Loading...
HomeMy WebLinkAboutStaff Comments1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 /Fax 979.764.764.3496 CITY Or TO NGY.$iAilON lhm r/T AbM Unu'mip' MEMORANDUM March 26, 2012 TO: Ken Tripp, The Tripp Family Trust, via email: kentripp@suddenlink.net FROM: Morgan Hester, Staff Planner, mhester@cstx.gov SUBJECT: Wellborn Business Park Ph 1 & 2 NRA Review Staff reviewed the above -mentioned Non -Residential Architectural plans as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: One (1) revised set of elevation drawings Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised elevations, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments PC: Joe Schultz, Schultz Engineering, LLC; via email: joeschultz84@vedzon.net Case file #12-00500053 STAFF REVIEW COMMENTS NO. 1 Wellborn Business Park Ph 1 & 2 — NRA Review 12-00500053 PLANNING 1. Please provide a site map for orientation of the building and indication of the Right of Way. 2. Please provide a description describing which building/phase, or buildings/phases, in the plan the elevations are representing. Also, please indicate the buildings' total square footage. 3. Per Section 7.9 of the UDO, two different architectural features are required every 45 feet for sides facing the Right of Way and every 60 feet for all other sides. Please show that this requirement has been met by identifying all proposed features. 4. Please identify colors as being Sherwin Williams. 5. FYI — the proposed sign locations will be subject to a separate sign permit process and must comply with Section 7.4 of the UDO. 6. Please show the percentage of area for roll -up doors, doors, and windows (glazed area) in each facades' total area percentage. 7. Roll -up doors are depicted on the rear of the building, but no driving surfaces are shown on the site plan. Please provide explanation and/or revise. 8. On the front elevation, color #7037, Balanced Beige, is proposed as being used, but the color chart shows color #7034, Status Bronze, is being used on the building; however, the color is misnamed as Tony Taupe. Please revise to show what color will be used on the buildings' fagade. Reviewed by: Morgan Hester, Staff Planner Date: March 20, 2012 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 /Fax 979.764.764.3496 CITY Or TO NGY.$iAilON lhm r/T AbM Unu'mip' MEMORANDUM June 1. 2012 TO: Ken Tripp, The Tripp Family Trust, via email: kentripp@suddenlink.net FROM: Morgan Hester, Staff Planner, mhester@cstx.gov SUBJECT: Wellborn Business Park Ph 1 & 2 NRA Review Staff reviewed the above -mentioned Non -Residential Architectural plans as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: One (1) revised set of elevation drawings Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised elevations, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments PC: Joe Schultz, Schultz Engineering, LLC; via email: joeschultz@verizon.net Case file #12-00500053 STAFF REVIEW COMMENTS NO. 1 Wellborn Business Park Ph 1 & 2 — NRA Review 12-00500053 PLANNING 1. Please provide a note about what corresponding phase Buildings 1, 2, 3, and 4 will be constructed. Please ensure that this matches the Site Plan. Buildings 1 and 4 appear to be phased together and have the same building square footages. If they are constructed together, please designate this on the plan. 2. Per Section 7.9 of the UDO, two different architectural features are required every 60 feet for all sides not facing the right of way. Please show that this requirement has been met on the Rear Elevation by identifying all proposed features. Reviewed by: Morgan Hester, Staff Planner Date: June 1, 2012 TxDOT Comments 1. No Comment (not applicable) Reviewed by: Chad Bohne Date: March 23, 2012