HomeMy WebLinkAboutAccess Drive - Drainage LetterKLING ENGINEERING & SURVEYING A Division of Civil Engineering Consultants 4101 Texas Avenue, Suite A Bryan, Texas 77802 Telephone 979/846-6212 Fax 979/846-8252 S.M. Kling, R.P.L.S. Fred Paine, P.E., CFM September 7, 2012 To: City of College Station, Development Engineering c/o Erika Bridges, Engineer From: Fred Paine, P.E. Re: Lots 9 & 10, Block 3, Tower Point Phase 11B Access Drive - Drainage Letter Post Office Box 4234 Bryan, Texas 77805 As a result of the proposed access drive construction, revisions to the existing storm sewer system are required. The purpose of this memo is to document the proposed storm sewer revisions will be consistent with existing conditions and to document the capacity of the proposed additional run of storm sewer connecting pipe. Storm Sewer Inlets: Existing Conditions Approximate Station 0+20 / 18' left Width of depressed gutter - 2' Gutter depression - 4" (assumed) Length of curb opening - 5' Street longitudinal slope - 1.2% Street cross slope - 2.7% per the access drive plan (Inlet 1): Approx. Drainage Area: 0.124 ac w/ Tc <10 min; 10 min used Assumed full development C-factor 0.90 (grassed median removed) Approximate Station 2+18 / 9' right per the access drive plan (Inlet 2): Width of depressed gutter - 2' Gutter depression - 4" (assumed) Length of curb opening - 5' Street longitudinal slope - 1.6% Street cross slope - 3.0% Approx. Drainage Area: 1.196 ac w/ Tc <10 min; 10 min used C-factor(ave): 0.84 Proposed Conditions Approximate Station 0+20 / 60' right Width of depressed gutter - 2' Gutter depression - 4" Length of curb opening - 5' Street longitudinal slope - 1.3% Street cross slope - 3.1% per the access drive plan (Inlet 1R): Approx. Drainage Area: 0.124 ac w/ Tc <10 min; 10 min used Assumed full development C-factor 0.90 (grassed median removed) pg 1 of 3 Proposed Conditions - continued Approximate Station 2+32 / 36' left per the access drive plan (Inlet 2R): Width of depressed gutter - 2' Gutter depression - 4" Length of curb opening - 5' Street longitudinal slope - 1.6% Street cross slope - 3.0% Approx. Drainage Area: 1.196 ac w/ Tc <10 min; 10 min used C-factor(ave): 0.84 The rational method was used to estimate the stormwater gutter flows. Based on the short time of concentration, the 25 year rainfall intensity is calculated to be 9.86 in/hr. The following table summarizes gutter flows & inlet capacities for the 25 year event. Inlet Q25 (cfs) Gutter Flow Water Spread (ft) Gutter Flow Depth (ft) Length of Curb Inlet (ft) Intercepted Flow (cfs) Carry Over (cfs) 1 1.16 5.9 0.22 5 1.04 0.12 1R 2.84 7.63 0.29 10 2.72 0.12 2 9.91 11.98 0.42 5 3.22 6.69 2R 9.91 11.98 0.42 5 3.22 6.69 Table 1 Inlets at the existing inlet locations will be converted to grate inlets with the tops set at proposed finished driveway grade. The grates chosen are pedestrian safe and therefore provide little runoff interception. Grate capacity was considered insignificant and therefore not included in capacity calculations. Storm Sewer Pipe: The relocated inlet at approximate station 2+32 / 36' left will require a connecting pipe to the converted grate inlet. The connecting pipe will be an 18" RCP installed at 7%. Capacity of the proposed 18" connecting pipe is 27.8 cfs, contributing runoff is 3.22 cfs (portion