HomeMy WebLinkAboutWastewater Design MemoKLING ENGINEERING & SURVEYING Consulting Engineers • Land Surveyors 4101 Texas Avenue, Suite A Post Office Box 4234 Bryan, .Texas 77802 Bryan, Texas 77805 Memo: B.J . Kling, P.E., R.P.L.S. S.M. Kling, R.P.L.S. Telephone 979/846-6212 Fax 979/846-8252 To: City of College Station, Development Services c/o Josh Norton Re : First Victoria Bank Lot 2A, Block 2, Crescent Pointe Phase 4 Wastewater Design Memo From: Fred Paine, P.E.5?f' September 24, 2007 As required by the B/CS Unified Design Guideline Manual, this memo is to serve as the Wastewater Design Report for the above referenced development. Currently serving the tract is an existing 12" pvc sanitary sewer line . The as-built slope of this line is approximately 1.3%. Full flow capacity determined using Manning's Equation was found to be 1,823 gpm. Using Method 2 from the B/CS guidelines, total peak hourly demand for the 1.6 acre bank tract was estimated to be 6.65 gpm. Based on this site development, no capacity problems are anticipated. KLING ENGINEERING & SURVEYING Consulting Engineers • Land Surveyors 4101 Texas Avenue, Suite A Post Office Box 4234 Bryan, Texas 77802 Bryan, Texas 77805 Memo: B.J. Kling, P.E., R.P.L.S . S.M. Kling, R.P.L.S . Telephone 979/846-6212 Fax 979 I 846-8252 To : City of College Station, Development Services c/o Josh Norton Re: First Victoria Bank Lot 2A, Block 2, Crescent Pointe Phase 4 Waterline Design Memo From: Fred Paine, P.~ September 24, 2007 As required by the B/CS Unified Design Guideline Manual , this memo is to serve as the Waterline Design Report for the above referenced development. Currently serving the tract is an existing 12" pvc waterline . According to City of College Station Water Services department, this existing line has static pressures of 86-96 psi (Butch Willis 2007/09/21 ). The proposed building will be a 5190 gsf building assumed to be of type V-B construction. In accordance with the International Fire Code, this building will require a 2,000 gpm fire flow serviced by 2 fire hydrants. Per the B/CS Unified Design Guideline Manual, the minimum non-residential fire flow is to be 2,500 gpm . Using a 2,500 gpm demand split between two fire hydrants (refer to site plan for location), it was determined that the fire flow demand will be satisfied with a minimum residual pressure of 83.4 psi and a maximum velocity of 7.1 ft/sec in the existing line (refer to attached summary results from the Haestad Cybernet software program ). Title: FIRST VICTORIA BA NK h:\ei61rv-4\c0ywav-7\p90orf-u\fbibe2-y\ff. wed 09124107 05:02:08 PM © Haestad Methods, Inc. Scenario: Base J-2 P-2 J-1 p 1 R 1 Kling Engineering & Surveying 37 Brookside Road Waterbury, CT 06708 USA Project Engineer: FRED PAINE Cybernet v3.1 [071] (203) 755-1666 Page 1 of 1 Link Length Diamete1 Material Roughness Minor Loss Initial Current Discharge Label (ft) (in) Status Status (gpm) P-1 307.00 12 PVC 150.0 1.28 Open Open 2,500.00 P-2 213.00 12 PVC 150.0 2.02 Open Open 1,250.00 Scenario: Base Steady State Analysis Pipe Report Velocity Start End Start (ft/s) ~alculated Calculated Pressure Hydraulic Hydraulic (psi) Grade Grade (ft) (ft) 7.09 482.96 478.69 3.55 478.69 477.66 84.19 Kling Engineering & Surveying End Head loss Pressure (ft) (psi) 84.19 4.27 83.38 1.02 Title: FIRST VICTORIA BANK h:\ei61rv-4\c0ywav-7\p90orf-ulfbibe2-y\ff. wed 09/24/07 04:55:02 PM © Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Project Engineer: FRED PAINE Cybernet v3.1 [071] Page 1 of 1