HomeMy WebLinkAboutSeptic System DesignDAVID PICKENS REGISTERED SANITARIAN SEPTIC SYSTEM DESIGNS 10202 N. DOWLING Rd. COLLEGE STATION, TEXAS 77845 (979)693-8334 February 28,2012 NAME: Tripp Family Trust > vie/ I be) N N ADDRESS: 3803 McCullough Road COUNTY: Brazos ACREAGE: SUBDIVISION/ SURVEY: Wellborn Business Park Lot: 1 Block: 1: Andrew McMahon Survey A —167, Tract: 39 Four (4) buildings of 44' X 80' each, consisting of 4 employees @ 12 GPD each building or GPD est. water usage: 192 GPD/ Effluent Load Rate: 0.045 = 4,266 Sq. ft. of surface irrigation required. Any water usage above 192 GPD will invalidate this design. ACTUAL SQ. FT. OF APPLICATION AREA 6,844 sf New Construction ( X ) Remodel ( ) Water Saving Devices Installed: Yes ( X ) No ( ) Installer: Montel Rutledge 3033 Cain Road College Station, TX 77845 DESIGN PARAMETERS: Trash tank required: Treatment Plant: Pump Tank: Pump: Sprinklers: Chlorinator: Site Evaluation Conducted At Site: Soil Evaluation Conducted At Site: 2 X 500 gallon Cajun -Aire 500 or equivalent 600 gallon 1/2 hp / 1" pvc pipe 6X # 6 Nelson Low Angle nozzles In -line tablet type Yes (X) No( ) Yes (X) No( ) Soil Type: Class IV Area is suitable for Aerobic Spray - Irrigation disposal system: Yes ( X ) No ( ) WATER SUPPLY: Public (X) Private () All set -backs are observed except those noted: night spray — timer required — single disch " +� 3: 00 a.m. f � i rZe FA All counties: AudioNisual high water alarm required on all pump tanks y,..David P. PICki Page 2 February 28, 2012 Tripp Family Trust LANDSCAPING Immediately after completion of installation, property owner must sod with St. Augustine or seed the spray -field with bermuda and rye grass, as necessary, and mow as necessary to maintain optimum growing conditions. Additional irrigation may be required to establish vegetation on disturbed areas. Unless other provisions are made, the property owner is responsible to fill low areas, keep tree shading from preventing grass growth, and maintain proper drainage. UNDER NO CIRCUMSTANCES MAY ANY FOOD CROPS BE PLANTED ON TMS AREA. NOTES: The 600 gallon pump tank will be set to give a daily flow reserve of at least 100 gallons, which will meet or exceed the requirement of 1/3 daily flow. Minimum dose of 200 gallons. This drawing reflects relative distances. Piping from each building to the first tank shall be an approved type. A 2-way clean out will be installed between each building foundation and the trash tank, at each stub out. Additional clean outs as needed. All effluent from these units will be disposed of through aerobic treatment and spray dispersal. The chlorinator may be located in line between the treatment tank and the pump tank, or within the pump tank. All spray fields will be at least 10 feet from property lines. A commercial irrigation timer will be required according to State/County requirements. System must be sampled and tested in accordance with State/County requirements through a sampling port located in the discharge line from the pump to the spray field, which shall be contained within the pump tank. System is designed in accordance with daily water usage described above. Any usage above design will invalidate design. The effluent pump shall be hardwired on a separate circuit from the high water level alarm and all wiring shall be in accordance with National Electric Code, 30 Texas Administrative Code 285.34(b)(4). ei The high water alarm shall be an audible and a visible alarm. All pre -cast concrete tanks will meet ASTM C1227-93a, d30 Texas Administrative Col 5.32(a)(1)(F). Page 3 February 28, 2012 Tripp Family Trust The location for all sprinkler heads may be subject to location modification within reason and so long as they do not violate distance requirements for easements, setbacks or total required spray area covered. Location change will only be considered if more efficient spray dispersal would be achieved due to change. Any changes must be submitted to and approved by the Texas Commission on Environmental Quality or the local Designated Representative. Thank You, David Pickens MS. #2390 10202 N. Dowling Rd College Station, Texas 77845 (979)693-8334 -ZS (Z February 28, 2012 Tripp Family Trust 3803 McCullough Road Brazos Co. Legal: Wellborn Business Park, Lot: 1, Block: 1; Andrew McMahon Survey, A- 167, Tract: 39 Installer: Montel Rutledge Design Parameters: Four (4) buildings of 44' X 80' each, consisting of 4 employees @ 12 GPD each building, with water saving fixtures, on acre tract, Q = 4 employees X 12 GPD X 4 buildings =192 GPD, Ra = 0.045 A = Q / Ri =192 GPD / 0.045 = 4,266 sf required A = 75' X 140' / 2 = 5,250 A designed --1-S''jZ 130'30' 30' C cam — N O OD dam' O CD X 294 8' sch 40 sleeve under drives, Tripp Family Trust \ McCullogh Rd. 0 tea. r ��oo' PICKENS ENVIRONMENTAL and waterline crossings 75' X 140' / 2 = 5250 sf N X = bore hole 51.6 A = 500 gal septic tank B = Cajunaire 500 a C = 600 gal pump tank V 1"=90' i 4 buildings, each with 4 employees x 12 gpd = 48 GPD 192 gpd total 43' NIGHT SPRAY n l 1A ,I L 4 J. J W 2 , D a a 7i'��I14 -TA y w A Np � N n N N Felai g 3 m m w N n m � N 53" Q � � � Q ,^ Ww — � Ix^;C W m � J Q � X � < m 0 w a m Ca 0) a *.