HomeMy WebLinkAboutStaff CommentsCITY OF COLLEGE STATION Nome ofTexm A6-M University' 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM May 16, 2012 TO: Brian Stanton via email: brian.stanton@carriageservices.com FROM: Lauren A. Hovde, Staff Planner SUBJECT: 4080 STATE HIGHWAY 6 — PDD Rezoning Staff reviewed the above -mentioned rezoning as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address all comments and submit the following information by any Monday for your project to be placed on the next available Planning & Zoning Commission (P&Z): One (1) 24"x36" copy of the revised Rezoning Map and Concept Plan; Thirteen (13) 11'k17" copies of the revised Rezoning Map and Concept Plan; One (1) copy of the revised Metes and Bounds; One (1) copy of the digital file of the revised rezoning Metes & Bounds on diskette or e-mail to P&DS_Digital_Submittal@cstx.gov. If all required items are not received, your project will be not be scheduled on the P&Z agenda. Your project may be placed on a future agenda once all comments have been addressed and the appropriate re -advertising fees paid. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://www.csb(.gov/pz If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments PC: Dahlis Waller via postal mail Joe Schultz, P.E. via email: joeschultz84@verizon.net Case file #12-00500084 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 1 of 3 STAFF REVIEW COMMENTS NO. 1 Project: 4080 STATE HIGHWAY 6 S (REZ) — (12-00500084) PLANNING 1. The application states that the requested zoning district is C-1. I will correct this to read PDD, if requested. The following comments are related to the Rezoning Map: 1. There will be a right-of-way dedication required along Longmire when that portion of the property plats. 2. Please revise the vicinity map to include the whole property. 3. There are several easements that are mentioned in the notes. Please clarify why they are not shown, even if the development in not impacted. The explanation was unclear. 4. Please revise the proposed zoning district to PDD Planned Development District instead of PD Planned District. The following comments are related to the Concept Plan: 1. Please show the required sidewalk along Hwy 6 or include this requirement as a waiver request (UDO Section 8.2.K.3.a). 2. Since a waiver is being sought to the block length requirements, an additional waiver request to UDO Section 8.2.E.3 Street Projections is needed as well. 3. Since the block is over 900 linear feet along both rights -of -way, an access way for pedestrian connection is required per LIDO Section 8.2.J Access Ways. If a waiver is sought to the sidewalk requirement, a possible additional waiver may be to this requirement as well. 4. Please clarify if the waiver request to LIDO Section 7.5.D is for Longmire and Hwy 6, or just Longmire. 5. There are many C-1 land uses that are not appropriate for Suburban Commercial, in addition C-1 in not appropriate in that land use designation. A more appropriate alternative would be to request C-3 as a base zoning with additional land uses as desired (such as funeral home). Please specifically exclude crematoriums from this land use list. 6. Please consider reducing the Neighborhood Commercial/Office maximum height to 35 feet to be consistent with max single-family height restrictions. 7. FYI... If a Public Way is required, an easement would be dedicated in the plat and the construction could be delayed until site planning that phase. I received additional information that allows me to share this with you now. 8. FYI ... All of Waller Tract will be considered one building plot for signage, Non -Residential Architectural Standards, and landscaping at the time of platting. 9. Please show the proposed access points from Hwy 6 and Longmire. The drive on Longmire needs to align with Lakeshore Circle to minimize conflict areas. The Hwy 6 driveway will not meet TxDOT spacing requirements and will require a TxDOT permit. 10. A cross access easement parallel to Hwy 6 is required to connect to the properties directly north and south of the subject tract. This is not constructed until site planning. 11. Please label the intended phases of the development. 12. Please show where artificially lighting will be located, or address potential lighting methods to assure compatibility with the neighborhood. 13. The owner and developer's phone numbers need to be added to be title block. The development address may also be added (4080 State Highway 6). FYI... This is not a permanent address. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 3 14. Please discuss the treatment of the proposed detention pond. Poorly treated or maintained detention ponds can detract from a neighborhood. 15. Please provide a range of building square footages and a maximum overall total square footage of the building plot. 16. A residential pitch on the roof does need to be provided according to language found in the Comprehensive Plan when describing Suburban Commercial. In addition, please provide additional information regarding how the architectural design will be similar to that found in the nearby neighborhoods. For instance, the reference to a main material being stucco/EFIS would not provide this compatibility. Accents of material may be similar to residential units in the area. FYI... The design will still be required to comply with LIDO Section 7.9 Non -Residential Architectural Standards. 