Responses to your Engineering Comments #3:
1. Gate valve on main line approximately 460' SW and gate valve on main
line almost directly across the street. I have attached an PDF that
illustrates these locations;
2. There is very little bar-ditch upstream (approximately 200') that will
receive and convey runoff to this point. Runoff then is conveyed into the
bar-ditch and travels approximately 500' to 2-24" RCPs that carry runoff
under Green Prairie Road East. When I did my original study for Creek
Meadows -Section 1 A & 1 B I estimated that the crossing was significantly
oversized and that a single barrel 24" could adequately convey runoff. I
have not performed any tight engineering calculations on the capacity of the
ditch but using some rough estimates I believe the bar-ditch has sufficient
capacity (Q=AV where A=6 sq.ft. and V=3 fps therefore Q=18 cfs).
From this point runoff travels through the Creek Meadows drainage and
detention systems and to the taxed roadway culverts at Greens Prairie Trail
and Royder Road . I do not believe these undetained flows will amplify the
drainage problem for a couple reasons. (1) The detention system of Creek
Meadows reduced runoff below pre-development rates an amount greater than
this project's impervious cover increase, and (2) the detention system
accounted for full-development of all sections upstream of the ponds. There
are many sections that have not developed yet and therefore there is still
"room" for this runoff increase in the pond . Development of Section 1 C's
detention facility is planned to occur prior to all of the "original"
sections developing.
3. Sleeving is required for pressure pipe. No sleeving is required for
non-pressure pipe.
Rabon A. Metcalf, P.E.
RME Consulting Engineers
1391 Seamist Lane <77845>
P.O. Box 9253
College Station, TX 77842
PH: (979) 690-0329
FX: (979) 690-0329
MB: (979) 219-4174
THE ELECTRONIC DATA, CONTENT, INFORMATION, AND/OR DRAWINGS GENERATED, BY RME
CONSULTING ENGINEERS (RME), ATTACHED OR CONTAINED IN THIS ELECTRONIC
TRANSMITTAL IS CONSIDERED BY RME TO BE CONFIDENTIAL. WHEN ISSUED, IT'S USE
IS INTEND SOLELY FOR THE INDIVIDUAL OR ENTITY TO WHICH IT IS ADDRESSED.
THIS MATERIAL IS INTENDED FOR USE BY THE RECIPIENT NAMED, ONLY, AND
PERMISSION IS NOT GRANTED TO THE RECIPIENT FOR DISTRIBUTION OF THESE
DOCUMENTS IN ANY FORM OR FASHION. THE RECIPIENT UNDERSTANDS THAT THIS DATA
IS AUTHORIZED "AS IS" WITHOUT ANY WARRANTY AS TO ITS PERFORMANCE, ACCURACY,
FREEDOM FROM ERROR, OR AS TO ANY RESULTS GENERATED THROUGH ITS USE. THE
RECIPIENT ALSO UNDERSTANDS AND AGREES THAT RME, UPON RELEASE OF SUCH DATA,
Page 1
J (1/12/2009) Carol Cotter -RE: Creek Meadows Phase 1C
IS NO LONGER RESPONSIBLE FOR THEIR USE OR MODIFICATION. THE USER AND
RECIPIENT OF THE ELECTRONIC DATA ACCEPTS FULL RESPONSIBILITY AND LIABILITY
FOR ANY CONSEQUENCES ARISING OUT OF THEIR USE.
-----Original Message-----
From: Carol Cotter [mailto:Ccotter@cstx.gov]
Sent: Wednesday, October 22, 2008 4:36 PM
To: Rabon Metcalf
Subject: Creek Meadows Phase 1 C
Rabon-
Attached are engineering comments for your revised submittal. You should be
receiving formal comments shortly.
Carol