Loading...
HomeMy WebLinkAboutWater Design ReportNovember 24 , 2008 Ms. Erika Bridges Engineering Department City of College Station 1101 Texas Avenue College Station , Texas 77842 Re : Water Design Report Public Restrooms Northgate Area College Station, Texas Gessner Engineering Job No.: 08-0256 Dear Ms. Bridges: This letter shall serve to meet the requirements of a Water Design Report, showing that the design of the proposed improvements meet the flow requirements of the BCS Unified Design Guidelines Manual. The proposed development consists of an approximate 560 square foot (sf) public restroom facility and dumpster relocation in the Northgate Area . There is an existing six (6) inch fire line that serves the fire hydrant located southwest of the proposed restroom . This 6 inch line runs southwest and ties into and existing eight (8) inch water main situated in Patricia Street. It is unknown what the existing eight (8) inch main in Patricia services as this information is not available. Additionally, an analysis of G the existing system and the entire area it serves is not within the scope of this project. The 6 inch PVC line (C200 AWWA C900) that we are tying to was designed by McClure Engineering with their Patricia Street Project dated April 4, 1997. There is no information on these plans that Gessner addresses the design parameters of this line. We did obtain a fire flow . . report from the City of College Station and this information has been Engmeermg provided in the Fire Flow Report for th is project by Gessner Engineering dated November 10, 2008. The water demands for the proposed public restroom were calculated using the fixture unit method . The fixtures include: two (2) lavatories, two (2) urinals, and 6 water closets (tank operated). This gives a total fixture unit count of 36. The gallon per minute (gpm) values for each fixture were applied to the fixture units calculated and a total Peak Water Demand of 55.2 gpm was determined. According to the BCS Unified Design Guidelines, the Average Water Demand is the Peak Water Demand I four (4). This gave an Average Water Demand of 13.8 gpm. 1712 Southwest Pkwy Suite 105 College Station, Texas 77840 P.O. Box I 0763, 77842-0763 979 .680.8840 FAX 979.680.8841 2204 S. Chappell Hill St. Brenham, Texas 77833 979.836.6855 FAX 979.836.6847 G We trust that this report is responsive to the city of College Station requirements. Please contact us if you have any questions or if we can be of further assistance. Sincerely, GESSNER ENGINEERING ~t{J~ Melissa P. Thomas, P.E. Gessner Engineering