HomeMy WebLinkAboutWater Report'/:.?: C1VIL DEVELOPMENT, Lta.1:-?: CIVIL ENGINEERING & DESIGN-BUILD SERVICES P.O. Box 11929 · College Station, Texas 77842 · Phone: 979-764-7743 · Fax: 979-764-7759 October 3, 2008 Alan Gibbs, P.E. City of College Station P.O. Box 9960 College Station, TX 77842 RE: Water Analysis and Report Oxford Court Office Building Lot 4 Block 11 , Castlerock Subdivision, Ph 1 B College Station, Texas Dear Alan: The Oxford Court Office Building is planned for Lot 4, Block 11 of the Castlerock Subdivision, Ph 1 B. When that subdivision was developed, the water system was analyzed to determine if sufficient water fiow and ressure was available for fire demands on these commercial lots. co y of that water re ort is attach The fire flow used in that analysis was 2500 gpm at the hydrant across the entry driveway from this lot. The Oxford Court Office Building will lfave 4200 square feet of enclosed area. We do not yet know the building type that would allow us to determine the actual fire flow rate required by the International Fire Code. However, if we assume the most conservative figure using a Building Type V-B1 a building of this size would require 1750 gpm and one hydrant (International Fire Code Tables Bl 05. I and Cl 05.1). Since our system was analyzed using a fire flow rate of 2500 gpm, we conclude that the water system is easily capable of serving this building. No additional water report will be submitted for this development. Sincerely Yours, /~~ Kent Laza, P.E. Project Manager Bathroom Group Bathroom Group Bathtub Bathtub Bidet Combination fixture Dishwashing machine Drinking fountain Kitchen sink Kitchen sink Laundry trays (1 to 3) Lavatory Lavatory Service sink Shower head Shower head Urinal Urinal Urinal Washing machine (8 lbs) Washing machine (8 lbs) Washing machine (15 lbs) Water closet Water closet Water closet Water closet Water closet Oxford Court Office Building Summary of Fixture Unit Computations Total Load per Fixture Type (from Plumbing Code) fixture (wsfu) Private Flush tank 3.60 Private Flush valve 8.00 Private Faucet 1.40 Public Faucet 4.00 Private Faucet 2.00 Private Faucet 3.00 Private Automatic 1.40 Offices, etc. 3/8" valve 0.25 Private Faucet 1.40 Hotel, restaurant Faucet 4.00 Private Faucet 1.40 Private Faucet 0.70 Public Faucet 2.00 Offices, etc. Faucet 3.00 Public Mixing valve 4.00 Private Mixing valve 1.40 Public I" flush valve 10.00 Public 3/4" flush valve 5.00 Public Flush tank 3.00 Private Automatic l.40 Public Automatic 3.00 Public Automatic 4.00 Private Flush valve 6.00 Private Flush tank 2.20 Public Flush valve 10.00 Public Flush tank 5.00 Public or private Flushometer tank 2.00 Fixture Fixture Total Count -1st Count-Total Fixture Fir 2nd Fir Count Units 2 2 7.2 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 I 1 0.3 I I l.4 0 0.0 0 0.0 0 0.0 0 0.0 I I 3.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 TOT AL FIXTURE COUNT = 11.85 Flowrate (from Plumbing Code -Table E102) = Recommended Meter Size = 16 gpm 3/4" LOT4 LOTS LOT6 LOT7 ---W-24---W-24----~~--------~~------------~~---------~~---------~~---- - ------- SH 40 Frontage Road