of runoff intercepted by inlet 2R). pg 2 of 3 Conclusions: The relocated inlets provide for the same runoff interception as the existing conditions inlets. The connecting storm sewer pipe from relocated inlet 2R to existing inlet 2 is adequate to convey the storm water runoff received by inlet 2R. No adverse affects are anticipated upstream or downstream due to the storm sewer revisions. Certification: This report & plan for the drainage design of the Tower Point Phase 11 B, Lots 9 & 10 access drive was prepared under my supervision in accordance with the provisions of the Bryan / College Station Unified Drainage Design Guidelines for the Owners of the property. All licenses and permits required by any and all state and federal regulatory agencies for the proposed drainage improvements have been issued. • ALFRED A. PAINE 97221 State of Texas No.: 97221 Texas Engineering Firm No. F-2214 pg3of3 Gutter Flow - Inlet 1 - 25 yr Worksheet for Irregular Channel Project File h:\ei6lrv-4\tpfrn7-2\p506ga-u\atfgn9-b\street.fm2 Worksheet 1/2 STREET SECTION -INLET 1-EXISTING Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.012000 ft/ft Elevation range: 300.73 ft to 301.50 ft. Station (ft) Elevation (ft) Start Station End Station Roughness -11.50 301.50 -11.50 12.50 0.013 0.00 301.23 1.00 301.23 1.00 300.73 2.00 300.82 12.50 301.10 Discharge 1.16 cfs Results Wtd. Mannings Coefficient 0.013 Water Surface Elevation 300.95 ft Flow Area 0.50 ft? Wetted Perimeter 6.12 ft Top Width 5.90 ft Height 0.22 ft Critical Depth 300.98 ft Critical Slope 0.005641 ft/ft Velocity 2.34 ft/s Velocity Head 0.09 ft Specific Energy 301.04 ft Froude Number 1.42 Flow is supercritical. 09/08/12 RowMaster v5.12 11:23:08 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Cross Section Cross Section for Irregular Channel Project Description Project File h:\ei6lrv-4\tpfrn7-2\p506ga-u\atfgn9-b\street.fm2 Worksheet 1/2 STREET SECTION -INLET 1-EXISTING Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Section Data Wtd. Mannings Coefficient 0.013 Channel Slope 0.012000 ft/ft Water Surface Elevation 300.95 ft Discharge 1.16 cfs 301.4 301.3 301.2 c 301.1 m N W 301.0 300.9 300.8 300.7 -15.0 -1 0.0 -5.0 0.0 5.0 10.0 Station (ft) 09/08/12 11:22:23 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 FlowMaster v5.12 Page 1 of 1 Gutter Flow - Inlet 2 - 25 yr Worksheet for Irregular Channel Project Description Project File h:\ei61rv-4\tpfrn7-2\p506ga-u\atfgn9-b\street.fm2 Worksheet 1/2 STREET SECTION -INLET 2-EXISTING Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.016000 ft/ft Elevation range: 300.73 ft to 301.51 ft. Station (ft) Elevation (ft) Start Station -11.50 301.50 -11.50 0.00 301.23 1.00 301.23 1.00 300.73 2.00 300.82 25.00 301.51 Discharge 9.91 cfs Results Wtd. Mannings Coefficient 0.013 Water Surface Elevation 301.15 ft Flow Area 2.18 ft' Wetted Perimeter 12.41 ft Top Width 11.98 ft Height 0.42 ft Critical Depth 301.26 ft Critical Slope 0.004300 ft/ft Velocity 4.54 ft/s Velocity Head 0.32 ft Specific Energy 301.47 ft Froude Number 1.87 Flow is supercritical. End Station Roughness 25.00 0,013 09/08/12 FlowMaster v5.12 11:26:38 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Inlet 2 Cross Section for Irregular Channel Project Description Project File h:\ei6lrv-4\tpfrn7-2\p506ga-u\atfgn9-b\street.fm2 