Loading...
HomeMy WebLinkAboutStaff CommentsJune 22, 2009 Josh Norton, P.E and Lauren A. Hovde City of College Station Planning & Development Services 1101 Texas Avenue South College, Station, 77840 P.O. Box 9253, College Station, TX 77842 Off/Fax: (979) 690-0329 email: civil@rmengineer.com RE: Sleep Inn & Suites -1195 Earl Rudder Freeway South, College Station, TX Lot 2B, Block One -High Ridge Subdivision -Brazos County Staff Review Comments No. 2 -Response Memorandum RME No. 231-0351 Josh & Lauren: Please find below response to Staff Review Comments No. 2 for the above referenced project. Staff comments are italicized and responses are following each comment in bold print. PLANNING 1. There are two minor text adjustments that need to be made. Since Lot 2B is being developed in two phases, please add to the title block that this Site Plan is for Phase 1 of Lot 2B, Block 1 of the High Ridge Subdivision. Also, please revise Note 17 on the Landscape Plan to refer to the City of College Station, instead of the City of Bryan. Thank you for making these changes. Title block corrected on ALL sheets and Note 17 of the Landscape Plan corrected; 2. The 3 ' landscaped area that was discussed previously does need to be 4 ' of actual landscaped space per Section 7.2.C.2. This depth should be measured from back of curb. Revised accordingly; 3. Please extend the fire lane around the parking area as previously discussed. Revised accordingly; 4. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not be made of aware of will constitute a completely new review. Not applicable; 5. Comments regarding the driveway location may follow from Joe Guerra. Email correspondence attached; ENGINEERING COMMENTS NO. 2 ~ease update water/fire flow report. Revised Utility Availability Letter attached; ~Please submit Letter of Acknowledgement. Letter attached; CD1 -231-0351-L08 Page 1 of2 Sleep Inn & Suites -College Station, TX Staff Comment Response Memo #2 June 22, 2009 anket easement will need to be executed prior to site plan approval. Acknowledge. Per my phone conversation with Mrs. Deborah Grace-Rosier, see attached email correspondence, the Blanket Easement is in route to be executed by the Landowner and Lender. One I have this document I will turn it into the City; (![;>please update the TxDOT utility permit, the construction documents provided with the on-line permit are dated from April and do not match the most recent set dated in June. The most recent Sheet Cl.3 -"On-Site Utility Plan" has been added on-line; tJ) How will the flow of water be conveyed to the stream from the proposed headwall outfall located at the property line? Has the developer been given permission from the adjacent property owner to discharge across their property? How will erosion on the downstream properties be mitigated? How will the downstream sanitary sewer conflict be protected from erosion? Sheet Cl.O -"Erosion Control Plan" and Sheet Cl.2 -"Grading & Drainage Plan" are included in the full set of Construction Drawings with this submission. These sheets address the proposed outfall, erosion control measures, and conveyance of runoff. "Permission" letter for downstream landowner has been requested and will be .?>vided ASAP; ,,,. Please submit culvert and inlet sizing data. Requested data contained in revised Drainage ~tter; /.As this project is not proposing detention, please *certify that the development is utilizing rapid conveyance to the primary channel. Also please verifying that the sites discharge hydrograph and peak is ahead of the main channels hydrograph is such a manner that it does not create a new resulting peak greater than the main channels existing peak, so that there are no negative impacts. Requested certification contained in revised Drainage Letter; Please do not hesitate to call should you have any questions. Sincerely, Rabon A. Metcalf, .E. Texas Firm Registration No. F-004695 rabon@rmengineer.com CD1-231-0351-L08 Page 2 of2