17. Evaluation of the waiver requests to determine Staff's recommendation will continue through the next submittal. Reviewed by: Lauren A. Hovde, Staff Planner Date: May 15, 2012 TxDOT Comments 1. Any future access drives will be required to meet TxDOT's current "Regulations for Access Driveways to State Highways". Location must consider the posted speed and the distance between existing, proposed and adjacent access points. Reviewed by: Chad Bohne Date: April 26, 2012 TRANSPORTATION 1. The Traffic Impact Analysis threshold has been exceeded with the current land use and square footage currently proposed. One way to get a clearer picture of the trips to be generated that could potentially bring the trips generated to below the TIA threshold is to provide square footage for the proposed funeral home facility. Funeral home facilities generate relatively low trips during the peak hour. 2. Access to the SH 6 southbound frontage road will have to meet TxDOT spacing requirements 425' for 50 mph and above. 3. As you are aware, current block length requirements at 900' will put a public way or a public street within the subject tract. Meeting the block length requirement will provide access and connectivity to the subject tract from both Longmire and SH 6. Meeting block length will also provide access for southbound and northbound traffic. Southbound traffic along SH 6 will only be accommodated if block length is not met making access and connectivity problematic for the subject tract. Reviewed by: Joe Guerra, AICP, PTP, Transportation Planning Coord. Date: 5/16/2012 ENGINEERING COMMENTS NO. 1 1. Please verify there is not a 100-ft Electrical Easement (V.633, P.593) adjacent to the SH6 Feeder Rd. Reviewed by: Erika Bridges Date: 5/14/12 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3 of 3 (* OrW4" CITY OF COLLEGE STATION Home of Tam A6M Unioenity' 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM May 29, 2012 TO: Brian Stanton via email: brian.stanton(cDcaniageseryices. com FROM: Lauren A. Hovde, Staff Planner SUBJECT: 4080 State Highway 6 S (REZ) — Rezoning Comments #2 Staff reviewed the above -mentioned rezoning as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address all comments and submit the following information by Tuesday, June 5, 2012, 10:00 a.m., for your project to be placed on the next available Planning & Zoning Commission (P&Z) meeting scheduled for June 21, 2012, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue: One (1) 24"x36" copy of the revised Concept Plan (page 2 only); Thirteen (13) 11'k17" copies of the revised Concept Plan (page 2 only); One (1) copy of the revised Metes and Bounds of the 7.547 acre tract; One (1) copy of the digital file of the revised rezoning Metes & Bounds on diskette or e-mail to P&DS_Digital_Submittal@cstx.gov. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If all required items are not received, your project will be not be scheduled on the P&Z agenda. Your project may be placed on a future agenda once all comments have been addressed and the appropriate re -advertising fees paid. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://www.csb(.gov/pz If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments cc: Dahlis Waller via postal mail Joe Schultz, P.E. via email: joeschultz84@verizon.net NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 1 of 3 STAFF REVIEW COMMENTS NO. 2 Project: 4080 STATE HIGHWAY 6 S (REZ) — (12-00500084) PLANNING 1. A flat roof, as referenced in the Note 6, is not consistent with the Suburban Commercial designation. In addition, please make the architectural features of the building measurable. For instance, what will be the range of slope for the roof (suggestions: 4:12 to 8:12). What percentage of materials will be used on facades (if exceeding NRA standards)? Specify what building materials will be used. Please specify the architectural relief elements to be used, outside of the pre -approved elements in the NRA section of the UDO. Examples: a. Decorative window shutters; b. Covered front porch (extending along at least 50% of building fagade and projecting a minimum of 4 feet from the face of the building); c. Eaves in excess of 18 inches; d. Window planter boxes; e. Window canopy; f. Dormers; g. Transom windows; h. Decorative fagade lighting; i. Chimneys or cupolas. 2. Please specify that the height will be measured from peak of roof. 3. Please provide language that states that the dumpster will be located in an area away from the residential uses. 4. Please provide foundation landscaping as a site attribute that increases compatibility with the neighboring residences. Reviewed by: Lauren A. Hovde, Staff Planner Date: May 22, 2012 ENGINEERING COMMENTS NO. 2 1. Please revise Note #3 to state that drainage will be in accordance with the B/CS Unified Stormwater Design Guidelines. Reviewed by: Erika Bridges Date: May 24, 2012 TRANSPORTATION No comments. As development occurs on -site, the 50,000 square foot maximum of the building plot must be kept in mind, as well as a change in any intended uses. Reviewed by: Joe Guerra Date: May 29, 2012 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3 of 3 Case file #12-00500084 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 3