HomeMy WebLinkAboutSewer System ReportSewer System Report for College Main Lofts 403 & 408 College Main Block 4, Lot 5 & Block 5, Lot 9 W.C. Boyett Estate Partition Subdivision College Station, Texas March, 2012 4JLhultz Engineering, LLC TBPE Firm No. 12327 P.O. Box 11995 College Station, TX 77842 2730 Longmire Drive, Suite A College Station, Texas 77845 (979)764-3900 !Z F-12327 SCHULTZ ENGINEERING, LLC. General Information Location: The development includes Block 4, Lot 5 and Block 5, Lot 9 in the W.C. Boyett Estate Partition Subdivision on College Main. The project lots are located at 403 and 408 College Main, which is approximately 50 feet northwest of Louise Ave on either side of College Main. General Note: Existing 6" sewer lines run along the back side of each of the lots. A 6" sewer service will connect to the existing lines and extend to each of the buildings at 1.1%. Land Use: Residential — Multi -Family Design Criteria Primary Sewer Outfall: The primary outfall for the services are the 6" lines along the back sides of the lots. Domestic Demand., Peak Flow: The peak flow from each building in this development was determined from the fixture unit counts for each building. These counts are summarized for each proposed building in the spreadsheet provided in Exhibit B. The fixture unit counts were compared to Table 710.1(1) of the Plumbing Code to verify the proposed pipe slope was greater than the minimum slope required by the code. The maximum number of fixture units for a 6" pipe is 700 units and the fixture unit count is 53.2 for 403 College Main and 45.6 for 408 College Main. Pipe: PVC ASTM D 3034 SDR 26 Applicable Exhibits: Exhibit A — Sanitary Sewer System Layout Exhibit B — Fixture Unit Count Determination Conclusion We conclude that the proposed sewer service lines are more than capable of carrying the anticipated flows from each building in the development. Exhibit A Sanitary Sewer System Layout Exhibit B Fixture Unit Count Determination 403 College Main Fixture Count Determination (Plumbing Code) Fixture Unit Value Fixture Type # of Fixtures Load Factor Fixture Units lWashing Machine 7 1.2 8.4 Kitchen Sink 7 1.4 9.8 Dish Washin Machine 7 1.4 9.8 Bathroom Group 71 3.8 1 25.2 Total FsI i w ii -. 11It] 9LiI 408 College Main Fixture Count Determination (Plumbing Code) Fixture Unit Value Fixture Type # of Fixtures Load Factor Fixture Units lWashing Machine 6 1.2 7.2 Kitchen Sink 6 1.4 8.4 Dish WashingMachine 6 1.4 8.4 Bathroom Group6 3.8 21.6 Total = 45.6 Demand = 28 GPM