Worksheet 1/2 STREET SECTION -INLET 2-EXISTING Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Section Data Wtd. Mannings Coefficient 0.013 Channel Slope 0.016000 ft/ft Water Surface Elevation 301.15 ft Discharge 9.91 cfs 301 301 301 301 c 0 Y as 301 W 301 300 300 300.. -15.0 -10.0 -5.0 0.0 5.0 10.0 15.0 20.0 Station (ft) 25.0 09/08/12 FlowMaster v5.12 11:26:16 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Gutter Flow - Inlet 1 R - 25 yr Worksheet for Irregular Channel Project Description Project File h:\ei61rv-4\tpfrn7-2\p506ga-u\atfgn9-b\street.fm2 Worksheet 1/2 STREET SECTION -INLET 1R-PROPOSED Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.013000 ftift Elevation range: 300.73 ft to 301.50 ft. Station (ft) Elevation (ft) Start Station End Station Roughness -11.50 301.50 -11.50 12.50 0.013 0.00 301.23 1.00 301.23 1.00 300.73 2.00 300.82 12.50 301.14 Discharge 2.84 cfs Results Wtd. Mannings Coefficient 0.013 Water Surface Elevation 301.02 ft Flow Area 0.92 ft' Wetted Perimeter 7.93 ft Top Width 7.63 ft Height 0.29 ft Critical Depth 301.07 ft Critical Slope 0.004942 ft/ft Velocity 3.09 ft/s Velocity Head 0.15 ft Specific Energy 301.17 ft Froude Number 1.57 Flow is supercritical. 09/08/12 FlowMaster v5.12 11:24:28 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Inlet 1 R Cross Section for Irregular Channel Project Description Project File h:\ei6lrv-4\tpfrn7-2\p506ga-u\atfgn9-b\street.fm2 Worksheet 1/2 STREET SECTION -INLET 1 R-PROPOSED Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Section Data Wtd. Mannings Coefficient 0.013 Channel Slope 0.013000 ft/ft Water Surface Elevation 301.02 ft Discharge 2.84 cfs 301.4 301.3 301.2 x c 0 301.1 m 0 W 301.0 300.9 300.8 300.7 -15.0 -10.0 -5.0 0.0 5.0 10.0 Station (ft) 15.0 09/08/12 11:24:15 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 FlowMaster v5.12 Page 1 of 1 Gutter Flow - Inlet 2R - 25 yr Worksheet for Irregular Channel Project Description Project File h:\ei6lrv-4\tpfrn7-2\p506ga-u\atfgn9-b\street.fm2 Worksheet 1/2 STREET SECTION -INLET 2R-PROPOSED Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Input Data Channel Slope 0.016000 ft/ft Elevation range: 300.73 ft to 301.51 ft. Station (ft) Elevation (ft) Start Station End Station Roughness -11.50 301.50 -11.50 25.00 0.013 0.00 301.23 1.00 301.23 1.00 300.73 2.00 300.82 25.00 301.51 Discharge 9.91 cfs Results Wtd. Mannings Coefficient 0.013 Water Surface Elevation 301.15 ft Flow Area 2.18 ft' Wetted Perimeter 12.41 ft Top Width 11.98 ft Height 0.42 ft Critical Depth 301.26 ft Critical Slope 0.004300 ft/ft Velocity 4.54 ft/s Velocity Head 0.32 ft Specific Energy 301.47 ft Froude Number 1.87 Flow is supercritical. 09/08/12 FlowMaster v5.12 11:27:40 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Inlet 2R Cross Section for Irregular Channel Project Description Project File h:\ei6lrv-4\tpfrn7-2\p506ga—u\atfgn9—b\street.fm2 Worksheet 1/2 STREET SECTION -INLET 2R-PROPOSED Flow Element Irregular Channel Method Manning's Formula Solve For Water Elevation Section Data Wtd. Mannings Coefficient 0.013 Channel Slope 0.016000 ft/ft Water Surface Elevation 301.15 ft Discharge 9.91 cfs 301.5 301.4 301.3 $ 301.2 C 0 as 301.1 W 301.0 300.9 300.8 300.7 -15.0 -10.0 -5.0 0.0 5.0 10.0 15.0 20.0 Station (ft) 25.0 09/08/12 FlowMaster v5.12 11:27.21 