repeat) EC-01 — The hydro -seeding note is a bit confusing. Are all areas supposed to be hydro -seeded or only the shaded areas? Please also reference our hydro -seeding spec. 8. (Repeat) GP-01 —Note #4 should reference these current sections. 9. (Repeat) GP-01 — How will cross -lot drainage be handled? Please provide a detail of proposed swale or private storm. If a swale is proposed, how will obstructions be prevented from being built to block drainage? 10. (Repeat) ST-01 — It looks like there should also be ramps on the east side of Lowry Meadow Ln. for pedestrians crossing the street at that intersection. 11. (Repeat) ST-01 — At existing Junction Box #5, please label the flowlines in and out. 12. (Repeat) ST-02 — Please provide a detail for the 3 reflective warning signs on Shallow Creek Ct. 13. (Repeat) ST-02 — All RCP with less than 2-ft of cover needs to be Class IV. 14. (Repeat) ST-02 — Please use City Standard Details for sidewalk ramps. 15. (Repeat) ST-02 — Along Quartz Creek Ct. the ramp note references Cow Creek Ct. 16. (Repeat) W-01/02 — Waterline material needs to be C900. 17. (Repeat) W-01 — Why are water services at cul-de-sac arched? Please verify that this will not have a negative effect on water service to those homes. 18. (Repeat) W-01 — Please indicate how far the nearest fire hydrant is in the adjacent section. 19. (Repeat) S-01 — Please provide an outside drop at MH #108 and label the service flowlines. 20. (Repeat) S-01 — At Water/Sewer crossings, please reference special TCEQ requirements. 21. (Repeat) S-02 — At MH #110, label the service flowline and verify that an external drop is not needed. 22. (Repeat) Sanitary Sewer Report — On pages 3, 4, & 6, please update to reference the correct section and phase. 23. (Repeat) Drainage Report — Please verify that the maximum ponding is not being exceeded at Inlet A15. 24. (Repeat) Drainage Report — Please provide velocities in the streets. 25. (Repeat) Drainage Report — Please verify that sump inlet capacities were reduced by 10% to account for clogging. Reviewed by: Erika Bridges Date: January 2, 2013 (* F"" CITY OF COLLEGE STATION Home ofTe A&M UW.v iry' MEMORANDUM January 31, 2013 TO: Rabon Metcalf, RIME Consulting Engineers, via email: rabon@rmengineer.com FROM: Morgan Hester, Staff Planner SUBJECT: CREEK MEADOWS SEC 4 PH 3A & 4 (FP) - Final Plat Staff reviewed the above -mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted, your project will be placed on the next available Planning and Zoning Commission meeting held in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24'k36" copy of the revised final plat, Thirteen (13) 11"x17" copies of the revised final plat, One (1) Mylar original of the revised final plat (required after P&Z approval), and One (1) copy of the digital file of the final plat on diskette or e-mail to: AsdioitalsubmittalO,cstx. goy. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http:/Ayww.cstx.gov/pz Please note that a Mylar original of the revised final plat will be required after P&Z approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Randy Lowry, Creek Meadows Partners, LP; via email: chris@oldhamgoodwin.com Case file #12-00500192 Placeixg&Developm Services P.O. BOX 9960 • 1101 TEXAS AVENUE • COLLEGE STATION • TEXAS • 77942 TEL. 979.764.3570 • FAX. 979.764.3496 csa.gov/Aevservices STAFF REVIEW COMMENTS NO. 3 Project: CREEK MEADOWS SEC 4 PH 3A & 4 (FP) - 12-00500192 PLANNING 1. Please be aware that Project #12-00500263 must be approved before this plat can be put on the agenda for a future Planning & Zoning meeting. Reviewed by: Morgan Hester ENGINEERING COMMENTS NO. 3 Date: January 15, 2013 Final Plat 1. (Repeat) The private drainage easement along the rear of lots 32-41 should be labeled as a 20-ft. This is still labeled as a 10-ft easement. Construction Documents 1. (Repeat) Please submit a Letter of Acknowledgment. 2. (Repeat) FYI... Additional Development Permit Fee in the amount of 1 % of the total public infrastructure cost will be required. Please submit updated cost estimate. 3. (Repeat) Please include all 2012 City Standard Details. 4. (Repeat) GP-01 — How will cross -lot drainage be handled? Please provide a detail of proposed swale or private storm. If a swale is proposed, how will obstructions be prevented from being built to block drainage? Please provide updated storm sheets showing the private drainage. 5. (Repeat) ST-02 — All RCP with less than 2-ft of cover needs to be Class IV. We require Class IV RCP unless documentation can be provided showing the equivalence of Class III with cement stabilized bedding. Reviewed by: Erika Bridges Date: January 28, 2013