Loading...
HomeMy WebLinkAboutStaff Comments_ CITY OF COLLEGE STATION Home ofTe=AdM University° 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM February 10, 2012 L1 TO: Paul Baumann via email; baumann@suddenlink.netl�� FROM: Jason Schubert, AICP Principal Planner SUBJECT: BAUMANN OFFICE BUILDING (SP/NRA) Thank you for the submittal of the requested documents for your SITE PLAN - COMMERCIAL application. This project will be distributed to staff next week for their review. cc: Sam Vernon via email; svernon@bleylengineering.com Case file no. 12-00500014 r i Case file no. 12-00500023 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 /Fax 979.764.764.3496 CITY Or TO NGY.$iAilON lhm r/T AbM Unu'mip' MEMORANDUM February 20, 2012 TO: Paul Baumann, via email: baumann@suddenlink.net FROM: Morgan Hester, Staff Planner SUBJECT: Baumann Office Building NRA Review Staff reviewed the above -mentioned Non -Residential Architectural plans as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: One (1) revised set of elevation drawings Color Samples Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised elevations, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments PC: Sam Vernon, via email: svernon@bleylengineedng.com Case file #12-00500023 STAFF REVIEW COMMENTS NO. 1 Baumann Office Building NRA Review 12-00500023 PLANNING 1. Per minimum NRA Standards, please provide: • Name, address, location, and legal description in the title block; • Name, address, and telephone number of applicant in the title block. 2. Please show the percentage of material and openings (windows and doors) found on each elevation based on square footage and label accordingly. Reference Section 7.9 in the UDO for minimums and maximums of materials that can be utilized on the building. 3. Please provide a map to show how the building is oriented on site and label each elevation accordingly. 4. For sides not facing the right-of-way, two architectural features every 45 feet must be shown and every 60 feet for those not facing the right-of-way. Please show that this requirement has been met. 5. No more than 66% of the roofline can be at the same elevation. Please show that this requirement has been met on the side facing Morgans Lane 6. The proposed awning/canopy is permitted to only extend 18 inches into the side setback. Please revise and show this extension on the site plan. Reviewed by: Morgan Hester, Staff Planner Date: February 20, 2012 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 /Fax 979.764.764.3496 CITY Or TO NGY.$iAilON lhm r/T AbM Unu'mip' MEMORANDUM March 12, 2012 TO: Paul Baumann, via email: baumann@suddenlink.net FROM: Morgan Hester, Staff Planner SUBJECT: Baumann Office Building NRA Review Staff reviewed the above -mentioned Non -Residential Architectural plans as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: One (1) revised set of elevation drawings Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised elevations, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments PC: Sam Vernon, via email: svernon@bleylengineedng.com Case file #12-00500023 STAFF REVIEW COMMENTS NO. 1 Baumann Office Building NRA Review 12-00500023 PLANNING 1. The maximum allowed use of metal siding on a building's fagade facing the right of way or residences is 20%. Please revise the building materials on the "Rear Elevation". 2. Please factor the use of stucco into building material percentages. Reviewed by: Morgan Hester, Staff Planner Date: March 7, 2012