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 INLET CALCULATIONS Existing Storm Sewer Inlet Sta 0+20 (Inlet 1) Gutter Flow: (cfs) Q10 1.02 Q25 1.16 Q100 1.37 Inlet on Grade 10 yr Eo: 0.69 Se: 0.14 Lx: 7.02 Carryover Flow: 10 yr Qco: 0.11 25 yr Qco: 0.12 100 yr Qco: 0.15 Depth Spread (ft) (ft) 0.21 5.6 0.22 5.9 0.23 6.31 Gutter Depression: 0.33 25 yr 100 yr Eo: 0.67 Eo: Se: 0.14 Se: Lx: 7.55 Lx: Intercepted Flow: 0.91 cfs 1.04 cfs 1.23 cfs Width of Depressed Gutter: 0.64 0.13 8.28 Li=5 ft AREA: 0.124 ac Q=CiA C Factor 0.95 i10 8.63 in/hr Q10 1.02 cfs i25 9.86 in/hr Q25 1.16 cfs 100 11.64 in/hr Q100 1.37 cfs Existing Storm Sewer Inlet Sta 2+18 (Inlet 2) Gutter Flow Q10 Q25 Q100 Inlet on Grade: 10 yr Eo: Se: Lx: Carryover Flow: 10 yr Qco: 25 yr Qco: 100 yr Qco: (cfs) 8.67 9.91 11.69 0.40 0.10 23.68 5.66 6.69 8.20 Depth Spread (ft) (ft) 0.4 11.39 0.42 11.98 0.44 12.76 Gutter Depression: 0.33 25 yr 100 yr Eo: 0.39 Eo: Se: 0.09 Se: Lx: 25.49 Lx: Intercepted Flow: 3.01 cfs 3.22 cfs 3.50 cfs Width of Depressed Gutter: 0.37 0.09 27.93 Li=5 ft AREA: 1.196 ac Q=CiA C Factor 0.84 i10 8.63 in/hr Q10 8.67 cfs i25 9.86 in/hr Q25 9.91 cfs i100 11.64 in/hr Q100 11.69 cfs ►a Carry Over Flow Equation Qco=Q((1-(La/Lr))A1.8 Cave 0.991 8.09 0.205 E Carry Over Flow Equation Qco=Q((1-(La/Lr))A1.8 Cave 0.991 0.84 0.205 INLET CALCULATIONS Proposed Storm Sewer Inlet Sta 0+20 (inlet 1R) Gutter Flow: (cfs) Q10 2.48 Q25 2.84 Q100 3.35 Inlet on Grade: 10 yr Eo: 0.58 Se: 0.13 Lx: 11.19 Carryover Flow: 10 yr Qco: 0.04 25 yr Qco: 0.12 100 yr Qco: 0.26 Depth Spread (ft) (ft) 0.28 7.24 0.29 7.63 0.31 8.14 Gutter Depression: 0.33 25 yr 100 yr Eo: 0.56 Eo: Se: 0.12 Se: Lx: 12.05 Lx: Intercepted Flow: 2.44 cfs 2.72 cfs 3.09 cfs Width of Depressed Gutter: 0.53 0.12 13.21 Li=10 ft AREA: 0.303 ac Q=CiA C Factor 0.95 i10 8.63 in/hr Q10 2.48 cfs i25 9.86 in/hr Q25 2.84 cfs i100 11.64 in/hr Q100 3.35 cfs Proposed Storm Sewer Inlet Sta 2+32 (Inlet 2R) Gutter Flow: (cfs) Q10 8.67 Q25 9.91 Q100 11.69 Inlet on Grade: 10 yr Eo: 0.40 Se: 0.10 Lx: 23.68 Carryover Flow: 10 yr Qco: 5.66 25 yr Qco: 6.69 100 yr Qco: 8.20 Depth Spread (ft) (ft) 0.4 11.39 0.42 11.98 0.44 12.76 Gutter Depression: 0.33 25 yr 100 yr Eo: 0.39 Eo: Se: 0.09 Se: Lx: 25.49 Lx: Intercepted Flow: 3.01 cfs 3.22 cfs 3.50 cfs Width of Depressed Gutter: 0.37 0.09 27.93 Li=5 ft AREA: 1.196 ac Q=CiA C Factor 0.84 i10 8.63 in/hr Q10 8.67 cfs i25 9.86 in/hr Q25 9.91 cfs i100 11.64 in/hr Q100 11.69 cfs 2 Carry Over Flow Equation Qco=Q((1-(La/Lr))A1.8 V: Carry Over Flow Equation Qco=Q((1-(La/Lr))A1.8 Cave 0.991 0.84 0.205 18" RCP Worksheet for Circular Channel Project Description Project File h:\ei6lrv-4\tpfrn7-2\p506ga-u\atfgn9-b\street.fm2 Worksheet 18" Storm Flow Element Circular Channel Method Manning's Formula Solve For Full Flow Capacity Input Data Mannings Coefficient 0.013 Channel Slope 0,070000 ft/ft Diameter 18.00 in Results Depth 1.50 ft Discharge 27.79 cfs Flow Area 1.77 ft2 Wetted Perimeter 4.71 ft Top Width 0.00 ft Critical Depth 1.49 ft Percent Full 100.00 Critical Slope 0.065645 ft/ft Velocity 15.73 ft/s Velocity Head 3.84 ft Specific Energy FULL ft Froude Number FULL Maximum Discharge 29.89 cfs Full Flow Capacity 27.79 cfs Full Flow Slope 0,070000 ft/ft 09/08/12 FlowMaster v5.12 11:18:43 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1