Loading...
HomeMy WebLinkAboutDriveway Culvert Design SummaryTo: From: Subject: Remarks: TEX,GON TRANSMITTAL October 21, 2005 Carol Cotter Development Services City of College Station Joe Schultz, P .E. ~ Texcon General C~ractors 1707 Graham Road College Station, Texas 77845 Phone: (979) 764-7743 Driveway Culvert Design Summary Williams Creek Subdivision -Phase 3 College Station, Texas d:~( \D ~40 S ~ Qt?) v l ~ d-' Attached is a summary of the driveway culvert design for Williams Creek Phase 3. The culverts were designed to pass the 10-year storm event runoff with headwater equal to or less than the diameter of the pipe. Please contact me if you have any questions. Williams Creek Subdivision -Phase 3 Driveway Cu lvert Summary Block# Lot# Street #of Pipe size Slope Tc Contributing Area Contributing Barrels (in) (%) (min) No. Area (ac) 1 18 Johnson Creek Loop 1 12 0.60 10.0 402 0.28 ----f------------ 19 Johnson Creek Loop 1 12 0.60 10.0 402 0.28 --20 Johnson Creek Loop 1 12 1.32 10.0 403 0.23 21 Johnson Creek Loop 1 12 0.60 10.0 403,406 0.43 --22 Johnson Creek Loop 1 12 2.20 10.0 408,409 0.40 --------23 Johnson Creek Loop 1 12 4.45 10.0 409 0.29 ------24 Johnson Creek Loop 1 12 2.28 10.0 409 0.29 ------25 Johnson Creek Loop 1 12 1.00 10.0 413 0.24 -----26 Johnson Creek Loop 1 12 0.60 10.0 413 0.24 27 Johnson Creek Loop 1 12 0.60 10.0 413 0.24 -- 28 Johnson Creek Loop 1 18 4.34 10.0 415,418,419,422,423 1.37 -------------29 Johnson Creek Loop 1 18 7.00 10.0 418,419,422,423 1.15 ----------- 30 Johnson Creek Loop 1 12 5.48 10.0 419,422,423 0.39 ---------31 Johnson Creek Loop 1 12 2.23 10.0 423 0.23 32 Johnson Creek Loop 1 12 0.60 10.0 423 0.23 3 8 Johnson Creek Loop 1 24 1.63 22.3 401,401A(75%) 4.07 ----9 Johnson Creek Loop 1 18 0.60 21.4 401 1.80 -10 Johnson Creek Loop 1 15 1.32 34.8 404 1.76 ---11 Johnson Creek Loop 1 15 1.32 34.8 404 1.76 12 Johnson Creek Loop 1 24 0.60 35.8 404,405 2.99 --13 Johnson Creek Loop 1 18 2.20 16.4 410 1.35 ----e----14 Johnson Creek Loop 1 18 2.28 16.4 410 1.35 --- 15 Johnson Creek Loop 1 24 5.48 30.0 417,420,421,424 3.14 ---~ --16 Johnson Creek Loop 1 18 5.48 29.1 420,421,424 2.11 --17 Johnson Creek Loop 1 15 2.23 28.7 421,424 1.41 ---- 18 Johnson Creek Loop 1 15 0.80 28.0 424 1.15 -19 Johnson Creek Loop 1 15 0.60 28.0 424 1.15 Notes: 1. All driveway pipes shall be RCP, T&G, Class 3. 2. All S.E.T.s shall be pre-cast and in accordance with TxDOT Standard Sheet PSET-RC, PRECAST SAFETY EN D TREATMENT, TY II -CROSS DRAI NAGE. - 0 10 (cfs) 1.21 1.21 --0.99 --1.86 --1.73 1.25 1.25 -1.04 ---1.04 1.04 5.91 -4.96 1.68 0.99 --0.99 11.91 5.39 3.97 3.97 -- 6.63 -- 4.65 4.65 7.75 5.30 3.57 -2.96 2.96 3. Refer to Exhibit B from the Drainage Report for Williams Creek Subdivision , Phase 3, dated October, 200 5.